| AGILENT ITEM NO. |
AGILENT GC COLUMN DESCRIPTION |
| Agilent 009-1075 |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
500mm ID. Length: 6000mm. Film: 1.5um. Temperature Range: -600 to
325[degree]C. |
| Agilent 0100-0050 |
Agilent Caps Stainless Steel. 1/16 in.
cap. |
| Agilent 0100-0058 |
Agilent Nut Brass. 3.2mm. |
| Agilent 0100-0073 |
Agilent Reducers Stainless Steel. 1/16 1/8
in. reducer. |
| Agilent 0100-0089 |
Agilent Tees Stainless Steel. 1/4 in.
tee. |
| Agilent 0100-0091 |
Agilent Elbows Brass. 1/8 in. |
| Agilent 0100-0111 |
Agilent Connectors (Swagelok to Male NPT)
Stainless Steel. 1/8 1/8 in. connector. |
| Agilent 0100-0118 |
Agilent Connectors (Swagelok to Female NPT)
Brass. 1/8 1/4 in. connector. |
| Agilent 0100-0119 |
Agilent Connectors (Swagelok to Female NPT)
Brass. 1/4 1/4 in. connector. |
| Agilent 0100-0121 |
Agilent Reducing Unions Stainless Steel.
1/8 x 1/4 in. reducing union. |
| Agilent 0100-0124 |
Agilent Union Stainless Steel. 1/16 in.
union. |
| Agilent 0100-0126 |
Agilent Union Stainless Steel. 1/8 in.
union. |
| Agilent 0100-0128 |
Agilent Union Stainless Steel. 1/4 in.
union. |
| Agilent 0100-0132 |
Agilent Bulkhead Unions Brass. 1/8 in.
bulkhead union. |
| Agilent 0100-0133 |
Agilent Bulkhead Unions Stainless Steel.
1/8 in. bulkhead union. |
| Agilent 0100-0160 |
Agilent General GC/MS Supplies and Electron
Multipliers fluoropolymer resin 1/4 in. O-ring (back). Cleaning and Maintenance
Supplies. |
| Agilent 0100-0161 |
Agilent Cross Brass. 1/8 in. |
| Agilent 0100-0241 |
Agilent Reducing Unions Stainless Steel.
1/16 x 1/8 in. reducing union. |
| Agilent 0100-0420 |
Agilent Adapters Brass. 1/8 x 1/8 in.
adapter. |
| Agilent 0100-0782 |
Agilent Tees Stainless Steel. 1/16 in.
tee. |
| Agilent 0100-0787 |
Agilent General GC/MS Supplies and Electron
Multipliers fluoropolymer resin 1/4 in. O-ring (front). Cleaning and
Maintenance Supplies. |
| Agilent 0100-0929 |
Agilent Nut, male 1/16in SS Nut, male
1/16in SS. |
| Agilent 0100-0985 |
Agilent Cross Brass. 1/4 in. |
| Agilent 0100-1017 |
Agilent HP 1090 Pump and Flow Path Supplies
Union, 1/16 in., stainless steel. |
| Agilent 0100-1104 |
Agilent Straight Ferrules 6.4 mm Vespel.
For Capillary Columns. |
| Agilent 0100-1107 |
Agilent Front Ferrule Graph Vespel. 3.2mm
ID. |
| Agilent 0100-1145 |
Agilent Interface gasket, VCR nickel
Interface gasket, VCR nickel. |
| Agilent 0100-1189 |
Agilent Connectors (Swagelok to Male NPT)
Stainless Steel. 1/8 1/4 in. connector. |
| Agilent 0100-1316 |
Agilent Union Brass. 1/16 in. union. |
| Agilent 0100-1324 |
Agilent Straight Ferrules 1/4 in. graphite.
For Capillary Columns. |
| Agilent 0100-1325 |
Agilent Straight Ferrules 1/8 in. graphite.
For Capillary Columns. |
| Agilent 0100-1326 |
Agilent Straight Ferrules 1/16 in.
graphite. For Capillary Columns. |
| Agilent 0100-1327 |
Agilent HP 5921/G2350A Atomic Emission
Detector Supplies HP 5921/G2350A Common Parts. 1/4 in. Vespel ferrules.
Environmental laboratories are using the Atomic Emission Detector (AED) to make
GC analysis of unknowns faster and more accurate. |
| Agilent 0100-1328 |
Agilent General GC/MS Supplies and Electron
Multipliers Ferrule, 1/8 in. Vespel. Ferrules for Capillary Direct or
Open-Split Interface. |
| Agilent 0100-1329 |
Agilent HP 5921/G2350A Atomic Emission
Detector Supplies HP 5921/G2350A Common Parts. 1/16 in. Vespel ferrules.
Environmental laboratories are using the Atomic Emission Detector (AED) to make
GC analysis of unknowns faster and more accurate. |
| Agilent 0100-1331 |
Agilent General GC/MS Supplies and Electron
Multipliers Ferrule, 1/4 in. Vespel. Ferrules for Capillary Direct or
Open-Split Interface. |
| Agilent 0100-1332 |
Agilent General GC/MS Supplies and Electron
Multipliers Ferrule, 1/8 in. Vespel. Ferrules for Capillary Direct or
Open-Split Interface. |
| Agilent 0100-1333 |
Agilent General GC/MS Supplies and Electron
Multipliers Ferrule, 1/16 in. Vespel. Ferrules for Capillary Direct or
Open-Split Interface. |
| Agilent 0100-1342 |
Agilent Reducing Ferrules 1/8 to 1/16 in.
Vespel. For Capillary Columns. |
| Agilent 0100-1344 |
Agilent Reducing Ferrules 1/8 to 1/16 in.
VG-1 Vespel, 15% graphite. For Capillary Columns. |
| Agilent 0100-1354 |
Agilent HP 5985/87/88 Parts and Supplies
Ferrule for jet separator, 0.8 mm Vespel. Sample Introduction Parts,
GC/MS. |
| Agilent 0100-1365 |
Agilent HP 5921/G2350A Atomic Emission
Detector Supplies HP 5921/G2350A Common Parts. 1/8 in. Vespel ferrules.
Environmental laboratories are using the Atomic Emission Detector (AED) to make
GC analysis of unknowns faster and more accurate. |
| Agilent 0100-1372 |
Agilent Ferrule, 1/8in 60%Vespel, no hole
10/pk Ferrule, 1/8in 60%Vespel, no hole 10/pk. |
| Agilent 0100-1375 |
Agilent Straight Ferrules 1/16 in.
fluoropolymer resin. For Capillary Columns. |
| Agilent 0100-1378 |
Agilent Straight Ferrules 1/4 in.
fluoropolymer resin. For Capillary Columns. |
| Agilent 0100-1379 |
Agilent Straight Ferrules 1/16 in. VG-2
Vespel, 40% graphite. For Capillary Columns. |
| Agilent 0100-1381 |
Agilent Reducing Ferrules 1/16 in. to 0.4
mm VG-2 Vespel, 40% graphite. For Capillary Columns. |
| Agilent 0100-1383 |
Agilent Ferrule, reducing 1/16in-0.8mm
Vespel 10/pk Ferrule, reducing 1/16in-0.8mm Vespel 10/pk. |
| Agilent 0100-1389 |
Agilent On-Column Syringes Replacement
fluoropolymer resin ferrule for HP Part Number 9301-0658. Ideal for manual
on-column injections. Depending on column diameter, choose either fused silica
or durable stainless steel. |
| Agilent 0100-1443 |
Agilent HP 59980B Particle Beam Supplies
Capillary ferrule. LC/MS Supplies. |
| Agilent 0100-1490 |
Agilent Ferrule, front/back 1/16in SS
Ferrule, front/back 1/16in SS. |
| Agilent 0100-1511 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 Parts for Interfacing Capillary Columns to W Series Valves. 1/16
in. stainless steel counterbored nut. For use with above liners. |
| Agilent 0100-1512 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 Parts for Interfacing Capillary Columns to W Series Valves.
Polyimide 1/16 in. ferrule. |
| Agilent 0100-1513 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 Parts for Interfacing Capillary Columns to W Series Valves.
Polyimide liner for 530 um columns. |
| Agilent 0100-1514 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 Parts for Interfacing Capillary Columns to W Series Valves.
Polyimide liner for 320 um columns. |
| Agilent 0100-1515 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 Parts for Interfacing Capillary Columns to W Series Valves.
Stainless Steel bulkhead ZDV union. For interfacing 530 pm columns with 1/16
in. transfer line. |
| Agilent 0100-1527 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 Parts for Interfacing Capillary Columns to W Series Valves.
Stainless Steel bulkhead ZDV union. For interfacing 320 um columns with 1/16
in. transfer line. |
| Agilent 0100-1619 |
Agilent Zero Dead-Volume Union, U-435
Stainless steel. 0.25mm thru-hole. Used to connect fused silica tubing. |
| Agilent 0101-0030 |
Agilent Flowmeter, soap film 10ml For use
with Snoop soap solution 9300-0311. |
| Agilent 0101-0300 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 2.00 cc Loop. |
| Agilent 0101-0301 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 5.00 cc Loop. |
| Agilent 0101-0302 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 10.00 cc Loop. |
| Agilent 0101-0355 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 Valve-Related Parts. Metering valve. For LSVs as a sample-out
restrictor or as a flow-balancer for 10-100 ml/min. |
| Agilent 0101-0403 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 Valve-Related Parts. Angle metering valve, 1/8 in. stainless
steel. |
| Agilent 0101-0460 |
Agilent Valve, 6-port 300C max Includes
1/16in. SS fittings and ferrules. |
| Agilent 0101-0532 |
Agilent In-line filter assembly, 7um For
use with GC effluent splitters. Replacement filter: 3150-0404. |
| Agilent 0101-0584 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 General-Purpose Valves. Gas sampling. 6 port replacement valve WE
series, 300 psi, 350[degree]C. |
| Agilent 0101-0585 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 General-Purpose Valves. Gas sampling. 10 port replacement valve WE
series, 300 psi, 350[degree]C. |
| Agilent 0101-0594 |
Agilent Capillary Splitters Fixed outlet
splitter for capillary columns (not for use with 0.53 mm). 1:1 ratio splitter.
Tubing ID: 0.220 mm to 0.220 mm. |
| Agilent 0101-0595 |
Agilent Capillary Splitters Fixed outlet
splitter for capillary columns (not for use with 0.53 mm). 1:10 ratio splitter.
Tubing ID: 0.210 mm to 0.110 mm. |
| Agilent 0101-0633 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 Valve-Related Parts. Micrometering valve. For flow balancing gas
flows of 2-50 ml/min. |
| Agilent 0101-0636 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 Liquid sampling. 0.2 ul replacement valve UWP series, 1,000 psi,
75[degree]C. |
| Agilent 0101-0637 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 Liquid sampling. 0.5 ul replacement valve UWP series, 1,000 psi,
75[degree]C. |
| Agilent 0101-0638 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 Liquid sampling. 1.0 ul replacement valve UWP series, 1,000 psi,
75[degree]C. |
| Agilent 0101-0639 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 Liquid sampling. 0.5 ul replacement valve UW series, 5,000 psi,
75[degree]C. |
| Agilent 0101-1398 |
Agilent Regulator for Helium Gas He Gas for
ICP-MS reaction gas. |
| Agilent 0101-1399 |
Agilent Regulator for Hydrogen Gas H2 Gas
for ICP-MS reaction gas. |
| Agilent 0101-1400 |
Agilent Regulator for Argon Gas Argon Gas
for ICP-MS |
| Agilent 01040-87602 |
Agilent Parts and Supplies for HP
1037/40/46/47/49 Detectors Parts for HP 1037/47A Refractive Index Detector.
Inlet capillary, 880 mm x 0.12 mm id, rigid. |
| Agilent 01078-87305 |
Agilent Capillary Tubing (stainless steel),
with Swagelok fittings Length: 800 mm. |
| Agilent 01078-87306 |
Agilent Capillary Tubing (stainless steel),
with Swagelok fittings Length: 700 mm. |
| Agilent 01090-22404 |
Agilent Fluoropolymer resin tubing screw
with barb fitting For use with 1090 bottle head assembly and fluoropolymer
resin Helium tubing. |
| Agilent 03394-20500 |
Agilent Paper and Supplies for HP 3397A, HP
3396 Series III, and HP 3396A/B/95/94 Replacement paper roll rod. |
| Agilent 03394-60540 |
Agilent Cables to Connect any HP 3394/95A
and 3396A/B Integrator General Purpose cable. Remote. |
| Agilent 03394-60560 |
Agilent Cables to Connect any HP 3394/95A
and 3396A/B Integrator HP 5890 GC cable. Remote. |
| Agilent 03394-60600 |
Agilent Cables from HP Integrators to HP
1046A Fluorescence Detector Remote. Remote Start/Stop Cable from HP 1100 series
to HP 3396(A) & 3396(B) Series II Integrator. |
| Agilent 03396-60560 |
Agilent Cables from HP Integrators to HP
1050, 1090 Series Sample No. BCD Cables from HP 1100 Series to HP 3396
integrator. |
| Agilent 03396-60650 |
Agilent Cables from HP Integrators to HP
1090, 1040 Series Remote. |
| Agilent 03396-61010 |
Agilent Cables to Connect any HP 3394/95A
and 3396A/B Integrator HP 6890 Series GC cable. Remote. |
| Agilent 03396-61020 |
Agilent Analog signal cable, 6890 to
integrator Pins 15m/9m. |
| Agilent 0460-0186 |
Agilent HP 7694 Headspace Analysis Supplies
HP 19395A Miscellaneous. Thermosetting tape. |
| Agilent 0460-1266 |
Agilent Fluoropolymer resin Tape Roll of
fluoropolymer resin tape. |
| Agilent 0515-1446 |
Agilent Set Screw For MSD ion source. |
| Agilent 05890-61090 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 Valve-Related Parts. Solenoid valve for controlling actuator. |
| Agilent 05890-61260 |
Agilent Chemical Filters/Traps Chemical
filter for HP 5890 internal. |
| Agilent 05921-21170 |
Agilent Ferrules and Nuts for Capillary
Columns Column nut for two-hole ferrules, 1/16 in. These ferrules are
recommended for use with GC inlets and FID, NPD and ECD. The 100% Vespel
ferrule can be used for most applications and will emerge from the fitting in
reusable condition time and again. |
| Agilent 05921-21850 |
Agilent HP 5921/G2350A Atomic Emission
Detector Supplies Ferrule nut. Environmental laboratories are using the Atomic
Emission Detector (AED) to make GC analysis of unknowns faster and more
accurate. |
| Agilent 05921-21860 |
Agilent HP 5921/G2350A Atomic Emission
Detector Supplies Ferrule key. Environmental laboratories are using the Atomic
Emission Detector (AED) to make GC analysis of unknowns faster and more
accurate. |
| Agilent 05921-61090 |
Agilent HP 5921/G2350A Atomic Emission
Detector Supplies Discharge Tube. Environmental laboratories are using the
Atomic Emission Detector (AED) to make GC analysis of unknowns faster and more
accurate. |
| Agilent 05921-61095 |
Agilent AED Sapphire discharge tube kit
Includes sapphire (aluminum oxide) discharge tube, ferrule, and o-ring. While
this discharge tube may perform similarly to a fused silica tube, performance
may be application dependent (ie. |
| Agilent 05921-80350 |
Agilent HP 5921/G2350A Atomic Emission
Detector Supplies Spectrometer window-cleaned. Environmental laboratories are
using the Atomic Emission Detector (AED) to make GC analysis of unknowns faster
and more accurate. |
| Agilent 05930-20458 |
Agilent HP 5985/87/88 Parts and Supplies
Plunger Support insulator. Ion Source Parts and Supplies. |
| Agilent 05970-60045 |
Agilent Qualitative Standards Qualitative
MS Standards. Samples for GC/MS Systems. HP 5970 Performances Evaluation Sample
Contains 6 vials: 4 vials (10 ng/ul), 1 vial (100 pg/ul), and 1 vial (100
ng/ul) each of dodecane biphenyl, p-chlorodiphenyl, and metnyl palmitate in
isooctane, 1 ml ampoule. |
| Agilent 05970-80102 |
Agilent Electron Multiplier Life
expectancy: 9 to 12 months. |
| Agilent 05971-20134 |
Agilent Drawout Plate For MSD Ion
Source. |
| Agilent 05971-20143 |
Agilent Ion Focus Lens For MSD Ion
Source. |
| Agilent 05971-40100 |
Agilent HP GCD/5971/72 MSD Parts and
Supplies Baseplate/manifold seal (HP 5971). Miscellaneous Parts and
Supplies. |
| Agilent 05971-60140 |
Agilent HP GCD/5971/72 MSD Parts and
Supplies Filament assembly (HP GCD/5971). Miscellaneous Parts and
Supplies. |
| Agilent 05971-60170 |
Agilent Repeller assembly for the
5971/72/GCD |
| Agilent 05971-60561 |
Agilent HP GCD/5971/72 MSD Parts and
Supplies MSD Tool Kit. MSD Tool Kit includes: Small abrasive sticker, Large
abrasive sticker, Small cleaning rod, Large cleaning rod, Source hold tool,
Cotton swabs, Nylon gloves (1 pair), Abrasive sheet, 30 um (5/pk), Tool kit
(wrenches, driving tools). Kits. |
| Agilent 05971-80101 |
Agilent Electron multiplier Electron
multiplier. |
| Agilent 05971-80102 |
Agilent General GC/MS Supplies and Electron
Multipliers Electron Multiplier for the 5971/72/73. Electron Multipliers and
Replacement Horns. |
| Agilent 05971-80103 |
Agilent General GC/MS Supplies and Electron
Multipliers Electron Multiplier Replacement Horn. For use with 5970/71/72/73
and 5989 multipliers. Electron Multipliers and Replacement Horns. |
| Agilent 05980-20018 |
Agilent General GC/MS Supplies and Electron
Multipliers PFTBA glass bulb. Cleaning and Maintenance Supplies. |
| Agilent 05980-60051 |
Agilent Lens cleaning paper, lint free
UV/VIS. Cell Accessories. |
| Agilent 05985-60179 |
Agilent HP 5985/87/88 Parts and Supplies
Welded filament assembly. Direct Insertion Probe (DIP). |
| Agilent 05985-60180 |
Agilent General GC/MS Supplies and Electron
Multipliers Electron Multiplier, 4-lead Type, (negative ions only). For use
with 5985/87/88. Electron Multipliers and Replacement Horns. |
| Agilent 05988-20066 |
Agilent Column Nut For ion source. Nut for
Capillary Columns. MS interface column nut for GC/MS. |
| Agilent 05989-20109 |
Agilent HP 5989 MS Engine Parts and
Supplies Plate insulator, ion source. Ion Source Parts and Supplies. |
| Agilent 05989-20145 |
Agilent HP 5989 MS Engine Parts and
Supplies EI/CI repeller. Ion Source Parts and Supplies. |
| Agilent 05989-20165 |
Agilent HP 5989 MS Engine Parts and
Supplies Filament block. Ion Source Parts and Supplies. |
| Agilent 05989-80043 |
Agilent General GC/MS Supplies and Electron
Multipliers Electron Multiplier for the 5989. Electron Multipliers and
Replacement Horns. |
| Agilent 05990-60075 |
Agilent Tuning & System Perform Stand
Tuning & System Perform Stand. |
| Agilent 05990-60084 |
Agilent HP 5970 MSD Parts and Supplies
Filament assembly for ion source. |
| Agilent 07673-20570 |
Agilent HP Automatic Liquid Sampler
Supplies Miscellaneous Autosampler Supplies. Screw for mounting syringe. |
| Agilent 07673-40180 |
Agilent HP Automatic Liquid Sampler
Supplies Miscellaneous Autosampler Supplies. Diffusion caps for 4 ml
vials. |
| Agilent 07673-60840 |
Agilent HP Automatic Liquid Sampler
Supplies 7673 Basic Supply Kit. This kit contains: 10 ul syringes (6/ea),
23/26-gauge needles, 4 ml vials with diffusion caps (144/pk), 2 ml automatic
sampler vials with screw caps (1,000/pk) GC septa (25/pk), Vial racks
(5/pk). |
| Agilent 07673-61330 |
Agilent 250/320 needle support kit, septum
nut For 7673 injector. |
| Agilent 07673-61340 |
Agilent Needle support kit, auto 320/250
For 7673 injector. |
| Agilent 07675-80050 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 Tube, 1/16 in. with 1/8 in. bulkhead fitting, 520 mm long. |
| Agilent 07680-21550 |
Agilent Check valve seal Check valve
seal. |
| Agilent 07680-21565 |
Agilent Sieve Holder |
| Agilent 07680-21670 |
Agilent SFE tubing, 1/16in. 124.5mm SS
Tubing between nozzle and pre-nozzle filter. |
| Agilent 07680-60790 |
Agilent HP 7680 Supercritical Fluid
Extractor Supplies Packed ODS trap assembly. |
| Agilent 07680-61350 |
Agilent HP 7680 Supercritical Fluid
Extractor Supplies Packed Stainless steel balls trap assembly. |
| Agilent 07680-62105 |
Agilent HP 7680 Supercritical Fluid
Extractor Ring frit assembly. |
| Agilent 07680-62130 |
Agilent HP 7680 Supercritical Fluid
Extractor Supplies Packed Tenax trap assembly. |
| Agilent 07680-62140 |
Agilent HP 7680 Supercritical Fluid
Extractor Supplies Packed Diol trap assembly. |
| Agilent 07680-62150 |
Agilent HP 7680 Supercritical Fluid
Extractor Supplies Packed Cyano trap assembly. |
| Agilent 07680-62300 |
Agilent Trap Assembly Packed Florsil. |
| Agilent 08451-60104 |
Agilent HP 8452A Supplies Standard cell
holder. UV/VIS. Spectrophotometer Supplies. |
| Agilent 08452-60104 |
Agilent HP 8452A Supplies Deuterium lamp
assembly for HP 8452A and 8452A, option 002. UV/VIS. Spectrophotometer
Supplies. |
| Agilent 08452-60121 |
Agilent HP 8452A Supplies Tungsten lamp
assembly for HP 8452A, NIR version. UV/VIS. Installation Kit for HP 5890
without Gas Purifier System. |
| Agilent 0854-0141 |
Agilent HP 5890 Detector Supplies FPD
Supplies. Glow plug. |
| Agilent 0890-1761 |
Agilent HP 1049 Electrochemical Detector
Parts and Supplies PEEK tubing, 1/16 in. od, 0.5 mm id. 1.5 m length,
orange. |
| Agilent 0890-1762 |
Agilent PEEK Tubing and Fittings 1.5 m PEEK
Tubing (without fittings). ID: 0.25 mm. OD: 1/16 in. |
| Agilent 0890-1763 |
Agilent PEEK Tubing and Fittings 1.5 m PEEK
Tubing (without fittings). ID: 0.18 mm. OD: 1/16 in. |
| Agilent 0890-1893 |
Agilent Sleeve for 375u od fused silica
tubing Sleeve for 375u od fused silica tubing. |
| Agilent 0890-1901 |
Agilent HP 59987 ElectroSpray Interface
Supplies PEEK tubing,.0025 in. id. LC/MS Supplies. |
| Agilent 0890-1915 |
Agilent PEEK Tubing and Fittings 1.5 m PEEK
Tubing (without fittings). ID: 0.13 mm. OD: 1/16 in. |
| Agilent 0890-1921 |
Agilent HP 59987 ElectroSpray Interface
Supplies PEEK tubing,.03 in. id. LC/MS Supplies. |
| Agilent 0905-0103 |
Agilent O-Rings Miscellaneous O-rings.
0.237 in. id, 0.103 in. cd, Viton. CD = CROSS DIAMETER. Used with actuator
valve. |
| Agilent 0905-0464 |
Agilent O-Rings Miscellaneous O-rings.
0.563 in. id, 0.062 in. cd, Monel. CD = CROSS DIAMETER. Used with HP 5700 ECD
and HP 5830/40A. |
| Agilent 0905-0466 |
Agilent Copper Gasket 15.2cm (6"). |
| Agilent 0905-0820 |
Agilent HP 5985/87/88 Parts and Supplies
Radial seals for 1/2 in. DIP inlet with spring. Direct Insertion Probe
(DIP). |
| Agilent 0905-0938 |
Agilent HP 5995 Parts and Supplies Sealing
ring, open-split. Sample Introduction Parts for Capillary Columns. |
| Agilent 0905-0970 |
Agilent HP 1090 Pump and Flow Path Supplies
Waste sleeve: O-ring, 4 mm id, 4.8 mm od. |
| Agilent 0905-0989 |
Agilent Piston seal, 1090, 1/pk Graphitized
fluoropolymer resin. |
| Agilent 0905-1145 |
Agilent O-ring, Viton 12/pk O-ring, Viton
12/pk. |
| Agilent 0905-1159 |
Agilent HP 5921/G2350A Atomic Emission
Detector Supplies HP 5921/G2350A Common Parts. GC chamber O-ring. Environmental
laboratories are using the Atomic Emission Detector (AED) to make GC analysis
of unknowns faster and more accurate. |
| Agilent 0905-1175 |
Agilent 79851A/52 Pump Module Parts and
Supplies Wash seal. HP 1050 Pump. |
| Agilent 0905-1189 |
Agilent HP 5989 MS Engine Parts and
Supplies O-ring manifold window. Miscellaneous Parts and Supplies. |
| Agilent 0905-1194 |
Agilent HP 1090 Pump and Flow Path Supplies
Pump seal, orange (use for buffered solutions). |
| Agilent 0905-1199 |
Agilent HP 1050 TI Pump Pump Module Parts
and Supplies. Piston seal. |
| Agilent 0905-1245 |
Agilent HP 7686 Solution Phase Synthesizer
Supplies O-ring. Compatible with HP PrepStation. |
| Agilent 0905-1259 |
Agilent HP 1090 Pump and Flow Path Supplies
Kalrez O-ring, for solvent reservoir. |
| Agilent 0905-1294 |
Agilent Metering Valve Seal For Agilent
1100 Standard Autosampler Metering Device. 900uL. |
| Agilent 0905-1420 |
Agilent 79851A/52 Pump Module Parts and
Supplies Pump seal, polyethylene (for Normal Phase (Hexane) applications). HP
1050 Pump. |
| Agilent 0905-1516 |
Agilent Viton O-Ring For G1361A 1100 Series
Preparative Pump. 30mm. |
| Agilent 0905-1608 |
Agilent O-ring, Perfluoroelastomer 7.6 mm
id, 1.8 mm thick, white. |
| Agilent 0905-1609 |
Agilent O-ring, Perfluoroelastomer 1.1 mm
id, 1.3 mm thick, white. |
| Agilent 0905-1610 |
Agilent O-ring, Perfluoroelastomer 6.1 mm
id, 1.8 mm thick, white. |
| Agilent 0960-0376 |
Agilent General GC/MS Supplies and Electron
Multipliers Gauge tube for measuring vacuum. Cleaning and Maintenance
Supplies. |
| Agilent 0960-0799 |
Agilent HP 5989 MS Engine Parts and
Supplies Ion gauge tube, K-25 flange. Miscellaneous Parts and Supplies. |
| Agilent 1000-0488 |
Agilent 79854A Multiple Wavelength Detector
(MWD)/G1306A Diode-Array Detector (DAD) Parts and Supplies Window, Quartz. HP
1050 TI Detector. |
| Agilent 1000-0544 |
Agilent Macro Cells - with PTFE lid The
macro cell which is defined by DIN 58963 as a rectangular cell with an inner
width above 5 mm, has emerged as the standard for photometry. The most widely
used macro cell is a rectangular cell with outer dimensions of 45 x 12.5 mm
(height x width). |
| Agilent 1000-0822 |
Agilent Filter, 370nm cut off Filter, 370nm
cut off. |
| Agilent 1000-0953 |
Agilent Quartz Window For high pressure
flow cell. Conical. 7985/A MWD (multiple wavelength detector)/G1306A DAD
(diode-array detector) replacement item. |
| Agilent 10833B-2310 |
Agilent HPIB Cable 2m. |
| Agilent 10834A-2310 |
Agilent Adapter Extends GPIB
connector. |
| Agilent 112-2032 |
Agilent Column, Carbowax 20M, 0.25mm I.D. x
30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um):
0.25. Temperature Limits (oC): 60 to 220/240. |
| Agilent 112-2112 |
Agilent Column, CAM, 0.25mm I.D. x 15m
Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.25.
Temperature Limits (oC): 60 to 220/240, Unlike DB-WAX, CAM, Carbowax 20M and
OV-351 GC columns are not bonded and cross-linked, therefore J&W does not
recommend solvent rinsing. |
| Agilent 112-2132 |
Agilent Column, CAM, 0.25mm I.D. x 30m
Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.25.
Temperature Limits (oC): 60 to 220/240, Unlike DB-WAX, CAM, Carbowax 20M and
OV-351 GC columns are not bonded and cross-linked, therefore J&W does not
recommend solvent rinsing. |
| Agilent 112-2132E |
Agilent GC Column, DB-FFAP 30m, 0.32mm,
0.50um, 5in cage |
| Agilent 112-2133 |
Agilent CAM Stabilwax-DB; carbowax amine.
Base deactivated polyethlene glycol specifically designed for amine analysis.
0.25mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: 60 to
220[degree]C. |
| Agilent 112-2162 |
Agilent Column, CAM, 0.25mm I.D. x 60m
Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.25.
Temperature Limits (oC): 60 to 220/240, Unlike DB-WAX, CAM, Carbowax 20M and
OV-351 GC columns are not bonded and cross-linked, therefore J&W does not
recommend solvent rinsing. |
| Agilent 112-2532 |
Agilent Cyclodex-B* GC Column For
separating chiral compounds. Allows separation at temperatures below the
melting point of cyclodextrin. Phase composition: non-bonded proprietary phase
using permethylated beta-cyclodextrin. Temperature range: 10 to 230[degree]C.
ID: 0.25mm. Length: 30m. Thickness: 0.25um. |
| Agilent 112-2532E |
Agilent GC Column, DB-23 30m, 0.32mm,
0.25um, 5in cage |
| Agilent 112-2562 |
Agilent Cyclodex-B LIPODEX C. 10.5%
Beta-Cyclodextrin in DB-1701. Chiral separations without chiral specific
derivatization. Broad range of resolving potential. 0.25mm ID. Length: 6000mm.
Film: 0.25um. Temperature Range: 50 to 230[degree]C. |
| Agilent 112-5432 |
Agilent Column, SE-54, 0.25mm I.D. x 30m
Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.25.
Temperature Limits (oC): 0 to 325/350. |
| Agilent 112-5462 |
Agilent SE-54 GC Column (5%-phenyl)(1%
vinyl)-methylpolysiloxane. 0.25mm ID. Length: 6000mm. Film: 0.25um. Temperature
Range: 0 to 325[degree]C. |
| Agilent 112-6632 |
Agilent Column, CycloSil-B, 0.25mm I.D. x
30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um):
0.25. Temperature Limits (oC): 35 to 260/280, Similar Phases: LIPODEX C,
Rt-betaDEXm, beta-DEX 110, beta-DEX 120. |
| Agilent 112-8837E |
Agilent GC Column, DB-XLB 30m, 0.25mm,
0.50um, 5in cage |
| Agilent 112-8867E |
Agilent GC Column, HP-INNOWax 50m, 0.20mm,
0.4um, 5in cage |
| Agilent 112-88A7 |
Agilent HP-88 100m x 0.25mm ID, 0.2um. |
| Agilent 112-88A7E |
Agilent GC Column, ULTRA-2 50m, 0.20mm,
0.33um, 5in cage |
| Agilent 113-2032 |
Agilent Column, Carbowax 20M, 0.32mm I.D. x
30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um):
0.25. Temperature Limits (oC): 60 to 220/240. |
| Agilent 113-2132 |
Agilent CAM GC Column Specifically designed
for analysis of basic organic compounds, particularly primary amines, with
minimal tailing. Phase composition: non-bonded base deactivated polyethylene
glycol. Temperature range: 60 to 220[degree]C. ID: 0.32mm. Length: 30m. Film
Thickness: 0.25um. |
| Agilent 113-2132E |
Agilent CAM HP-basic wax. Wound on 127mm
cage. 0.32mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: 60 to
220[degree]C. |
| Agilent 113-2133 |
Agilent CAM Stabilwax-DB; carbowax amine.
Base deactivated polyethlene glycol specifically designed for amine analysis.
0.32mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: 60 to
220[degree]C. |
| Agilent 113-2133E |
Agilent GC Column, DB-WAXETR 30m, 0.53mm,
1.00um, 5in cage |
| Agilent 113-2532 |
Agilent Cyclodex-B LIPODEX C. 10.5%
Beta-Cyclodextrin in DB-1701. Chiral separations without chiral specific
derivatization. Broad range of resolving potential. 0.32mm ID. Length: 3000mm.
Film: 0.25um. Temperature Range: 50 to 230[degree]C. |
| Agilent 113-2532E |
Agilent GC Column, DB-225MS 30m, 0.25mm,
0.25um, 5in cage |
| Agilent 113-3032 |
Agilent Column, SE-30, 0.32mm I.D. x 30m
Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.25.
Temperature Limits (oC): 0 to 325/350. |
| Agilent 113-3112 |
Agilent Column, GS-CarbonPLOT, 0.32mm I.D.
x 15m Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um):
1.50. Temperature Limits (oC): -60 to 350/360, Similar Phases: Carbopack, CLOT,
Carboxen-1006 PLOT, CP-CarboPLOT P7. |
| Agilent 113-3132 |
Agilent Column, GS-CarbonPLOT, 0.32mm I.D.
x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um):
1.50. Temperature Limits (oC): -60 to 350/360, Similar Phases: Carbopack, CLOT,
Carboxen-1006 PLOT, CP-CarboPLOT P7. |
| Agilent 113-3133 |
Agilent Column, GS-CarbonPLOT, 0.32mm I.D.
x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um):
3.00. Temperature Limits (oC): -60 to 350/360, Similar Phases: Carbopack, CLOT,
Carboxen-1006 PLOT, CP-CarboPLOT P7. |
| Agilent 113-3162 |
Agilent Column, GS-CarbonPLOT, 0.32mm I.D.
x 60m Inner Diameter (mm I.D.): 0.32. Length (meter): 60. Film Thickness (um):
1.50. Temperature Limits (oC): -60 to 350/360, Similar Phases: Carbopack, CLOT,
Carboxen-1006 PLOT, CP-CarboPLOT P7. |
| Agilent 113-3432 |
Agilent GS-Q* GC Column Separates ethane,
ethylene and ethyne (acetylene), and various other gases including Freons* and
sulfides (except SO2). Replaces packed gas-solid columns. Phase composition:
porous divinylbenzene homopolymer. Temperature range: -60 to 250[degree}C.
I.D.: 0.32mm. Length: 30m. |
| Agilent 113-3432E |
Agilent GC Column, DB-FFAP 30m, 0.53mm,
1.00um, 5in cage |
| Agilent 113-4302 |
Agilent Column, GS-GasPro, 0.32mm I.D. x 5m
Inner Diameter (mm I.D.): 0.32. Length (meter): 5. Film Thickness (um): N/A.
Temperature Limits (oC): -80 to 260/300, Similar Phases: CP-Silica PLOT. |
| Agilent 113-4312 |
Agilent Column, GS-GasPro, 0.32mm I.D. x
15m Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um):
N/A. Temperature Limits (oC): -80 to 260/300, Similar Phases: CP-Silica
PLOT. |
| Agilent 113-4332 |
Agilent Column, GS-GasPro, 0.32mm I.D. x
30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um):
N/A. Temperature Limits (oC): -80 to 260/300, Similar Phases: CP-Silica
PLOT. |
| Agilent 113-4362 |
Agilent Column, GS-GasPro, 0.32mm I.D. x
60m Inner Diameter (mm I.D.): 0.32. Length (meter): 60. Film Thickness (um):
N/A. Temperature Limits (oC): -80 to 260/300, Similar Phases: CP-Silica
PLOT. |
| Agilent 113-5432 |
Agilent SE-54 GC Column (5%-phenyl)(1%
vinyl)-methylpolysiloxane. 0.32mm ID. Length: 3000mm. Film: 0.25um. Temperature
Range: 0 to 325[degree]C. |
| Agilent 113-6632 |
Agilent Column, CycloSil-B, 0.32mm I.D. x
30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um):
0.25. Temperature Limits (oC): 35 to 260/280, Similar Phases: LIPODEX C,
Rt-betaDEXm, beta-DEX 110, beta-DEX 120. |
| Agilent 115-2132 |
Agilent CAM Stabilwax-DB; carbowax amine.
Base deactivated polyethlene glycol specifically designed for amine analysis.
0.53mm ID. Length: 3000mm. Film: 1um. Temperature Range: 60 to
200[degree]C. |
| Agilent 115-3113 |
Agilent Column, GS-CarbonPLOT, 0.53mm I.D.
x 15m Inner Diameter (mm I.D.): 0.53. Length (meter): 15. Film Thickness (um):
3.00. Temperature Limits (oC): -60 to 350/360, Similar Phases: Carbopack, CLOT,
Carboxen-1006 PLOT, CP-CarboPLOT P7. |
| Agilent 115-3133 |
Agilent Column, GS-CarbonPLOT, 0.53mm I.D.
x 30m Inner Diameter (mm I.D.): 0.53. Length (meter): 30. Film Thickness (um):
3.00. Temperature Limits (oC): -60 to 350/360, Similar Phases: Carbopack, CLOT,
Carboxen-1006 PLOT, CP-CarboPLOT P7. |
| Agilent 115-3332 |
Agilent Column, GS-Alumina/KCl, 0.53mm I.D.
x 30m Inner Diameter (mm I.D.): 0.53. Length (meter): 30. Film Thickness (um):
N/A. Temperature Limits (oC): -60 to 200, Similar Phases: CP-Alumina/KCI,
HP-PLOT Al2O3, Rt-Alumina. |
| Agilent 115-3352 |
Agilent Column, GS-Alumina/KCl, 0.53mm I.D.
x 50m Inner Diameter (mm I.D.): 0.53. Length (meter): 50. Film Thickness (um):
N/A. Temperature Limits (oC): up to 200, Similar Phases: CP-Alumina/KCI,
HP-PLOT Al2O3, Rt-Alumina. |
| Agilent 115-3352E |
Agilent GS-ALUMINA/KC1 50m, 0.53mm, 5 in
cage |
| Agilent 115-3412 |
Agilent GS-Q CP PoraPLOT Q. Porous
divinylbenzene homopolymer. Separates ethane, ethylene, and ethyne. Useful in
separating various gases including freons. Not recommended for quantification
of polar compounds. 0.53mm ID. Length: 1500mm. Temperature Range: -60 to
250[degree]C. |
| Agilent 115-3422 |
Agilent GS-Q CP PoraPLOT Q. Porous
divinylbenzene homopolymer. Separates ethane, ethylene, and ethyne. Useful in
separating various gases including freons. Not recommended for quantification
of polar compounds. 0.53m ID. Length: 2500mm. Temperature Range: -60 to
250[degree]C. |
| Agilent 115-3432E |
Agilent GS-Q CP PoraPLOT Q. Wound on 127mm
cage. Porous divinylbenzene homopolymer. Separates ethane, ethylene, and
ethyne. Useful in separating various gases including freons. Not recommended
for quantification of polar compounds. 0.53mm ID. Length: 3000mm. Temperature
Range: -60 to 250[degree]C. |
| Agilent 115-34H2 |
Agilent GS-Q CP PoraPLOT Q. Porous
divinylbenzene homopolymer. Separates ethane, ethylene, and ethyne. Useful in
separating various gases including freons. Not recommended for quantification
of polar compounds. 0.53mm ID. Length: 1000mm. Temperature Range: -60 to
250[degree]C. |
| Agilent 115-34H2E |
Agilent GC Column, DB-5 10m, 0.10mm,
0.10um, 5in cage |
| Agilent 115-3532 |
Agilent Column, GS-Alumina, 0.53mm I.D. x
30m Inner Diameter (mm I.D.): 0.53. Length (meter): 30. Film Thickness (um):
30. Temperature Limits (oC): -60 to 200, Similar Phases: Al2O3/KCl,
Al2O3/Na2SO4, Rt-Alumina PLOT, Alumina PLOT. |
| Agilent 115-3532E |
Agilent GC Column, DB-1HT 30m, 0.32mm,
0.10um, 5in cage |
| Agilent 115-3552 |
Agilent Column, GS-Alumina, 0.53mm I.D. x
50m Inner Diameter (mm I.D.): 0.53. Length (meter): 50. Film Thickness (um):
50. Temperature Limits (oC): -60 to 200, Similar Phases: Al2O3/KCl,
Al2O3/Na2SO4, Rt-Alumina PLOT, Alumina PLOT. |
| Agilent 121-0122 |
Agilent Db-1Ms, 20M, 0.18Mm, 0.18Um |
| Agilent 121-0713 |
Agilent DB-1701 SPB-1701; CP-Sil 19 CB.
(14%-Cyanopropyl-phenyl)-methylpolysiloxane. Low to mid polarity. Sovent
rinsable. Bonded and cross-linked. 0.18mm ID. Length: 1000mm. Film: 0.4um.
Temperature Range: -20 to 280[degree]C. |
| Agilent 121-0722 |
Agilent Db-1701, 20M, 0.18Mm, 0.18Um |
| Agilent 121-1012 |
Agilent Column, DB-1, 0.18mm I.D. x 10m
Inner Diameter (mm I.D.): 0.18. Length (meter): 10. Film Thickness (um): 0.18.
Temperature Limits (oC): -60 to 325/350. |
| Agilent 121-1012E |
Agilent GC Column, DB-1 10m, 0.18mm,
0.18um, 5in cage |
| Agilent 121-1013 |
Agilent Column, DB-1, 0.18mm I.D. x 10m
Inner Diameter (mm I.D.): 0.18. Length (meter): 10. Film Thickness (um): 0.40.
Temperature Limits (oC): -60 to 325/350. |
| Agilent 121-1013E |
Agilent GC Column, DB-1 10m, 0.18mm,
0.40um, 5in cage |
| Agilent 121-101A |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.18mm ID.
Length: 1000mm. Film: 0.2um. Temperature Range: -60 to 325[degree]C. |
| Agilent 121-1022 |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.18mm ID.
Length: 2000mm. Film: 0.18um. Temperature Range: -60 to 325[degree]C. |
| Agilent 121-1022E |
Agilent GC Column, DB-5 25m, 0.20mm,
0.33um, 5in cage |
| Agilent 121-1023 |
Agilent Column, DB-1, 0.18mm I.D. x 20m
Inner Diameter (mm I.D.): 0.18. Length (meter): 20. Film Thickness (um): 0.40.
Temperature Limits (oC): -60 to 325/350. |
| Agilent 121-1043 |
Agilent DB*-1 GC Column A nonpolar column
for compounds with similar polarities and larger differences in boiling points.
Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods
504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.18mm.
Length 40m. Thickness 0.40um. |
| Agilent 121-1043E |
Agilent GC Column, DB-5 50m, 0.20mm,
0.33um, 5in cage |
| Agilent 121-1222 |
Agilent DB-XLB MDN-12. Exceptionally low
bleed. Low polarity. Designed to inhibit column bleed at high temperatures.
Excellent inertness for active compounds. Bonded and cross-linked. Solvent
rinsable. 0.18mm ID. Length: 2000mm. Film: 0.18um. Temperature Range: 30 to
340[degree]C. |
| Agilent 121-1232 |
Agilent Column, DB-XLB, 0.18mm I.D. x 30m
Inner Diameter (mm I.D.): 0.18. Length (meter): 30. Film Thickness (um): 0.18.
Temperature Limits (oC): 30 to 340/360, Similar Phases: PE-XLB, MDN-12. |
| Agilent 121-1324 |
Agilent DB*-624 GC Column Intermediate
polarity column for analysis of volatile priority pollutants. Specified in EPA
method 524.2. Phase composition: bonded 6% cyanopropyl-phenyl, 94%
dimethylpolysiloxane. Temperature range: -20 to 260[degree]C. I.D.:0.18mm.
Length: 20m. Film Thickness: 1.00um. |
| Agilent 121-1324E |
Agilent GC Column, HP-FFAP 25m, 0.20mm,
0.33um, 5in cage |
| Agilent 121-1524 |
Agilent DB-VRX Handles extensive target
list of volatiles. Run time: <30 minutes for optimum sample throughput. Low
polarity. Bonded and cross-linked. Solvent rinsable. 0.18mm ID. Length: 2000mm.
Film: 1um. Temperature Range: -10 to 260[degree]C. |
| Agilent 121-1544 |
Agilent GC Column |
| Agilent 121-1544E |
Agilent GC Column, HP-INNOWax 50m, 0.20mm,
0.2um, 5in cage |
| Agilent 121-1722 |
Agilent Column, DB-17, 0.18mm I.D. x 20m
Inner Diameter (mm I.D.): 0.18. Length (meter): 20. Film Thickness (um): 0.18.
Temperature Limits (oC): 40 to 280/300, Similar Phases: HP-17, RSL-300, Rtx-50,
PE-17, CC-17, 007-17 (MPS-50), SP-2250, HP-50+, SPB-50, ZB-50. |
| Agilent 121-1723 |
Agilent Column, DB-17, 0.18mm I.D. x 20m
Inner Diameter (mm I.D.): 0.18. Length (meter): 20. Film Thickness (um): 0.30.
Temperature Limits (oC): 40 to 280/300, Similar Phases: HP-17, RSL-300, Rtx-50,
PE-17, CC-17, 007-17 (MPS-50), SP-2250, HP-50+, SPB-50, ZB-50. |
| Agilent 121-2223 |
Agilent DB-225 SP-233; CP-Sil 43 CB.
(50%-cyanopropylphenyl)-dimethylpolysiloxane. Mid/high polarity. Excellent for
separations of cis- and trans-fatty acid methyl esters. Bonded and
cross-linked. Solvent rinsable. 0.18mm ID. Length: 2000mm. Film: 0.2um.
Temperature Range: 40 to 220[degree]C. |
| Agilent 121-2323 |
Agilent Column, DB-23, 0.18mm I.D. x 20m
Inner Diameter (mm I.D.): 0.18. Length (meter): 20. Film Thickness (um): 0.20.
Temperature Limits (oC): 40 to 250/260, Similar Phases: SP-2330, Rtx-2330,
007-23, AT-Silar, PE-23. |
| Agilent 121-3822 |
Agilent Db-35Ms, 20M, 0.18Mm, 0.18Um |
| Agilent 121-4722 |
Agilent Column, DB-17ms, 0.18mm I.D. x 20m
Inner Diameter (mm I.D.): 0.18. Length (meter): 20. Film Thickness (um): 0.18.
Temperature Limits (oC): 40 to 320/340, Similar Phases: HP-50+, Rtx-50, PE-17,
007-17, SP-2250, SPB-50, BPX-50, SPB-17. |
| Agilent 121-4722E |
Agilent GC Column, DB-5MS 20m, 0.18mm,
0.18um, 5in cage |
| Agilent 121-5012 |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.18mm ID. Length: 1000mm. Film: 0.18um. Temperature Range: 40 to
240[degree]C. |
| Agilent 121-5012E |
Agilent GC Column, DB-5 10m, 0.18mm,
0.18um, 5in cage |
| Agilent 121-5013 |
Agilent Column, DB-5, 0.18mm I.D. x 10m
Inner Diameter (mm I.D.): 0.18. Length (meter): 10. Film Thickness (um):
0.40. |
| Agilent 121-5022 |
Agilent Column, DB-5, 0.18mm I.D. x 20m
Inner Diameter (mm I.D.): 0.18. Length (meter): 20. Film Thickness (um):
0.18. |
| Agilent 121-5022E |
Agilent GC Column, DB-1 20m, 0.18mm,
0.18um, 5in cage |
| Agilent 121-5023 |
Agilent DB*-5 GC Column Nonpolar.
Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95%
methylpolysiloxane. Range -60 to 325/350[Degree]C. I.D. 0.18mm. Length 20m.
Thickness 0.4um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680,
1625, 1653, 8081, 8141, 8270, 8280. |
| Agilent 121-5042 |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.18mm ID. Length: 4000mm. Film: 0.18um. Temperature Range: 40 to
240[degree]C. |
| Agilent 121-5522 |
Agilent DB*-5ms GC Column Nonpolar. MS
certified. Improved signal-to-noise ratio for better sensitivity and mass
spectral integrity with basic and acidic analytes. Composition: bonded 5%
phenyl, 95% dimethylpolysiloxane. Temperature range -60 to 325/350[degree]C.
I.D. 0.18mm. Length 20m. Thickness 0.18um. |
| Agilent 121-5522E |
Agilent GC Column, DB-1 30m, 0.25mm,
0.10um, 5in cage |
| Agilent 121-5523 |
Agilent Db-5Ms, 20M, 0.18Mm, 0.36Um |
| Agilent 121-5542 |
Agilent Column, DB-5ms, 0.18mm I.D. x 40m
Inner Diameter (mm I.D.): 0.18. Length (meter): 40. Film Thickness (um): 0.18.
Temperature Limits (oC): -60 to 325/350, Similar Phases: Rtx-5MS, HP-5MS,
PTE-5, CP Sil 8 CBms, BPX-5, RH-5ms, HP-5 Trace. |
| Agilent 121-5621 |
Agilent Db-5.625, 20M, 0.18Mm, 0.18Um |
| Agilent 121-6822 |
Agilent Db-608, 20M, 0.18Mm, 0.18Um |
| Agilent 121-7012 |
Agilent DB-WAX HP-20M. Polyethylene glycol.
High polarity. Improves resolution of low boiling point analyses.
Column-to-column reproducibility. Bonded and cross-linked. Solvent rinsable.
0.18mm ID. Length: 1000mm. Film: 0.18um. Temperature Range: 20 to
250[degree]C. |
| Agilent 121-7022 |
Agilent DB-WAX HP-20M. Polyethylene glycol.
High polarity. Improves resolution of low boiling point analyses.
Column-to-column reproducibility. Bonded and cross-linked. Solvent rinsable.
0.18mm ID. Length: 2000mm. Film: 0.18um. Temperature Range: 20 to
250[degree]C. |
| Agilent 121-7023 |
Agilent DB*-Wax GC Column High polarity
column for analysis of solvents, aromatics, glycols, essential oils, flavors,
fragrances and volatile fatty acids. Phase composition: cross linked/surface
bonded polyethylene glycol. Range 20 to 240/250[degree]C. I.D. 0.18mm. Length
20m. Thickness 0.30um. |
| Agilent 121-7023E |
Agilent GC Column, DB-5 20m, 0.18mm,
0.18um, 5in cage |
| Agilent 121-7042 |
Agilent Db-Wax, 40M, 0.18Mm, 0.18Um |
| Agilent 121-7043 |
Agilent DB-WAX HP-20M. Polyethylene glycol.
High polarity. Improves resolution of low boiling point analyses.
Column-to-column reproducibility. Bonded and cross-linked. Solvent rinsable.
0.18mm ID. Length: 4000mm. Film: 0.30um. Temperature Range: 20 to
250[degree]C. |
| Agilent 122-0112E |
Agilent GC Column, GS-Q 10m, 0.53mm, 5in
cage |
| Agilent 122-0132E |
Agilent GC Column, DB-210 30m, 0.32mm,
0.50um, 5in cage |
| Agilent 122-0212 |
Agilent Column, DB-210, 0.25mm I.D. x 15m
Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.25.
Temperature Limits (oC): 45 to 240/260, Similar Phases: RSL-400, SP-2401,
Rtx-200. |
| Agilent 122-0232 |
Agilent Column, DB-210, 0.25mm I.D. x 30m
Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.25.
Temperature Limits (oC): 45 to 240/260, Similar Phases: RSL-400, SP-2401,
Rtx-200. |
| Agilent 122-0232E |
Agilent GC Column, DB-WAX 20m, 0.10mm,
0.20um, 5in cage |
| Agilent 122-0233 |
Agilent Column, DB-210, 0.25mm I.D. x 30m
Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.50.
Temperature Limits (oC): 45 to 240/260, Similar Phases: RSL-400, SP-2401,
Rtx-200. |
| Agilent 122-0712 |
Agilent Column, DB-1701, 0.25mm I.D. x 15m
Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.25.
Temperature Limits (oC): -20 to 280/300, Similar Phases to DB-1701: SPB-1701,
CP-Sil 19CB, Rtx-1701, BP-10, CB-1701, OV-1701, PE-1701, 007-1701, ZB-1701,
RH-1701. |
| Agilent 122-0713 |
Agilent DB-1701 SPB-1701; CP-Sil 19 CB.
(14%-Cyanopropyl-phenyl)-methylpolysiloxane. Low to mid polarity. Sovent
rinsable. Bonded and cross-linked. 0.25mm ID. Length: 1500mm. Film: 1um.
Temperature Range: -20 to 280[degree]C. |
| Agilent 122-0731 |
Agilent Column, DB-1701, 0.25mm I.D. x 30m
Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.15.
Temperature Limits (oC): -20 to 280/300, Similar Phases to DB-1701: SPB-1701,
CP-Sil 19CB, Rtx-1701, BP-10, CB-1701, OV-1701, PE-1701, 007-1701, ZB-1701,
RH-1701. |
| Agilent 122-0732 |
Agilent DB*-1701 GC Column Low-to-mid
polarity column with a dipole moment. Phase composition: bonded 14%
cyanopropylphenyl, 86% dimethylpolysiloxane. Temperature range: -20 to
280/300[degree]C. I.D.: 0.25mm. Length: 30m. Film Thickness: 0.25um. For EPA
methods 507, 508, 515, 515.2, 552, 552.1, and 8081. |
| Agilent 122-0732E |
Agilent GC Column |
| Agilent 122-0733 |
Agilent DB*-1701 GC Column Low-to-mid
polarity column with a dipole moment. Phase composition: bonded 14%
cyanopropylphenyl, 86% dimethylpolysiloxane. Temperature range: -20 to
280/300[degree]C. I.D.: 0.25mm. Length: 30m. Film Thickness: 1.00um. For EPA
methods 507, 508, 515, 515.2, 552, 552.1, and 8081. |
| Agilent 122-0733E |
Agilent GC Column, DB-FFAP 30m, 0.25mm,
0.25um, 5in cage |
| Agilent 122-0761 |
Agilent Column, DB-1701, 0.25mm I.D. x 60m
Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.15.
Temperature Limits (oC): -20 to 280/300, Similar Phases to DB-1701: SPB-1701,
CP-Sil 19CB, Rtx-1701, BP-10, CB-1701, OV-1701, PE-1701, 007-1701, ZB-1701,
RH-1701. |
| Agilent 122-0762 |
Agilent Column, DB-1701, 0.25mm I.D. x 60m
Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.25.
Temperature Limits (oC): -20 to 280/300, Similar Phases to DB-1701: SPB-1701,
CP-Sil 19CB, Rtx-1701, BP-10, CB-1701, OV-1701, PE-1701, 007-1701, ZB-1701,
RH-1701. |
| Agilent 122-0763 |
Agilent Column, DB-1701, 0.25mm I.D. x 60m
Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 1.00.
Temperature Limits (oC): -20 to 280/300, Similar Phases to DB-1701: SPB-1701,
CP-Sil 19CB, Rtx-1701, BP-10, CB-1701, OV-1701, PE-1701, 007-1701, ZB-1701,
RH-1701. |
| Agilent 122-0763E |
Agilent GC Column, DB-1701 50m, 0.32mm,
1.00um, 5in cage |
| Agilent 122-0766 |
Agilent DB-1701 SPB-1701; CP-Sil 19 CB.
(14%-Cyanopropyl-phenyl)-methylpolysiloxane. Low to mid polarity. Sovent
rinsable. Bonded and cross-linked. 0.25mm ID. Length: 6000mm. Film: 0.5um.
Temperature Range: -20 to 280[degree]C. |
| Agilent 122-1011 |
Agilent Column, DB-1, 0.25mm I.D. x 15m
Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.10.
Temperature Limits (oC): -60 to 325/350. |
| Agilent 122-1012 |
Agilent DB*-1 GC Column A nonpolar column
for compounds with similar polarities and larger differences in boiling points.
Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods
504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID: 0.25mm.
Length: 15m. Thickness 0.25um. |
| Agilent 122-1012E |
Agilent GC Column, DB-1 15m, 0.25mm,
0.25um, 5in cage |
| Agilent 122-1013 |
Agilent Column, DB-1, 0.25mm I.D. x 15m
Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 1.00.
Temperature Limits (oC): -60 to 325/350. |
| Agilent 122-1013E |
Agilent GC Column, DB-1 15m, 0.25mm,
1.00um, 5in cage |
| Agilent 122-1022 |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.25mm ID.
Length: 2500mm. Film: 0.25um. Temperature Range: -60 to 325[degree]C. |
| Agilent 122-1022E |
Agilent GC Column, DB-624 25m, 0.20mm,
1.12um, 5in cage |
| Agilent 122-1031 |
Agilent Column, DB-1, 0.25mm I.D. x 30m
Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.10.
Temperature Limits (oC): -60 to 325/350. |
| Agilent 122-1031E |
Agilent GC Column, HP-20M 25m, 0.32mm,
0.30um, 5in cage |
| Agilent 122-1032 |
Agilent DB*-1 GC Column A nonpolar column
for compounds with similar polarities and larger differences in boiling points.
Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods
504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.25mm.
Length 30m. Thickness 0.25um. |
| Agilent 122-1032E |
Agilent DB-1 HP-1; Ultra-1; SPB-1. Wound on
127mm cage. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose
column with wide range of applications. Bonded and cross-linked. Solvent
rinsable. 0.25mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: -60 to
325[degree]C. |
| Agilent 122-1032G |
Agilent DuraGuard GC Column Phase: DB-1.
I.D.: 0.25mm. Length: 30m. Film thickness: 0.25um. Features a built-in length
of deactivated fused silica tubing that eliminates problems with peak shape,
installation hassles, and leaks associated with unions. |
| Agilent 122-1033 |
Agilent DB*-1 GC Column A nonpolar column
for compounds with similar polarities and larger differences in boiling points.
Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods
504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.25mm.
Length 30m. Thickness 1.0um. |
| Agilent 122-1033E |
Agilent GC Column |
| Agilent 122-103E |
Agilent DB-1 HP-1; Ultra-1; SPB-1. Wound on
127mm cage. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose
column with wide range of applications. Bonded and cross-linked. Solvent
rinsable. 0.25mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: -60 to
325[degree]C. |
| Agilent 122-1052 |
Agilent DB-1 HP-1, Ultra-1, SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.25mm ID.
Length: 5000mm. Film: 0.25um. Temperature Range: -60 to 325[degree]C. |
| Agilent 122-1061 |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.25mm ID.
Length: 6000mm. Film: 0.1um. Temperature Range: -60 to 325[degree]C. |
| Agilent 122-1062 |
Agilent DB*-1 GC Column A nonpolar column
for compounds with similar polarities and larger differences in boiling points.
Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods
504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.25mm.
Length 60m. Thickness 0.25um. |
| Agilent 122-1062E |
Agilent GC Column, HP-1, 50m, 0.32mm,
1.05um, 5in cage |
| Agilent 122-1063 |
Agilent DB*-1 GC Column A nonpolar column
for compounds with similar polarities and larger differences in boiling points.
Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods
504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.25mm.
Length 60m. Thickness 1.00um. |
| Agilent 122-1063E |
Agilent GC Column, DB-WAXETR 50m, 0.32mm,
1.00um, 5in cage |
| Agilent 122-106E |
Agilent DB-1 HP-1; Ultra-1; SPB-1. Wound on
127mm cage. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose
column with wide range of applications. Bonded and cross-linked. Solvent
rinsable. 0.25mm ID. Length: 6000mm. Film: 0.5um. Temperature Range: -60 to
325[degree]C. |
| Agilent 122-106EE |
Agilent GC Column, HP-20M 50m, 0.32mm,
0.30um, 5in cage |
| Agilent 122-10A6 |
Agilent Column, DB-1, 0.25mm I.D. x 100m
Inner Diameter (mm I.D.): 0.25. Length (meter): 100. Film Thickness (um): 0.50.
Temperature Limits (oC): -60 to 325/350. |
| Agilent 122-10A6E |
Agilent DB-Petro Wound on 127mm cage.
0.25mm ID. Length: 10,000mm. Film: 0.5um. Temperature Range: -60 to
325[degree]C. |
| Agilent 122-10AE |
Agilent DB-1 HP-1; Ultra-1; SPB-1. Wound on
127mm cage. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose
column with wide range of applications. Bonded and cross-linked. Solvent
rinsable. 0.25mm ID. Length: 10,000mm. Film: 0.5um. Temperature Range: -60 to
325[degree]C. |
| Agilent 122-10G3 |
Agilent DuraGuard GC Column Phase: DB-1.
I.D.: 0.25mm. Length: 150m. Film thickness: 1.00um. Features a built-in length
of deactivated fused silica tubing that eliminates problems with peak shape,
installation hassles, and leaks associated with unions. |
| Agilent 122-1111 |
Agilent Column, DB-1ht, 0.25mm I.D. x 15m
Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.10.
Temperature Limits (oC): -60 to 400, Similar Phases: PE-1ht. |
| Agilent 122-1111E |
Agilent GC Column, DB-1MS 15m, 0.25mm,
0.25um, 5in cage |
| Agilent 122-1131 |
Agilent Column, DB-1ht, 0.25mm I.D. x 30m
Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.10.
Temperature Limits (oC): -60 to 400, Similar Phases: PE-1ht. |
| Agilent 122-1211 |
Agilent DB-XLB MDN-12. Exceptionally low
bleed. Low polarity. Designed to inhibit column bleed at high temperatures.
Excellent inertness for active compounds. Bonded and cross-linked. Solvent
rinsable. 0.25mm ID. Length: 1500mm. Film: 0.1um. Temperature Range: 30 to
340[degree]C. |
| Agilent 122-1212 |
Agilent DB-XLB MDN-12. Exceptionally low
bleed. Low polarity. Designed to inhibit column bleed at high temperatures.
Excellent inertness for active compounds. Bonded and cross-linked. Solvent
rinsable. 0.25mm ID. Length: 1500mm. Film: 0.25um. Temperature Range: 30 to
340[degree]C. |
| Agilent 122-1231 |
Agilent DB-XLB MDN-12. Exceptionally low
bleed. Low polarity. Designed to inhibit column bleed at high temperatures.
Excellent inertness for active compounds. Bonded and cross-linked. Solvent
rinsable. 0.25mm ID. Length: 3000mm. Film: 0.1um. Temperature Range: 30 to
340[degree]C. |
| Agilent 122-1231E |
Agilent GC Column, HP-1MS 30m, 0.25mm,
1.0um, 5in cage |
| Agilent 122-1232 |
Agilent DB-XLB MDN-12. Exceptionally low
bleed. Low polarity. Designed to inhibit column bleed at high temperatures.
Excellent inertness for active compounds. Bonded and cross-linked. Solvent
rinsable. 0.25mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: 30 to
340[degree]C. |
| Agilent 122-1232G |
Agilent DuraGuard GC Column Phase: DB-XLB.
I.D.: 0.25mm. Length: 30m. Film thickness: 0.25um. Features a built-in length
of deactivated fused silica tubing that eliminates problems with peak shape,
installation hassles, and leaks associated with unions. |
| Agilent 122-1233 |
Agilent DB-XLB MDN-12. Exceptionally low
bleed. Low polarity. Designed to inhibit column bleed at high temperatures.
Excellent inertness for active compounds. Bonded and cross-linked. Solvent
rinsable. 0.25mm ID. Length: 3000mm. Film: 1um. Temperature Range: 30 to
340[degree]C. |
| Agilent 122-1236 |
Agilent DB-XLB MDN-12. Exceptionally low
bleed. Low polarity. Designed to inhibit column bleed at high temperatures.
Excellent inertness for active compounds. Bonded and cross-linked. Solvent
rinsable. 0.25mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: 30 to
340[degree]C. |
| Agilent 122-1262 |
Agilent Column, DB-XLB, 0.25mm I.D. x 60m
Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.25.
Temperature Limits (oC): 30 to 340/360, Similar Phases: PE-XLB, MDN-12. |
| Agilent 122-1262E |
Agilent GC Column, HP-5MS 60m, 0.25mm,
0.25um, 5in cage |
| Agilent 122-1332 |
Agilent DB-1301 Rtx-1301; PE-1301.
(6%-cyanopropyl-phenyl) methylpolysiloxane. Low/midpolarity. Bonded and
cross-linked. Solvent rinsable. 0.25mm ID. Length: 3000mm. Film: 0.25um.
Temperature Range: -20 to 280[degree]C. |
| Agilent 122-1332E |
Agilent DB-1301 30m, 0.25mm, 0.25um, 5 inch
cage |
| Agilent 122-1333 |
Agilent Column, DB-1301, 0.25mm I.D. x 30m
Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 1.00.
Temperature Limits (oC): -20 to 280/300, Similar Phases to DB-1301: Rtx-1301,
PE-1301, HP-1301. |
| Agilent 122-1333E |
Agilent GC Column, DB-1701 30m, 0.25mm,
1.00um, 5in cage |
| Agilent 122-1334 |
Agilent DB*-624 GC Column Intermediate
polarity column for the analysis of volatile priority pollutants. Specified in
EPA method 524.2. Phase composition: bonded 6% cyanopropyl-phenyl, 94%
dimethylpolysiloxane. Temperature range: -20 to 260[degree]C. I.D.: 0.25mm.
Length: 30m. Film Thickness: 1.40um. |
| Agilent 122-1334E |
Agilent GC Column |
| Agilent 122-1362 |
Agilent DB-1301 Rtx-1301; PE-1301.
(6%-cyanopropyl-phenyl) methylpolysiloxane. Low/midpolarity. Bonded and
cross-linked. Solvent rinsable. 0.25mm ID. Length: 6000mm. Film: 0.25um.
Temperature Range: -20 to 280[degree]C. |
| Agilent 122-1363 |
Agilent Column, DB-1301, 0.25mm I.D. x 60m
Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 1.00.
Temperature Limits (oC): -20 to 280/300, Similar Phases to DB-1301: Rtx-1301,
PE-1301, HP-1301. |
| Agilent 122-1363E |
Agilent GC Column |
| Agilent 122-1364 |
Agilent Column, DB-624, 0.25 x 60m Diameter
(mm I.D.): 0.25. Inner Length (meter): 60. Film Thickness (um): 1.40.
Temperature Limits (oC): -20 to 260, Similar Phases: VOCOL, NON-PAKD, AT-624,
Rtx-Volatiles, Rtx-502.2, PE-624, PE-502, 007-624, 007-502, HP-624, CP-624,
ZB-624. |
| Agilent 122-1364E |
Agilent GC Column |
| Agilent 122-1534 |
Agilent DB*-VRX GC Column Low polarity. For
optimum resolution of volatiles and separation of the following coeluting
compounds while maintaining good peak shape: m- and p-xylene; and
1,1,2,2-tetrachloroethane and o-xylene. Temperature range: -20 to 260[degree]C.
ID: 0.25mm. Length: 30m. Thickness: 1.40um. |
| Agilent 122-1564 |
Agilent DB*-VRX GC Column Low polarity. For
optimum resolution of volatiles and separation of the following coeluting
compounds while maintaining good peak shape: m- and p-xylene; and
1,1,2,2-tetrachloroethane and o-xylene. Temperature range: -20 to 260[degree]C.
ID: 0.25mm. Length: 60m. Thickness: 1.40um. |
| Agilent 122-1564E |
Agilent DB-VRX Wound on 127mm cage. Handles
extensive target list of volatiles. Run time: <30 minutes for optimum sample
throughput. Low polarity. Bonded and cross-linked. Solvent rinsable. 0.25mm ID.
Length: 6000mm. Film: 1.4um. Temperature Range: -10 to 260[degree]C. |
| Agilent 122-1711 |
Agilent DB-17 HP-50+; Rtx-50.
(50%-phenyl)-methylpolysiloxane. Midpolarity. Excellent for confirmational
analyses. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 1500mm.
Film: 0.15um. Temperature Range: 40 to 280[degree]C. |
| Agilent 122-1711E |
Agilent GC Column, DB-17 15m, 0.25mm,
0.15um, 5in cage |
| Agilent 122-1712 |
Agilent DB*-17 GC Column Intermediate
polarity column. Use as a confirmation column for steroids, pesticides,
herbicides, and drugs. Phase composition: bonded 50% diphenyl, 50%
dimethylpolysiloxane. Temperature range: 40 to 280[degree]C. I.D.: 0.25mm.
Length: 15m. Film Thickness: 0.25um. |
| Agilent 122-1713 |
Agilent DB-17 HP-50+; Rtx-50.
(50%-phenyl)-methylpolysiloxane. Midpolarity. Excellent for confirmational
analyses. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 1500mm.
Film: 0.5um. Temperature Range: 40 to 280[degree]C. |
| Agilent 122-1713E |
Agilent GC Column, DB-17 15m, 0.25mm,
0.50um, 5in cage |
| Agilent 122-1731 |
Agilent Column, DB-17, 0.25mm I.D. x 30m
Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.15.
Temperature Limits (oC): 40 to 280/300, Similar Phases: HP-17, RSL-300, Rtx-50,
PE-17, CC-17, 007-17 (MPS-50), SP-2250, HP-50+, SPB-50, ZB-50. |
| Agilent 122-1731E |
Agilent GC Column, DB-17MS 20m, 0.18mm,
0.18um, 5in cage |
| Agilent 122-1732 |
Agilent DB*-17 GC Column Intermediate
polarity column. Use as a confirmation column for steroids, pesticides,
herbicides, and drugs. Phase composition: bonded 50% diphenyl, 50%
dimethylpolysiloxane. Temperature range: 40 to 280[degree]C. I.D.: 0.25mm.
Length: 30m. Film Thickness: 0.25um. |
| Agilent 122-1732E |
Agilent GC Column, DB-17 30m, 0.25mm,
0.15um, 5in cage |
| Agilent 122-1733 |
Agilent DB*-17 GC Column Intermediate
polarity column. Use as a confirmation column for steroids, pesticides,
herbicides, and drugs. Phase composition: bonded 50% diphenyl, 50%
dimethylpolysiloxane. Temperature range: 40 to 280[degree]C. I.D.: 0.25mm.
Length: 30m. Film Thickness: 0.50um. |
| Agilent 122-1762 |
Agilent Column, DB-17, 0.25mm I.D. x 60m
Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.25.
Temperature Limits (oC): 40 to 280/300, Similar Phases: HP-17, RSL-300, Rtx-50,
PE-17, CC-17, 007-17 (MPS-50), SP-2250, HP-50+, SPB-50, ZB-50. |
| Agilent 122-1811 |
Agilent Column, DB-17ht, 0.25mm I.D. x 15m
Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.15.
Temperature Limits (oC): 40 to 340/365, Similar Phases: Rtx-65TG, PE-17ht. |
| Agilent 122-1831 |
Agilent Column, DB-17ht, 0.25mm I.D. x 30m
Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.15.
Temperature Limits (oC): 40 to 340/365, Similar Phases: Rtx-65TG, PE-17ht. |
| Agilent 122-1932 |
Agilent Column, DB-35, 0.25mm I.D. x 30m
Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.25.
Temperature Limits (oC): 40 to 300/320, Similar Phases: Rtx-35, SPB-35, AT-35,
Sup-Herb, PE-35. |
| Agilent 122-1962 |
Agilent DB-35 Rtx-35; SPB-35.
(35%-phenyl)-methylpolysiloxane. Midpolarity. Low bleed. Inert to active
solutes. Ideal for confirmational analyses. Bonded and cross-linked. Solvent
rinsable. 0.25mm ID. Length: 6000mm. Film: 0.25um. Temperature Range: 40 to
300[degree]C. |
| Agilent 122-2032 |
Agilent Column, DB-200, 0.25mm I.D. x 30m
Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.25.
Temperature Limits (oC): 30 to 300/320, Similar Phases: Rtx-200. |
| Agilent 122-2033 |
Agilent Column, DB-200, 0.25mm I.D. x 30m
Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.50.
Temperature Limits (oC): 30 to 300/320, Similar Phases: Rtx-200. |
| Agilent 122-2212 |
Agilent Column, DB-225, 0.25mm I.D. x 15m
Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.25.
Temperature Limits (oC): 40 to 220/240, Similar Phases: HP-225, SP-2330, CP-Sil
43CB, RSL-500, Rtx-225, BP-225, CB-225, OV-225, PE-225, 007-225. |
| Agilent 122-2212E |
Agilent GC Column, DB-225, 15m, 0.25mm,
0.25um, 5in cage |
| Agilent 122-2231 |
Agilent Column, DB-225, 0.25mm I.D. x 30m
Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.15.
Temperature Limits (oC): 40 to 220/240, Similar Phases: HP-225, SP-2330, CP-Sil
43CB, RSL-500, Rtx-225, BP-225, CB-225, OV-225, PE-225, 007-225. |
| Agilent 122-2232 |
Agilent Column, DB-225, 0.25mm I.D. x 30m
Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.25.
Temperature Limits (oC): 40 to 220/240, Similar Phases: HP-225, SP-2330, CP-Sil
43CB, RSL-500, Rtx-225, BP-225, CB-225, OV-225, PE-225, 007-225. |
| Agilent 122-2312 |
Agilent Column, DB-23, 0.25mm I.D. x 15m
Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.25.
Temperature Limits (oC): 40 to 250/260, Similar Phases: SP-2330, Rtx-2330,
007-23, AT-Silar, PE-23. |
| Agilent 122-2312E |
Agilent GC Column, DB-23 15m, 0.25mm,
0.25um, 5in cage |
| Agilent 122-2331 |
Agilent Column, DB-23, 0.25mm I.D. x 30m
Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.15.
Temperature Limits (oC): 40 to 250/260, Similar Phases: SP-2330, Rtx-2330,
007-23, AT-Silar, PE-23. |
| Agilent 122-2332 |
Agilent Column, DB-23, 0.25mm I.D. x 30m
Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.25.
Temperature Limits (oC): 40 to 250/260, Similar Phases: SP-2330, Rtx-2330,
007-23, AT-Silar, PE-23. |
| Agilent 122-2332E |
Agilent GC Column, DB-WAXETR 30m, 0.25mm,
0.50um, 5in cage |
| Agilent 122-2361 |
Agilent Column, DB-23, 0.25mm I.D. x 60m
Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.15.
Temperature Limits (oC): 40 to 250/260, Similar Phases: SP-2330, Rtx-2330,
007-23, AT-Silar, PE-23. |
| Agilent 122-2361E |
Agilent GC Column, DB-WAX 60m, 0.25mm,
0.50um, 5in cage |
| Agilent 122-2362 |
Agilent Column, DB-23, 0.25mm I.D. x 60m
Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.25.
Temperature Limits (oC): 40 to 250/260, Similar Phases: SP-2330, Rtx-2330,
007-23, AT-Silar, PE-23. |
| Agilent 122-2362E |
Agilent GC Column, DB-WAXETR 60m, 0.25mm,
0.25um, 5in cage |
| Agilent 122-2461 |
Agilent DB-Dioxin SP-2331; Rtx-2332.
Engineered for the analysis of polychlorinated dibenzodioxins and
dibenzofurans. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length:
6000mm. Film: 0.15um. Temperature Range: 40 to 250[degree]C. |
| Agilent 122-2462 |
Agilent Column, DB-Dioxin, 0.25mm I.D. x
60m Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um):
0.25. Temperature Limits (oC): 40 to 250/270, Similar Phases:SP-2331, 007-23,
Rtx-2332, CP Sil 88. |
| Agilent 122-2912 |
Agilent DB-225ms HP-225. Equivalent to
(50%-cyanopropylphenyl)-dimethylpolysiloxane. Mid/high polarity. For
separations of cis- and trans-fatty acid methyl esters. Bonded and
cross-linked. Solvent rinsable. 0.25mm ID. Length: 1500mm. Film: 0.25um.
Temperature Range: 40 to 240[degree]C. |
| Agilent 122-2932 |
Agilent DB-225ms HP-225. Equivalent to
(50%-cyanopropylphenyl)-dimethylpolysiloxane. Mid/high polarity. For
separations of cis- and trans-fatty acid methyl esters. Bonded and
cross-linked. Solvent rinsable. 0.25mm ID. Length: 3000mm. Film: 0.25um.
Temperature Range: 40 to 240[degree]C. |
| Agilent 122-2932E |
Agilent GC Column, DB-XLB 30m, 0.25mm,
0.10um, 5in cage |
| Agilent 122-2962 |
Agilent DB-225ms HP-225. Equivalent to
(50%-cyanopropylphenyl)-dimethylpolysiloxane. Mid/high polarity. For
separations of cis- and trans-fatty acid methyl esters. Bonded and
cross-linked. Solvent rinsable. 0.25mm ID. Length: 6000mm. Film: 0.25um.
Temperature Range: 40 to 240[degree]C. |
| Agilent 122-3212 |
Agilent DB-FFAP Stabilwax-DA, HP-FFAP.
Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed
for the analysis of volatile fatty acids and phenols. Bonded and cross-linked.
Solvent rinsable. 0.25mm ID. Length: 1500mm. Film: 0.25um. Temperature Range:
40 to 250[degree]C. |
| Agilent 122-3232 |
Agilent DB*-FFAP GC Column High polarity
column for analysis of volatile fatty acids and phenols. Phase composition:
cross-linked/surface bonded nitroterephthalic acid modified polyethylene glycol
stationary phase. Temperature range: 40 to 250[degree]C. I.D.: 0.25mm. Length:
30m. Film Thickness: 0.25um. |
| Agilent 122-3232E |
Agilent GC Column, DB-23 30m, 0.25mm,
0.25um, 5in cage |
| Agilent 122-3233 |
Agilent DB-FFAP Stabilwax-DA, HP-FFAP.
Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed
for the analysis of volatile fatty acids and phenols. Bonded and cross-linked.
Solvent rinsable. 0.25mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: 40
to 250[degree]C. |
| Agilent 122-3262 |
Agilent DB-FFAP Stabilwax-DA, HP-FFAP.
Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed
for the analysis of volatile fatty acids and phenols. Bonded and cross-linked.
Solvent rinsable. 0.25mm ID. Length: 6000mm. Film: 0.25um. Temperature Range:
40 to 250[degree]C. |
| Agilent 122-3262E |
Agilent GC Column, HP-1, 60m, 0.25mm,
0.25um, 5in cage |
| Agilent 122-3263 |
Agilent DB-FFAP Stabilwax-DA, HP-FFAP.
Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed
for the analysis of volatile fatty acids and phenols. Bonded and cross-linked.
Solvent rinsable. 0.25mm ID. Length: 6000mm. Film: 0.5um. Temperature Range: 40
to 250[degree]C. |
| Agilent 122-3812 |
Agilent DB-35ms Rtx-35; SPB-35. Equivalent
to (35%-phenyl)-methylpolysiloxane. Midpolarity. Low bleed, excellent inertness
for active compounds. Ideal for confirmational analyses. Bonded and
cross-linked. Solvent rinsable. 0.25mm ID. Length: 1500mm. Film: 0.25um.
Temperature Range: 50 to 340[degree]C. |
| Agilent 122-3831 |
Agilent DB-35ms Rtx-35; SPB-35. Equivalent
to (35%-phenyl)-methylpolysiloxane. Midpolarity. Low bleed, excellent inertness
for active compounds. Ideal for confirmational analyses. Bonded and
cross-linked. Solvent rinsable. 0.25mm ID. Length: 3000mm. Film: 0.15um.
Temperature Range: 50 to 340[degree]C. |
| Agilent 122-3832 |
Agilent DB-35ms Rtx-35; SPB-35. Equivalent
to (35%-phenyl)-methylpolysiloxane. Midpolarity. Low bleed, excellent inertness
for active compounds. Ideal for confirmational analyses. Bonded and
cross-linked. Solvent rinsable. 0.25mm ID. Length: 3000mm. Film: 0.25um.
Temperature Range: 50 to 340[degree]C. |
| Agilent 122-3832E |
Agilent GC Column, DB-225 30m, 0.32mm,
0.25um, 5in cage |
| Agilent 122-3862 |
Agilent Column, DB-35ms, 0.25mm I.D. x 60m
Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.25.
Temperature Limits (oC): 50 to 340/360, Similar Phases: Rtx-35, SPB-35, AT-35,
Sup-Herb, PE-35ms, MDN-35. |
| Agilent 122-4711 |
Agilent Column, DB-17ms, 0.25mm I.D. x 15m
Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.15.
Temperature Limits (oC): 40 to 320/340, Similar Phases: HP-50+, Rtx-50, PE-17,
007-17, SP-2250, SPB-50, BPX-50, SPB-17. |
| Agilent 122-4712 |
Agilent Column, DB-17ms, 0.25mm I.D. x 15m
Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.25.
Temperature Limits (oC): 40 to 320/340, Similar Phases: HP-50+, Rtx-50, PE-17,
007-17, SP-2250, SPB-50, BPX-50, SPB-17. |
| Agilent 122-4731 |
Agilent Column, DB-17ms, 0.25mm I.D. x 30m
Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.15.
Temperature Limits (oC): 40 to 320/340, Similar Phases: HP-50+, Rtx-50, PE-17,
007-17, SP-2250, SPB-50, BPX-50, SPB-17. |
| Agilent 122-4732 |
Agilent Column, DB-17ms, 0.25mm I.D. x 30m
Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.25.
Temperature Limits (oC): 40 to 320/340, Similar Phases: HP-50+, Rtx-50, PE-17,
007-17, SP-2250, SPB-50, BPX-50, SPB-17. |
| Agilent 122-4732E |
Agilent DB-17MS 30m, 0.25mm, 0.25um, 5 inch
cage |
| Agilent 122-4762 |
Agilent Column, DB-17ms, 0.25mm I.D. x 60m
Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.25.
Temperature Limits (oC): 40 to 320/340, Similar Phases: HP-50+, Rtx-50, PE-17,
007-17, SP-2250, SPB-50, BPX-50, SPB-17. |
| Agilent 122-4762E |
Agilent GC Column, DB-5MS 60m, 0.25mm,
0.25um, 5in cage |
| Agilent 122-5011 |
Agilent DB*-5 GC Column Nonpolar.
Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95%
methylpolysiloxane. Range -60 to 325/350[Degree]C. I.D. 0.25mm. Length 15m.
Thickness 0.10um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680,
1625, 1653, 8081, 8141, 8270, 8280. |
| Agilent 122-5012 |
Agilent DB*-5 GC Column Nonpolar.
Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95%
methylpolysiloxane. Range -60 to 325/350[Degree]C. I.D. 0.25mm. Length 15m.
Thickness 0.25um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680,
1625, 1653, 8081, 8141, 8270, 8280. |
| Agilent 122-5012E |
Agilent GC Column, DB-5 15m, 0.25mm,
0.25um, 5in cage |
| Agilent 122-5013 |
Agilent Column, DB-5, 0.25mm I.D. x 15m
Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um):
1.00. |
| Agilent 122-5013E |
Agilent GC Column, DB-5 15m, 0.25mm,
1.00um, 5in cage |
| Agilent 122-501E |
Agilent DB-5 HP-5; Ultra-2; SP-B-5. Wound
on 127mm cage. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column
with wide range of applications. Low bleed. Bonded and cross-linked. Solvent
rinsable. 0.25mm ID. Length: 1500mm. Film: 0.5um. Temperature Range: -60 to
325[degree]C. |
| Agilent 122-5022 |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.25mm ID. Length: 2500mm. Film: 0.25um. Temperature Range: -60 to
325[degree]C. |
| Agilent 122-5031 |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.25mm ID. Length: 3000mm. Film: 0.1um. Temperature Range: -60 to
325[degree]C. |
| Agilent 122-5032 |
Agilent DB*-5 GC Column Nonpolar.
Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95%
methylpolysiloxane. Range -60 to 325/350[Degree]C. I.D. 0.25mm. Length 30m.
Thickness 0.25um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680,
1625, 1653, 8081, 8141, 8270, 8280. |
| Agilent 122-5032E |
Agilent DB-5 HP-5; Ultra-2; SP-B-5. Wound
on 127mm cage. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column
with wide range of applications. Low bleed. Bonded and cross-linked. Solvent
rinsable. 0.25mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: -60 to
325[degree]C. |
| Agilent 122-5033 |
Agilent DB*-5 GC Column Nonpolar.
Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95%
methylpolysiloxane. Range -60 to 325/350[Degree]C. I.D. 0.25mm. Length 30m.
Thickness 1um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680,
1625, 1653, 8081, 8141, 8270, 8280. |
| Agilent 122-5033E |
Agilent GC Column, DB-17 30m, 0.25mm,
0.25um, 5in cage |
| Agilent 122-503E |
Agilent DB-5 HP-5; Ultra-2; SP-B-5. Wound
on 127mm cage. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column
with wide range of applications. Low bleed. Bonded and cross-linked. Solvent
rinsable. 0.25mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: -60 to
325[degree]C. |
| Agilent 122-5052 |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.25mm ID. Length: 5000mm. Film: 0.25um. Temperature Range: -60 to
325[degree]C. |
| Agilent 122-5061 |
Agilent Column, DB-5, 0.25mm I.D. x 60m
Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um):
0.10. |
| Agilent 122-5062 |
Agilent DB*-5 GC Column Nonpolar.
Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95%
methylpolysiloxane. Range -60 to 325/350[Degree]C. I.D. 0.25mm. Length 60m.
Thickness 0.25um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680,
1625, 1653, 8081, 8141, 8270, 8280. |
| Agilent 122-5062E |
Agilent GC Column, DB-1 60m, 0.25mm,
0.25um, 5in cage |
| Agilent 122-5063 |
Agilent DB*-5 GC Column Nonpolar.
Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95%
methylpolysiloxane. Range -60 to 325/350[Degree]C. I.D. 0.25mm. Length 60m.
Thickness 1um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680,
1625, 1653, 8081, 8141, 8270, 8280. |
| Agilent 122-5063E |
Agilent GC Column, DB-1 60m, 0.25mm,
1.00um, 5in cage |
| Agilent 122-506E |
Agilent DB-5 HP-5; Ultra-2; SP-B-5. Wound
on 127mm cage. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column
with wide range of applications. Low bleed. Bonded and cross-linked. Solvent
rinsable. 0.25mm ID. Length: 6000mm. Film: 0.5um. Temperature Range: -60 to
325[degree]C. |
| Agilent 122-5511 |
Agilent Column, DB-5ms, 0.25mm I.D. x 15m
Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.10.
Temperature Limits (oC): -60 to 325/350, Similar Phases: Rtx-5MS, HP-5MS,
PTE-5, CP Sil 8 CBms, BPX-5, RH-5ms, HP-5 Trace. |
| Agilent 122-5512 |
Agilent DB*-5ms GC Column Nonpolar. MS
certified. Improved signal-to-noise ratio for better sensitivity and mass
spectral integrity with basic and acidic analytes. Composition: bonded 5%
phenyl, 95% dimethylpolysiloxane. Temperature range -60 to 325/350[degree]C.
I.D. 0.25mm. Length 15m. Thickness 0.25um. |
| Agilent 122-5512E |
Agilent DB-5MS 15m, 0.25mm, 0.25um, 5 inch
cage |
| Agilent 122-5513 |
Agilent Column, DB-5ms, 0.25mm I.D. x 15m
Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 1.00.
Temperature Limits (oC): -60 to 325/350, Similar Phases: Rtx-5MS, HP-5MS,
PTE-5, CP Sil 8 CBms, BPX-5, RH-5ms, HP-5 Trace. |
| Agilent 122-5516 |
Agilent DB-5ms Rtx-5ms; PTE-5. Phenyl
Arylene polymer equivalent to (5%-phenyl)-methylpolysiloxane. Non-polar. Low
bleed, excellent inertness for active compounds. Bonded and cross-linked.
Solvent rinsable. 0.25mm ID. Length: 1500mm. Film: 0.5um. Temperature Range:
-60 to 325[degree]C. |
| Agilent 122-5522 |
Agilent DB-5ms Rtx-5ms; PTE-5. Phenyl
Arylene polymer equivalent to (5%-phenyl)-methylpolysiloxane. Non-polar. Low
bleed, excellent inertness for active compounds. Bonded and cross-linked.
Solvent rinsable. 0.25mm ID. Length: 2500mm. Film: 0.25um. Temperature Range:
-60 to 325[degree]C. |
| Agilent 122-552A |
Agilent DB-5ms Rtx-5ms; PTE-5. Phenyl
Arylene polymer equivalent to (5%-phenyl)-methylpolysiloxane. Non-polar. Low
bleed, excellent inertness for active compounds. Bonded and cross-linked.
Solvent rinsable. 0.25mm ID. Length: 2500mm. Film: 0.4um. Temperature Range:
-60 to 325[degree]C. |
| Agilent 122-5531 |
Agilent Column, DB-5ms, 0.25mm I.D. x 30m
Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.10.
Temperature Limits (oC): -60 to 325/350, Similar Phases: Rtx-5MS, HP-5MS,
PTE-5, CP Sil 8 CBms, BPX-5, RH-5ms, HP-5 Trace. |
| Agilent 122-5532 |
Agilent DB*-5ms GC Column Nonpolar. MS
certified. Improved signal-to-noise ratio for better sensitivity and mass
spectral integrity with basic and acidic analytes. Composition: bonded 5%
phenyl, 95% dimethylpolysiloxane. Temperature range -60 to 325/350[degree]C.
I.D. 0.25mm. Length 30m. Thickness 0.25um. |
| Agilent 122-5532E |
Agilent GC Column, DB-1MS 30m, 0.25mm,
0.25um, 5in cage |
| Agilent 122-5532G |
Agilent DuraGuard GC Column Phase: DB-5ms.
I.D.: 0.25mm. Length: 30m. Film thickness: 0.25um. Features a built-in length
of deactivated fused silica tubing that eliminates problems with peak shape,
installation hassles, and leaks associated with unions. |
| Agilent 122-5533 |
Agilent DB*-5ms GC Column Nonpolar. MS
certified. Improved signal-to-noise ratio for better sensitivity and mass
spectral integrity with basic and acidic analytes. Composition: bonded 5%
phenyl, 95% dimethylpolysiloxane. Temperature range: -60 to 325/350[degree]C.
I.D. 0.25mm. Length 30m. Thickness 1.00um. |
| Agilent 122-5533E |
Agilent GC Column |
| Agilent 122-5533G |
Agilent DuraGuard GC Column Phase: DB-5ms.
I.D.: 0.25mm. Length: 30m. Film thickness: 1.00um. Features a built-in length
of deactivated fused silica tubing that eliminates problems with peak shape,
installation hassles, and leaks associated with unions. |
| Agilent 122-5536 |
Agilent DB*-5ms GC Column Nonpolar. MS
certified. Improved signal-to-noise ratio for better sensitivity and mass
spectral integrity with basic and acidic analytes. Composition: bonded 5%
phenyl, 95% dimethylpolysiloxane. Temperature range -60 to 325/350[degree]C.
I.D. 0.25mm. Length 30m. Thickness 0.50um. |
| Agilent 122-5536E |
Agilent GC Column, DB-35MS 30m, 0.25mm,
0.25um, 5in cage |
| Agilent 122-5536G |
Agilent DuraGuard GC Column Phase: DB-5ms.
I.D.: 0.25mm. Length: 30m. Film thickness: 0.50um. Features a built-in length
of deactivated fused silica tubing that eliminates problems with peak shape,
installation hassles, and leaks associated with unions. |
| Agilent 122-5552 |
Agilent DB-5ms Rtx-5ms; PTE-5. Phenyl
Arylene polymer equivalent to (5%-phenyl)-methylpolysiloxane. Non-polar. Low
bleed, excellent inertness for active compounds. Bonded and cross-linked.
Solvent rinsable. 0.25mm ID. Length: 5000mm. Film: 0.25um. Temperature Range:
-60 to 325[degree]C. |
| Agilent 122-5561 |
Agilent DB-5ms Rtx-5ms; PTE-5. Phenyl
Arylene polymer equivalent to (5%-phenyl)-methylpolysiloxane. Non-polar. Low
bleed, excellent inertness for active compounds. Bonded and cross-linked.
Solvent rinsable. 0.25mm ID. Length: 6000mm. Film: 0.1um. Temperature Range:
-60 to 325[degree]C. |
| Agilent 122-5562 |
Agilent DB*-5ms GC Column Nonpolar. MS
certified. Improved signal-to-noise ratio for better sensitivity and mass
spectral integrity with basic and acidic analytes. Composition: bonded 5%
phenyl, 95% dimethylpolysiloxane. Temperature range: -60 to 325/350[degree]C.
I.D. 0.25mm. Length 60m. Thickness 0.25um. |
| Agilent 122-5562E |
Agilent GC Column, DB-1 60m, 0.53mm,
1.50um, 5in cage |
| Agilent 122-5562G |
Agilent DuraGuard GC Column Phase: DB-5ms.
I.D.: 0.25mm. Length: 60m. Film thickness: 0.25um. Features a built-in length
of deactivated fused silica tubing that eliminates problems with peak shape,
installation hassles, and leaks associated with unions. |
| Agilent 122-5563 |
Agilent DB-5ms Rtx-5ms; PTE-5. Phenyl
Arylene polymer equivalent to (5%-phenyl)-methylpolysiloxane. Non-polar. Low
bleed, excellent inertness for active compounds. Bonded and cross-linked.
Solvent rinsable. 0.25mm ID. Length: 6000mm. Film: 1um. Temperature Range: -60
to 325[degree]C. |
| Agilent 122-5631 |
Agilent DB*-5.625 GC Column Nonpolar,
inert. For analyzing BNAs. Meet EPA semi-volatiles performance criteria for CLP
protocols and EPA methods 625, 1625, and 8270. Bonded 5% phenyl, 95%
methylpolysiloxane. Temperature range: -60 to 325/350[degree]C. I.D. 0.25mm.
Length 30m. Thickness 0.25um. |
| Agilent 122-5632 |
Agilent DB*-5.625 GC Column Nonpolar,
inert. For analyzing BNAs. Meet EPA semi-volatiles performance criteria for CLP
protocols and EPA methods 625, 1625, and 8270. Bonded 5% phenyl, 95%
methylpolysiloxane. Temperature range: -60 to 325/350[degree]C. I.D. 0.25mm.
Length 30m. Thickness 0.50um. |
| Agilent 122-5633 |
Agilent DB*-5.625 GC Column Nonpolar,
inert. For analyzing BNAs. Meet EPA semi-volatiles performance criteria for CLP
protocols and EPA methods 625, 1625, and 8270. Bonded 5% phenyl, 95%
methylpolysiloxane. Temperature range: -60 to 325/350[degree]C. I.D. 0.25mm.
Length 30m. Thickness 1um. |
| Agilent 122-5661 |
Agilent DB-5.625 XTI-5. Equivalent to
(5%-phenyl)-methylpolysiloxane. Non-polar. Processed to exhibit inertness for
EPA Semivolatiles Methods 625, 1625, 8270 and CLP protocols. Bonded and
cross-linked. Solvent rinsable. 0.25mm ID. Length: 6000mm. Film: 0.25um.
Temperature Range: -60 to 325[degree]C. |
| Agilent 122-5711 |
Agilent Column, DB-5ht, 0.25mm I.D. x 15m
Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.10.
Temperature Limits (oC): -60 to 400, Similar Phases: PE-5ht. |
| Agilent 122-5711E |
Agilent GC Column, DB-1HT 15m, 0.25mm,
0.10um, 5in cage |
| Agilent 122-5731 |
Agilent Column, DB-5ht, 0.25mm I.D. x 30m
Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.10.
Temperature Limits (oC): -60 to 400, Similar Phases: PE-5ht. |
| Agilent 122-6432 |
Agilent DX-4 15% dimethylpolysiloxane - 85%
polyethylene glycol. 0.25mm ID. Length: 3000mm. Film: 0.25um. Temperature
Range: 50 to 250[degree]C. |
| Agilent 122-6462 |
Agilent Column, DX-4, 0.25mm I.D. x 60m
Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.25.
Temperature Limits (oC): 50 to 250/270. |
| Agilent 122-6832 |
Agilent DB-608 SPB-608, NON-PAKD Pesticide.
Designed for analysis of chlorinated pesticides and PCBs. Excellent inertness
and recoveries without pesticide breakdown. Bonded and cross-linked. Solvent
rinsable. 0.25mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: 40 to
280[degree]C. |
| Agilent 122-7012 |
Agilent Column, DB-WAX, 0.25mm I.D. x 15m
Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.25.
Temperature Limits (oC): 20 to 250/260. |
| Agilent 122-7012E |
Agilent GC Column, DB-WAX 15m, 0.25mm,
0.25um, 5in cage |
| Agilent 122-7013 |
Agilent Column, DB-WAX, 0.25mm I.D. x 15m
Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.50.
Temperature Limits (oC): 20 to 240/250. |
| Agilent 122-7031 |
Agilent Column, DB-WAX, 0.25mm I.D. x 30m
Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.15.
Temperature Limits (oC): 20 to 250/260. |
| Agilent 122-7032 |
Agilent DB*-Wax GC Column High polarity
column for the analysis of solvents, aromatics, glycols, essential oils,
flavors, fragrances and volatile fatty acids. Phase composition: cross
linked/surface bonded polyethylene glycol. Range 20 to 250/260[degree]C. I.D.
0.25mm. Length 30m. Thickness 0.25um. |
| Agilent 122-7032E |
Agilent GC Column |
| Agilent 122-7033 |
Agilent DB*-Wax GC Column High polarity
column for the analysis of solvents, aromatics, glycols, essential oils,
flavors, fragrances and volatile fatty acids. Phase composition: cross
linked/surface bonded polyethylene glycol. Range 20 to 240/250[degree]C. I.D.
0.25mm. Length 30m. Thickness 0.50um. |
| Agilent 122-7033E |
Agilent GC Column |
| Agilent 122-7061 |
Agilent DB-WAX HP-20M; SUPELCOWAX 10.
Polyethylene glycol. High polarity. Improves resolution of low boiling point
analyses. Column-to-column reproducibility. Bonded and cross-linked. Solvent
rinsable. 0.25mm ID. Length: 6000mm. Film: 0.15um. Temperature Range: 20 to
250[degree]C. |
| Agilent 122-7062 |
Agilent DB*-Wax GC Column High polarity
column for the analysis of solvents, aromatics, glycols, essential oils,
flavors, fragrances and volatile fatty acids. Phase composition: cross
linked/surface bonded polyethylene glycol. Range 20 to 250/260[degree]C. I.D.
0.25mm. Length 60m. Thickness 0.25um. |
| Agilent 122-7062E |
Agilent GC Column, DB-1 60m, 0.25mm, 0.5um,
5in cage |
| Agilent 122-7063 |
Agilent Column, DB-WAX, 0.25mm I.D. x 60m
Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.50.
Temperature Limits (oC): 20 to 240/250. |
| Agilent 122-7063E |
Agilent GC Column, DB-5 60m, 0.25mm,
0.25um, 5in cage |
| Agilent 122-7332 |
Agilent Column, DB-WAXetr, 0.25mm I.D. x
30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um):
0.25. Temperature Limits (oC): 30 to 260/280, Similar Phases: HP-20M,
SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW,
007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX. |
| Agilent 122-7332E |
Agilent GC Column, DB-5 30m, 0.25mm,
1.00um, 5in cage |
| Agilent 122-7333 |
Agilent Column, DB-WAXetr, 0.25mm I.D. x
30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um):
0.50. Temperature Limits (oC): 30 to 250/260, Similar Phases: HP-20M,
SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW,
007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX. |
| Agilent 122-7333E |
Agilent GC Column, DB-WAXETR 30m, 0.25mm,
0.25um, 5in cage |
| Agilent 122-7362 |
Agilent Column, DB-WAXetr, 0.25mm I.D. x
60m Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um):
0.25. Temperature Limits (oC): 30 to 260/280, Similar Phases: HP-20M,
SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW,
007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX. |
| Agilent 122-7362E |
Agilent GC Column, DB-5 60m, 0.25mm,
1.00um, 5in cage |
| Agilent 122-7363 |
Agilent DB-WAXetr HP-20M; SUPELCOWAX 10.
Polyethylene glycol. Extended temperature range. High polarity. Excellent
column-to-column repeatability. Bonded and cross-linked. Solvent rinsable.
0.25mm ID. Length: 6000mm. Film: 0.5um. Temperature Range: 30 to
250[degree]C. |
| Agilent 122-7732 |
Agilent DB-1701P SPB-1701P.
(14%-cyanopropyl-phenyl)-methylpolysiloxane. Low/midpolarity. Designed and
processed for the analysis of organochlorine pesticides. Bonded and
cross-linked. Solvent rinsable. 0.25mm ID. Length: 3000mm. Film: 0.25um.
Temperature Range: -20 to 280[degree]C. |
| Agilent 123-0213 |
Agilent DB-210 SP-210.
(50%-Trifluoropropyl)-methylpolysiloxane. High polarity, excellent for US EPA
Methods 8140 and 609. Bonded and cross-linked. 0.32mm ID. Length: 1500mm. Film:
0.5um. Temperature Range: 45 to 240[degree]C. |
| Agilent 123-0232 |
Agilent Column, DB-210, 0.32mm I.D. x 30m
Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.25.
Temperature Limits (oC): 45 to 240/260, Similar Phases: RSL-400, SP-2401,
Rtx-200. |
| Agilent 123-0232E |
Agilent GC Column, CYCLODEX-B 30m, 0.25mm,
0.25um, 5in cage |
| Agilent 123-0233 |
Agilent DB*-210 GC Column High polarity
column for organophosphorus pesticides, nitroaromatics, herbicides,
disinfection by-products. Bonded 50% trifluoropropyl, 50% methylpolysiloxane.
Range: 45 to 240[degree]C. ID: 0.32mm. Length: 30m. Film Thickness: 0.50um. For
EPA methods 551, 552, 552.1, and 8141. |
| Agilent 123-0233E |
Agilent GC Column, CAM 30m, 0.25mm, 0.25um,
5in cage |
| Agilent 123-0712 |
Agilent Column, DB-1701, 0.32mm I.D. x 15m
Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 0.25.
Temperature Limits (oC): -20 to 280/300, Similar Phases to DB-1701: SPB-1701,
CP-Sil 19CB, Rtx-1701, BP-10, CB-1701, OV-1701, PE-1701, 007-1701, ZB-1701,
RH-1701. |
| Agilent 123-0713 |
Agilent DB-1701 SPB-1701, CP-Sil 19 CB.
(14%-Cyanopropyl-phenyl)-methylpolysiloxane. Low to mid polarity. Solvent
rinsable. Bonded and cross-linked. 0.32mm ID. Length: 1500mm. Film: 1um.
Temperature Range: -20 to 280[degree]C. |
| Agilent 123-0731 |
Agilent DB*-1701 GC Column Low-to-mid
polarity column with a dipole moment. Phase composition: bonded 14%
cyanopropylphenyl, 86% dimethylpolysiloxane. Temperature range: -20 to
280/300[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness: 0.15um. For EPA
methods 507, 508, 515, 515.2, 552, 552.1, and 8081. |
| Agilent 123-0732 |
Agilent DB*-1701 GC Column Low-to-mid
polarity column with a dipole moment. Phase composition: bonded 14%
cyanopropylphenyl, 86% dimethylpolysiloxane. Temperature range: -20 to
280/300[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness: 0.25um. For EPA
methods 507, 508, 515, 515.2, 552, 552.1, and 8081. |
| Agilent 123-0732E |
Agilent GC Column |
| Agilent 123-0733 |
Agilent DB*-1701 GC Column Low-to-mid
polarity column with a dipole moment. Phase composition: bonded 14%
cyanopropylphenyl, 86% dimethylpolysiloxane. Temperature range: -20 to
280/300[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness: 1.00um. For EPA
methods 507, 508, 515, 515.2, 552, 552.1, and 8081. |
| Agilent 123-0733E |
Agilent GC Column |
| Agilent 123-0753 |
Agilent DB-1701 SPB-1701, CP-Sil 19 CB.
(14%-Cyanopropyl-phenyl)-methylpolysiloxane. Low to mid polarity. Solvent
rinsable. Bonded and cross-linked. 0.32mm ID. Length: 5000mm. Film: 1um.
Temperature Range: -20 to 280[degree]C. |
| Agilent 123-0753E |
Agilent GC Column, DB-WAX 60m, 0.25mm,
0.25um, 5in cage |
| Agilent 123-0762 |
Agilent DB-1701 SPB-1701; CP-Sil 19 CB.
(14%-Cyanopropyl-phenyl)-methylpolysiloxane. Low to mid polarity. Solvent
rinsable. Bonded and cross-linked. 0.32mm ID. Length: 6000mm. Film: 0.25um.
Temperature Range: -20 to 280[degree]C. |
| Agilent 123-0762E |
Agilent GC Column, DB-1 60m, 0.53mm,
5.00um, 5in cage |
| Agilent 123-0763 |
Agilent Column, DB-1701, 0.32mm I.D. x 60m
Inner Diameter (mm I.D.): 0.32. Length (meter): 60. Film Thickness (um): 1.00.
Temperature Limits (oC): -20 to 280/300, Similar Phases to DB-1701: SPB-1701,
CP-Sil 19CB, Rtx-1701, BP-10, CB-1701, OV-1701, PE-1701, 007-1701, ZB-1701,
RH-1701. |
| Agilent 123-0763E |
Agilent DB-1701 Wound on 127mm
cage.SPB-1701; CP-Sil 19 CB. (14%-Cyanopropyl-phenyl)-methylpolysiloxane. Wound
on 127mm cage. Low to mid polarity. Solvent rinsable. Bonded and cross-linked.
0.32mm ID. Length: 6000mm. Film: 1um. Temperature Range: -20 to
280[degree]C. |
| Agilent 123-100E |
Agilent DB-1 10m, 0.32mm, 0.50 um |
| Agilent 123-1011 |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID.
Length: 1500mm. Film: 0.1um. Temperature Range: -60 to 325[degree]C. |
| Agilent 123-1012 |
Agilent DB*-1 GC Column A nonpolar column
for compounds with similar polarities and larger differences in boiling points.
Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods
504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.32mm.
Length 15m. Thickness: 0.25um. |
| Agilent 123-1012E |
Agilent GC Column, DB-1 15m, 0.32mm,
0.25um, 5in cage |
| Agilent 123-1013 |
Agilent DB*-1 GC Column A nonpolar column
for compounds with similar polarities and larger differences in boiling points.
Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods
504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.32mm.
Length 15m. Thickness 1.00um. |
| Agilent 123-1014 |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID.
Length: 1500mm. Film: 3um. Temperature Range: -60 to 280[degree]C. |
| Agilent 123-1015E |
Agilent GC Column, DB-1 15m, 0.32mm,
5.00um, 5in cage |
| Agilent 123-1022 |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID.
Length: 2500mm. Film: 0.25um. Temperature Range: -60 to 325[degree]C. |
| Agilent 123-1026 |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID.
Length: 2500mm. Film: 0.52um. Temperature Range: -60 to 325[degree]C. |
| Agilent 123-1027 |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID.
Length: 2500mm. Film: 0.12um. Temperature Range: -60 to 325[degree]C. |
| Agilent 123-102F |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID.
Length: 2500mm. Film: 1.05um. Temperature Range: -60 to 325[degree]C. |
| Agilent 123-1031 |
Agilent Column, DB-1, 0.32mm I.D. x 30m
Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.10.
Temperature Limits (oC): -60 to 325/350. |
| Agilent 123-1032 |
Agilent DB*-1 GC Column A nonpolar column
for compounds with similar polarities and larger differences in boiling points.
Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods
504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.32mm.
Length 30m. Thickness 0.25um. |
| Agilent 123-1032E |
Agilent GC Column, HP-1 30m, 0.32mm, 0.1um,
5in cage |
| Agilent 123-1033 |
Agilent DB*-1 GC Column A nonpolar column
for compounds with similar polarities and larger differences in boiling points.
Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods
504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.32mm.
Length 30m. Thickness: 1.00um. |
| Agilent 123-1033E |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Wound on 127mm cage. Non-polar. Excellent general purpose
column with wide range of applications. Bonded and cross-linked. Solvent
rinsable. 0.32mm ID. Length: 3000mm. Film: 1um. Temperature Range: -60 to
325[degree]C. |
| Agilent 123-1034 |
Agilent Column, DB-1, 0.32mm I.D. x 30m
Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 3.00.
Temperature Limits (oC): -60 to 280/300. |
| Agilent 123-1034E |
Agilent GC Column, DB-1 30m, 0.32mm,
0.25um, 5in cage " |
| Agilent 123-1035 |
Agilent Column, DB-1, 0.32mm I.D. x 30m
Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 5.00.
Temperature Limits (oC): -60 to 280/300. |
| Agilent 123-1035E |
Agilent GC Column, DB-1 30m, 0.32mm,
3.00um, 5in cage |
| Agilent 123-103B |
Agilent GC Column |
| Agilent 123-103E |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Wound on 127mm cage. Non-polar. Excellent general purpose
column with wide range of applications. Bonded and cross-linked. Solvent
rinsable. 0.32mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: -60 to
325[degree]C. |
| Agilent 123-1052 |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID.
Length: 5000mm. Film: 0.25um. Temperature Range: -60 to 325[degree]C. |
| Agilent 123-1055 |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID.
Length: 5000mm. Film: 5um. Temperature Range: -60 to 280[degree]C. |
| Agilent 123-1056 |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID.
Length: 5000mm. Film: 0.52um. Temperature Range: -60 to 325[degree]C. |
| Agilent 123-105C |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID.
Length: 5000mm. Film: 1.2um. Temperature Range: -60 to 325[degree]C. |
| Agilent 123-105F |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID.
Length: 5000mm. Film: 1.05um. Temperature Range: -60 to 325[degree]C. |
| Agilent 123-1061 |
Agilent DB*-1 GC Column A nonpolar column
for compounds with similar polarities and larger differences in boiling points.
Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods
504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.32mm.
Length 60m. Thickness 0.10um. |
| Agilent 123-1062 |
Agilent DB*-1 GC Column A nonpolar column
for compounds with similar polarities and larger differences in boiling points.
Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods
504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.32mm.
Length 60m. Thickness 0.25um. |
| Agilent 123-1062E |
Agilent GC Column, DB-1701 60m, 0.25mm,
1.00um, 5in cage |
| Agilent 123-1063 |
Agilent DB*-1 GC Column A nonpolar column
for compounds with similar polarities and larger differences in boiling points.
Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods
504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.32mm.
Length 60m. Thickness 1.00um. |
| Agilent 123-1063E |
Agilent GC Column, DB-1 50m, 0.53mm, 5.0um,
5in cage |
| Agilent 123-1064 |
Agilent Column, DB-1, 0.32mm I.D. x 60m
Inner Diameter (mm I.D.): 0.32. Length (meter): 60. Film Thickness (um): 3.00.
Temperature Limits (oC): -60 to 280/300. |
| Agilent 123-1064E |
Agilent DB-1 60m, 0.32mm, 3.00um, 5 inch
cage |
| Agilent 123-1065 |
Agilent DB*-1 GC Column A nonpolar column
for compounds with similar polarities and larger differences in boiling points.
Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods
504, 505, 515, 515.2, and 551. Range: -60 to 280/300[degree]C. ID 0.32mm.
Length 60m. Thickness 5.00um. |
| Agilent 123-1065E |
Agilent GC Column |
| Agilent 123-106B |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID.
Length: 6000mm. Film: 1.5um. Temperature Range: -60 to 300[degree]C. |
| Agilent 123-106BE |
Agilent GC Column, HP-5 60m, 0.32mm, 1.0um,
5in cage |
| Agilent 123-106E |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Wound on 127mm cage. Non-polar. Excellent general purpose
column with wide range of applications. Bonded and cross-linked. Solvent
rinsable. 0.32mm ID. Length: 6000mm. Film: 0.5um. Temperature Range: -60 to
325[degree]C. |
| Agilent 123-106EE |
Agilent GC Column, HP-1, 60m, 0.32mm,
5.0um, 5in cage |
| Agilent 123-106G |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID.
Length: 6000mm. Film: 2um. Temperature Range: -60 to 280[degree]C. |
| Agilent 123-1111 |
Agilent Column, DB-1ht, 0.32mm I.D. x 15m
Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 0.10.
Temperature Limits (oC): -60 to 400, Similar Phases: PE-1ht. |
| Agilent 123-1131 |
Agilent Column, DB-1ht, 0.32mm I.D. x 30m
Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.10.
Temperature Limits (oC): -60 to 400, Similar Phases: PE-1ht. |
| Agilent 123-1131E |
Agilent GC Column, CAM 30m, 0.32mm, 0.50um,
5in cage |
| Agilent 123-1232 |
Agilent DB-XLB MDN-12. Exceptionally low
bleed. Low polarity. Designed to inhibit column bleed at high temperatures.
Excellent inertness for active compounds. Bonded and cross-linked. Solvent
rinsable. 0.32mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: 30 to
340[degree]C. |
| Agilent 123-1236 |
Agilent DB-XLB MDN-12. Exceptionally low
bleed. Low polarity. Designed to inhibit column bleed at high temperatures.
Excellent inertness for active compounds. Bonded and cross-linked. Solvent
rinsable. 0.32mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: 30 to
340[degree]C. |
| Agilent 123-1262 |
Agilent Column, DB-XLB, 0.32mm I.D. x 60m
Inner Diameter (mm I.D.): 0.32. Length (meter): 60. Film Thickness (um): 0.25.
Temperature Limits (oC): 30 to 340/360, Similar Phases: PE-XLB, MDN-12. |
| Agilent 123-1332 |
Agilent Column, DB-1301, 0.32mm I.D. x 305m
Inner Diameter (mm I.D.): 0.32. Length (meter): 305. Film Thickness (um): 0.25.
Temperature Limits (oC): -20 to 280/300, Similar Phases to DB-1301: Rtx-1301,
PE-1301, HP-1301. |
| Agilent 123-1333 |
Agilent DB-1301 Rtx-1301; PE-1301.
(6%-cyanopropyl-phenyl) methylpolysiloxane. Low/midpolarity. Bonded and
cross-linked. Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 1um.
Temperature Range: -20 to 280[degree]C. |
| Agilent 123-1334 |
Agilent DB*-624 GC Column Intermediate
polarity column for the analysis of volatile priority pollutants. Specified in
EPA method 524.2. Phase composition: bonded 6% cyanopropyl-phenyl, 94%
dimethylpolysiloxane. Temperature range: -20 to 260[degree]C. I.D.: 0.32mm.
Length: 30m. Film Thickness: 1.80um. |
| Agilent 123-1334E |
Agilent DB-624 5 inch CAGE, 30M, 0.32 MM,
1.8U. |
| Agilent 123-1363 |
Agilent DB-1301 Rtx-1301; PE-1301.
(6%-cyanopropyl-phenyl) methylpolysiloxane. Low/midpolarity. Bonded and
cross-linked. Solvent rinsable. 0.32mm ID. Length: 6000mm. Film: 1um.
Temperature Range: -20 to 280[degree]C. |
| Agilent 123-1363E |
Agilent GC Column, DB-5 60m, 0.53mm,
5.00um, 5in cage |
| Agilent 123-1364 |
Agilent DB*-624 GC Column Intermediate
polarity column for the analysis of volatile priority pollutants. Specified in
EPA method 524.2. Phase composition: bonded 6% cyanopropyl-phenyl, 94%
dimethylpolysiloxane. Temperature range: -20 to 260[degree]C. I.D.:0.32mm.
Length: 60m. Film Thickness: 1.80um. |
| Agilent 123-1364E |
Agilent DB-624 AT-624. Wound on 127mm cage.
Designed for the analysis of volatile priority pollutants. Excellent inertness
for active compounds. Bonded and cross-linked. Solvent rinsable. 0.32mm ID.
Length: 6000mm. Film: 1.8um. Temperature Range: -20 to 260[degree]C. |
| Agilent 123-1464 |
Agilent DB-502.2 Rtx-502.2; VOCOL. Bonded
and cross-linked. Solvent rinsable. 0.32mm ID. Length: 6000mm. Film: 1.8um.
Temperature Range: 0 to 260[degree]C. |
| Agilent 123-1534 |
Agilent DB*-VRX GC Column Low polarity. For
optimum resolution of volatiles and separation of the following coeluting
compounds while maintaining good peak shape: m- and p-xylene; and
1,1,2,2-tetrachloroethane and o-xylene. Temperature range: -20 to 260[degree]C.
ID: 0.32mm. Length: 30m. Thickness: 1.80um. |
| Agilent 123-1564 |
Agilent DB*-VRX GC Column Low polarity. For
optimum resolution of volatiles and separation of the following coeluting
compounds while maintaining good peak shape: m- and p-xylene; and
1,1,2,2-tetrachloroethane and o-xylene. Temperature range: -20 to 260[degree]C.
ID: 0.32mm. Length: 60m. Thickness: 1.80um. |
| Agilent 123-1564E |
Agilent GC Column, DB-XLB 60m, 0.25mm,
0.25um, 5in cage |
| Agilent 123-1632 |
Agilent Column, DB-TPH, 0.32mm I.D. x 30m
Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.25.
Temperature Limits (oC): -10 to 320, Similar Phases: PE-TPH. |
| Agilent 123-1711 |
Agilent Column, DB-17, 0.32mm I.D. x 15m
Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 0.15.
Temperature Limits (oC): 40 to 280/300, Similar Phases: HP-17, RSL-300, Rtx-50,
PE-17, CC-17, 007-17 (MPS-50), SP-2250, HP-50+, SPB-50, ZB-50. |
| Agilent 123-1712 |
Agilent Column, DB-17, 0.32mm I.D. x 15m
Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 0.25.
Temperature Limits (oC): 40 to 280/300, Similar Phases: HP-17, RSL-300, Rtx-50,
PE-17, CC-17, 007-17 (MPS-50), SP-2250, HP-50+, SPB-50, ZB-50. |
| Agilent 123-1712E |
Agilent GC Column, DB-17 15m, 0.32mm,
0.25um, 5in cage |
| Agilent 123-1713 |
Agilent Column, DB-17, 0.32mm I.D. x 15m
Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 0.50.
Temperature Limits (oC): 40 to 280/300, Similar Phases: HP-17, RSL-300, Rtx-50,
PE-17, CC-17, 007-17 (MPS-50), SP-2250, HP-50+, SPB-50, ZB-50. |
| Agilent 123-1730 |
Agilent DB*-608 GC Column Intermediate
polarity column for analyzing chlorinated pesticides and PCBs. For EPA method
608. Phase composition: cross-linked/surface bonded proprietary phase of
dimethylphenyl-polysiloxane. Temperature range: 40 to 280[degree]C. ID: 0.32mm.
Length: 30m. Film Thickness: 0.50um. |
| Agilent 123-1731 |
Agilent Column, DB-17, 0.32mm I.D. x 30m
Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.15.
Temperature Limits (oC): 40 to 280/300, Similar Phases: HP-17, RSL-300, Rtx-50,
PE-17, CC-17, 007-17 (MPS-50), SP-2250, HP-50+, SPB-50, ZB-50. |
| Agilent 123-1732 |
Agilent DB*-17 GC Column Intermediate
polarity column. Use as a confirmation column for steroids, pesticides,
herbicides, and drugs. Phase composition: bonded 50% diphenyl, 50%
dimethylpolysiloxane. Temperature range: 40 to 280[degree]C. I.D.: 0.32mm.
Length: 30m. Film Thickness: 0.25um. |
| Agilent 123-1732E |
Agilent GC Column |
| Agilent 123-1733 |
Agilent Column, DB-17, 0.32mm I.D. x 30m
Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.50.
Temperature Limits (oC): 40 to 280/300, Similar Phases: HP-17, RSL-300, Rtx-50,
PE-17, CC-17, 007-17 (MPS-50), SP-2250, HP-50+, SPB-50, ZB-50. |
| Agilent 123-1733E |
Agilent GC Column, DB-1 30m, 0.32mm,5.0um,
5in cage |
| Agilent 123-1762 |
Agilent DB-17 HP-50+; Rtx-50.
(50%-phenyl)-methylpolysiloxane. Midpolarity. Excellent for confirmational
analyses. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 6000mm.
Film: 0.25um. Temperature Range: 40 to 280[degree]C. |
| Agilent 123-1811 |
Agilent Column, DB-17ht, 0.32mm I.D. x 15m
Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 0.15.
Temperature Limits (oC): 40 to 340/365, Similar Phases: Rtx-65TG, PE-17ht. |
| Agilent 123-1831 |
Agilent Column, DB-17ht, 0.32mm I.D. x 30m
Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.15.
Temperature Limits (oC): 40 to 340/365, Similar Phases: Rtx-65TG, PE-17ht. |
| Agilent 123-1831E |
Agilent DB-17HT 30m, 0.32mm, 0.15um, 5 inch
cage |
| Agilent 123-1932 |
Agilent Column, DB-35, 0.32mm I.D. x 30m
Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.25.
Temperature Limits (oC): 40 to 300/320, Similar Phases: Rtx-35, SPB-35, AT-35,
Sup-Herb, PE-35. |
| Agilent 123-1933 |
Agilent DB-35 Rtx-35; SPB-35.
(35%-phenyl)-methylpolysiloxane. Midpolarity. Low bleed. Inert to active
solutes. Ideal for confirmational analyses. Bonded and cross-linked. Solvent
rinsable. 0.32mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: 40 to
300[degree]C. |
| Agilent 123-1933E |
Agilent GC Column, DB-17 30m, 0.32mm,
0.50um, 5in cage |
| Agilent 123-2032 |
Agilent Column, DB-200, 0.32mm I.D. x 30m
Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.25.
Temperature Limits (oC): 30 to 300/320, Similar Phases: Rtx-200. |
| Agilent 123-2033 |
Agilent Column, DB-200, 0.32mm I.D. x 30m
Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.50.
Temperature Limits (oC): 30 to 300/320, Similar Phases: Rtx-200. |
| Agilent 123-2232 |
Agilent Column, DB-225, 0.32mm I.D. x 30m
Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.25.
Temperature Limits (oC): 40 to 220/240, Similar Phases: HP-225, SP-2330, CP-Sil
43CB, RSL-500, Rtx-225, BP-225, CB-225, OV-225, PE-225, 007-225. |
| Agilent 123-2232E |
Agilent GC Column, DB-210 30m, 0.32mm,
0.25um, 5in cage |
| Agilent 123-2332 |
Agilent Column, DB-23, 0.32mm I.D. x 30m
Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.25.
Temperature Limits (oC): 40 to 250/260, Similar Phases: SP-2330, Rtx-2330,
007-23, AT-Silar, PE-23. |
| Agilent 123-2332E |
Agilent GC Column, HP50+, 30m, 0.32mm,
0.5um, 5in cage |
| Agilent 123-2362 |
Agilent Column, DB-23, 0.32mm I.D. x 60m
Inner Diameter (mm I.D.): 0.32. Length (meter): 60. Film Thickness (um): 0.25.
Temperature Limits (oC): 40 to 250/260, Similar Phases: SP-2330, Rtx-2330,
007-23, AT-Silar, PE-23. |
| Agilent 123-2932 |
Agilent DB-225ms HP-225. Equivalent to
(50%-cyanopropylphenyl)-dimethylpolysiloxane. Mid/high polarity. For
separations of cis- and trans-fatty acid methyl esters. Bonded and
cross-linked. Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 0.25um.
Temperature Range: 40 to 240[degree]C. |
| Agilent 123-3212 |
Agilent DB-FFAP Stabilwax-DA, HP-FFAP.
Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed
for the analysis of volatile fatty acids and phenols. Bonded and cross-linked.
Solvent rinsable. 0.32mm ID. Length: 1500mm. Film: 0.25um. Temperature Range:
40 to 250[degree]C. |
| Agilent 123-3223 |
Agilent DB-FFAP Stabilwax-DA, HP-FFAP.
Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed
for the analysis of volatile fatty acids and phenols. Bonded and cross-linked.
Solvent rinsable. 0.32mm ID. Length: 2500mm. Film: 0.5um. Temperature Range: 40
to 250[degree]C. |
| Agilent 123-3232 |
Agilent DB*-FFAP GC Column High polarity
column for analysis of volatile fatty acids and phenols. Phase composition:
cross-linked/surface bonded nitroterephthalic acid modified polyethylene glycol
stationary phase. Temperature range: 40 to 250[degree]C. I.D.: 0.32mm. Length:
30m. Film Thickness: 0.25um. |
| Agilent 123-3232E |
Agilent DB-FFAP Stabilwax-DA. Wound on
127mm cage. Nitroterephthalic acid modified polyethylene glycol. High polarity.
Designed for the analysis of volatile fatty acids and phenols. Bonded and
cross-linked. Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 0.25um.
Temperature Range: 40 to 250[degree]C. |
| Agilent 123-3233 |
Agilent DB-FFAP Stabilwax-DA, HP-FFAP.
Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed
for the analysis of volatile fatty acids and phenols. Bonded and cross-linked.
Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: 40
to 250[degree]C. |
| Agilent 123-3233E |
Agilent GC Column, DB-ALC2 30m, 0.32mm,
1.20um, 5in cage |
| Agilent 123-3234 |
Agilent DB-FFAP Stabilwax-DA, HP-FFAP.
Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed
for the analysis of volatile fatty acids and phenols. Bonded and cross-linked.
Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 1um. Temperature Range: 40
to 250[degree]C. |
| Agilent 123-3253 |
Agilent DB-FFAP Stabilwax-DA, HP-FFAP.
Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed
for the analysis of volatile fatty acids and phenols. Bonded and cross-linked.
Solvent rinsable. 0.32mm ID. Length: 5000mm. Film: 0.5um. Temperature Range: 40
to 250[degree]C. |
| Agilent 123-3262 |
Agilent DB-FFAP Stabilwax-DA, HP-FFAP.
Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed
for the analysis of volatile fatty acids and phenols. Bonded and cross-linked.
Solvent rinsable. 0.32mm ID. Length: 6000mm. Film: 0.25um. Temperature Range:
40 to 250[degree]C. |
| Agilent 123-3263 |
Agilent DB-FFAP Stabilwax-DA, HP-FFAP.
Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed
for the analysis of volatile fatty acids and phenols. Bonded and cross-linked.
Solvent rinsable. 0.32mm ID. Length: 6000mm. Film: 0.5um. Temperature Range: 40
to 250[degree]C. |
| Agilent 123-3264 |
Agilent DB-FFAP Stabilwax-DA, HP-FFAP.
Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed
for the analysis of volatile fatty acids and phenols. Bonded and cross-linked.
Solvent rinsable. 0.32mm ID. Length: 6000mm. Film: 1um. Temperature Range: 40
to 250[degree]C. |
| Agilent 123-3812 |
Agilent DB-35ms Rtx-35; SPB-35. Equivalent
to (35%-phenyl)-methylpolysiloxane. Midpolarity. Low bleed, excellent inertness
for active compounds. Ideal for confirmational analyses. Bonded and
cross-linked. Solvent rinsable. 0.32mm ID. Length: 1500mm. Film: 0.25um.
Temperature Range: 50 to 340[degree]C. |
| Agilent 123-3832 |
Agilent Column, DB-35ms, 0.32mm I.D. x 30m
Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.25.
Temperature Limits (oC): 50 to 340/360, Similar Phases: Rtx-35, SPB-35, AT-35,
Sup-Herb, PE-35ms, MDN-35. |
| Agilent 123-3832E |
Agilent GC Column, HP-PLOT U, 30m, 0.32mm,
10um, 5in cage |
| Agilent 123-4712 |
Agilent Column, DB-17ms, 0.32mm I.D. x 15m
Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 0.25.
Temperature Limits (oC): 40 to 320/340, Similar Phases: HP-50+, Rtx-50, PE-17,
007-17, SP-2250, SPB-50, BPX-50, SPB-17. |
| Agilent 123-4732 |
Agilent Column, DB-17ms, 0.32mm I.D. x 30m
Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.25.
Temperature Limits (oC): 40 to 320/340, Similar Phases: HP-50+, Rtx-50, PE-17,
007-17, SP-2250, SPB-50, BPX-50, SPB-17. |
| Agilent 123-500E |
Agilent DB-5 10m, 0.32mm, 0.50 um |
| Agilent 123-5011 |
Agilent Column, DB-5, 0.32mm I.D. x 15m
Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um):
0.10. |
| Agilent 123-5012 |
Agilent DB*-5 GC Column Nonpolar.
Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95%
methylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.32mm. Length 15m.
Thickness 0.25um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680,
1625, 1653, 8081, 8141, 8270, 8280. |
| Agilent 123-5012E |
Agilent DB-5 HP-5; Ultra-2; SP-B-5. Wound
on a 127mm cage. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose
column with wide range of applications. Low bleed. Bonded and cross-linked.
Solvent rinsable. 0.32mm ID. Length: 1500mm. Film: 0.25um. Temperature Range:
-60 to 325[degree]C. |
| Agilent 123-5013 |
Agilent Column, DB-5, 0.32mm I.D. x 15m
Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness
(um)1.00. |
| Agilent 123-5013E |
Agilent GC Column, DB-5 15m, 0.32mm,
1.00um, 5in cage |
| Agilent 123-5022 |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.32mm ID. Length: 2500mm. Film: 0.25um. Temperature Range: -60 to
325[degree]C. |
| Agilent 123-5026 |
Agilent DB*-5 GC Column Nonpolar.
Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95%
methylpolysiloxane. Range -60 to 325/350[Degree]C. I.D. 0.32mm. Length 25m.
Thickness 0.52um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680,
1625, 1653, 8081, 8141, 8270, 8280. |
| Agilent 123-502D |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.32mm ID. Length: 2500mm. Film: 0.17um. Temperature Range: -60 to
325[degree]C. |
| Agilent 123-502F |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.32mm ID. Length: 2500mm. Film: 1.05um. Temperature Range: -60 to
325[degree]C. |
| Agilent 123-5031 |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.32mm ID. Length: 3000mm. Film: 0.1um. Temperature Range: -60 to
325[degree]C. |
| Agilent 123-5032 |
Agilent DB*-5 GC Column Nonpolar.
Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95%
methylpolysiloxane. Range -60 to 325/350[Degree]C. I.D. 0.32mm. Length 30m.
Thickness 0.25um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680,
1625, 1653, 8081, 8141, 8270, 8280. |
| Agilent 123-5032E |
Agilent GC Column |
| Agilent 123-5033 |
Agilent DB*-5 GC Column Nonpolar.
Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95%
methylpolysiloxane. Range -60 to 325/350[Degree]C. I.D. 0.32mm. Length 30m.
Thickness 1um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680,
1625, 1653, 8081, 8141, 8270, 8280. |
| Agilent 123-5033E |
Agilent GC Column, DB-35 30m, 0.32mm,
0.50um, 5in cage |
| Agilent 123-503B |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.32mm ID. Length: 3000mm. Film: 1.5um. Temperature Range: -60 to
325[degree]C. |
| Agilent 123-503E |
Agilent DB-5 HP-5; Ultra-2; SP-B-5. Wound
on 127mm cage. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column
with wide range of applications. Low bleed. Bonded and cross-linked. Solvent
rinsable. 0.32mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: -60 to
325[degree]C. |
| Agilent 123-5052 |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.32mm ID. Length: 5000mm. Film: 0.25um. Temperature Range: -60 to
325[degree]C. |
| Agilent 123-5053 |
Agilent Column, DB-5, 0.32mm I.D. x 50m
Inner Diameter (mm I.D.): 0.32. Length (meter): 50. Film Thickness (um):
1.00. |
| Agilent 123-5056 |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.32mm ID. Length: 5000mm. Film: 0.52um. Temperature Range: -60 to
325[degree]C. |
| Agilent 123-5062 |
Agilent DB*-5 GC Column Nonpolar.
Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95%
methylpolysiloxane. Range -60 to 325/350[Degree]C. I.D. 0.32mm. Length 50m.
Thickness 0.25um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680,
1625, 1653, 8081, 8141, 8270, 8280. |
| Agilent 123-5063 |
Agilent DB*-5 GC Column Nonpolar.
Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95%
methylpolysiloxane. Range -60 to 325/350[Degree]C. I.D. 0.32mm. Length 60m.
Thickness 1um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680,
1625, 1653, 8081, 8141, 8270, 8280. |
| Agilent 123-5511 |
Agilent Column, DB-5ms, 0.32mm I.D. x 15m
Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 0.10.
Temperature Limits (oC): -60 to 325/350, Similar Phases: Rtx-5MS, HP-5MS,
PTE-5, CP Sil 8 CBms, BPX-5, RH-5ms, HP-5 Trace. |
| Agilent 123-5512 |
Agilent Column, DB-5ms, 0.32mm I.D. x 15m
Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 0.25.
Temperature Limits (oC): -60 to 325/350, Similar Phases: Rtx-5MS, HP-5MS,
PTE-5, CP Sil 8 CBms, BPX-5, RH-5ms, HP-5 Trace. |
| Agilent 123-5513 |
Agilent Column, DB-5ms, 0.32mm I.D. x 15m
Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 1.00.
Temperature Limits (oC): -60 to 325/350, Similar Phases: Rtx-5MS, HP-5MS,
PTE-5, CP Sil 8 CBms, BPX-5, RH-5ms, HP-5 Trace. |
| Agilent 123-5513E |
Agilent DB-5MS 15m, 0.32mm, 1.00um, 5 inch
cage |
| Agilent 123-5526 |
Agilent Column, DB-5ms, 0.32mm I.D. x 25m
Inner Diameter (mm I.D.): 0.32. Length (meter): 25. Film Thickness (um): 0.52.
Temperature Limits (oC): -60 to 325/350, Similar Phases: Rtx-5MS, HP-5MS,
PTE-5, CP Sil 8 CBms, BPX-5, RH-5ms, HP-5 Trace. |
| Agilent 123-5531 |
Agilent DB*-5ms GC Column Nonpolar. MS
certified. Improved signal-to-noise ratio for better sensitivity and mass
spectral integrity with basic and acidic analytes. Composition: bonded 5%
phenyl, 95% dimethylpolysiloxane. Temperature range -60 to 325/350[degree]C.
I.D. 0.32mm. Length 30m. Thickness 0.10um. |
| Agilent 123-5532 |
Agilent DB*-5ms GC Column Nonpolar. MS
certified. Improved signal-to-noise ratio for better sensitivity and mass
spectral integrity with basic and acidic analytes. Composition: bonded 5%
phenyl, 95% dimethylpolysiloxane. Temperature range: -60 to 325/350[degree]C.
I.D. 0.32mm. Length 30m. Thickness 0.25um. |
| Agilent 123-5532E |
Agilent DB-5ms Rtx-5ms. Wound on 127mm
cage. Phenyl Arylene polymer equivalent to (5%-phenyl)-methylpolysiloxane.
Non-polar. Low bleed, excellent inertness for active compounds. Bonded and
cross-linked. Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 0.25um.
Temperature Range: -60 to 325[degree]C. |
| Agilent 123-5533 |
Agilent DB*-5ms GC Column Nonpolar. MS
certified. Improved signal-to-noise ratio for better sensitivity and mass
spectral integrity with basic and acidic analytes. Composition: bonded 5%
phenyl, 95% dimethylpolysiloxane. Temperature range -60 to 325/350[degree]C.
I.D. 0.32mm. Length 30m. Thickness 1.00um. |
| Agilent 123-5533G |
Agilent DuraGuard GC Column Phase: DB-5ms.
I.D.: 0.32mm. Length: 30m. Film thickness: 1.00um. Features a built-in length
of deactivated fused silica tubing that eliminates problems with peak shape,
installation hassles, and leaks associated with unions. |
| Agilent 123-5536 |
Agilent DB*-5ms GC Column Nonpolar. MS
certified. Improved signal-to-noise ratio for better sensitivity and mass
spectral integrity with basic and acidic analytes. Composition: bonded 5%
phenyl, 95% dimethylpolysiloxane. Temperature range: -60 to 325/350[degree]C.
I.D. 0.32mm. Length 30m. Thickness 0.50um. |
| Agilent 123-5561 |
Agilent DB-5ms Rtx-5ms. Phenyl Arylene
polymer equivalent to (5%-phenyl)-methylpolysiloxane. Non-polar. Low bleed,
excellent inertness for active compounds. Bonded and cross-linked. Solvent
rinsable. 0.32mm ID. Length: 6000mm. Film: 0.1um. Temperature Range: -60 to
325[degree]C. |
| Agilent 123-5562 |
Agilent DB*-5ms GC Column Nonpolar. MS
certified. Improved signal-to-noise ratio for better sensitivity and mass
spectral integrity with basic and acidic analytes. Composition: bonded 5%
phenyl, 95% dimethylpolysiloxane. Temperature range -60 to 325/350[degree]C.
I.D. 0.32mm. Length 60m. Thickness 0.25um. |
| Agilent 123-5563 |
Agilent Column, DB-5ms, 0.32mm I.D. x 60m
Inner Diameter (mm I.D.): 0.32. Length (meter): 60. Film Thickness (um): 1.00.
Temperature Limits (oC): -60 to 325/350, Similar Phases: Rtx-5MS, HP-5MS,
PTE-5, CP Sil 8 CBms, BPX-5, RH-5ms, HP-5 Trace. |
| Agilent 123-5566 |
Agilent GC Column |
| Agilent 123-5631 |
Agilent DB*-5.625 GC Column Nonpolar,
inert. For analyzing BNAs. Meet EPA semi-volatiles performance criteria for CLP
protocols and EPA methods 625, 1625, and 8270. Bonded 5% phenyl, 95%
methylpolysiloxane. Temperature range: -60 to 325/350[degree]C. I.D. 0.32mm.
Length 30m. Thickness 0.25um. |
| Agilent 123-5632 |
Agilent DB*-5.625 GC Column Nonpolar,
inert. For analyzing BNAs. Meet EPA semi-volatiles performance criteria for CLP
protocols and EPA methods 625, 1625, and 8270. Bonded 5% phenyl, 95%
methylpolysiloxane. Temperature range: -60 to 325/350[degree]C. I.D. 0.32mm.
Length 30m. Thickness 0.50um. |
| Agilent 123-5701 |
Agilent Db-5Ht, 10M, 0.32Mm, 0.10Um |
| Agilent 123-5711 |
Agilent Column, DB-5ht, 0.32mm I.D. x 15m
Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 0.10.
Temperature Limits (oC): -60 to 400, Similar Phases: PE-5ht. |
| Agilent 123-5711E |
Agilent GC Column, DB-FFAP 15m, 0.53mm,
1.00um, 5in cage |
| Agilent 123-5731 |
Agilent Column, DB-5ht, 0.32mm I.D. x 30m
Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.10.
Temperature Limits (oC): -60 to 400, Similar Phases: PE-5ht. |
| Agilent 123-5731E |
Agilent Capillary Columns The Agilent
J&W DB-5ht is a non-polar column specially processed for extended
temperature limit of 400 deg C |
| Agilent 123-6133 |
Agilent Column, DX-1, 0.32mm I.D. x 30m
Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 1.00.
Temperature Limits (oC): 50 to 250/270. |
| Agilent 123-6412 |
Agilent Column, DX-4, 0.32mm I.D. x 15m
Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 0.25.
Temperature Limits (oC): 50 to 250/270. |
| Agilent 123-6432 |
Agilent DX-4 15% dimethylpolysiloxane - 85%
polyethylene glycol. 0.32mm ID. Length: 3000mm. Film: 0.25um. Temperature
Range: 50 to 250[degree]C. |
| Agilent 123-6462 |
Agilent DX-4 15% dimethylpolysiloxane - 85%
polyethylene glycol. 0.32mm ID. Length: 6000mm. Film: 0.25um. Temperature
Range: 50 to 250[degree]C. |
| Agilent 123-7012 |
Agilent DB-WAX HP-20M; SUPELCOWAX 10.
Polyethylene glycol. High polarity. Improves resolution of low boiling point
analyses. Column-to-column reproducibility. Bonded and cross-linked. Solvent
rinsable. 0.32mm ID. Length: 1500mm. Film: 0.25um. Temperature Range: 20 to
250[degree]C. |
| Agilent 123-7013 |
Agilent DB*-Wax GC Column High polarity
column for the analysis of solvents, aromatics, glycols, essential oils,
flavors, fragrances and volatile fatty acids. Phase composition: cross
linked/surface bonded polyethylene glycol. Range 20 to 240/250[degree]C. I.D.
0.32mm. Length 15m. Thickness 0.50um. |
| Agilent 123-7031 |
Agilent DB-WAX HP-20M; SUPELCOWAX 10.
Polyethylene glycol. High polarity. Improves resolution of low boiling point
analyses. Column-to-column reproducibility. Bonded and cross-linked. Solvent
rinsable. 0.32mm ID. Length: 3000mm. Film: 0.15um. Temperature Range: 20 to
250[degree]C. |
| Agilent 123-7032 |
Agilent DB*-Wax GC Column High polarity
column for the analysis of solvents, aromatics, glycols, essential oils,
flavors, fragrances and volatile fatty acids. Phase composition: cross
linked/surface bonded polyethylene glycol. Range 20 to 250/260[degree]C. I.D.
0.32mm. Length 30m. Thickness 0.25um. |
| Agilent 123-7032E |
Agilent GC Column |
| Agilent 123-7033 |
Agilent DB*-Wax GC Column High polarity
column for the analysis of solvents, aromatics, glycols, essential oils,
flavors, fragrances and volatile fatty acids. Phase composition: cross
linked/surface bonded polyethylene glycol. Range 20 to 240/250[degree]C. I.D.
0.32mm. Length 30m. Thickness 0.50um. |
| Agilent 123-7033E |
Agilent DB-WAX HP-20M; SUPELCOWAX 10. Wound
on 127mm cage. Polyethylene glycol. High polarity. Improves resolution of low
boiling point analyses. Column-to-column reproducibility. Bonded and
cross-linked. Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 0.5um.
Temperature Range: 20 to 250[degree]C. |
| Agilent 123-7062 |
Agilent Column, DB-WAX, 0.32mm I.D. x 60m
Inner Diameter (mm I.D.): 0.32. Length (meter): 60. Film Thickness (um): 0.25.
Temperature Limits (oC): 20 to 250/260. |
| Agilent 123-7063 |
Agilent Column, DB-WAX, 0.32mm I.D. x 60m
Inner Diameter (mm I.D.): 0.32. Length (meter): 60. Film Thickness (um): 0.50.
Temperature Limits (oC): 20 to 240/250. |
| Agilent 123-7063E |
Agilent GC Column |
| Agilent 123-7312 |
Agilent Column, DB-WAXetr, 0.32mm I.D. x
15m Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um):
0.25. Temperature Limits (oC): 30 to 260/280, Similar Phases: HP-20M,
SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW,
007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX. |
| Agilent 123-7314 |
Agilent Column, DB-WAXetr, 0.32mm I.D. x
15m Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um):
1.00. Temperature Limits (oC): 30 to 250/260, Similar Phases: HP-20M,
SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW,
007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX. |
| Agilent 123-7332 |
Agilent Column, DB-WAXetr, 0.32mm I.D. x
30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um):
0.25. Temperature Limits (oC): 30 to 260/280, Similar Phases: HP-20M,
SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW,
007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX. |
| Agilent 123-7332E |
Agilent GC Column, DB-5 30m, 0.32mm,
1.00um, 5in cage |
| Agilent 123-7333 |
Agilent Column, DB-WAXetr, 0.32mm I.D. x
30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um):
0.50. Temperature Limits (oC): 30 to 250/260, Similar Phases: HP-20M,
SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW,
007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX. |
| Agilent 123-7334 |
Agilent Column, DB-WAXetr, 0.32mm I.D. x
30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um):
1.00. Temperature Limits (oC): 30 to 250/260, Similar Phases: HP-20M,
SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW,
007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX. |
| Agilent 123-7354 |
Agilent Column, DB-WAXetr, 0.32mm I.D. x
50m Inner Diameter (mm I.D.): 0.32. Length (meter): 50. Film Thickness (um):
1.00. Temperature Limits (oC): 30 to 250/260, Similar Phases: HP-20M,
SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW,
007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX. |
| Agilent 123-7354E |
Agilent GC Column, HP-88 60m, 0.25mm,
0.2um, 5in cage |
| Agilent 123-7362 |
Agilent Column, DB-WAXetr, 0.32mm I.D. x
60m Inner Diameter (mm I.D.): 0.32. Length (meter): 60. Film Thickness (um):
0.25. Temperature Limits (oC): 30 to 260/280, Similar Phases: HP-20M,
SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW,
007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX. |
| Agilent 123-7362E |
Agilent GC Column, DB-1 60m, 0.32mm,
0.25um, 5in cage |
| Agilent 123-7363 |
Agilent Column, DB-WAXetr, 0.32mm I.D. x
60m Inner Diameter (mm I.D.): 0.32. Length (meter): 60. Film Thickness (um):
0.50. Temperature Limits (oC): 30 to 250/260, Similar Phases: HP-20M,
SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW,
007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX. |
| Agilent 123-7363E |
Agilent GC Column, DB-1 60m, 0.32mm,
1.00um, 5in cage |
| Agilent 123-7364 |
Agilent Column, DB-WAXetr, 0.32mm I.D. x
60m Inner Diameter (mm I.D.): 0.32. Length (meter): 60. Film Thickness (um):
1.00. Temperature Limits (oC): 30 to 250/260, Similar Phases: HP-20M,
SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW,
007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX. |
| Agilent 123-7722 |
Agilent DB-1701P SPB-1701P.
(14%-cyanopropyl-phenyl)-methylpolysiloxane. Low/midpolarity. Designed and
processed for the analysis of organochlorine pesticides. Bonded and
cross-linked. Solvent rinsable. 0.32mm ID. Length: 2500mm. Film: 0.25um.
Temperature Range: -20 to 280[degree]C. |
| Agilent 123-7732 |
Agilent DB-1701P SPB-1701P.
(14%-cyanopropyl-phenyl)-methylpolysiloxane. Low/midpolarity. Designed and
processed for the analysis of organochlorine pesticides. Bonded and
cross-linked. Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 0.25um.
Temperature Range: -20 to 280[degree]C. |
| Agilent 123-9134 |
Agilent DB-ALC1 Rtx-BAC1. Provides reliable
blood alcohol analysis. Bonded and cross-linked. 0.32mm ID. Length: 3000mm.
Film: 1.8um. Temperature Range: 20 to 260[degree]C. |
| Agilent 123-9234 |
Agilent DB-ALC2 Rtx-BAC2. Provides reliable
blood alcohol analysis. Bonded and cross-linked. 0.32mm ID. Length: 3000mm.
Film: 1.2um. Temperature Range: 20 to 260[degree]C. |
| Agilent 123-9234E |
Agilent GC Column, DB-WAXETR 30m, 0.32mm,
0.25um, 5in cage |
| Agilent 124-0034 |
Agilent Column, DB-MTBE, 0.45mm I.D. x 30m
Inner Diameter (mm I.D.): 0.45. Length (meter): 30. Film Thickness (um): 2.55.
Temperature Limits (oC): 10 to 250, Similar Phases: None. |
| Agilent 124-1032 |
Agilent DB-1 HP-1, Ultra-1, SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.45mm ID.
Length: 3000mm. Film: 1.27um. Temperature Range: -60 to 300[degree]C. |
| Agilent 124-1034 |
Agilent DB-1 HP-1, Ultra-1, SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.45mm ID.
Length: 3000mm. Film: 2.55um. Temperature Range: -60 to 260[degree]C. |
| Agilent 124-1334 |
Agilent Column, DB-624, 0.45 x 30m Diameter
(mm I.D.): 0.45. Inner Length (meter): 30. Film Thickness (um): 2.55.
Temperature Limits (oC): -20 to 260, Similar Phases: VOCOL, NON-PAKD, AT-624,
Rtx-Volatiles, Rtx-502.2, PE-624, PE-502, 007-624, 007-502, HP-624, CP-624,
ZB-624. |
| Agilent 124-1374 |
Agilent DB-624 AT-624. Designed for the
analysis of volatile priority pollutants. Excellent inertness for active
compounds. Bonded and cross-linked. Solvent rinsable. 0.45mm ID. Length:
7500mm. Film: 2.55um. Temperature Range: -20 to 260[degree]C. |
| Agilent 124-1534 |
Agilent DB*-VRX GC Column Low polarity. For
optimum resolution of volatiles and separation of the following coeluting
compounds while maintaining good peak shape: m- and p-xylene; and
1,1,2,2-tetrachloroethane and o-xylene. Temperature range: -20 to 260[degree]C.
ID: 0.45mm. Length: 30m. Thickness: 2.55um. |
| Agilent 124-1574 |
Agilent DB*-VRX GC Column Low polarity. For
optimum resolution of volatiles and separation of the following coeluting
compounds while maintaining good peak shape: m- and p-xylene; and
1,1,2,2-tetrachloroethane and o-xylene. Temperature range: -20 to 260[degree]C.
ID: 0.45mm. Length: 75m. Thickness: 2.55um. |
| Agilent 124-1730 |
Agilent DB-608 SPB-608, NON-PAKD Pesticide.
Designed for analysis of chlorinated pesticides and PCBs. Excellent inertness
and recoveries without pesticide breakdown. Bonded and cross-linked. Solvent
rinsable. 0.45mm ID. Length: 3000mm. Film: 0.7um. Temperature Range: 40 to
260[degree]C. |
| Agilent 124-3232 |
Agilent DB-FFAP Stabilwax-DA, HP-FFAP.
Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed
for the analysis of volatile fatty acids and phenols. Bonded and cross-linked.
Solvent rinsable. 0.45mm ID. Length: 3000mm. Film: 0.85um. Temperature Range:
40 to 250[degree]C. |
| Agilent 124-5012 |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.45mm ID. Length: 1500mm. Film: 1.27um. Temperature Range: -60 to
300[degree]C. |
| Agilent 124-5032 |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.45mm ID. Length: 3000mm. Film: 1.27um. Temperature Range: -60 to
300[degree]C. |
| Agilent 124-5037 |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.45mm ID. Length: 3000mm. Film: 0.42um. Temperature Range: -60 to
300[degree]C. |
| Agilent 124-7032 |
Agilent DB-WAX HP-20M. Polyethylene glycol.
High polarity. Improves resolution of low boiling point analyses.
Column-to-column reproducibility. Bonded and cross-linked. Solvent rinsable.
0.45mm ID. Length: 3000mm. Film: 0.85um. Temperature Range: 20 to
230[degree]C. |
| Agilent 125-0034 |
Agilent Column, DB-MTBE, 0.53mm I.D. x 30m
Inner Diameter (mm I.D.): 0.53. Length (meter): 30. Film Thickness (um): 3.00.
Temperature Limits (oC): 10 to 250, Similar Phases: None. |
| Agilent 125-0034E |
Agilent DB-MTBE Wound on 127mm cage. Low
polarity stationary phase. Resolves MTBE from 2-methylpentane and
3-methylpentane. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length:
3000mm. Film: 3um. Temperature Range: 35 to 260[degree]C. |
| Agilent 125-0212 |
Agilent DB*-210 GC Column High polarity
column for organophosphorus pesticides, nitroaromatics, herbicides, and
disinfection by-products. Bonded 50% trifluoropropyl, 50% methylpolysiloxane.
Range: 45 to 240[degree]C. ID: 0.53m. Length: 15m. Film Thickness: 1.00um. For
EPA methods 551, 552, 552.1, and 8141. |
| Agilent 125-0232 |
Agilent DB*-210 GC Column High polarity
column for organophosphorus pesticides, nitroaromatics, herbicides, and
disinfection by-products. Bonded 50% trifluoropropyl, 50% methylpolysiloxane.
Range: 45 to 240[degree]C. ID: 0.53mm. Length: 30m. Film Thickness: 1.00um. For
EPA methods 551, 552, 552.1 and 8141. |
| Agilent 125-0232E |
Agilent GC Column, HP-5MS, 30m, 0.32mm,
0.25um, 5in cage |
| Agilent 125-0712 |
Agilent Column, DB-1701, 0.53mm I.D. x 15m
Inner Diameter (mm I.D.): 0.53. Length (meter): 15. Film Thickness (um): 1.00.
Temperature Limits (oC): -20 to 260/280, Similar Phases to DB-1701: SPB-1701,
CP-Sil 19CB, Rtx-1701, BP-10, CB-1701, OV-1701, PE-1701, 007-1701, ZB-1701,
RH-1701. |
| Agilent 125-0712E |
Agilent GC Column, HP-1MS 15m, 0.25mm,
0.25um, 5in cage |
| Agilent 125-0731 |
Agilent DB-1701 SPB-1701; CP-Sil 19 CB.
(14%-Cyanopropyl-phenyl)-methylpolysiloxane. Low to mid polarity. Solvent
rinsable. Bonded and cross-linked. 0.53mm ID. Length: 3000mm. Film: 0.25um.
Temperature Range: -20 to 260[degree]C. |
| Agilent 125-0732 |
Agilent DB*-1701 GC Column Low-to-mid
polarity column with a dipole moment. Phase composition: bonded 14%
cyanopropylphenyl, 86% dimethylpolysiloxane. Temperature range: -20 to
280/300[degree]C. I.D.: 0.53mm. Length: 30m. Film Thickness: 1.00um. For EPA
methods 507, 508, 515, 515.2, 552, 552.1, and 8081. |
| Agilent 125-0732E |
Agilent DB-1701 SPB-1701; CP-Sil 19 CB.
Wound on 127mm cage. (14%-Cyanopropyl-phenyl)-methylpolysiloxane. Low to mid
polarity. Sovent rinsable. Bonded and cross-linked. 0.53mm ID. Length: 3000mm.
Film: 1um. Temperature Range: -20 to 260[degree]C. |
| Agilent 125-0732G |
Agilent DuraGuard GC Column Phase: DB-1701.
I.D.: 0.53mm. Length: 30m. Film thickness: 1.00um. Features a built-in length
of deactivated fused silica tubing that eliminates problems with peak shape,
installation hassles, and leaks associated with unions. |
| Agilent 125-0733 |
Agilent DB-1701 SPB-1701; CP-Sil 19 CB.
(14%-Cyanopropyl-phenyl)-methylpolysiloxane. Low to mid polarity. Solvent
rinsable. Bonded and cross-linked. 0.53mm ID. Length: 3000mm. Film: 1.5um.
Temperature Range: -20 to 260[degree]C. |
| Agilent 125-0737 |
Agilent DB*-1701 GC Column Low-to-mid
polarity column with a dipole moment. Phase composition: bonded 14%
cyanopropylphenyl, 86% dimethylpolysiloxane. Temperature range: -20 to
280/300[degree]C. I.D.: 0.53mm. Length: 30m. Film Thickness: 0.50um. For EPA
methods 507, 508, 515, 515.2, 552, 552.1, and 8081. |
| Agilent 125-0762 |
Agilent GC Column |
| Agilent 125-0762E |
Agilent GC Column, DB-WAX 60m, 0.53mm,
1.00um, 5in cage |
| Agilent 125-1002 |
Agilent DB-1 7.5M x 0.53 mm, 1.5 um
film. |
| Agilent 125-1002E |
Agilent DB-1 7.5M x 0.53 mm, 1.5 um film, 5
inch. |
| Agilent 125-1005 |
Agilent DB-1 HP-1, Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID.
Length: 500mm. Film: 5um. Temperature Range: -60 to 260[degree]C. |
| Agilent 125-100B |
Agilent DB-1 HP-1, Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID.
Length: 500mm. Film: 2.65um. Temperature Range: -60 to 260[degree]C. |
| Agilent 125-1011 |
Agilent DB*-1 GC Column A nonpolar column
for compounds with similar polarities and larger differences in boiling points.
Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods
504, 505, 515, 515.2, and 551. Range: -60 to 340/360[degree]C. ID 0.53mm.
Length 15m. Thickness 0.15um. |
| Agilent 125-1011E |
Agilent GC Column |
| Agilent 125-1012 |
Agilent DB*-1 GC Column A nonpolar column
for compounds with similar polarities and larger differences in boiling points.
Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods
504, 505, 515, 515.2, and 551. Range: -60 to 300/320[degree]C. ID 0.53mm.
Length 15m. Thickness 1.50um. |
| Agilent 125-1012E |
Agilent GC Column |
| Agilent 125-1014 |
Agilent Column, DB-1, 0.53mm I.D. x 15m
Inner Diameter (mm I.D.): 0.53. Length (meter): 15. Film Thickness (um): 3.00.
Temperature Limits (oC): -60 to 260/280. |
| Agilent 125-1015 |
Agilent DB*-1 GC Column A nonpolar column
for compounds with similar polarities and larger differences in boiling points.
Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods
504, 505, 515, 515.2, and 551. Range: -60 to 260/280[degree]C. ID 0.53mm.
Length 15m. Thickness 5.00um. |
| Agilent 125-1015E |
Agilent GC Column, HP-1, 15m, 0.53mm,
1.5um, 5in cage |
| Agilent 125-1017 |
Agilent DB-1 HP-1; Ultra-1, SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID.
Length: 1500mm. Film: 0.5um. Temperature Range: -60 to 300[degree]C. |
| Agilent 125-101J |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID.
Length: 1500mm. Film: 1um. Temperature Range: -60 to 300[degree]C. |
| Agilent 125-101K |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID.
Length: 1500mm. Film: 0.25um. Temperature Range: -60 to 320[degree]C. |
| Agilent 125-1025 |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID.
Length: 2500mm. Film: 5um. Temperature Range: -60 to 260[degree]C. |
| Agilent 125-102J |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID.
Length: 2500mm. Film: 1um. Temperature Range: -60 to 300[degree]C. |
| Agilent 125-1032 |
Agilent DB*-1 GC Column A nonpolar column
for compounds with similar polarities and larger differences in boiling points.
Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods
504, 505, 515, 515.2, and 551. Range -60 to 300/320[degree]C. ID 0.53mm. Length
30m. Film Thickness 1.50um. |
| Agilent 125-1032E |
Agilent GC Column, HP-50+ 30m, 0.53mm,
0.5um, 5in cage |
| Agilent 125-1034 |
Agilent DB*-1 GC Column A nonpolar column
for compounds with similar polarities and larger differences in boiling points.
Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods
504, 505, 515, 515.2, and 551. Range: -60 to 260/280[degree]C. ID 0.53mm.
Length 30m. Thickness 3.00um. |
| Agilent 125-1034E |
Agilent GC Column |
| Agilent 125-1035 |
Agilent DB*-1 GC Column A nonpolar column
for compounds with similar polarities and larger differences in boiling points.
Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods
504, 505, 515, 515.2, and 551. Range: -60 to 260/280[degree]C. ID 0.53mm.
Length 30m. Thickness 5.00um. |
| Agilent 125-1035E |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Wound on 127mm cage. Non-polar. Excellent general purpose
column with wide range of applications. Bonded and cross-linked. Solvent
rinsable. 0.53mm ID. Length: 3000mm. Film: 5um. Temperature Range: -60 to
260[degree]C. |
| Agilent 125-1037 |
Agilent DB*-1 GC Column A nonpolar column
for compounds with similar polarities and larger differences in boiling points.
Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods
504, 505, 515, 515.2, and 551. Range -60 to 300/320[degree]C. ID 0.53mm. Length
30m. Thickness 0.50um. |
| Agilent 125-1039 |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID.
Length: 3000mm. Film: 0.1um. Temperature Range: -60 to 340[degree]C. |
| Agilent 125-103B |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID.
Length: 3000mm. Film: 2.65um. Temperature Range: -60 to 260[degree]C. |
| Agilent 125-103J |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID.
Length: 3000mm. Film: 1um. Temperature Range: -60 to 300[degree]C. |
| Agilent 125-103JE |
Agilent GC Column, HP-1 30m, 0.53mm,
0.88um, 5in cage |
| Agilent 125-103K |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID.
Length: 3000mm. Film: 0.25um. Temperature Range: -60 to 320[degree]C. |
| Agilent 125-103KE |
Agilent DB-1 30m, 0.53mm, 0.25um, 5 inch
cage |
| Agilent 125-1055 |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID.
Length: 5000mm. Film: 5um. Temperature Range: -60 to 260[degree]C. |
| Agilent 125-1055E |
Agilent GC Column, DB-23 60m, 0.25mm,
0.15um, 5in cage |
| Agilent 125-1062 |
Agilent Column, DB-1, 0.53mm I.D. x 60m
Inner Diameter (mm I.D.): 0.53. Length (meter): 60. Film Thickness (um): 1.50.
Temperature Limits (oC): -60 to 300/320. |
| Agilent 125-1062E |
Agilent GC Column, DB-1 60m, 0.32mm, 1.5um,
5in cage |
| Agilent 125-1064 |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID.
Length: 6000mm. Film: 3um. Temperature Range: -60 to 260[degree]C. |
| Agilent 125-1065 |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID.
Length: 6000mm. Film: 5um. Temperature Range: -60 to 260[degree]C. |
| Agilent 125-1065E |
Agilent GC Column, DB-1 60m, 0.32mm, 0.5um,
5in cage |
| Agilent 125-106J |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID.
Length: 6000mm. Film: 1um. Temperature Range: -60 to 300[degree]C. |
| Agilent 125-106JE |
Agilent DB-1 60m, 0.53mm, 1.00um, 5 inch
cage |
| Agilent 125-10B5 |
Agilent GC Column |
| Agilent 125-10H5 |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID.
Length: 1000mm. Film: 5um. Temperature Range: -60 to 260[degree]C. |
| Agilent 125-10H5E |
Agilent GC Column, DB-1 10m, 0.53mm,
5.00um, 5in cage |
| Agilent 125-10HB |
Agilent DB-1 HP-1; Ultra-1; SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID.
Length: 1000mm. Film: 2.65um. Temperature Range: -60 to 260[degree]C. |
| Agilent 125-10HBE |
Agilent GC Column, DB-1 10m, 0.53mm,
2.65um, 5in cage |
| Agilent 125-1131 |
Agilent DB-1HT 30m, 0.53mm, 0.17 um |
| Agilent 125-1212 |
Agilent Column, DB-XLB, 0.53mm I.D. x 15m
Inner Diameter (mm I.D.): 0.53. Length (meter): 15. Film Thickness (um): 1.50.
Temperature Limits (oC): 30 to 320/340, Similar Phases: PE-XLB, MDN-12. |
| Agilent 125-1232 |
Agilent Column, DB-XLB, 0.53mm I.D. x 30m
Inner Diameter (mm I.D.): 0.53. Length (meter): 30. Film Thickness (um): 1.50.
Temperature Limits (oC): 30 to 320/340, Similar Phases: PE-XLB, MDN-12. |
| Agilent 125-1312 |
Agilent Column, DB-1301, 0.53mm I.D. x 15m
Inner Diameter (mm I.D.): 0.53. Length (meter): 15. Film Thickness (um): 1.00.
Temperature Limits (oC): -20 to 260/280, Similar Phases to DB-1301: Rtx-1301,
PE-1301, HP-1301. |
| Agilent 125-1314 |
Agilent DB-624 15m, 0.53mm, 3.00 um |
| Agilent 125-1332 |
Agilent Column, DB-1301, 0.53mm I.D. x 30m
Inner Diameter (mm I.D.): 0.53. Length (meter): 30. Film Thickness (um): 1.00.
Temperature Limits (oC): -20 to 260/280, Similar Phases to DB-1301: Rtx-1301,
PE-1301, HP-1301. |
| Agilent 125-1333 |
Agilent DB-1301 Rtx-1301, PE-1301.
(6%-cyanopropyl-phenyl) methylpolysiloxane. Low/midpolarity. Bonded and
cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 1.5um.
Temperature Range: -20 to 260[degree]C. |
| Agilent 125-1334 |
Agilent DB*-624 GC Column Intermediate
polarity column for the analysis of volatile priority pollutants. Specified in
EPA method 524.2. Phase composition: bonded 6% cyanopropyl-phenyl, 94%
dimethylpolysiloxane. Temperature range: -20 to 260[degree]C. I.D.:0.53mm.
Length: 30m. Film Thickness: 3.00um. |
| Agilent 125-1334E |
Agilent DB-624 AT-624. Wound on 127mm cage.
Designed for the analysis of volatile priority pollutants. Excellent inertness
for active compounds. Bonded and cross-linked. Solvent rinsable. 0.53mm ID.
Length: 3000mm. Film: 3um. Temperature Range: -20 to 260[degree]C. |
| Agilent 125-1334G5 |
Agilent GC Column |
| Agilent 125-1364 |
Agilent DB-624 AT-624. Designed for the
analysis of volatile priority pollutants. Excellent inertness for active
compounds. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length:
6000mm. Film: 3um. Temperature Range: -20 to 260[degree]C. |
| Agilent 125-1364E |
Agilent GC Column, DB-1701 60m, 0.32mm,
0.25um, 5in cage |
| Agilent 125-1374 |
Agilent DB*-624 GC Column Intermediate
polarity column for the analysis of volatile priority pollutants. Specified in
EPA method 524.2. Phase composition: bonded 6% cyanopropyl-phenyl, 94%
dimethylpolysiloxane. Temperature range: -20 to 260[degree]C. I.D.:0.53mm.
Length: 75m. Film Thickness: 3.00um. |
| Agilent 125-1374E |
Agilent GC Column |
| Agilent 125-14A4 |
Agilent Column, DB-502.2, 0.53mm I.D. x
105m Inner Diameter (mm I.D.): 0.53. Length (meter): 105. Film Thickness (um):
3.00. Temperature Limits (oC): 0 to 260/280, Similar Phases: Rtx-502.2, VOCOL,
HP-VOC. |
| Agilent 125-1704 |
Agilent Column, DB-17, 0.53mm I.D. x 5m
Inner Diameter (mm I.D.): 0.53. Length (meter): 5. Film Thickness (um): 2.00.
Temperature Limits (oC): 40 to 260/280, Similar Phases: HP-17, RSL-300, Rtx-50,
PE-17, CC-17, 007-17 (MPS-50), SP-2250, HP-50+, SPB-50, ZB-50. |
| Agilent 125-1710 |
Agilent DB*-608 GC Column Intermediate
polarity column for analyzing chlorinated pesticides and PCBs. For EPA method
608. Phase composition: cross-linked/surface bonded proprietary phase of
dimethylphenyl-polysiloxane. Temperature range: 40 to 260[degree]C. ID: 0.53mm.
Length: 15m. Film Thickness: 0.83um. |
| Agilent 125-1711 |
Agilent DB-17 HP-50+; Rtx-50.
(50%-phenyl)-methylpolysiloxane. Midpolarity. Excellent for confirmational
analyses. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 1500mm.
Film: 0.25um. Temperature Range: 40 to 260[degree]C. |
| Agilent 125-1712 |
Agilent DB*-17 GC Column Intermediate
polarity column. Use as a confirmation column for steroids, pesticides,
herbicides, and drugs. Phase composition: bonded 50% diphenyl, 50%
dimethylpolysiloxane. Temperature range: 40 to 260[degree]C. I.D.: 0.53mm.
Length: 15m. Film Thickness: 1.00um. |
| Agilent 125-1713 |
Agilent DB-17 HP-50+; Rtx-50.
(50%-phenyl)-methylpolysiloxane. Midpolarity. Excellent for confirmational
analyses. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 1500mm.
Film: 1.5um. Temperature Range: 40 to 260[degree]C. |
| Agilent 125-1717 |
Agilent DB-17 HP-50+; Rtx-50.
(50%-phenyl)-methylpolysiloxane. Midpolarity. Excellent for confirmational
analyses. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 1500mm.
Film: 0.5um. Temperature Range: 40 to 260[degree]C. |
| Agilent 125-1730 |
Agilent DB*-608 GC Column Intermediate
polarity column for analyzing chlorinated pesticides and PCBs. For EPA method
608. Phase composition: cross-linked/surface bonded proprietary phase of
dimethylphenyl-polysiloxane. Temperature range: 40 to 260[degree]C. ID: 0.53mm.
Length: 30m. Film Thickness: 0.83um. |
| Agilent 125-1731 |
Agilent DB-17 HP-50+; Rtx-50.
(50%-phenyl)-methylpolysiloxane. Midpolarity. Excellent for confirmational
analyses. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm.
Film: 0.25um. Temperature Range: 40 to 260[degree]C. |
| Agilent 125-1731E |
Agilent GC Column, DB-1 30m, 0.53mm,
1.50um, 5in cage |
| Agilent 125-1732 |
Agilent DB*-17 GC Column Intermediate
polarity column. Use as a confirmation column for steroids, pesticides,
herbicides, and drugs. Phase composition: bonded 50% diphenyl, 50%
dimethylpolysiloxane. Temperature range: 40 to 260[degree]C. I.D.: 0.53mm.
Length: 30m. Film Thickness: 1.00um. |
| Agilent 125-1732E |
Agilent DB-17 30m, 0.53mm, 1.00um, 5 inch
cage |
| Agilent 125-1733 |
Agilent DB-17 HP-50+; Rtx-50.
(50%-phenyl)-methylpolysiloxane. Midpolarity. Excellent for confirmational
analyses. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm.
Film: 1.5um. Temperature Range: 40 to 260[degree]C. |
| Agilent 125-1737 |
Agilent DB-17 HP-50+; Rtx-50.
(50%-phenyl)-methylpolysiloxane. Midpolarity. Excellent for confirmational
analyses. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm.
Film: 0.5um. Temperature Range: 40 to 260[degree]C. |
| Agilent 125-1762 |
Agilent DB-17 HP-50+; Rtx-50.
(50%-phenyl)-methylpolysiloxane. Midpolarity. Excellent for confirmational
analyses. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 6000mm.
Film: 1um. Temperature Range: 40 to 260[degree]C. |
| Agilent 125-1912 |
Agilent DB-35 Rtx-35; SPB-35.
(35%-phenyl)-methylpolysiloxane. Midpolarity. Low bleed. Inert to active
solutes. Ideal for confirmational analyses. Bonded and cross-linked. Solvent
rinsable. 0.53mm ID. Length: 1500mm. Film: 1um. Temperature Range: 40 to
280[degree]C. |
| Agilent 125-1932 |
Agilent Column, DB-35, 0.53mm I.D. x 30m
Inner Diameter (mm I.D.): 0.53. Length (meter): 30. Film Thickness (um): 1.00.
Temperature Limits (oC): 40 to 260/280, Similar Phases: Rtx-35, SPB-35, AT-35,
Sup-Herb, PE-35. |
| Agilent 125-1937 |
Agilent Column, DB-35, 0.53mm I.D. x 30m
Inner Diameter (mm I.D.): 0.53. Length (meter): 30. Film Thickness (um): 0.50.
Temperature Limits (oC): 40 to 280/300, Similar Phases: Rtx-35, SPB-35, AT-35,
Sup-Herb, PE-35. |
| Agilent 125-2032 |
Agilent Column, DB-200, 0.53mm I.D. x 30m
Inner Diameter (mm I.D.): 0.53. Length (meter): 30. Film Thickness (um): 1.00.
Temperature Limits (oC): 30 to 280/300, Similar Phases: Rtx-200. |
| Agilent 125-2032E |
Agilent GC Column, HP-1MS, 30m, 0.32mm,
0.25um, 5in cage |
| Agilent 125-2212 |
Agilent Column, DB-225, 0.53mm I.D. x 15m
Inner Diameter (mm I.D.): 0.53. Length (meter): 15. Film Thickness (um): 1.00.
Temperature Limits (oC): 40 to 200/220, Similar Phases: HP-225, SP-2330, CP-Sil
43CB, RSL-500, Rtx-225, BP-225, CB-225, OV-225, PE-225, 007-225. |
| Agilent 125-2232 |
Agilent Column, DB-225, 0.53mm I.D. x 30m
Inner Diameter (mm I.D.): 0.53. Length (meter): 30. Film Thickness (um): 1.00.
Temperature Limits (oC): 40 to 200/220, Similar Phases: HP-225, SP-2330, CP-Sil
43CB, RSL-500, Rtx-225, BP-225, CB-225, OV-225, PE-225, 007-225. |
| Agilent 125-2232E |
Agilent GC Column, DB-35MS 30m, 0.32mm,
0.25um, 5in cage |
| Agilent 125-2237 |
Agilent DB-225 SP-233; CP-Sil 43 CB.
(50%-cyanopropylphenyl)-dimethylpolysiloxane. Mid/high polarity. Excellent for
separations of cis- and trans-fatty acid methyl esters. Bonded and
cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 0.5um.
Temperature Range: 40 to 200[degree]C. |
| Agilent 125-2312 |
Agilent Column, DB-23, 0.53mm I.D. x 15m
Inner Diameter (mm I.D.): 0.53. Length (meter): 15. Film Thickness (um): 0.50.
Temperature Limits (oC): 40 to 230/240, Similar Phases: SP-2330, Rtx-2330,
007-23, AT-Silar, PE-23. |
| Agilent 125-2814 |
Agilent Column, DB-2887, 0.53mm I.D. x 10m
Inner Diameter (mm I.D.): 0.53. Length (meter): 10. Film Thickness (um): 3.00.
Temperature Limits (oC): -60 to 350, Similar Phases: HP-1, Petrocol EX2887,
MXT-2887, MXT-1, HT Sim Dist CB, PE-Sim Dist. |
| Agilent 125-3212 |
Agilent DB*-FFAP GC Column High polarity
column for analysis of volatile fatty acids and phenols. Phase composition:
cross-linked/surface bonded nitroterephthalic acid modified polyethylene glycol
stationary phase. Temperature range: 40 to 250[degree]C. I.D.: 0.53mm. Length:
15m. Film Thickness: 1.00um. |
| Agilent 125-3212E |
Agilent GC Column, DB-5HT 15m, 0.25mm,
0.10um, 5in cage |
| Agilent 125-3217 |
Agilent DB-FFAP Stabilwax-DA, HP-FFAP.
Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed
for the analysis of volatile fatty acids and phenols. Bonded and cross-linked.
Solvent rinsable. 0.53mm ID. Length: 1500mm. Film: 0.5um. Temperature Range: 40
to 250[degree]C. |
| Agilent 125-3231 |
Agilent DB-FFAP Stabilwax-DA, HP-FFAP.
Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed
for the analysis of volatile fatty acids and phenols. Bonded and cross-linked.
Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 0.25um. Temperature Range:
40 to 250[degree]C. |
| Agilent 125-3232 |
Agilent DB*-FFAP GC Column High polarity
column for analysis of volatile fatty acids and phenols. Phase composition:
cross-linked/surface bonded nitroterephthalic acid modified polyethylene glycol
stationary phase. Temperature range: 40 to 250[degree]C. I.D.: 0.53mm. Length:
30m. Film Thickness: 1.00um. |
| Agilent 125-3232E |
Agilent GC Column, DB-WAXETR 30m, 0.53mm,
2.00um, 5in cage |
| Agilent 125-3233 |
Agilent DB-FFAP Stabilwax-DA, HP-FFAP.
Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed
for the analysis of volatile fatty acids and phenols. Bonded and cross-linked.
Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 1.5um. Temperature Range: 40
to 250[degree]C. |
| Agilent 125-3237 |
Agilent DB-FFAP Stabilwax-DA, HP-FFAP.
Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed
for the analysis of volatile fatty acids and phenols. Bonded and cross-linked.
Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: 40
to 250[degree]C. |
| Agilent 125-3262 |
Agilent DB-FFAP Stabilwax-DA, HP-FFAP.
Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed
for the analysis of volatile fatty acids and phenols. Bonded and cross-linked.
Solvent rinsable. 0.53mm ID. Length: 6000mm. Film: 1um. Temperature Range: 40
to 250[degree]C. |
| Agilent 125-32H2 |
Agilent DB-FFAP Stabilwax-DA, HP-FFAP.
Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed
for the analysis of volatile fatty acids and phenols. Bonded and cross-linked.
Solvent rinsable. 0.53mm ID. Length: 1000mm. Film: 1um. Temperature Range: 40
to 250[degree]C. |
| Agilent 125-3832 |
Agilent DB-35ms Rtx-35; SPB-35. Equivalent
to (35%-phenyl)-methylpolysiloxane. Midpolarity. Low bleed, excellent inertness
for active compounds. Ideal for confirmational analyses. Bonded and
cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 1um.
Temperature Range: 50 to 320[degree]C. |
| Agilent 125-3837 |
Agilent DB-35ms Rtx-35; SPB-35. Equivalent
to (35%-phenyl)-methylpolysiloxane. Midpolarity. Low bleed, excellent inertness
for active compounds. Ideal for confirmational analyses. Bonded and
cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 0.5um.
Temperature Range: 50 to 320[degree]C. |
| Agilent 125-5012 |
Agilent DB*-5 GC Column Nonpolar.
Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95%
methylpolysiloxane. Range û60 to 300/320[Degree]C. I.D. 0.53mm. Length
15m. Thickness 1.5um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1,
680, 1625, 1653, 8081, 8141, 8270, 8280. |
| Agilent 125-5012E |
Agilent GC Column, DB-1 15m, 0.53mm,
5.00um, 5in cage |
| Agilent 125-501J |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.53mm ID. Length: 1500mm. Film: 1um. Temperature Range: -60 to
300[degree]C. |
| Agilent 125-501K |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.53mm ID. Length: 1500mm. Film: 0.25um. Temperature Range: -60 to
300[degree]C. |
| Agilent 125-5025 |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.53mm ID. Length: 2500mm. Film: 5um. Temperature Range: -60 to
260[degree]C. |
| Agilent 125-5032 |
Agilent DB*-5 GC Column Nonpolar.
Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95%
methylpolysiloxane. Range û60 to 300/320[Degree]C. I.D.0.53mm. Length
30m. Thickness 1.5um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1,
680, 1625, 1653, 8081, 8141, 8270, 8280. |
| Agilent 125-5034 |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.53mm ID. Length: 3000mm. Film: 3um. Temperature Range: -60 to
260[degree]C. |
| Agilent 125-5034E |
Agilent DB-5 30m, 0.53mm, 3.00um, 5 inch
cage |
| Agilent 125-5035 |
Agilent DB*-5 GC Column Nonpolar.
Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95%
methylpolysiloxane. Range û60 to 300/320[Degree]C. I.D. 0.53mm. Length
30m. Thickness 5um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1,
680, 1625, 1653, 8081, 8141, 8270, 8280. |
| Agilent 125-5035E |
Agilent GC Column, DB-1 30m, 0.53mm,
1.00um, 5in cage |
| Agilent 125-5037 |
Agilent DB*-5 GC Column Nonpolar.
Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95%
methylpolysiloxane. Range û60 to 300/320[Degree]C. I.D. 0.53um. Length
30m. Thickness 0.5um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1,
680, 1625, 1653, 8081, 8141, 8270, 8280. |
| Agilent 125-5037E |
Agilent GC Column, DB-17 30m, 0.53mm,
0.25um, 5in cage |
| Agilent 125-503B |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.53mm ID. Length: 3000mm. Film: 2.65um. Temperature Range: -60 to
260[degree]C. |
| Agilent 125-503D |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.53mm ID. Length: 3000mm. Film: 0.88um. Temperature Range: -60 to
300[degree]C. |
| Agilent 125-503J |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.53mm ID. Length: 3000mm. Film: 1um. Temperature Range: -60 to
300[degree]C. |
| Agilent 125-503K |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.53mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: -60 to
300[degree]C. |
| Agilent 125-5062 |
Agilent Column, DB-5, 0.53mm I.D. x 60m
Inner Diameter (mm I.D.): 0.53. Length (meter): 60. Film Thickness (um):
1.50. |
| Agilent 125-5065 |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.53mm ID. Length: 6000mm. Film: 5um. Temperature Range: -60 to
260[degree]C. |
| Agilent 125-5065E |
Agilent GC Column, DB-5, 60m, 0.32mm,
1.0um, 5in cage |
| Agilent 125-50HB |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.53mm ID. Length: 1000mm. Film: 2.65um. Temperature Range: -60 to
300[degree]C. |
| Agilent 125-5512 |
Agilent Column, DB-5ms, 0.53mm I.D. x 15m
Inner Diameter (mm I.D.): 0.53. Length (meter): 15. Film Thickness (um): 1.50.
Temperature Limits (oC): -60 to 300/320, Similar Phases: Rtx-5MS, HP-5MS,
PTE-5, CP Sil 8 CBms, BPX-5, RH-5ms, HP-5 Trace. |
| Agilent 125-5532 |
Agilent DB*-5ms GC Column Nonpolar. MS
certified. Improved signal-to-noise ratio for better sensitivity and mass
spectral integrity with basic and acidic analytes. Composition: bonded 5%
phenyl, 95% dimethylpolysiloxane. Temperature range -60 to 300/350[degree]C.
I.D. 0.53mm. Length 30m. Thickness 1.50um. |
| Agilent 125-5537 |
Agilent DB-5ms Rtx-5ms. Phenyl Arylene
polymer equivalent to (5%-phenyl)-methylpolysiloxane. Non-polar. Low bleed,
excellent inertness for active compounds. Bonded and cross-linked. Solvent
rinsable. 0.53mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: -60 to
300[degree]C. |
| Agilent 125-5537G |
Agilent DuraGuard GC Column Phase: DB-5ms.
I.D.: 0.53mm. Length: 30m. Film thickness: 0.50um. Features a built-in length
of deactivated fused silica tubing that eliminates problems with peak shape,
installation hassles, and leaks associated with unions. |
| Agilent 125-553J |
Agilent DB-5ms Rtx-5ms. Phenyl Arylene
polymer equivalent to (5%-phenyl)-methylpolysiloxane. Non-polar. Low bleed,
excellent inertness for active compounds. Bonded and cross-linked. Solvent
rinsable. 0.53mm ID. Length: 3000mm. Film: 1um. Temperature Range: -60 to
325[degree]C. |
| Agilent 125-6837 |
Agilent DB*-608 GC Column Intermediate
polarity column for analyzing chlorinated pesticides and PCBs. For EPA method
608. Phase composition: cross-linked/surface bonded proprietary phase of
dimethylphenyl-polysiloxane. Temperature range: 40 to 260[degree]C. ID: 0.53mm.
Length: 30m. Film Thickness: 0.50um. |
| Agilent 125-7012 |
Agilent DB*-Wax GC Column High polarity
column for the analysis of solvents, aromatics, glycols, essential oils,
flavors, fragrances and volatile fatty acids. Phase composition: cross
linked/surface bonded polyethylene glycol. Range 20 to 230/240[degree]C. I.D.
0.53mm. Length 15m. Thickness 1um. |
| Agilent 125-7012E |
Agilent GC Column, DB-5 15m, 0.53mm,
1.50um, 5in cage |
| Agilent 125-7017 |
Agilent Column, DB-WAX, 0.53mm I.D. x 15m
Inner Diameter (mm I.D.): 0.53. Length (meter): 15. Film Thickness (um): 0.50.
Temperature Limits (oC): 20 to 230/240. |
| Agilent 125-7031 |
Agilent DB-WAX HP-20M; SUPELCOWAX 10.
Polyethylene glycol. High polarity. Improves resolution of low boiling point
analyses. Column-to-column reproducibility. Bonded and cross-linked. Solvent
rinsable. 0.53mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: 20 to
230[degree]C. |
| Agilent 125-7032 |
Agilent DB*-Wax GC Column High polarity
column for the analysis of solvents, aromatics, glycols, essential oils,
flavors, fragrances and volatile fatty acids. Phase composition: cross
linked/surface bonded polyethylene glycol. Range 20 to 230/240[degree]C. I.D.
0.53mm. Length 30m. Thickness 1um. |
| Agilent 125-7032E |
Agilent DB-WAX HP-20M; SUPELCOWAX 10. Wound
on 127mm cage. Polyethylene glycol. High polarity. Improves resolution of low
boiling point analyses. Column-to-column reproducibility. Bonded and
cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 1um.
Temperature Range: 20 to 230[degree]C. |
| Agilent 125-7037 |
Agilent DB*-Wax GC Column High polarity
column for the analysis of solvents, aromatics, glycols, essential oils,
flavors, fragrances and volatile fatty acids. Phase composition: cross
linked/surface bonded polyethylene glycol. Range 20 to 230/240[degree]C. I.D.
0.53mm. Length 30m. Thickness 0.50um. |
| Agilent 125-7062 |
Agilent Column, DB-WAX, 0.53mm I.D. x 60m
Inner Diameter (mm I.D.): 0.53. Length (meter): 60. Film Thickness (um): 1.00.
Temperature Limits (oC): 20 to 230/240. |
| Agilent 125-7062E |
Agilent GC Column, DB-WAXETR 60m, 0.32mm,
0.25um, 5in cage |
| Agilent 125-7312 |
Agilent Column, DB-WAXetr, 0.53mm I.D. x
15m Inner Diameter (mm I.D.): 0.53. Length (meter): 15. Film Thickness (um):
1.00. Temperature Limits (oC): 30 to 240/260, Similar Phases: HP-20M,
SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW,
007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX. |
| Agilent 125-7314 |
Agilent Column, DB-WAXetr, 0.53mm I.D. x
15m Inner Diameter (mm I.D.): 0.53. Length (meter): 15. Film Thickness (um):
2.00. Temperature Limits (oC): 50 to 230/250, Similar Phases: HP-20M,
SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW,
007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX. |
| Agilent 125-7332 |
Agilent Column, DB-WAXetr, 0.53mm I.D. x
30m Inner Diameter (mm I.D.): 0.53. Length (meter): 30. Film Thickness (um):
1.00. Temperature Limits (oC): 30 to 240/260, Similar Phases: HP-20M,
SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW,
007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX. |
| Agilent 125-7332E |
Agilent GC Column, DB-5 30m, 0.53mm,
5.00um, 5in cage |
| Agilent 125-7333 |
Agilent DB-WAXetr HP-20M; SUPELCOWAX 10.
Polyethylene glycol. Extended temperature range. High polarity. Excellent
column-to-column repeatability. Bonded and cross-linked. Solvent rinsable.
0.53mm ID. Length: 3000mm. Film: 1.5um. Temperature Range: 30 to
230[degree]C. |
| Agilent 125-7334 |
Agilent Column, DB-WAXetr, 0.53mm I.D. x
30m Inner Diameter (mm I.D.): 0.53. Length (meter): 30. Film Thickness (um):
2.00. Temperature Limits (oC): 50 to 230/250, Similar Phases: HP-20M,
SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW,
007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX. |
| Agilent 125-7334E |
Agilent GC Column, DB-5 30m, 0.53mm,
0.50um, 5in cage |
| Agilent 125-7362 |
Agilent Column, DB-WAXetr, 0.53mm I.D. x
60m Inner Diameter (mm I.D.): 0.53. Length (meter): 60. Film Thickness (um):
1.00. Temperature Limits (oC): 30 to 240/260, Similar Phases: HP-20M,
SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW,
007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX. |
| Agilent 125-7732 |
Agilent DB*-1701P Capillary Column A
low/midpolarity column for analyzing organochlorine pesticides. Tested using an
ECD detector to ensure CLP performance criteria for p,p'-DDT breakdown. Phase
composition: bonded 14% cyanpropylphenyl, 86% methylpolysiloxane. Temperature
range: -20 to 260[degree]C. |
| Agilent 125-9134 |
Agilent DB-ALC1 Rtx-BAC1. Provides reliable
blood alcohol analysis. Bonded and cross-linked. 0.53mm ID. Length: 3000mm.
Film: 3um. Temperature Range: 20 to 260[degree]C. |
| Agilent 125-9134E |
Agilent Automatic Static Headspace Systems
DB-ALC1 and DB-ALC2 results are complete in just 2 minutes, reducing run time
by one-third compared to other blood alcohol analysis columns. TodayÆs
automated static headspace systems (SHS) utilize multi-sample equilibration
ovens. |
| Agilent 125-9234 |
Agilent DB-ALC2 Rtx-BAC2. Provides reliable
blood alcohol analysis. Bonded and cross-linked. 0.53mm ID. Length: 3000mm.
Film: 2um. Temperature Range: 20 to 260[degree]C. |
| Agilent 126-1012 |
Agilent Column, DB-1, 0.05mm I.D. x 10m
Inner Diameter (mm I.D.): 0.05. Length (meter): 10. Film Thickness (um): 0.05.
Temperature Limits (oC): -60 to 325/350. |
| Agilent 126-1013 |
Agilent Column, DB-1, 0.05mm I.D. x 10m
Inner Diameter (mm I.D.): 0.05. Length (meter): 10. Film Thickness (um): 0.20.
Temperature Limits (oC): -60 to 325/350. |
| Agilent 126-1713 |
Agilent Column, DB-17, 0.05mm I.D. x 10m
Inner Diameter (mm I.D.): 0.05. Length (meter): 10. Film Thickness (um): 0.10.
Temperature Limits (oC): 40 to 280/300, Similar Phases: HP-17, RSL-300, Rtx-50,
PE-17, CC-17, 007-17 (MPS-50), SP-2250, HP-50+, SPB-50, ZB-50. |
| Agilent 126-7012 |
Agilent Column, DB-WAX, 0.05mm I.D. x 10m
Inner Diameter (mm I.D.): 0.05. Length (meter): 10. Film Thickness (um): 0.05.
Temperature Limits (oC): 20 to 250/260. |
| Agilent 126-7013 |
Agilent Column, DB-WAX, 0.05mm I.D. x 10m
Inner Diameter (mm I.D.): 0.05. Length (meter): 10. Film Thickness (um): 0.10.
Temperature Limits (oC): 20 to 250/260. |
| Agilent 127-0113 |
Agilent DB-1ms HP-1ms. 100%
dimethylpolysiloxane, identical selectivity to DB-1. Non-polar. General purpose
column with low bleed characteristics. Bonded and cross-linked. Solvent
rinsable. 0.1mm ID. Length: 1000mm. Film: 0.4um. Temperature Range: -60 to
340[degree]C. |
| Agilent 127-0113E |
Agilent GC Column, DB-5HT 15m, 0.32mm,
0.10um, 5in cage |
| Agilent 127-0722 |
Agilent DB-1701 SPB-1701, CP-Sil 19 CB.
(14%-Cyanopropyl-phenyl)-methylpolysiloxane. Low to mid polarity. Sovent
rinsable. Bonded and cross-linked. 0.1mm ID. Length: 2000mm. Film: 0.1um.
Temperature Range: -20 to 280[degree]C. |
| Agilent 127-0723 |
Agilent DB-1701 SPB-1701, CP-Sil 19 CB.
(14%-Cyanopropyl-phenyl)-methylpolysiloxane. Low to mid polarity. Sovent
rinsable. Bonded and cross-linked. 0.1mm ID. Length: 2000mm. Film: 0.4um.
Temperature Range: -20 to 280[degree]C. |
| Agilent 127-0723E |
Agilent GC Column, DB-210 30m, 0.25mm,
0.25um, 5in cage |
| Agilent 127-100A |
Agilent DB-1 HP-1, Ultra-1, SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.1mm ID.
Length: 500mm. Film: 0.12um. Temperature Range: -60 to 325[degree]C. |
| Agilent 127-1012E |
Agilent DB-1 HP-1, Ultra-1, SPB-1. Wound on
127mm cage. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose
column with wide range of applications. Bonded and cross-linked. Solvent
rinsable. 0.1mm ID. Length: 1000mm. Film: 0.1um. Temperature Range: -60 to
325[degree]C. |
| Agilent 127-1013 |
Agilent Column, DB-1, 0.10mm I.D. x 10m
Inner Diameter (mm I.D.): 0.10. Length (meter): 10. Film Thickness (um): 0.40.
Temperature Limits (oC): -60 to 325/350. |
| Agilent 127-1013E |
Agilent DB-1 HP-1, Ultra-1, SPB-1. Wound on
127mm cage. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose
column with wide range of applications. Bonded and cross-linked. Solvent
rinsable. 0.1mm ID. Length: 1000mm. Film: 0.4um. Temperature Range: -60 to
325[degree]C. |
| Agilent 127-1022 |
Agilent Column, DB-1, 0.10mm I.D. x 20m
Inner Diameter (mm I.D.): 0.10. Length (meter): 20. Film Thickness (um): 0.10.
Temperature Limits (oC): -60 to 325/350. |
| Agilent 127-1023 |
Agilent DB*-1 GC Column A nonpolar column
for compounds with similar polarities and larger differences in boiling points.
Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods
504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.10mm.
Length 20m. Thickness 0.40um. |
| Agilent 127-1023E |
Agilent GC Column, DB-1301 30m, 0.25mm,
1.00um, 5in cage |
| Agilent 127-1043 |
Agilent DB-1 HP-1, Ultra-1, SPB-1. 100%
dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide
range of applications. Bonded and cross-linked. Solvent rinsable. 0.1mm ID.
Length: 4000mm. Film: 0.4um. Temperature Range: -60 to 325[degree]C. |
| Agilent 127-1046 |
Agilent Column, DB-1, 0.10mm I.D. x 40m
Inner Diameter (mm I.D.): 0.10. Length (meter): 40. Film Thickness (um): 0.20.
Temperature Limits (oC): -60 to 325/350. |
| Agilent 127-1046E |
Agilent DB-1 40m, 0.10mm, 0.20um, 5 inch
cage |
| Agilent 127-1713 |
Agilent DB-17 HP-50+; Rtx-50.
(50%-phenyl)-methylpolysiloxane. Midpolarity. Excellent for confirmational
analyses. Bonded and cross-linked. Solvent rinsable. 0.1mm ID. Length: 1000mm.
Film: 0.2um. Temperature Range: 40 to 260[degree]C. |
| Agilent 127-2222 |
Agilent DB-225 SP-233; CP-Sil 43 CB.
(50%-cyanopropylphenyl)-dimethylpolysiloxane. Mid/high polarity. Excellent for
separations of cis- and trans-fatty acid methyl esters. Bonded and
cross-linked. Solvent rinsable. 0.1mm ID. Length: 2000mm. Film: 0.1um.
Temperature Range: 40 to 220[degree]C. |
| Agilent 127-3212 |
Agilent HP-FFAP Columns Designed primarily
for the analysis of organic acids, free fatty acids, or samples that require
quantitation of acidic impurities. The stationary phase is modified with acid
to provide a very inert column that can accomodate the demanding analysis of
acids dissolved in water. |
| Agilent 127-32H2 |
Agilent HP-FFAP Columns Designed primarily
for the analysis of organic acids, free fatty acids, or samples that require
quantitation of acidic impurities. The stationary phase is modified with acid
to provide a very inert column that can accomodate the demanding analysis of
acids dissolved in water. |
| Agilent 127-5012 |
Agilent Column, DB-5, 0.10mm I.D. x 10m
Inner Diameter (mm I.D.): 0.10. Length (meter): 10. Film Thickness (um):
0.10. |
| Agilent 127-5012E |
Agilent GC Column, DB-1701 15m, 0.53mm,
1.00um, 5in cage |
| Agilent 127-5013 |
Agilent Column, DB-5, 0.10mm I.D. x 10m
Inner Diameter (mm I.D.): 0.10. Length (meter): 10. Film Thickness (um):
0.40. |
| Agilent 127-501E |
Agilent DB-5 HP-5; Ultra-2; SP-B-5. Wound
on 127mm cage. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column
with wide range of applications. Low bleed. Bonded and cross-linked. Solvent
rinsable. 0.1mm ID. Length: 1000mm. Film: 0.17um. Temperature Range: -60 to
325[degree]C. |
| Agilent 127-501EE |
Agilent DB-5 10m, 0.10mm, 0.17um, 5 inch
cage |
| Agilent 127-501N |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.1mm ID. Length: 1000mm. Film: 0.33um. Temperature Range: -60 to
325[degree]C. |
| Agilent 127-5022 |
Agilent Column, DB-5, 0.10mm I.D. x 20m
Inner Diameter (mm I.D.): 0.10. Length (meter): 20. Film Thickness (um):
0.10. |
| Agilent 127-5022E |
Agilent GC Column, DB-1 20m, 0.10mm,
0.40um, 5in cage |
| Agilent 127-5023 |
Agilent Column, DB-5, 0.10mm I.D. x 20m
Inner Diameter (mm I.D.): 0.10. Length (meter): 20. Film Thickness (um):
0.40. |
| Agilent 127-7012 |
Agilent DB-WAX HP-20M; SUPELCOWAX 10.
Polyethylene glycol. High polarity. Improves resolution of low boiling point
analyses. Column-to-column reproducibility. Bonded and cross-linked. Solvent
rinsable. 0.1mm ID. Length: 1000mm. Film: 0.1um. Temperature Range: 20 to
250[degree]C. |
| Agilent 127-7012E |
Agilent DB-WAX HP-20M. Wound on 127mm cage.
Polyethylene glycol. High polarity. Improves resolution of low boiling point
analyses. Column-to-column reproducibility. Bonded and cross-linked. Solvent
rinsable. With 127mm cage. 0.1mm ID. Length: 1000mm. Film: 0.1um. Temperature
Range: 20 to 250[degree]C. |
| Agilent 127-7013 |
Agilent DB-WAX HP-20M; SUPELCOWAX 10.
Polyethylene glycol. High polarity. Improves resolution of low boiling point
analyses. Column-to-column reproducibility. Bonded and cross-linked. Solvent
rinsable. 0.1mm ID. Length: 1000mm. Film: 0.2um. Temperature Range: 20 to
240[degree]C. |
| Agilent 127-7022 |
Agilent Column, DB-WAX, 0.10mm I.D. x 20m
Inner Diameter (mm I.D.): 0.10. Length (meter): 20. Film Thickness (um): 0.10.
Temperature Limits (oC): 20 to 250/260. |
| Agilent 127-7023 |
Agilent Column, DB-WAX, 0.10mm I.D. x 20m
Inner Diameter (mm I.D.): 0.10. Length (meter): 20. Film Thickness (um): 0.20.
Temperature Limits (oC): 20 to 250/260. |
| Agilent 127-7023E |
Agilent GC Column, DB-5 20m, 0.10mm,
0.10um, 5in cage |
| Agilent 127-7023FF |
Agilent DB-WAX 20m x 0.1mm ID, 0.2um, FF
Test. |
| Agilent 128-0122E |
Agilent GC Column, HP-1MS 25m, 0.2mm,
0.33um, 5in cage |
| Agilent 128-1012 |
Agilent Column, DB-1, 0.20mm I.D. x 12m
Inner Diameter (mm I.D.): 0.20. Length (meter): 12. Film Thickness (um): 0.33.
Temperature Limits (oC): -60 to 325/350. |
| Agilent 128-1022 |
Agilent Column, DB-1, 0.20mm I.D. x 25m
Inner Diameter (mm I.D.): 0.20. Length (meter): 25. Film Thickness (um): 0.33.
Temperature Limits (oC): -60 to 325/350. |
| Agilent 128-1052 |
Agilent Column, DB-1, 0.20mm I.D. x 50m
Inner Diameter (mm I.D.): 0.20. Length (meter): 50. Film Thickness (um): 0.33.
Temperature Limits (oC): -60 to 325/350. |
| Agilent 128-1056 |
Agilent Column, DB-Petro, 0.20mm I.D. x 50m
Inner Diameter (mm I.D.): 0.20. Length (meter): 50. Film Thickness (um): 0.50.
Temperature Limits (oC): -60 to 325/350, Similar Phases: Petrocol DH, HP-PONA,
SPB-1, 007-1, Rtx-1, MXT-1, PE-PONA. |
| Agilent 128-1212 |
Agilent DB-XLB MDN-12. Exceptionally low
bleed. Low polarity. Designed to inhibit column bleed at high temperatures.
Excellent inertness for active compounds. Bonded and cross-linked. Solvent
rinsable. 0.2mm ID. Length: 1200mm. Film: 0.33um. Temperature Range: 30 to
340[degree]C. |
| Agilent 128-1212E |
Agilent GC Column, DB-XLB 12m, 0.20mm,
0.33um, 5in cage |
| Agilent 128-1222 |
Agilent DB-XLB MDN-12. Exceptionally low
bleed. Low polarity. Designed to inhibit column bleed at high temperatures.
Excellent inertness for active compounds. Bonded and cross-linked. Solvent
rinsable. 0.2mm ID. Length: 2500mm. Film: 0.33um. Temperature Range: 30 to
340[degree]C. |
| Agilent 128-1324 |
Agilent Column, DB-624, 0.20mm I.D. x 25m
Diameter (mm I.D.): 0.20. Inner Length (meter): 25. Film Thickness (um): 1.12.
Temperature Limits (oC): -20 to 260, Similar Phases: VOCOL, NON-PAKD, AT-624,
Rtx-Volatiles, Rtx-502.2, PE-624, PE-502, 007-624, 007-502, HP-624, CP-624,
ZB-624. |
| Agilent 128-1324E |
Agilent GC Column, DB-624 20m, 0.18mm,
1.00um, 5in cage |
| Agilent 128-3812 |
Agilent DB-35ms Rtx-35; SPB-35. Equivalent
to (35%-phenyl)-methylpolysiloxane. Midpolarity. Low bleed, excellent inertness
for active compounds. Ideal for confirmational analyses. Bonded and
cross-linked. Solvent rinsable. 0.2mm ID. Length: 1500mm. Film: 0.33um.
Temperature Range: 50 to 340[degree]C. |
| Agilent 128-3822 |
Agilent DB-35ms Rtx-35; SPB-35. Equivalent
to (35%-phenyl)-methylpolysiloxane. Midpolarity. Low bleed, excellent inertness
for active compounds. Ideal for confirmational analyses. Bonded and
cross-linked. Solvent rinsable. 0.2mm ID. Length: 2500mm. Film: 0.33um.
Temperature Range: 50 to 340[degree]C. |
| Agilent 128-3822E |
Agilent GC Column, DB-1MS 25m, 0.20mm,
0.33um, 5in cage |
| Agilent 128-5012 |
Agilent Column, DB-5, 0.20mm I.D. x 12m
Inner Diameter (mm I.D.): 0.20. Length (meter): 12. Film Thickness (um):
0.33. |
| Agilent 128-5022 |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.2mm ID. Length: 2500mm. Film: 0.33um. Temperature Range: -60 to
325[degree]C. |
| Agilent 128-5022E |
Agilent GC Column, DB-1MS, 10m, 0.10mm,
0.40um, 5in cage |
| Agilent 128-5052 |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.2mm ID. Length: 5000mm. Film: 0.33um. Temperature Range: -60 to
325[degree]C. |
| Agilent 128-5052E |
Agilent GC Column, HP-PLOT Al2O3 KCL 30m,
0.25mm, 5in cage |
| Agilent 128-50H7 |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.2mm ID. Length: 1500mm. Film: 0.2um. Temperature Range: -60 to
325[degree]C. |
| Agilent 128-5522 |
Agilent Column, DB-5ms, 0.20mm I.D. x 25m
Inner Diameter (mm I.D.): 0.20. Length (meter): 25. Film Thickness (um): 0.33.
Temperature Limits (oC): -60 to 325/350, Similar Phases: Rtx-5MS, HP-5MS,
PTE-5, CP Sil 8 CBms, BPX-5, RH-5ms, HP-5 Trace. |
| Agilent 128-5552 |
Agilent Column, DB-5ms, 0.20mm I.D. x 50m
Inner Diameter (mm I.D.): 0.20. Length (meter): 50. Film Thickness (um): 0.33.
Temperature Limits (oC): -60 to 325/350, Similar Phases: Rtx-5MS, HP-5MS,
PTE-5, CP Sil 8 CBms, BPX-5, RH-5ms, HP-5 Trace. |
| Agilent 128-7032 |
Agilent DB-WAX HP-20M; SUPELCOWAX 10.
Polyethylene glycol. High polarity. Improves resolution of low boiling point
analyses. Column-to-column reproducibility. Bonded and cross-linked. Solvent
rinsable. 0.2mm ID. Length: 2500mm. Film: 0.2um. Temperature Range: 20 to
230[degree]C. |
| Agilent 128-7323 |
Agilent DB-WAXetr HP-20M; SUPELCOWAX 10.
Polyethylene glycol. Extended temperature range. High polarity. Excellent
column-to-column repeatability. Bonded and cross-linked. Solvent rinsable.
0.2mm ID. Length: 2500mm. Film: 0.4um. Temperature Range: 30 to
230[degree]C. |
| Agilent 128-8522 |
Agilent DB-5ms-EVDX Equivalent to
(5%-phenyl)-methylpolysiloxane. Low bleed for GC/MS analysis. Bonded and
cross-linked. Solvent rinsable. 0.2mm ID. Length: 2500mm. Film: 0.33um.
Temperature Range: -60 to 325[degree]C. |
| Agilent 12A-5015 |
Agilent DB-5 HP-5; Ultra-2; SP-B-5.
(5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide
range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable.
0.15mm ID. Length: 1000mm. Film: 1.2um. Temperature Range: -60 to
300[degree]C. |
| Agilent 12A-5015E |
Agilent GC Column, DB-5 10m, 0.10mm, 1.2um,
5in cage |
| Agilent 1300502506 |
Agilent Tube Probe to 6-port valve,
deactivated. |
| Agilent 145-1001 |
Agilent Column, DB-HT Sim Dis, 0.53mm I.D.
x 5m Inner Diameter (mm I.D.): 0.53. Length (meter): 5. Film Thickness (um):
0.15. Temperature Limits (oC): -6 to 400, Similar Phases: Petrocol EX2887,
CP-SimDist Ultimetal, MXT-2887, Rtx-2887, AC Controls High Temp Sim Dist,
AT-2887. |
| Agilent 145-1011 |
Agilent DB-PS1, ProSteel Excellent
inertness. Available in wide variety of stationary phases. Ideal for high
temperature analysis and process applications. Bonded and cross-linked. 0.53mm
ID. Length: 1500mm. Film: 0.15um. Temperature Range: -60 to 340[degree]C. |
| Agilent 145-1334 |
Agilent Column, DB-PS624, 0.53mm I.D. x 30m
Inner Diameter (mm.I.D.): 0.53. Length (meter): 30. Film Thickness (um): 3.00.
Temperature Limits (oC): -20 to 260. |
| Agilent 145-2814 |
Agilent DB-P2887, ProSteel Excellent
inertness. Available in wide variety of stationary phases. Ideal for high
temperature analysis and process applications. Bonded and cross-linked. 0.53mm
ID. Length: 1000mm. Film: 3um. Temperature Range: -60 to 350[degree]C. |
| Agilent 145-7032 |
Agilent DB-PSWAX, ProSteel Excellent
inertness. Available in wide variety of stationary phases. Ideal for high
temperature analysis and process applications. Bonded and cross-linked. 0.53mm
ID. Length: 3000mm. Film: 1um. Temperature Range: 20 to 230[degree]C. |
| Agilent 1460-1914 |
Agilent HP GCD/5971/72 MSD Parts and
Supplies Column wireform hanger. Kits. |
| Agilent 1530-2163 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 Tube, 1/16 in. with 1/8 in flare, stainless steel, 360 mm
long. |
| Agilent 1530-2167 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 Tube, 1/16 in. with 1/8 in. flare stainless steel, 520 mm
long. |
| Agilent 160-1010-1 |
Agilent Fused Silica Tubing, Deactivated
I.D. 0.1 mm, O.D. 0.19 mm Deactivated fused silica tubing has a nonpolar
chemical surface treatment - the preferred choice for most applications. J
& W tests to ensure deactivated tubing inertness. |
| Agilent 160-1010-10 |
Agilent Fused Silica Tubing, Deactivated
I.D. 0.1 mm, O.D. 0.19 mm Deactivated fused silica tubing has a nonpolar
chemical surface treatment - the preferred choice for most applications. J
& W tests to ensure deactivated tubing inertness. |
| Agilent 160-1010-5 |
Agilent Fused Silica Tubing, Deactivated
I.D. 0.1 mm, O.D. 0.19 mm Deactivated fused silica tubing has a nonpolar
chemical surface treatment - the preferred choice for most applications. J
& W tests to ensure deactivated tubing inertness. |
| Agilent 160-2200-10 |
Agilent Fused Silica Tubing, Undeactivated,
10 m, 0.20 mm I.D. Fused Silica Tubing, Undeactivated, Length: 10 m, Inner
Diameter: 0.20 mm. |
| Agilent 160-2200-5 |
Agilent Fused Silica Tubing, Undeactivated,
5 m, 0.20 mm I.D. Fused Silica Tubing, Undeactivated, Length: 5 m, Inner
Diameter: 0.20 mm. |
| Agilent 160-2205-1 |
Agilent Fused Silica Tubing, Deactivated, 1
m, 0.20 mm I.D. Fused Silica Tubing, Deactivated, Length: 1 m, Inner Diameter:
0.20 mm. |
| Agilent 160-2205-10 |
Agilent Fused Silica Tubing, Deactivated,
10 m, 0.20 mm I.D. Fused Silica Tubing, Deactivated, Length: 10 m, Inner
Diameter: 0.20 mm. |
| Agilent 160-2205-5 |
Agilent Fused Silica Tubing, Deactivated, 5
m, 0.20 mm I.D. Fused Silica Tubing, Deactivated, Length: 5 m, Inner Diameter:
0.20 mm. |
| Agilent 160-2250-10 |
Agilent Fused Silica Tubing, Undeactivated,
10 m, 0.25 mm I.D. Fused Silica Tubing, Undeactivated, Length: 10 m, Inner
Diameter: 0.25 mm. |
| Agilent 160-2250-5 |
Agilent Fused Silica Tubing, Undeactivated,
5 m, 0.25 mm I.D. Fused Silica Tubing, Undeactivated, Length: 5 m, Inner
Diameter: 0.25 mm. |
| Agilent 160-2255-1 |
Agilent Fused Silica Tubing, Deactivated, 1
m, 0.25 mm I.D. Fused Silica Tubing, Deactivated, Length: 1 m, Inner Diameter:
0.25 mm. |
| Agilent 160-2255-10 |
Agilent Capillary Guard Column Analytical
column for use as a guard column. I.D.: 0.25mm. |
| Agilent 160-2255-30 |
Agilent Fused Silica Tubing, Deactivated,
30 m, 0.25 mm I.D. Fused Silica Tubing, Deactivated, Length: 30 m, Inner
Diameter: 0.25 mm. |
| Agilent 160-2255-5 |
Agilent Fused Silica Tubing, Deactivated, 5
m, 0.25 mm I.D. Fused Silica Tubing, Deactivated, Length: 5 m, Inner Diameter:
0.25 mm. |
| Agilent 160-2320-10 |
Agilent Fused Silica Tubing, Undeactivated,
10 m, 0.32 mm I.D. Fused Silica Tubing, Undeactivated, Length: 10 m, Inner
Diameter: 0.32 mm. |
| Agilent 160-2320-5 |
Agilent Fused Silica Tubing, Undeactivated,
5 m, 0.32 mm I.D. Fused Silica Tubing, Undeactivated, Length: 5 m, Inner
Diameter: 0.32 mm. |
| Agilent 160-2325-1 |
Agilent Fused Silica Tubing, Deactivated, 1
m, 0.32 mm I.D. Fused Silica Tubing, Deactivated, Length: 1 m, Inner Diameter:
0.32 mm. |
| Agilent 160-2325-30 |
Agilent Fused Silica Tubing, Deactivated,
30 m, 0.32 mm I.D. Fused Silica Tubing, Deactivated, Length: 30 m, Inner
Diameter: 0.32 mm. |
| Agilent 160-2325-5 |
Agilent Fused Silica Tubing, Deactivated, 5
m, 0.32 mm I.D. Fused Silica Tubing, Deactivated, Length: 5 m, Inner Diameter:
0.32 mm. |
| Agilent 160-2450-5 |
Agilent Fused Silica Tubing, Undeactivated,
5 m, 0.45 mm I.D. Fused Silica Tubing, Undeactivated, Length: 5 m, Inner
Diameter: 0.45 mm. |
| Agilent 160-2455-1 |
Agilent Fused Silica Tubing, Deactivated, 1
m, 0.45 mm I.D. Fused Silica Tubing, Deactivated, Length: 1 m, Inner Diameter:
0.45 mm. |
| Agilent 160-2455-10 |
Agilent Fused Silica Tubing, Deactivated,
10 m, 0.45 mm I.D. Fused Silica Tubing, Deactivated, Length: 10 m, Inner
Diameter: 0.45 mm. |
| Agilent 160-2455-5 |
Agilent Fused Silica Tubing, Deactivated, 5
m, 0.45 mm I.D. Fused Silica Tubing, Deactivated, Length: 5 m, Inner Diameter:
0.45 mm. |
| Agilent 160-2530-10 |
Agilent Fused Silica Tubing, Undeactivated,
10 m, 0.53 mm I.D. Fused Silica Tubing, Undeactivated, Length: 10 m, Inner
Diameter: 0.53 mm. |
| Agilent 160-2530-5 |
Agilent Fused Silica Tubing, Undeactivated,
5 m, 0.53 mm I.D. Fused Silica Tubing, Undeactivated, Length: 5 m, Inner
Diameter: 0.53 mm. |
| Agilent 160-2535-1 |
Agilent Fused Silica Tubing, Deactivated, 1
m, 0.53 mm I.D. Fused Silica Tubing, Deactivated, Length: 1 m, Inner Diameter:
0.53 mm. |
| Agilent 160-2535-10 |
Agilent Fused Silica Tubing, Deactivated,
10 m, 0.53 mm I.D. Fused Silica Tubing, Deactivated, Length: 10 m, Inner
Diameter: 0.53 mm. |
| Agilent 160-2535-30 |
Agilent Fused Silica Tubing, Deactivated,
30 m, 0.53 mm I.D. Fused Silica Tubing, Deactivated, Length: 30 m, Inner
Diameter: 0.53 mm. |
| Agilent 160-2535-5 |
Agilent Fused Silica Tubing, Deactivated, 5
m, 0.53 mm I.D. Fused Silica Tubing, Deactivated, Length: 5 m, Inner Diameter:
0.53 mm. |
| Agilent 160-2610-10 |
Agilent Fused Silica Tubing, Undeactivated,
10 m, 0.18 mm I.D. Fused Silica Tubing, Undeactivated, Length: 10 m, Inner
Diameter: 0.18 mm. |
| Agilent 160-2610-5 |
Agilent Fused Silica Tubing, Undeactivated,
5 m, 0.18 mm I.D. Fused Silica Tubing, Undeactivated, Length: 5 m, Inner
Diameter: 0.18 mm. |
| Agilent 160-2615-1 |
Agilent Fused Silica Tubing, Deactivated, 1
m, 0.18 mm I.D. Fused Silica Tubing, Deactivated, Length: 1 m, Inner Diameter:
0.18 mm. |
| Agilent 160-2615-10 |
Agilent Fused Silica Tubing, Deactivated,
10 m, 0.18 mm I.D. Fused Silica Tubing, Deactivated, Length: 10 m, Inner
Diameter: 0.18 mm. |
| Agilent 160-2615-5 |
Agilent Fused Silica Tubing, Deactivated, 5
m, 0.18 mm I.D. Fused Silica Tubing, Deactivated, Length: 5 m, Inner Diameter:
0.18 mm. |
| Agilent 160-2634-10 |
Agilent Fused Silica Tubing, Undeactivated,
10 m, 0.10 mm I.D. Fused Silica Tubing, Undeactivated, Length: 10 m, Inner
Diameter: 0.10 mm. |
| Agilent 160-2634-5 |
Agilent Fused Silica Tubing, Undeactivated,
5 m, 0.10 mm I.D. Fused Silica Tubing, Undeactivated, Length: 5 m, Inner
Diameter: 0.10 mm. |
| Agilent 160-2635-1 |
Agilent Fused Silica Tubing, Deactivated, 1
m, 0.10 mm I.D. Fused Silica Tubing, Deactivated, Length: 1 m, Inner Diameter:
0.10 mm. |
| Agilent 160-2635-10 |
Agilent Fused Silica Tubing, Deactivated,
10 m, 0.10 mm I.D. Fused Silica Tubing, Deactivated, Length: 10 m, Inner
Diameter: 0.10 mm. |
| Agilent 160-2635-5 |
Agilent Fused Silica Tubing, Deactivated, 5
m, 0.10 mm I.D. Fused Silica Tubing, Deactivated, Length: 5 m, Inner Diameter:
0.10 mm. |
| Agilent 160-2644-10 |
Agilent Fused Silica Tubing, Undeactivated,
10 m, 0.075 mm I.D. Fused Silica Tubing, Undeactivated, Length: 10 m, Inner
Diameter: 0.075 mm. |
| Agilent 160-2644-5 |
Agilent Fused Silica Tubing, Undeactivated,
5 m, 0.075 mm I.D. Fused Silica Tubing, Undeactivated, Length: 5 m, Inner
Diameter: 0.075 mm. |
| Agilent 160-2650-10 |
Agilent Fused Silica Tubing, Undeactivated,
10 m, 0.05 mm I.D. Fused Silica Tubing, Undeactivated, Length: 10 m, Inner
Diameter: 0.05 mm. |
| Agilent 160-2650-5 |
Agilent Fused Silica Tubing, Undeactivated,
5 m, 0.05 mm I.D. Fused Silica Tubing, Undeactivated, Length: 5 m, Inner
Diameter: 0.05 mm. |
| Agilent 160-2655-1 |
Agilent Fused Silica Tubing, Deactivated, 1
m, 0.05 mm I.D. Fused Silica Tubing, Deactivated, Length: 1 m, Inner Diameter:
0.05 mm. |
| Agilent 160-2655-10 |
Agilent Fused Silica Tubing, Deactivated,
10 m, 0.05 mm I.D. Fused Silica Tubing, Deactivated, Length: 10 m, Inner
Diameter: 0.05 mm. |
| Agilent 160-2655-5 |
Agilent Fused Silica Tubing, Deactivated, 5
m, 0.05 mm I.D. Fused Silica Tubing, Deactivated, Length: 5 m, Inner Diameter:
0.05 mm. |
| Agilent 160-2660-5 |
Agilent Fused Silica Tubing, Undeactivated,
5 m, 0.02 mm I.D. Fused Silica Tubing, Undeactivated, Length: 5 m, Inner
Diameter: 0.02 mm. |
| Agilent 160-2815-5 |
Agilent High Temperature Fused Silica,
Deactivated, Tubing, 5 m, 0.05 mm I.D. High Temperature Fused Silica,
Deactivated, Tubing, Length: 5 m, Inner Diameter: 0.05 mm. |
| Agilent 160-2825-5 |
Agilent High Temperature Fused Silica,
Deactivated, Tubing, 5 m, 0.10 mm I.D. High Temperature Fused Silica,
Deactivated, Tubing, Length: 5 m, Inner Diameter: 0.10 mm. |
| Agilent 160-2845-10 |
Agilent High Temperature Fused Silica,
Deactivated, Tubing, 10 m, 0.25 mm I.D. High Temperature Fused Silica,
Deactivated, Tubing, Length: 10 m, Inner Diameter: 0.25 mm. |
| Agilent 160-2845-5 |
Agilent High Temperature Fused Silica,
Deactivated, Tubing, 5 m, 0.25 mm I.D. High Temperature Fused Silica,
Deactivated, Tubing, Length: 5 m, Inner Diameter: 0.25 mm. |
| Agilent 160-2855-10 |
Agilent High Temperature Fused Silica,
Deactivated, Tubing, 10 m, 0.32 mm I.D. High Temperature Fused Silica,
Deactivated, Tubing, Length: 10 m, Inner Diameter: 0.32 mm. |
| Agilent 160-2855-5 |
Agilent High Temperature Fused Silica,
Deactivated, Tubing, 5 m, 0.32 mm I.D. High Temperature Fused Silica,
Deactivated, Tubing, Length: 5 m, Inner Diameter: 0.32 mm. |
| Agilent 160-2865-10 |
Agilent High Temperature Fused Silica,
Deactivated, Tubing, 10 m, 0.53 mm I.D. High Temperature Fused Silica,
Deactivated, Tubing, Length: 10 m, Inner Diameter: 0.53 mm. |
| Agilent 160-2865-5 |
Agilent High Temperature Fused Silica,
Deactivated, Tubing, 5 m, 0.53 mm I.D. High Temperature Fused Silica,
Deactivated, Tubing, Length: 5 m, Inner Diameter: 0.53 mm. |
| Agilent 160-4535-5 |
Agilent ProSteel Stainless Steel Tubing,
Deactivated, 5 m, 0.53 mm I.D. ProSteel Stainless Steel Tubing, Deactivated,
Length: 5 m, Inner Diameter: 0.53 mm. |
| Agilent 18596-40015 |
Agilent Files, Cutters, and Replacement
Blades Tube cutter (1/8 to 5/8 in. od tubing). |
| Agilent 18710-20119 |
Agilent HP 5890 Detector Supplies Jet,
adaptable packed (0.46mm ID tip). |
| Agilent 18710-60170 |
Agilent HP 5880 Detector Supplies Flame
Ionization Detector (FID). Performance evaluation sample, FID solution of
0.033% C14, C15, and C16 normal alkanes in hexane. Three 0.5 ml ampoules. |
| Agilent 18711-60060 |
Agilent HP 5890 Detector Supplies TCD
Performance Evaluation Sample: C14, C15, and C16 (0.3%) in hexane. |
| Agilent 18713-60040 |
Agilent HP 5880 Detector Supplies Electron
Capture Detector (ECD). Performance evaluation sample, ECD. |
| Agilent 18713-60050 |
Agilent HP 5880 Detector Supplies Electron
Capture Detector (ECD). Wipe test kit, each kit will perform test four
times. |
| Agilent 18740-20800 |
Agilent HP 5890 Split/Splitless Multimode
Inlet Split/Splitless Inlet Parts. Reducing nut. |
| Agilent 18740-20880 |
Agilent HP 6890 Split/Splitless Inlet
Supplies Split/Splitless Inlet Supplies. Stainless steel seal. |
| Agilent 18740-20950 |
Agilent HP 5890 Detector Supplies TCD
column adapter seal. |
| Agilent 18740-20960 |
Agilent Adapter Seal For 1/8" FID. TCD
capillary column adapter. |
| Agilent 18740-60830 |
Agilent HP 5890 Packed Column Inlet
Supplies Septum-Purged Packed Column Inlet. Headspace septum retainer nut. |
| Agilent 18740-60835 |
Agilent HP 5890 Packed Column Inlet
Supplies Septum-Purged Packed Column Inlet. Septum retainer nut. |
| Agilent 18740-60840 |
Agilent Split Liner with Cup for Capillary
Inlet Systems 4mm ID. Volume: 800uL. For particulate samples. Retains
non-volatile contaminants. Borosilicate glass. Column packing (10% OV-1 on
80/100 Chromosorb), has a higher capacity for boiling than glass wool. Not for
use with electronic pressure control. |
| Agilent 18740-80190 |
Agilent Split Liner with Cup for Capillary
Inlet Systems 4mm ID. Volume: 800uL. For a wide range of molecular analyses.
Borosilicate glass. |
| Agilent 18740-80200 |
Agilent Inlet Liners Capillary Inlet System
Liners. Direct Liner. ID: 1.5 mm. Volume: 140 uL. Glass Type: Borosilicate.
Glass wool packing: No. Typical applications: Small (>0.5ul) volumes,
depending on solvent & conditions. Fast injection:. |
| Agilent 18740-80220 |
Agilent Splitless Liner for Capillary Inlet
Systems 2mm ID. Volume: 250uL. For small (>0.5ul) volumes, depending on
solvent and conditions. Quartz (Purity 8) glass. |
| Agilent 18789-60060 |
Agilent HP 5880 Detector Supplies Nitrogen
Phosphorous Detector (NPD). Performance evaluation sample, NPD. |
| Agilent 18789-80070 |
Agilent HP 5890 Detector Supplies Jets.
Packed wide-bore 0.030 in. id jet (for high-bleed applications). |
| Agilent 18801-60700 |
Agilent Perfomance evaluation sample for
FID Solution of 0.02-0.26% (v/v) of n-propanol, isobutanol, toluene, xylenes,
nonane, heptanol, decane, undecane, dodecane, and m-cresol in acetone. Two
1.0ml ampoules. |
| Agilent 18900-20250 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 Tube, 1/16 in. stainless steel, 280 mm long. |
| Agilent 18900-20280 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 Tube, 1/16 in. stainless steel, 400 mm long. |
| Agilent 18900-20281 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 Tube, 1/16 in. stainless steel, 575 mm long. |
| Agilent 18900-20300 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 Tube, 1/16 in. stainless steel, 560 mm long. |
| Agilent 18900-20850 |
Agilent Valve Tool For liner installation,
PTFE. A part for interfacing capillary columns to W series valves. |
| Agilent 18900-60640 |
Agilent Alcohol in Gasoline Qualitative
Petrochemical Standards. Test mixture containing approximately 1% each of
ethanol, isopropanol, n-propanol, sec-butanol, isobutyl alcohol, tert-amyl
alcohol, and n-butanol; 2% each of methanol and tert-butyl alcohol; and 3% MTBE
in gasoline. Three sealed 0. |
| Agilent 18900-80255 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 Tube, nickel, 1/16 in. with 1/8 in. bulkhead fitting, 460 mm
long. |
| Agilent 19091-20050 |
Agilent HP Deactivated Retention Gaps and
Column Accessories Uncoated Fused Silica Tubing. Inner Diam: 0.203 mm. Outer
Diam: 0.332 mm. Length: 50 m. |
| Agilent 19091-21050 |
Agilent HP Deactivated Retention Gaps and
Column Accessories Uncoated Fused Silica Tubing. Inner Diam: 0.315 mm. Outer
Diam: 0.440 mm. Length: 50 m. |
| Agilent 19091-60312 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.20mm. Length: 12m. Film Thickness: 0.33um. |
| Agilent 19091-60620E |
Agilent Fused Silica, Deactivated Wound on
127mm cage. Use as retention gaps, guard columns or transfer lines. 0.1mm ID.
Length: 1000mm. Temperature Range: 0 to 280[degree]C. |
| Agilent 19091-65020 |
Agilent Sadtler Retention Index Library
Retention Index Kit of Capillary Columns. Kit of the three columns used to
generate the RI data in the Sadtler Retention Index Library:. Column, 25 m x
0.32 mm (19091A-112). Column, 25 m x 0.32 mm (19091B-112). Column, 25 m x 0.32
mm (19091W-012). |
| Agilent 19091-80060 |
Agilent Cage for 68550 127mm. |
| Agilent 19091A-002 |
Agilent HP-Ultra 1 GC Column For analysis
of hydrocarbons, amines, and drugs requiring precise column-to-column
reproducibility. Use with the Sadtler Retention Index. Phase composition:
bonded dimethyl-polysiloxane. Temperature Range: -60 to 325[degree]C. I.D.:
0.2mm. Length: 25m. Film Thickness: 0.11um. |
| Agilent 19091A-005 |
Agilent HP-Ultra 1 GC column Inner Diam.:
0.2 mm. Length: 50 m. Film Thickness: 0.11 um. HP Ultra columns are
manufactured to the equivalent stringent specifications of the HP-1 and HP-5
columns, with even tighter tolerances for retention index and capacity
factor. |
| Agilent 19091A-012 |
Agilent HP-Ultra 1 GC Column For analysis
of hydrocarbons, amines, and drugs requiring precise column-to-column
reproducibility. Use with the Sadtler Retention Index. Phase composition:
bonded dimethyl-polysiloxane. Temperature Range: -60 to 325[degree]C. I.D.:
0.32mm. Length: 25m. Film Thickness: 0.17um. |
| Agilent 19091A-015 |
Agilent HP-Ultra 1 GC column Inner Diam.:
0.32 mm. Length: 50 m. Film Thickness: 0.17 um. HP Ultra columns are
manufactured to the equivalent stringent specifications of the HP-1 and HP-5
columns, with even tighter tolerances for retention index and capacity
factor. |
| Agilent 19091A-101 |
Agilent HP-Ultra 1 GC Column For analysis
of hydrocarbons, amines, and drugs requiring precise column-to-column
reproducibility. Use with the Sadtler Retention Index. Phase composition:
bonded dimethyl-polysiloxane. Temperature Range: -60 to 325[degree]C. I.D.:
0.2mm. Length: 12m. Film Thickness: 0.33um. |
| Agilent 19091A-102 |
Agilent HP-Ultra 1 GC Column For analysis
of hydrocarbons, amines, and drugs requiring precise column-to-column
reproducibility. Use with the Sadtler Retention Index. Phase composition:
bonded dimethyl-polysiloxane. Temperature Range: -60 to 325[degree]C. I.D.:
0.2mm. Length: 25m. Film Thickness: 0.33um. |
| Agilent 19091A-102E |
Agilent GC Column |
| Agilent 19091A-105 |
Agilent HP-Ultra 1 GC Column For analysis
of hydrocarbons, amines, and drugs requiring precise column-to-column
reproducibility. Use with the Sadtler Retention Index. Phase composition:
bonded dimethyl-polysiloxane. Temperature Range: -60 to 325[degree]C. I.D.:
0.2mm. Length: 50m. Film Thickness: 0.33um. |
| Agilent 19091A-108 |
Agilent Ultra 1 17m, 0.20mm, 0.33 um |
| Agilent 19091A-112 |
Agilent HP-Ultra 1 GC Column For analysis
of hydrocarbons, amines, and drugs requiring precise column-to-column
reproducibility. Use with the Sadtler Retention Index. Phase composition:
bonded dimethyl-polysiloxane. Temperature Range: -60 to 325[degree]C. I.D.:
0.32mm. Length: 25m. Film Thickness: 0.52um. |
| Agilent 19091A-115 |
Agilent HP-Ultra 1 GC Column For analysis
of hydrocarbons, amines, and drugs requiring precise column-to-column
reproducibility. Use with the Sadtler Retention Index. Phase composition:
bonded dimethyl-polysiloxane. Temperature Range: -60 to 325[degree]C. I.D.:
0.32mm. Length: 50m. Film Thickness: 0.52um. |
| Agilent 19091B-002 |
Agilent HP-Ultra 2 GC Column For analyzing
FAMEs, alkaloids, and drugs requiring column-to-column reproducibility. Use
with the Sadtler Retention Index. Phase composition: bonded 5% diphenyl, 95%
dimethyl siloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.2mm. Length:
25m. Film Thickness: 0.11um. |
| Agilent 19091B-005 |
Agilent HP-Ultra 2 GC Column For analyzing
FAMEs, alkaloids, and drugs requiring column-to-column reproducibility. Use
with the Sadtler Retention Index. Phase composition: bonded 5% diphenyl, 95%
dimethyl siloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.2mm. Length:
50m. Film Thickness: 0.11um. |
| Agilent 19091B-012 |
Agilent HP-Ultra 2 GC Column For analyzing
FAMEs, alkaloids, and drugs requiring column-to-column reproducibility. Use
with the Sadtler Retention Index. Phase composition: bonded 5% diphenyl, 95%
dimethyl siloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.32mm.
Length: 25m. Film Thickness: 0.17um. |
| Agilent 19091B-012E |
Agilent HP-Ultra 2 DB-5. Wound on 127mm
cage. (5%-phenyl)-methylsiloxane. Bonded and cross-linked. Intended for use
with Sadtler Retention Index Library. 0.32mm ID. Length: 2500mm. Film: 0.17um.
Temperature Range: -60 to 325[degree]C. |
| Agilent 19091B-015 |
Agilent HP-Ultra 2 GC column Inner Diam.:
0.32 mm. Length: 50 m. Film Thickness: 0.17 um. HP Ultra columns are
manufactured to the equivalent stringent specifications of the HP-1 and HP-5
columns, with even tighter tolerances for retention index and capacity
factor. |
| Agilent 19091B-101 |
Agilent HP-Ultra 2 GC Column For analyzing
FAMEs, alkaloids, and drugs requiring column-to-column reproducibility. Use
with the Sadtler Retention Index. Phase composition: bonded 5% diphenyl, 95%
dimethyl siloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.2mm. Length:
12m. Film Thickness: 0.33um. |
| Agilent 19091B-102 |
Agilent HP-Ultra 2 GC Column For analyzing
FAMEs, alkaloids, and drugs requiring column-to-column reproducibility. Use
with the Sadtler Retention Index. Phase composition: bonded 5% diphenyl, 95%
dimethyl siloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.2mm. Length:
25m. Film Thickness: 0.33um. |
| Agilent 19091B-102E |
Agilent HP-Ultra 2 DB-5. Wound on 127mm
cage. (5%-phenyl)-methylsiloxane. Bonded and cross-linked. Intended for use
with Sadtler Retention Index Library. 0.2mm ID. Length: 2500mm. Film: 0.33um.
Temperature Range: -60 to 325[degree]C. |
| Agilent 19091B-105 |
Agilent HP-Ultra 2 GC Column For analyzing
FAMEs, alkaloids, and drugs requiring column-to-column reproducibility. Use
with the Sadtler Retention Index. Phase composition: bonded 5% diphenyl, 95%
dimethyl siloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.2mm. Length:
50m. Film Thickness: 0.33um. |
| Agilent 19091B-105E |
Agilent GC Column, DB-1301 60m, 0.32mm,
1.00um, 5in cage |
| Agilent 19091B-112 |
Agilent HP-Ultra 2 GC Column For analyzing
FAMEs, alkaloids, and drugs requiring column-to-column reproducibility. Use
with the Sadtler Retention Index. Phase composition: bonded 5% diphenyl, 95%
dimethyl siloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.32mm.
Length: 25m. Film Thickness: 0.52um. |
| Agilent 19091B-115 |
Agilent HP-Ultra 2 GC column Inner Diam.:
0.32 mm. Length: 50 m. Film Thickness: 0.52 um. HP Ultra columns are
manufactured to the equivalent stringent specifications of the HP-1 and HP-5
columns, with even tighter tolerances for retention index and capacity
factor. |
| Agilent 19091B-115E |
Agilent GC Column, DB-1701 60m, .53mm,
1.0um, 5in cage |
| Agilent 19091F-102 |
Agilent HP-FFAP PEG Capillary GC Column
Acid modified PEG column for analysis of acids, acrylates, alcohols, aldehydes,
ketones, nitriles, free-fatty acids. Phase composition: bonded polyethylene
glycol-TPA. Temperature Range: 60 to 240[degree]C. I.D.: 0.2mm. Length: 25m.
Film Thickness: 0.3um. |
| Agilent 19091F-102E |
Agilent GC Column, DB-WAX 20m, 0.18mm,
0.30um, 5in cage |
| Agilent 19091F-105 |
Agilent HP-FFAP PEG Capillary GC Column
Acid modified PEG column for analysis of acids, acrylates, alcohols, aldehydes,
ketones, nitriles, free-fatty acids. Phase composition: bonded polyethylene
glycol-TPA. Temperature Range: 60 to 240[degree]C. I.D.: 0.2mm. Length: 50m.
Film Thickness: 0.3um. |
| Agilent 19091F-105E |
Agilent HP-FFAP Stabilwax-DA. Wound on
127mm cage. Nitroterephthalic acid modified polyethylene glycol. High polarity.
Designed for the analysis of volatile fatty acids and phenols. Bonded and
cross-linked. Solvent rinsable. 0.2mm ID. Length: 5000mm. Film: 0.25um.
Temperature Range: 60 to 240[degree]C. |
| Agilent 19091F-112 |
Agilent HP-FFAP PEG Capillary GC Column
Acid modified PEG column for analysis of acids, acrylates, alcohols, aldehydes,
ketones, nitriles, free-fatty acids. Phase composition: bonded polyethylene
glycol-TPA. Temperature Range: 60 to 240[degree]C. I.D.: 0.32mm. Length: 25m.
Film Thickness: 0.5um. |
| Agilent 19091F-112E |
Agilent HP-FFAP Stabilwax-DA. Wound on
127mm cage. Nitroterephthalic acid modified polyethylene glycol. High polarity.
Designed for the analysis of volatile fatty acids and phenols. Bonded and
cross-linked. Solvent rinsable. 0.32mm ID. Length: 2500mm. Film: 0.5um.
Temperature Range: 60 to 240[degree]C. |
| Agilent 19091F-115 |
Agilent HP-FFAP PEG Capillary GC Column
Acid modified PEG column for analysis of acids, acrylates, alcohols, aldehydes,
ketones, nitriles, free-fatty acids. Phase composition: bonded polyethylene
glycol-TPA. Temperature Range: 60 to 240[degree]C. I.D.: 0.32mm. Length: 50m.
Film Thickness: 0.5um. |
| Agilent 19091F-115E |
Agilent HP-FFAP Stabilwax-DA. Wound on
127mm cage. Nitroterephthalic acid modified polyethylene glycol. High polarity.
Designed for the analysis of volatile fatty acids and phenols. Bonded and
cross-linked. Solvent rinsable. 0.32mm ID. Length: 5000mm. Film: 0.5um.
Temperature Range: 60 to 240[degree]C. |
| Agilent 19091F-413 |
Agilent HP-FFAP GC column Inner Diam.: 0.32
mm. Length: 30 m. Film Thickness: 0.25 um. The order of polarity is as follows:
HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more
polar than, the HP-20M (Carbowax 20M) columns. Similar Phases. |
| Agilent 19091F-433 |
Agilent HP-FFAP GC column Inner Diam.: 0.25
mm. Length: 30 m. Film Thickness: 0.25 um. The order of polarity is as follows:
HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more
polar than, the HP-20M (Carbowax 20M) columns. Similar Phases. |
| Agilent 19091F-433E |
Agilent HP-FFAP Stabilwax-DA. Wound on
127mm cage. Nitroterephthalic acid modified polyethylene glycol. High polarity.
Designed for the analysis of volatile fatty acids and phenols. Bonded and
cross-linked. Solvent rinsable. 0.25mm ID. Length: 3000mm. Film: 0.25um.
Temperature Range: 60 to 240[degree]C. |
| Agilent 19091G-113 |
Agilent HP35 Capillary GC Column
Intermediate polarity column for analysis of amines, PCBs, pesticides,
pharmaceuticals. Use for EPA Method 8081 and USP G-42. Phase composition: 35%
diphenyl, 65% methyl siloxane. Temperature Range: -40 to 300/320[degree]C. I.D.
0.32mm. Length 30m. Thickness 0.25um. |
| Agilent 19091G-131 |
Agilent HP35 Capillary GC Column
Intermediate polarity column for analysis of amines, PCBs, pesticides,
pharmaceuticals. Use for EPA Method 8081 and USP G-42. Phase composition: 35%
diphenyl, 65% methyl siloxane. Temperature Range: -40 to 300/320[degree]C. I.D.
0.25mm. Length 15m. Thickness 0.25um. |
| Agilent 19091G-131E |
Agilent GC Column, HP-35 15m, 0.25mm,
0.25um, 5in cage |
| Agilent 19091G-133 |
Agilent HP35 Capillary GC Column
Intermediate polarity column for analysis of amines, PCBs, pesticides,
pharmaceuticals. Use for EPA Method 8081 and USP G-42. Phase composition: 35%
diphenyl, 65% methyl siloxane. Temperature Range: -40 to 300/320[degree]C. I.D.
0.25mm. Length 30m. Thickness 0.25um. |
| Agilent 19091G-213 |
Agilent HP-35 GC column Inner Diam.: 0.32
mm. Length: 30 m. Film thickness: 0.50 um. Similar Phases:. DB-35, Rtx-35,
SPB-35, SPB-608, AT-35, Sup-Herb. Temperature Range isothermal/temperature
programmed. 40 to 300/320[degree]C. 40 to 280/300[degree]C for 0.53 mm
i.d. |
| Agilent 19091G-B133 |
Agilent HP-Chiral-10B GC column Inner
Diam.: 0.25 mm. Length: 30 m. Film Thickness: 0.25 um. Cyclodextrin: 10 %.
Similar Phases. CP Chirasil Dex CB, CP-Cyclodextrin-2,3,6,M19, Rt-DEXm,
DEX110/120. Temperature Range isothermal/temperature programmed. 30 to
240/250[degree]C. |
| Agilent 19091G-B213 |
Agilent HP-Chiral-20B GC column Inner
Diam.: 0.32 mm. Length: 30 m. Film Thickness: 0.25 um. Cyclodextrin: 20 %.
Similar Phases. CP Chirasil Dex CB, CP-Cyclodextrin-2,3,6,M19, Rt-DEXm,
DEX110/120. Temperature Range isothermal/temperature programmed. 30 to
240/250[degree]C. |
| Agilent 19091G-B213E |
Agilent GC Column, DB-210 30m, 0.53mm,
1.00um, 5in cage |
| Agilent 19091G-B233 |
Agilent HP-Chiral-20B GC column Inner
Diam.: 0.25 mm. Length: 30 m. Film Thickness: 0.25 um. Cyclodextrin: 20 %.
Similar Phases. CP Chirasil Dex CB, CP-Cyclodextrin-2,3,6,M19, Rt-DEXm,
DEX110/120. Temperature Range isothermal/temperature programmed. 30 to
240/250[degree]C. |
| Agilent 19091G-B233E |
Agilent GC Column, DB-5MS 30m, 0.25mm,
0.50um, 5in cage |
| Agilent 19091J-002 |
Agilent HP-5 GC column Inner Diam.: 0.2 mm.
Length: 25 m. Film thickness: 0.11 um. Similar Phases:. DB-5, Rtx-5, SPB-5,
PTE-5, CP-Sil 8CB, SE-54, DB-5ht, DB-5.625, Mtx-5, OV-5, SE-52, GC-5, 007-2,
RSL-200, MDN-5, BP-5. Temperature Range isothermal/temperature programmed. -60
to 325/350[degree]C. |
| Agilent 19091J-005 |
Agilent HP-5 GC column Inner Diam.: 0.2 mm.
Length: 50 m. Film thickness: 0.11 um. Similar Phases:. DB-5, Rtx-5, SPB-5,
PTE-5, CP-Sil 8CB, SE-54, DB-5ht, DB-5.625, Mtx-5, OV-5, SE-52, GC-5, 007-2,
RSL-200, MDN-5, BP-5. Temperature Range isothermal/temperature programmed. -60
to 325/350[degree]C. |
| Agilent 19091J-012 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D.
0.32mm. Length 25m. Thickness: 0.17um. |
| Agilent 19091J-012E |
Agilent GC Column, DB-35MS 25m, 0.20mm,
0.33um, 5in cage |
| Agilent 19091J-015 |
Agilent HP-5 GC column Inner Diam.: 0.2 mm.
Length: 50 m. Film thickness: 0.17 um. Similar Phases:. DB-5, Rtx-5, SPB-5,
PTE-5, CP-Sil 8CB, SE-54, DB-5ht, DB-5.625, Mtx-5, OV-5, SE-52, GC-5, 007-2,
RSL-200, MDN-5, BP-5. Temperature Range isothermal/temperature programmed. -60
to 325/350[degree]C. |
| Agilent 19091J-101 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D.
0.2mm. Length 12m. Thickness: 0.33um. |
| Agilent 19091J-102 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D.
0.2mm. Length 25m. Thickness: 0.33um. |
| Agilent 19091J-102E |
Agilent GC Column |
| Agilent 19091J-105 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D.
0.2mm. Length 50m. Thickness: 0.33um. |
| Agilent 19091J-105E |
Agilent GC Column, DB-225 30m, 0.53mm,
1.00um, 5in cage |
| Agilent 19091J-108 |
Agilent HP-5 17m, 0.20mm, 0.33 um |
| Agilent 19091J-112 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D.
0.32mm. Length 25m. Thickness: 0.52um. |
| Agilent 19091J-112E |
Agilent HP5 Capillary GC Column On 127mm
cage. Nonpolar. For analysis of semivolatives, alkaloids, drugs, FAMEs,
pesticides, herbicides, halogenated compounds, unknown samples. Composition:
bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C.
I.D. 0.32mm. Length 25m. Film: 0.52um. |
| Agilent 19091J-113 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D.
0.32mm. Length 30m. Thickness: 0.5um. |
| Agilent 19091J-113E |
Agilent GC Column, HP-5MS, 25m, 0.32mm,
0.52um, 5in cage |
| Agilent 19091J-115 |
Agilent HP-5 GC column Inner Diam.: 0.2 mm.
Length: 50 m. Film thickness: 0.52 um. Similar Phases:. DB-5, Rtx-5, SPB-5,
PTE-5, CP-Sil 8CB, SE-54, DB-5ht, DB-5.625, Mtx-5, OV-5, SE-52, GC-5, 007-2,
RSL-200, MDN-5, BP-5. Temperature Range isothermal/temperature programmed. -60
to 325/350[degree]C. |
| Agilent 19091J-202 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D.
0.2mm. Length 25m. Thickness: 0.5um. |
| Agilent 19091J-205 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D.
0.2mm. Length 50m. Thickness: 0.5um. |
| Agilent 19091J-212 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D.
0.32mm. Length 25m. Thickness: 1.05um. |
| Agilent 19091J-213 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D.
0.32mm. Length 30m. Thickness: 1um. |
| Agilent 19091J-213E |
Agilent HP5 Capillary GC Column Wound on
127mm cage. Nonpolar. For analysis of semivolatives, alkaloids, FAMEs,
pesticides, herbicides, halogenated compounds, unknown samples. Phase
composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to
325/350[degree]C. I.D. 0.32mm. Length 30m. Film: 1um. |
| Agilent 19091J-215 |
Agilent HP-5 GC column Inner Diam.: 0.2 mm.
Length: 50 m. Film thickness: 1.05 um. Similar Phases:. DB-5, Rtx-5, SPB-5,
PTE-5, CP-Sil 8CB, SE-54, DB-5ht, DB-5.625, Mtx-5, OV-5, SE-52, GC-5, 007-2,
RSL-200, MDN-5, BP-5. Temperature Range isothermal/temperature programmed. -60
to 325/350[degree]C. |
| Agilent 19091J-215E |
Agilent GC Column, DB-1 40m, 0.18mm,
0.40um, 5in cage |
| Agilent 19091J-216 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D.
0.32mm. Length 60m. Thickness: 1um. |
| Agilent 19091J-216E |
Agilent GC Column, DB-23 60m, 0.25mm,
0.25um, 5in cage |
| Agilent 19091J-231 |
Agilent HP-5 GC column Inner Diam.: 0.25
mm. Length: 15 m. Film thickness: 1.0 um. Similar Phases:. DB-5, Rtx-5, SPB-5,
PTE-5, CP-Sil 8CB, SE-54, DB-5ht, DB-5.625, Mtx-5, OV-5, SE-52, GC-5, 007-2,
RSL-200, MDN-5, BP-5. Temperature Range isothermal/temperature programmed. -60
to 325/350[degree]C. |
| Agilent 19091J-233 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D.
0.25mm. Length 30m. Thickness: 1um. |
| Agilent 19091J-236 |
Agilent HP5 Capillary GC Column Nonpolar.
For analysis of semivolatives, alkaloids, FAMEs, pesticides, herbicides,
halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl,
95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.25mm. Length
60m. Thickness: 1um. |
| Agilent 19091J-236E |
Agilent HP5 Capillary GC Column Wound on
127mm cage. Nonpolar. For analysis of semivolatives, alkaloids, FAMEs,
pesticides, herbicides, halogenated compounds, unknown samples. Composition:
bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C.
I.D. 0.25mm. Length 60m. Thickness: 1um. |
| Agilent 19091J-313 |
Agilent HP-5 GC column Inner Diam.: 0.32
mm. Length: 30 m. Film thickness: 0.1 um. Similar Phases:. DB-5, Rtx-5, SPB-5,
PTE-5, CP-Sil 8CB, SE-54, DB-5ht, DB-5.625, Mtx-5, OV-5, SE-52, GC-5, 007-2,
RSL-200, MDN-5, BP-5. Temperature Range isothermal/temperature programmed. -60
to 325/350[degree]C. |
| Agilent 19091J-333 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D.
0.25mm. Length 30m. Thickness: 0.1um. |
| Agilent 19091J-411 |
Agilent HP5 Capillary GC Column Nonpolar.
For analysis of semivolatives, alkaloids, FAMEs, pesticides, herbicides,
halogenated compounds, unknown samples. Composition: bonded 5% phenyl, 95%
dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.32mm. Length 15m.
Thickness: 0.25um. |
| Agilent 19091J-413 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D.
0.32mm. Length 30m. Thickness: 0.25um. |
| Agilent 19091J-413E |
Agilent HP5 Capillary GC Column Wound on
127mm cage. Nonpolar. For analysis of semivolatives, alkaloids, FAMEs,
pesticides, herbicides, halogenated compounds, unknown samples. Composition:
bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C.
I.D. 0.32mm. Length 30m. Film: 0.25um. |
| Agilent 19091J-416 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D.
0.32mm. Length 60m. Thickness: 0.25um. |
| Agilent 19091J-431 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D.
0.25mm. Length 15m. Thickness: 0.25um. |
| Agilent 19091J-431E |
Agilent GC Column, HP-5 15m, 0.25mm,
0.25um, 5in cage |
| Agilent 19091J-433 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D.
0.25mm. Length 30m. Thickness: 0.25um. |
| Agilent 19091J-433E |
Agilent HP5 Capillary GC Column Wound on
127mm cage. Nonpolar. For analysis of semivolatives, alkaloids, FAMEs,
pesticides, herbicides, halogenated compounds, unknown samples. Composition:
bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C.
I.D. 0.25mm. Length 30m. Film: 0.25um. |
| Agilent 19091J-436 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D.
0.25mm. Length 60m. Thickness: 0.25um. |
| Agilent 19091J-436E |
Agilent GC Column |
| Agilent 19091J-577 |
Agilent Hp-5, 20M, 0.18Mm, 0.18Um |
| Agilent 19091L-101 |
Agilent HP-50+ GC column Inner Diam.: 0.20
mm. Length: 12 m. Film thickness: 0.31 um. Similar Phases:. DB-17, Rtx-50,
SP-2250, DB-17ht, SPB-50, 007-17, CP-Sil 19, CP-Sil 24CBRSL-300, AT-50, OV-17,
BPX-50. Temperature Range isothermal/temperature programmed. 40 to
280/300[degree]C. |
| Agilent 19091L-113 |
Agilent HP50 Capillary GC Column
Midpolarity. For confirmational analyses. Composition: bonded (50%
phenyl)-methylpolysiloxane. Range: 40 to 280/300[degree]C. I.D.: 0.32mm.
Length: 30m. Film: 0.5um. |
| Agilent 19091L-133 |
Agilent HP-50+ GC column Inner Diam.: 0.25
mm. Length: 30 m. Film thickness: 0.5 um. Similar Phases:. DB-17, Rtx-50,
SP-2250, DB-17ht, SPB-50, 007-17, CP-Sil 19, CP-Sil 24CBRSL-300, AT-50, OV-17,
BPX-50. Temperature Range isothermal/temperature programmed. 40 to
280/300[degree]C. |
| Agilent 19091L-333 |
Agilent HP-50+ GC column Inner Diam.: 0.25
mm. Length: 30 m. Film thickness: 0.15 um. Similar Phases:. DB-17, Rtx-50,
SP-2250, DB-17ht, SPB-50, 007-17, CP-Sil 19, CP-Sil 24CBRSL-300, AT-50, OV-17,
BPX-50. Temperature Range isothermal/temperature programmed. 40 to
280/300[degree]C. |
| Agilent 19091L-413 |
Agilent HP-50+ GC column Inner Diam.: 0.32
mm. Length: 30 m. Film thickness: 0.25 um. Similar Phases:. DB-17, Rtx-50,
SP-2250, DB-17ht, SPB-50, 007-17, CP-Sil 19, CP-Sil 24CBRSL-300, AT-50, OV-17,
BPX-50. Temperature Range isothermal/temperature programmed. 40 to
280/300[degree]C. |
| Agilent 19091L-413E |
Agilent GC Column |
| Agilent 19091L-416 |
Agilent HP-50+ GC column Inner Diam.: 0.32
mm. Length: 60 m. Film thickness: 0.25 um. Similar Phases:. DB-17, Rtx-50,
SP-2250, DB-17ht, SPB-50, 007-17, CP-Sil 19, CP-Sil 24CBRSL-300, AT-50, OV-17,
BPX-50. Temperature Range isothermal/temperature programmed. 40 to
280/300[degree]C. |
| Agilent 19091L-431 |
Agilent HP-50+ GC column Inner Diam.: 0.25
mm. Length: 15 m. Film thickness: 0.25 um. Similar Phases:. DB-17, Rtx-50,
SP-2250, DB-17ht, SPB-50, 007-17, CP-Sil 19, CP-Sil 24CBRSL-300, AT-50, OV-17,
BPX-50. Temperature Range isothermal/temperature programmed. 40 to
280/300[degree]C. |
| Agilent 19091L-433 |
Agilent HP-50+ GC column Inner Diam.: 0.25
mm. Length: 30 m. Film thickness: 0.25 um. Similar Phases:. DB-17, Rtx-50,
SP-2250, DB-17ht, SPB-50, 007-17, CP-Sil 19, CP-Sil 24CBRSL-300, AT-50, OV-17,
BPX-50. Temperature Range isothermal/temperature programmed. 40 to
280/300[degree]C. |
| Agilent 19091L-577 |
Agilent Hp-50+, 20M, 0.18Mm, 0.18Um |
| Agilent 19091N-013 |
Agilent HP-INNOWax GC Column HP-20M;
SUPELCOWAX 10. Polyethylene glycol. High polarity. Column to column
repeatability. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length:
3000mm. Film: 0.15um. Temperature Range: 40 to 260/270[degree]C. |
| Agilent 19091N-033 |
Agilent HP-INNOWax GC column Inner Diam.:
0.25 mm. Length: 30 m. Film Thickness 0.15 um. The order of polarity is as
follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn
are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases. |
| Agilent 19091N-036 |
Agilent HP-INNOWax GC column Inner Diam.:
0.25 mm. Length: 60 m. Film Thickness 0.15 um. The order of polarity is as
follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn
are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases. |
| Agilent 19091N-102 |
Agilent HP-INNOWax GC column Inner Diam.:
0.2 mm. Length: 25 m. Film Thickness 0.2 um. The order of polarity is as
follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn
are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases. |
| Agilent 19091N-105 |
Agilent HP-INNOWax GC column Inner Diam.:
0.2 mm. Length: 50 m. Film Thickness: 0.2 um. The order of polarity is as
follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn
are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases. |
| Agilent 19091N-105E |
Agilent GC Column, HP-5 50m, 0.20mm,
0.33um, 5in cage |
| Agilent 19091N-111 |
Agilent HP-INNOWax GC column Inner Diam.:
0.32 mm. Length: 15 m. Film Thickness 0.25 um. The order of polarity is as
follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn
are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases. |
| Agilent 19091N-113 |
Agilent HP-INNOWax PEG Capillary GC Column
PEG column for the analysis of alcohols, aromatics, essential oils, and free
acids. Phase composition: INNOphase* bonded polyethylene glycol. Temperature
Range: 40 to 260[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness:
0.25um. |
| Agilent 19091N-113E |
Agilent HP-INNOWax PEG Capillary GC Column
Wound on 127mm cage. PEG column for the analysis of alcohols, aromatics,
essential oils, and free acids. Phase composition: INNOphase* bonded
polyethylene glycol. Temperature Range: 40 to 260[degree]C. I.D.: 0.32mm.
Length: 30m. Film Thickness: 0.25um. |
| Agilent 19091N-116 |
Agilent HP-INNOWax GC column Inner Diam.:
0.32 mm. Length: 60 m. Film Thickness 0.25 um. The order of polarity is as
follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn
are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases. |
| Agilent 19091N-131 |
Agilent HP-INNOWax PEG Capillary GC Column
PEG column for the analysis of alcohols, aromatics, essential oils, and free
acids. Phase composition: INNOphase* bonded polyethylene glycol. Temperature
Range: 40 to 260[degree]C. I.D.: 0.25mm. Length: 15m. Film Thickness:
0.25um. |
| Agilent 19091N-131E |
Agilent GC Column, HP-INNOWax 15m, 0.25mm,
0.25um, 5in cage |
| Agilent 19091N-133 |
Agilent HP-INNOWax PEG Capillary GC Column
PEG column for the analysis of alcohols, aromatics, essential oils, and free
acids. Phase composition: INNOphase* bonded polyethylene glycol. Temperature
Range: 40 to 260[degree]C. I.D.: 0.25mm. Length: 30m. Film Thickness:
0.25um. |
| Agilent 19091N-133E |
Agilent HP-INNOWax PEG Capillary GC Column
Wound on 127mm cage. PEG column for the analysis of alcohols, aromatics,
essential oils, and free acids. Phase composition: INNOphase* bonded
polyethylene glycol. Temperature Range: 40 to 260[degree]C. I.D.: 0.25mm.
Length: 30m. Film Thickness: 0.25um. |
| Agilent 19091N-136 |
Agilent HP-INNOWax PEG Capillary GC Column
PEG column for the analysis of alcohols, aromatics, essential oils, and free
acids. Phase composition: INNOphase* bonded polyethylene glycol. Temperature
Range: 40 to 260[degree]C. I.D.: 0.25mm. Length: 60m. Film Thickness:
0.25um. |
| Agilent 19091N-136E |
Agilent GC Column |
| Agilent 19091N-202 |
Agilent HP-INNOWax PEG Capillary GC Column
PEG column for the analysis of alcohols, aromatics, essential oils, and free
acids. Phase composition: INNOphase* bonded polyethylene glycol. Temperature
Range: 40 to 260[degree]C. I.D.: 0.2mm. Length: 25m. Film Thickness:
0.4um. |
| Agilent 19091N-205 |
Agilent HP-INNOWax GC column Inner Diam.:
0.2 mm. Length: 50 m. Film Thickness: 0.4 um. The order of polarity is as
follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn
are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases. |
| Agilent 19091N-205E |
Agilent GC Column, HP-1, 50m, 0.20mm,
0.33um, 5in cage |
| Agilent 19091N-213 |
Agilent HP-INNOWax PEG Capillary GC Column
PEG column for the analysis of alcohols, aromatics, essential oils, and free
acids. Phase composition: INNOphase* bonded polyethylene glycol. Temperature
Range: 40 to 260[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness:
0.5um. |
| Agilent 19091N-216 |
Agilent HP-INNOWax PEG Capillary GC Column
PEG column for the analysis of alcohols, aromatics, essential oils, and free
acids. Phase composition: INNOphase* bonded polyethylene glycol. Temperature
Range: 40 to 260[degree]C. I.D.: 0.32mm. Length: 60m. Film Thickness:
0.5um. |
| Agilent 19091N-216E |
Agilent HP-INNOWax PEG Capillary GC Column
Wound on 127mm cage. PEG column for the analysis of alcohols, aromatics,
essential oils, and free acids. Phase composition: INNOphase* bonded
polyethylene glycol. Temperature Range: 40 to 260[degree]C. I.D.: 0.32mm.
Length: 60m. Film Thickness: 0.5um. |
| Agilent 19091N-231 |
Agilent HP-INNOWax GC column Inner Diam.:
0.25 mm. Length: 15 m. Film Thickness: 0.5 um. The order of polarity is as
follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn
are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases. |
| Agilent 19091N-233 |
Agilent HP-INNOWax PEG Capillary GC Column
PEG column for the analysis of alcohols, aromatics, essential oils, and free
acids. Phase composition: INNOphase* bonded polyethylene glycol. Temperature
Range: 40 to 260[degree]C. I.D.: 0.25mm. Length: 30m. Film Thickness:
0.5um. |
| Agilent 19091N-236 |
Agilent HP-INNOWax GC column Inner Diam.:
0.25 mm. Length: 60 m. Film Thickness 0.5 um. The order of polarity is as
follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn
are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases. |
| Agilent 19091N-577 |
Agilent Hp-Innowax, 20M, 0.18Mm, 0.18Um
|
| Agilent 19091P-K15 |
Agilent HP-PLOT Al2O3 "KCI" Deactivation GC
column Inner Diam.: 0.32 mm. Length: 50 m. Film Thickness: 8 um. The order of
polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns,
which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar
Phases:. |
| Agilent 19091P-K33 |
Agilent HP-PLOT Al2O3 "KCL" Deactivation GC
Column Inner Diam.: 0.25 mm. Length: 30 m. Film Thickness: 5 um. The order of
polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns,
which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar
Phases:. |
| Agilent 19091P-K33E |
Agilent GC Column, DB-200 30m, 0.53mm,
1.00um, 5in cage |
| Agilent 19091P-M15 |
Agilent HP-PLOT Al2O3 "M" Deactivation GC
column Inner Diam.: 0.32 mm. Length: 50 m. Film Thickness: 8 um. The order of
polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns,
which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar
Phases:. |
| Agilent 19091P-M15E |
Agilent GC Column, DB-624 60m, 0.53mm,
3.00um, 5in cage |
| Agilent 19091P-MS4 |
Agilent HP-PLOT Molesieve GC column Thin
Film:. Inner Diam.: 0.32 mm. Length: 30 m. Film Thickness: 12 um. Similar
Phases. W GS-Molesieve, CP Molesieve 5A, RT-Msieve 13X, Molsieve 5A-PLOT.
Maximum Temperature:. 350[degree]C. |
| Agilent 19091P-MS7 |
Agilent HP-PLOT Molesieve GC column Thick
Film:. Inner Diam.: 0.32 mm. Length: 15 m. Film Thickness: 25 um. Similar
Phases. W GS-Molesieve, CP Molesieve 5A, RT-Msieve 13X, Molsieve 5A-PLOT.
Maximum Temperature:. 350[degree]C. |
| Agilent 19091P-MS8 |
Agilent HP-PLOT Molecular Sieve 5A
Capillary GC Column Thick-film PLOT column for air monitoring applications and
analyzing noble gases. Resolve argon and oxygen at ambient temperatures. Phase
composition: 5A zeolite. Temperature Range: up to 350[degree]C. ID: 0.32mm.
Length: 30m. Film Thickness: 25um. |
| Agilent 19091P-QO3 |
Agilent HP-PLOT Q CP PoraPlot Q. Bonded
polystyrene-divinylbenzene based column. Separates ethane, ethlene, and ethyne
(acetylene). 0.32mm ID. Length: 1500mm. Film: 20um. Temperature Range: -60 to
270/290[degree]C. |
| Agilent 19091P-QO4 |
Agilent HP-PLOT Q CP PoraPlot Q. Bonded
polystyrene-divinylbenzene based column. Separates ethane, ethlene, and ethyne
(acetylene). 0.32mm ID. Length: 3000mm. Film: 20um. Temperature Range: -60 to
270/290[degree]C. |
| Agilent 19091P-QO4E |
Agilent HP-PLOT Q CP PoraPlot Q. Wound on
127mm cage. Bonded polystyrene-divinylbenzene based column. Separates ethane,
ethlene, and ethyne (acetylene). 0.32mm ID. Length: 3000mm. Film: 20um.
Temperature Range: -60 to 270/290[degree]C. |
| Agilent 19091P-S15 |
Agilent HP-PLOT Capillary GC Column Al2O3.
"S" column. For analysis of light hydrocarbons (C1 to C6) resolving
cyclopropane from propylene. Phase composition: Aluminum oxide. Temperature
range: up to 200[degree]C. ID: 0.32mm. Length: 50m. Film thickness: 8um. |
| Agilent 19091P-S15E |
Agilent HP-PLOT AI203 S
50m,0.32mm,8.0um,5in cage |
| Agilent 19091P-S33 |
Agilent HP-PLOT Al2O3 "S" Deactivation GC
column Inner Diam.: 0.25 mm. Length: 30 m. Film Thickness: 5 um. The order of
polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns,
which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar
Phases:. |
| Agilent 19091P-UO4 |
Agilent HP-PLOT U CP PoraPlot U. Bonded
divinylbenzene/ethylene glycol dimethacrylate. Column for C1 to C7
hydrocarbons, CO2, methane, air/CO, water, solvents, amines, alcohols, and
more. 0.32mm ID. Length: 3000mm. Film: 10um. Temperature Range: -60 to
190[degree]C. |
| Agilent 19091R-303 |
Agilent HP-VOC Environmental Capillary GC
Column Intermediate polarity column for the analysis of volatile organics.
Recommended for EPA Methods 502.2, 524.2, 601, 602, 8024, and 8260. Temperature
Range: -60 to 280[degree]C. ID: 0.20mm. Length: 30m. Film Thickness:
1.1um. |
| Agilent 19091R-306 |
Agilent HP-VOC Environmental Capillary GC
Column Intermediate polarity column for the analysis of volatile organics.
Recommended for EPA Methods 502.2, 524.2, 601, 602, 8024, and 8260. Temperature
Range: -60 to 280[degree]C. ID: 0.20mm. Length: 60m. Film Thickness:
1.1um. |
| Agilent 19091R-316 |
Agilent HP-VOC Environmental Capillary GC
Column Intermediate polarity column for the analysis of volatile organics.
Recommended for EPA Methods 502.2, 524.2, 601, 602, 8024, and 8260. Temperature
Range: -60 to 280[degree]C. ID: 0.32mm. Length: 60m. Film Thickness:
1.8um. |
| Agilent 19091R-319 |
Agilent HP-VOC Environmental Capillary GC
Column Intermediate polarity column for the analysis of volatile organics.
Recommended for EPA Methods 502.2, 524.2, 601, 602, 8024, and 8260. Temperature
Range: -60 to 280[degree]C. ID: 0.32mm. Length: 90m. Film Thickness:
1.8um. |
| Agilent 19091S-001 |
Agilent HP-PONA Petroleum Analyses
Capillary GC Column For the separation of paraffins, olefins, naphthenes,
aromatics. Tested to ensure resolution of m-xylene from p-xylene, and
cyclopentane from 2,3-dimethylbutane. Temperature Range: 60 to -325[degree]C.
ID: 0.20mm. Length: 50m. Film Thickness: 0.5um. |
| Agilent 19091S-001E |
Agilent HP-PONA Petroleum Analyses
Capillary GC Column On 127mm cage. For separation of paraffins, olefins,
naphthenes, aromatics. Tested to ensure resolution of m-xylene from p-xylene,
and cyclopentane from 2,3-dimethylbutane. Temperature Range: 60 to
-325[degree]C. ID: 0.20mm. Length: 50m. Film: 0.5um. |
| Agilent 19091S-004 |
Agilent HP-1/DHA
(5%)-diphenyl-(95%)-dimethylsiloxane, polydimethylsiloxane. 0.25mm ID. Length:
10,000mm. Film: 0.5um. Temperature Range: -60 to 325[degree]C. |
| Agilent 19091S-004E |
Agilent GC Column, ULTRA-2 50m, 0.32mm,
0.52um, 5in cage |
| Agilent 19091S-010 |
Agilent HP-PAS-5 GC column Inner Diam.:
0.32 mm. Length: 25 m. Film Thickness: 0.52 um um. HP-PAS-5 Temperature Range.
-60 to 325[degree]C. The 25 meter HP-PAS-5 and HP-PAS-1701 columns were
developed and are quality-controlled for dual-column confirmation of
organochlorine pesticides. |
| Agilent 19091S-101 |
Agilent HP-5MS GC column Inner Diam.: 0.20
mm. Length: 12 m. Film thickness: 0.33 um. Similar Phases:. Rtx-5MS, PTE-5.
Temperature Range isothermal/temperature programmed. -60 to
325/350[degree]C. |
| Agilent 19091S-102 |
Agilent HP-5MS GC Column Rtx-5MS, PTE-5.
(5%-phenyl)-methylpolysiloxane. Non-polar. Very low bleed characteristics.
Excellent inertness for active compounds. Bonded and cross-linked. Sovent
rinsable. 0.20mm. Length: 2500mm. Film: 0.33um. Temperature Range: -60 to
325/350[degree]C. |
| Agilent 19091S-102E |
Agilent HP-5MS GC Column Rtx-5MS, PTE-5.
Wound on 127mm cage. (5%-phenyl)-methylpolysiloxane. Non-polar. Very low bleed
characteristics. Excellent inertness for active compounds. Bonded and
cross-linked. Sovent rinsable. 0.20mm. Length: 2500mm. Film: 0.33um.
Temperature Range: -60 to 325/350[degree]C. |
| Agilent 19091S-105 |
Agilent HP-5MS GC column Inner Diam.: 0.20
mm. Length: 50 m. Film thickness: 0.33 um. Similar Phases:. Rtx-5MS, PTE-5.
Temperature Range isothermal/temperature programmed. -60 to
325/350[degree]C. |
| Agilent 19091S-112 |
Agilent HP-5MS GC column Inner Diam.: 0.25
mm. Length: 25 m. Film thickness: 0.52 um. Similar Phases:. Rtx-5MS, PTE-5.
Temperature Range isothermal/temperature programmed. -60 to
325/350[degree]C. |
| Agilent 19091S-112E |
Agilent GC Column, DB-1701 20m, 0.10mm,
0.40um, 5in cage |
| Agilent 19091S-113 |
Agilent HP-5MS GC column Inner Diam.: 0.25
mm. Length: 30 m. Film thickness: 0.50 um. Similar Phases:. Rtx-5MS, PTE-5.
Temperature Range isothermal/temperature programmed. -60 to
325/350[degree]C. |
| Agilent 19091S-133 |
Agilent HP-5MS GC column Inner Diam.: 0.25
mm. Length: 30m. Film thickness: 0.5um. Similar Phases:. Rtx-5MS, PTE-5.
Temperature Range isothermal/temperature programmed. -60 to
325/350[degree]C. |
| Agilent 19091S-139 |
Agilent HP-5MS, Semivolatile Test. 0.25mm.
Length: 3000mm. Film: 0.5um. Temperature Range: -60 to 325/350[degree]C. |
| Agilent 19091S-213 |
Agilent Environmental Standards HP-5MS,
30-m x 0.32 mm x 1.0 um column. Volatile Organic Compounds. Method 524.2. |
| Agilent 19091S-231 |
Agilent HP-5MS GC column Inner Diam.: 0.25
mm. Length: 15 m. Film thickness: 1.00 um. Similar Phases:. Rtx-5MS, PTE-5.
Temperature Range isothermal/temperature programmed. -60 to
325/350[degree]C. |
| Agilent 19091S-233 |
Agilent HP-5MS GC Column Rtx-5MS, PTE-5.
(5%-phenyl)-methylpolysiloxane. Non-polar. Very low bleed characteristics.
Excellent inertness for active compounds. Bonded and cross-linked. Sovent
rinsable. 0.25mm. Length: 3000mm. Film: 1um. Temperature Range: -60 to
325/350[degree]C. |
| Agilent 19091S-233E |
Agilent HP-5MS GC Column Rtx-5MS, PTE-5.
Wound on 127mm cage. (5%-phenyl)-methylpolysiloxane. Non-polar. Very low bleed
characteristics. Excellent inertness for active compounds. Bonded and
cross-linked. Sovent rinsable. 0.25mm. Length: 3000mm. Film: 1um. Temperature
Range: -60 to 325/350[degree]C. |
| Agilent 19091S-313 |
Agilent HP-5MS GC column Inner Diam.: 0.25
mm. Length: 30 m. Film thickness: 0.10 um. Similar Phases:. Rtx-5MS, PTE-5.
Temperature Range isothermal/temperature programmed. -60 to
325/350[degree]C. |
| Agilent 19091S-331 |
Agilent HP-5MS GC column Inner Diam.: 0.25
mm. Length: 15 m. Film thickness: 0.10 um. Similar Phases:. Rtx-5MS, PTE-5.
Temperature Range isothermal/temperature programmed. -60 to
325/350[degree]C. |
| Agilent 19091S-333 |
Agilent HP-5MS GC column Inner Diam.: 0.25
mm. Length: 30 m. Film thickness: 0.10 um. Similar Phases:. Rtx-5MS, PTE-5.
Temperature Range isothermal/temperature programmed. -60 to
325/350[degree]C. |
| Agilent 19091S-336 |
Agilent HP-5MS GC column Inner Diam.: 0.25
mm. Length: 60 m. Film thickness: 0.10 um. Similar Phases:. Rtx-5MS, PTE-5.
Temperature Range isothermal/temperature programmed. -60 to
325/350[degree]C. |
| Agilent 19091S-413 |
Agilent HP-5MS GC column Inner Diam.: 0.25
mm. Length: 30 m. Film thickness: 0.25 um. Similar Phases:. Rtx-5MS, PTE-5.
Temperature Range isothermal/temperature programmed. -60 to
325/350[degree]C. |
| Agilent 19091S-413E |
Agilent GC Column, GS-Q 30m, 0.32mm, 5in
cage |
| Agilent 19091S-416 |
Agilent HP-5MS GC column Inner Diam.: 0.25
mm. Length: 60 m. Film thickness: 0.25 um. Similar Phases:. Rtx-5MS, PTE-5.
Temperature Range isothermal/temperature programmed. -60 to
325/350[degree]C. |
| Agilent 19091S-431 |
Agilent HP-5MS GC column Inner Diam.: 0.25
mm. Length: 15 m. Film thickness: 0.25 um. Similar Phases:. Rtx-5MS, PTE-5.
Temperature Range isothermal/temperature programmed. -60 to
325/350[degree]C. |
| Agilent 19091S-433 |
Agilent HP-5MS Capillary GC Column For
GC/MS analysis of alkaloids, drugs, FAMEs, and halogenated compounds. Use for
EPA methods 525, 625, 8250, and 8270. Phase composition: bonded 5% phenyl, 95%
dimethylpolysiloxane. Range: -60 to 325/350[degree]C. ID: 0.25mm. Length: 30m.
Thickness: 0.25um. |
| Agilent 19091S-433E |
Agilent HP-5MS Capillary GC Column Wound on
127mm cage. For GC/MS analysis of alkaloids, drugs, FAMEs, and halogenated
compounds. Use for EPA methods 525, 625, 8250, and 8270. Composition: bonded 5%
phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. ID: 0.25mm.
Length: 30m. Film: 0.25um. |
| Agilent 19091S-433I |
Agilent HP-5msi 30m x 0.25mm ID, 0.25um for
acid and base analysis. (5% phenyl) methylpolysiloxane. |
| Agilent 19091S-436 |
Agilent HP-5MS GC column Inner Diam.: 0.25
mm. Length: 60 m. Film thickness: 0.25 um. Similar Phases:. Rtx-5MS, PTE-5.
Temperature Range isothermal/temperature programmed. -60 to
325/350[degree]C. |
| Agilent 19091S-436E |
Agilent GC Column, DB-WAXETR 60m, 0.32mm,
0.50um, 5in cage |
| Agilent 19091S-510 |
Agilent HP-Blood Alcohol Column Reliable
blood alcohol analysis. Excellent confirmation column with DB-ALC2 for method
using t-butanol as internal standard. ID: 0.32mm. Length: 750m. Thickness:
20um. Temperature Range: -60 to 325/350[degree]C. |
| Agilent 19091S-510E |
Agilent HP-Blood Alcohol Column Wound on
127mm cage. Reliable blood alcohol analysis. Excellent confirmation column with
DB-ALC2 for method using t-butanol as internal standard. ID: 0.32mm. Length:
750m. Thickness: 20um. Temperature Range: -60 to 325/350[degree]C. |
| Agilent 19091S-577 |
Agilent Hp-5Ms, 20M, 0.18Mm, 0.18Um |
| Agilent 19091S-602 |
Agilent HP-1MS GC column Inner Diam.: 0.20
mm. Length: 25 m. Film thickness: 0.33 um. Temperature Range
isothermal/temperature programmed. -60 to 325/350[degree]C. This phase is
identical to the HP-1 phase with respect to its chromatographic behavior, but
has ultra-low bleed specifications. |
| Agilent 19091S-602E |
Agilent GC Column, DB-1 25m, 0.25mm,
0.25um, 5in cage |
| Agilent 19091S-612 |
Agilent HP-1MS GC column Inner Diam.: 0.32
mm. Length: 25 m. Film thickness: 0.52 um. Temperature Range
isothermal/temperature programmed. -60 to 325/350[degree]C. This phase is
identical to the HP-1 phase with respect to its chromatographic behavior, but
has ultra-low bleed specifications. |
| Agilent 19091S-633 |
Agilent HP-1MS GC column Inner Diam.: 0.25
mm. Length: 30 m. Film thickness: 0.50 um. Temperature Range
isothermal/temperature programmed. -60 to 325/350[degree]C. This phase is
identical to the HP-1 phase with respect to its chromatographic behavior, but
has ultra-low bleed specifications. |
| Agilent 19091S-677 |
Agilent Hp-1Ms, 20M, 0.18Mm, 0.18Um |
| Agilent 19091S-713 |
Agilent Environmental Standards HP-1MS,
30-m x 0.32 mm x 1.0 um column. Organohalide Pesticide and PCBs. Method
505. |
| Agilent 19091S-733 |
Agilent HP-1MS GC column Inner Diam.: 0.25
mm. Length: 30 m. Film thickness: 1.00 um. Temperature Range
isothermal/temperature programmed. -60 to 325/350[degree]C. This phase is
identical to the HP-1 phase with respect to its chromatographic behavior, but
has ultra-low bleed specifications. |
| Agilent 19091S-733E |
Agilent GC Column, DB-5MS 30m, 0.25mm,
0.25um, 5in cage |
| Agilent 19091S-833 |
Agilent HP-1MS GC column Inner Diam.: 0.25
mm. Length: 30 m. Film thickness: 0.10 um. Temperature Range
isothermal/temperature programmed. -60 to 325/350[degree]C. This phase is
identical to the HP-1 phase with respect to its chromatographic behavior, but
has ultra-low bleed specifications. |
| Agilent 19091S-911 |
Agilent HP-1MS GC column Inner Diam.: 0.32
mm. Length: 15 m. Film thickness: 0.25 um. Temperature Range
isothermal/temperature programmed. -60 to 325/350[degree]C. This phase is
identical to the HP-1 phase with respect to its chromatographic behavior, but
has ultra-low bleed specifications. |
| Agilent 19091S-913 |
Agilent Environmental Standards HP-1MS,
30-m x 0.32 mm x 0.25 um column. 1,2-Dibromoethane/Chloropropane (EDB/DBCP).
Method 504. |
| Agilent 19091S-913E |
Agilent GC Column, GS-ALUMINA 30m, 0.53m,
5in cage |
| Agilent 19091S-916 |
Agilent HP-1MS GC column Inner Diam.: 0.32
mm. Length: 60 m. Film thickness: 0.25 um. Temperature Range
isothermal/temperature programmed. -60 to 325/350[degree]C. This phase is
identical to the HP-1 phase with respect to its chromatographic behavior, but
has ultra-low bleed specifications. |
| Agilent 19091S-931 |
Agilent HP-1MS GC column Inner Diam.: 0.25
mm. Length: 15 m. Film thickness: 0.25 um. Temperature Range
isothermal/temperature programmed. -60 to 325/350[degree]C. This phase is
identical to the HP-1 phase with respect to its chromatographic behavior, but
has ultra-low bleed specifications. |
| Agilent 19091S-931E |
Agilent GC Column, DB-WAX 15m, 0.53mm,
1.00um, 5in cage |
| Agilent 19091S-933 |
Agilent HP-1MS GC Column Rtx-1ms. 100%
Dimethylpolysiloxane. General purpose column with identical selectivity as
HP-1. Non-polar. Low bleed characteristics. Bonded and cross-linked. 0.25mm ID.
Length: 3000mm. Film: 0.25um. Temperature Range: -60 to 325/350[degree]C. |
| Agilent 19091S-933E |
Agilent HP-1MS GC Column Rtx-1ms. Wound on
127mm cage. 100% Dimethylpolysiloxane. General purpose column with identical
selectivity as HP-1. Non-polar. Low bleed characteristics. Bonded and
cross-linked. 0.25mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: -60
to 325/350[degree]C. |
| Agilent 19091S-936 |
Agilent HP-1MS GC column Inner Diam.: 0.25
mm. Length: 60 m. Film thickness: 0.25 um. Temperature Range
isothermal/temperature programmed. -60 to 325/350[degree]C. This phase is
identical to the HP-1 phase with respect to its chromatographic behavior, but
has ultra-low bleed specifications. |
| Agilent 19091S-936E |
Agilent HP-1MS GC Column Rtx-1ms. Wound on
127mm cage. 100% Dimethylpolysiloxane. General purpose column with identical
selectivity as HP-1. Non-polar. Low bleed characteristics. Bonded and
cross-linked. 0.25mm ID. Length: 6000mm. Film: 0.25um. Temperature Range: -60
to 325/350[degree]C. |
| Agilent 19091W-012 |
Agilent HP-20M Non-Bonded PEG Capillary GC
Column PEG column for the analysis of alcohols, glycols, essential oils,
ethers, solvents, and free acids. Phase composition: non-bonded polyethylene
glycol. Temperature Range: 60 to 220[degree]C. I.D.: 0.32mm. Length: 25m. Film
Thickness: 0.3um. |
| Agilent 19091W-012E |
Agilent GC Column, HP-5 25m, 0.32mm,
0.17um, 5in cage |
| Agilent 19091W-015 |
Agilent HP-20M Non-Bonded PEG Capillary GC
Column PEG column for the analysis of alcohols, glycols, essential oils,
ethers, solvents, and free acids. Phase composition: non-bonded polyethylene
glycol. Temperature Range: 60 to 220[degree]C. I.D.: 0.32mm. Length: 50m. Film
Thickness: 0.3um. |
| Agilent 19091W-015E |
Agilent GC Column, HP-5 50m, 0.32mm,
1.05um, 5in cage |
| Agilent 19091W-102 |
Agilent HP-20M Non-Bonded PEG Capillary GC
Column PEG column for the analysis of alcohols, glycols, essential oils,
ethers, solvents, and free acids. Phase composition: non-bonded polyethylene
glycol. Temperature Range: 60 to 220[degree]C. I.D.: 0.2mm. Length: 25m. Film
Thickness: 0.2um. |
| Agilent 19091W-105 |
Agilent HP-Classic Phase Capillary GC
column Inner Diam.: 0.20 mm. Length: 50 m. Film Thickness: 0.1 um. Similar
Phases. Carbowax 20M, 007CW, BP-20. Temperature Range:. 60 to 220 oC. HP
provides high-quality HP-20M nonbonded capillary columns to support established
methods. HP-20M: Carbowax 20M Phase. |
| Agilent 19091Y-012 |
Agilent HP-Classic Phase Capillary GC
column Inner Diam.: 0.32 mm. Length: 25 m. Film Thickness: 0.3 um. Similar
Phases. OV 101, SP 200. Temperature Range. 0 to 280[degree]C. HP continues to
provide high-quality HP-101 (methyl siloxane fluid) nonbonded capillary columns
to support established methods. |
| Agilent 19091Y-015 |
Agilent HP-Classic Phase Capillary GC
column Inner Diam.: 0.32 mm. Length: 50 m. Film Thickness: 0.3 um. Similar
Phases. OV 101, SP 200. Temperature Range. 0 to 280[degree]C. HP continues to
provide high-quality HP-101 (methyl siloxane fluid) nonbonded capillary columns
to support established methods. |
| Agilent 19091Y-101 |
Agilent HP-101 10m, 0.20mm, 0.20um |
| Agilent 19091Y-102 |
Agilent HP-Classic Phase Capillary GC
column Inner Diam.: 0.20 mm. Length: 25 m. Film Thickness: 0.2 um. Similar
Phases. OV 101, SP 200. Temperature Range. 0 to 280[degree]C. HP continues to
provide high-quality HP-101 (methyl siloxane fluid) nonbonded capillary columns
to support established methods. |
| Agilent 19091Z-002 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.20mm. Length: 25m. Film Thickness: 0.11um. |
| Agilent 19091Z-005 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.20mm. Length: 50m. Film Thickness: 0.11um. |
| Agilent 19091Z-008 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Phase composition: bonded 100% polydimethylsiloxane. I.D.:
0.20mm. Length: 17m. Film thickness: 0.11um. Temperature range: -60 to
325[degrees]C. |
| Agilent 19091Z-012 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.32mm. Length: 25m. Film Thickness: 0.17um. |
| Agilent 19091Z-012E |
Agilent GC Column |
| Agilent 19091Z-015 |
Agilent HP-1 GC column Inner Diam.: 0.25
mm. Length: 50 m. Film thickness: 0.17 um. Similar Phases:. DB-1, Rtx-1, OV-1,
SPB-1, SE-30, CP-Sil 5CB, RSL-150, MTX-1, BP-1, 007-1, MDN-1. Temperature Range
isothermal/temperature programmed:. -60 to 325/350[degree]C. -60 to
300/320[degree]C for 0.53 mm i.d. |
| Agilent 19091Z-102 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.20mm. Length: 25m. Film Thickness: 0.33um. |
| Agilent 19091Z-102E |
Agilent GC Column |
| Agilent 19091Z-105 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.20mm. Length: 50m. Film Thickness: 0.33um. |
| Agilent 19091Z-112 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.32mm. Length: 25m. Film Thickness: 0.52um. |
| Agilent 19091Z-112E |
Agilent GC Column |
| Agilent 19091Z-115 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.32mm. Length: 50m. Film Thickness: 0.52um. |
| Agilent 19091Z-115E |
Agilent HP-1 Capillary GC Column Wound on
127 cage. Nonpolar. For the analysis of amines, hydrocarbons, PCBs, pesticides,
phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature
Range: -60 to 325[degree]C. I.D.: 0.32mm. Length: 50m. Film Thickness:
0.52um. |
| Agilent 19091Z-202 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.20mm. Length: 25m. Film Thickness: 0.5um. |
| Agilent 19091Z-205 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.20mm. Length: 50m. Film Thickness: 0.5um. |
| Agilent 19091Z-211 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.32mm. Length: 15m. Film Thickness: 1.0um. |
| Agilent 19091Z-212 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.32mm. Length: 25m. Film Thickness: 1.05um. |
| Agilent 19091Z-213 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness: 1.0um. |
| Agilent 19091Z-213E |
Agilent HP-1 Capillary GC Column Wound on
127 cage. Nonpolar. For the analysis of amines, hydrocarbons, PCBs, pesticides,
phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature
Range: -60 to 325[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness:
1um. |
| Agilent 19091Z-215 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.32mm. Length: 50m. Film Thickness: 1.05um. |
| Agilent 19091Z-215E |
Agilent GC Column, DB-VRX 40m, 0.18mm, 1um,
5in cage |
| Agilent 19091Z-216 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.32mm. Length: 60m. Film Thickness: 1.0um. |
| Agilent 19091Z-216E |
Agilent HP-1 Capillary GC Column Wound on
127 cage. Nonpolar. For the analysis of amines, hydrocarbons, PCBs, pesticides,
phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature
Range: -60 to 325[degree]C. I.D.: 0.32mm. Length: 60m. Film Thickness:
1um. |
| Agilent 19091Z-231 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.25mm. Length: 15m. Film Thickness: 1.0um. |
| Agilent 19091Z-233 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.25mm. Length: 30m. Film Thickness: 1.0um. |
| Agilent 19091Z-233E |
Agilent HP-1 Capillary GC Column Wound on
127 cage. Nonpolar. For the analysis of amines, hydrocarbons, PCBs, pesticides,
phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature
Range: -60 to 325[degree]C. I.D.: 0.25mm. Length: 30m. Film Thickness:
1um. |
| Agilent 19091Z-236 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.25mm. Length: 60m. Film Thickness: 1.0um. |
| Agilent 19091Z-236E |
Agilent HP-1 Capillary GC Column Wound on
127 cage. Nonpolar. For the analysis of amines, hydrocarbons, PCBs, pesticides,
phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature
Range: -60 to 325[degree]C. I.D.: 0.25mm. Length: 60m. Film Thickness:
1um. |
| Agilent 19091Z-313 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness: 0.1um. |
| Agilent 19091Z-313E |
Agilent GC Column, HP-5, 30m, 0.32mm,
0.5um, 5in cage |
| Agilent 19091Z-331 |
Agilent HP-1 GC column Inner Diam.: 0.25
mm. Length: 15 m. Film thickness: 0.1 um. Similar Phases:. DB-1, Rtx-1, OV-1,
SPB-1, SE-30, CP-Sil 5CB, RSL-150, MTX-1, BP-1, 007-1, MDN-1. Temperature Range
isothermal/temperature programmed:. -60 to 325/350[degree]C. -60 to
300/320[degree]C for 0.53 mm i.d. |
| Agilent 19091Z-333 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.25mm. Length: 30m. Film Thickness: 0.1um. |
| Agilent 19091Z-411 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.32mm. Length: 15m. Film Thickness: 0.25um. |
| Agilent 19091Z-411E |
Agilent GC Column |
| Agilent 19091Z-413 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness: 0.25um. |
| Agilent 19091Z-413E |
Agilent HP-1 Capillary GC Column Wound on
127 cage. Nonpolar. For the analysis of amines, hydrocarbons, PCBs, pesticides,
phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature
Range: -60 to 325[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness:
0.25um. |
| Agilent 19091Z-416 |
Agilent HP-1 GC column Inner Diam.: 0.25
mm. Length: 60 m. Film thickness: 0.25 um. Similar Phases:. DB-1, Rtx-1, OV-1,
SPB-1, SE-30, CP-Sil 5CB, RSL-150, MTX-1, BP-1, 007-1, MDN-1. Temperature Range
isothermal/temperature programmed:. -60 to 325/350[degree]C. -60 to
300/320[degree]C for 0.53 mm i.d. |
| Agilent 19091Z-431 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.25mm. Length: 15m. Film Thickness: 0.25um. |
| Agilent 19091Z-431E |
Agilent GC Column, HP-1, 15m, 0.25mm,
0.25um, 5in cage |
| Agilent 19091Z-433 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.25mm. Length: 30m. Film Thickness: 0.25um. |
| Agilent 19091Z-433E |
Agilent HP-1 Capillary GC Column Wound on
127 cage. Nonpolar. For the analysis of amines, hydrocarbons, PCBs, pesticides,
phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature
Range: -60 to 325[degree]C. I.D.: 0.25mm. Length: 30m. Film Thickness:
0.25um. |
| Agilent 19091Z-436 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
325[degree]C. I.D.: 0.25mm. Length: 60m. Film Thickness: 0.25um. |
| Agilent 19091Z-513 |
Agilent HP-1 GC column Inner Diam.: 0.25
mm. Length: 30 m. Film thickness: 3.0 um. Similar Phases:. DB-1, Rtx-1, OV-1,
SPB-1, SE-30, CP-Sil 5CB, RSL-150, MTX-1, BP-1, 007-1, MDN-1. Temperature Range
isothermal/temperature programmed:. -60 to 325/350[degree]C. -60 to
300/320[degree]C for 0.53 mm i.d. |
| Agilent 19091Z-513E |
Agilent HP-1 Capillary GC Column Wound on
127 cage. Nonpolar. For the analysis of amines, hydrocarbons, PCBs, pesticides,
phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature
Range: -60 to 260[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness:
3um. |
| Agilent 19091Z-530 |
Agilent HP-1 MTBE Capillary GC Column A
nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides,
phenols and sulfur compounds, specifically MTBE and ethanol. Bonded 100%
polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.25mm.
Length: 100m. Film Thickness: 0.5um. |
| Agilent 19091Z-530E |
Agilent HP-1 Capillary GC Column Wound on
127 cage. Nonpolar. For the analysis of amines, hydrocarbons, PCBs, pesticides,
phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature
Range: -60 to 325[degree]C. I.D.: 0.25mm. Length: 100m. Film Thickness:
0.5um. |
| Agilent 19091Z-577 |
Agilent Hp-1, 20M, 0.18Mm, 0.18Um |
| Agilent 19091Z-613 |
Agilent HP-1 GC column Inner Diam.: 0.25
mm. Length: 30 m. Film thickness: 4.0 um. Similar Phases:. DB-1, Rtx-1, OV-1,
SPB-1, SE-30, CP-Sil 5CB, RSL-150, MTX-1, BP-1, 007-1, MDN-1. Temperature Range
isothermal/temperature programmed:. -60 to 325/350[degree]C. -60 to
300/320[degree]C for 0.53 mm i.d. |
| Agilent 19091Z-713 |
Agilent HP-1 GC column Inner Diam.: 0.25
mm. Length: 30 m. Film thickness: 5.0 um. Similar Phases:. DB-1, Rtx-1, OV-1,
SPB-1, SE-30, CP-Sil 5CB, RSL-150, MTX-1, BP-1, 007-1, MDN-1. Temperature Range
isothermal/temperature programmed:. -60 to 325/350[degree]C. -60 to
300/320[degree]C for 0.53 mm i.d. |
| Agilent 19091Z-713E |
Agilent HP-1 Capillary GC Column Wound on
127 cage. Nonpolar. For the analysis of amines, hydrocarbons, PCBs, pesticides,
phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature
Range: -60 to 260[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness:
5um. |
| Agilent 19091Z-716 |
Agilent HP-1 GC column Inner Diam.: 0.25
mm. Length: 60 m. Film thickness: 5.0 um. Similar Phases:. DB-1, Rtx-1, OV-1,
SPB-1, SE-30, CP-Sil 5CB, RSL-150, MTX-1, BP-1, 007-1, MDN-1. Temperature Range
isothermal/temperature programmed:. -60 to 325/350[degree]C. -60 to
300/320[degree]C for 0.53 mm i.d. |
| Agilent 19091Z-716E |
Agilent GC Column, DB-FFAP 60m, 0.25mm,
0.25um, 5in cage |
| Agilent 19095-10050 |
Agilent Fused silica MESI coated (thin)
Fused silica MESI coated (thin). |
| Agilent 19095-60510 |
Agilent HP 5880 Inlet Supplies Series 530
um Adapter Kit. Kit to adapt injection port for use with Series 530 um columns
kit. |
| Agilent 19095F-120 |
Agilent HP-FFAP GC column Inner Diam.: 0.53
mm. Length: 15 m. Film Thickness: 1.0 um. The order of polarity is as follows:
HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more
polar than, the HP-20M (Carbowax 20M) columns. Similar Phases. |
| Agilent 19095F-120E |
Agilent HP-FFAP Stabilwax-DA. Wound on
127mm cage. Nitroterephthalic acid modified polyethylene glycol. High polarity.
Designed for the analysis of volatile fatty acids and phenols. Bonded and
cross-linked. Solvent rinsable. 0.53mm ID. Length: 1500mm. Film: 1um.
Temperature Range: 60 to 240[degree]C. |
| Agilent 19095F-121 |
Agilent HP-FFAP PEG Capillary GC Column
Acid modified PEG column for analysis of acids, acrylates, alcohols, aldehydes,
ketones, nitriles, free-fatty acids. Phase composition: bonded polyethylene
glycol-TPA. Temperature Range: 60 to 230[degree]C. I.D.: 0.53mm. Length: 10m.
Film Thickness: 1.0um. |
| Agilent 19095F-123 |
Agilent HP-FFAP PEG Capillary GC Column
Acid modified PEG column for analysis of acids, acrylates, alcohols, aldehydes,
ketones, nitriles, free-fatty acids. Phase composition: bonded polyethylene
glycol-TPA. Temperature Range: 60 to 230[degree]C. I.D.: 0.53mm. Length: 30m.
Film Thickness: 1.0um. |
| Agilent 19095F-123E |
Agilent HP-FFAP Stabilwax-DA. Wound on
127mm cage. Nitroterephthalic acid modified polyethylene glycol. High polarity.
Designed for the analysis of volatile fatty acids and phenols. Bonded and
cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 1um.
Temperature Range: 60 to 240[degree]C. |
| Agilent 19095J-023 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 300/320[degree]C. I.D.
0.53mm. Length 30m. Thickness: 0.88um. |
| Agilent 19095J-023E |
Agilent HP5 Capillary GC Column Wound on
127mm cage. Nonpolar. For analysis of semivolatives, alkaloids, FAMEs,
pesticides, herbicides, halogenated compounds, unknown samples. Composition:
bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 300/320[degree]C.
I.D. 0.53mm. Length 30m. Film: 0.88um. |
| Agilent 19095J-121 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 300/320[degree]C. I.D.
0.53mm. Length 10m. Thickness: 2.65um. |
| Agilent 19095J-121E |
Agilent HP5 Capillary GC Column Wound on
127mm cage. Nonpolar. For analysis of semivolatives, alkaloids, FAMEs,
pesticides, herbicides, halogenated compounds, unknown samples. Composition:
bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 300/320[degree]C.
I.D. 0.53mm. Length 10m. Film: 2.65um. |
| Agilent 19095J-123 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 300/320[degree]C. I.D.
0.53mm. Length 30m. Thickness: 2.65um. |
| Agilent 19095J-123E |
Agilent HP5 Capillary GC Column Wound on
127mm cage. Nonpolar. For analysis of semivolatives, alkaloids, FAMEs,
pesticides, herbicides, halogenated compounds, unknown samples. Composition:
bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 300/320[degree]C.
I.D. 0.53mm. Length 30m. Film: 2.65um. |
| Agilent 19095J-321 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 300/320[degree]C. I.D.
0.53mm. Length 15m. Thickness: 1.5um. |
| Agilent 19095J-323 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 300/320[degree]C. I.D.
0.53mm. Length 30m. Thickness: 1.5um. |
| Agilent 19095J-323E |
Agilent HP5 Capillary GC Column Wound on
127mm cage. Nonpolar. For analysis of semivolatives, alkaloids, FAMEs,
pesticides, herbicides, halogenated compounds, unknown samples. Composition:
bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 300/320[degree]C.
I.D. 0.53mm. Length 30m. Film: 1.5um. |
| Agilent 19095J-621 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 300/320[degree]C. I.D.
0.53mm. Length 15m. Thickness: 5um. |
| Agilent 19095J-623 |
Agilent HP5 Capillary GC Column Nonpolar
column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides,
herbicides, halogenated compounds, unknown samples. Phase composition: bonded
5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 300/320[degree]C. I.D.
0.53mm. Length 30m. Thickness: 5um. |
| Agilent 19095J-623E |
Agilent GC Column, HP-88 30m, 0.25mm,
0.2um, 5in cage |
| Agilent 19095L-021 |
Agilent HP-50+ Capillary GC Column A medium
polarity column for the analysis of polar compounds such as basic drugs,
herbicides and chlorinated pesticides. Phase composition: bonded 50% phenyl,
50% dimethylsiloxane. Temperature Range: 40 to 280[degree]C. ID: 0.53mm.
Length: 15m. Film Thickness: 1.0um. |
| Agilent 19095L-023 |
Agilent HP-50+ Capillary GC Column A medium
polarity column for the analysis of basic polar compounds such as drugs,
herbicides and chlorinated pesticides. Phase composition: bonded 50% phenyl,
50% dimethylsiloxane. Temperature Range: 40 to 280[degree]C. ID: 0.53mm.
Length: 30m. Film Thickness: 1.0um. |
| Agilent 19095L-023E |
Agilent HP-50+ Capillary GC Column Wound on
127mm cage. Medium polarity. For analysis of basic polar compounds such as
drugs, herbicides and chlorinated pesticides. Phase composition: bonded 50%
phenyl, 50% dimethylsiloxane. Temperature Range: 40 to 280[degree]C. ID:
0.53mm. Length: 30m. Film: 1um. |
| Agilent 19095L-121 |
Agilent HP-17 Capillary GC Column An
intermediate polarity column designed for analysis of polar compounds such as
drugs, glycols, pesticides and steroids. Phase composition: non-bonded 50%
phenyl, 50% methylsiloxane. Temperature Range: 15 to 260[degree]C. ID: 0.53mm.
Length: 10m. Film Thickness: 2.0um. |
| Agilent 19095L-523 |
Agilent HP-50+ Capillary GC Column A medium
polarity column for the analysis of basic drugs, herbicides and chlorinated
pesticides. Phase composition: bonded 50% phenyl, 50% dimethylsiloxane.
Temperature Range: 40 to 280[degree]C. ID: 0.53mm. Length: 30m. Film Thickness:
0.5um. |
| Agilent 19095L-523E |
Agilent GC Column, CYCLODEX-B 30m, 0.32mm,
0.25um, 5in cage |
| Agilent 19095N-121 |
Agilent HP-INNOWax GC column Inner Diameter
0.53 mm. Length: 15 m. Film Thickness: 1.0 um. The order of polarity is as
follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn
are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases. |
| Agilent 19095N-121E |
Agilent HP-INNOWax GC Column Wound on 127mm
cage. HP-20M; SUPELCOWAX 10. Polyethylene glycol. High polarity. Column to
column repeatability. Bonded and cross-linked. Solvent rinsable. 0.53mm ID.
Length: 1500mm. Film: 1um. Temperature Range: 40 to 260/270[degree]C. |
| Agilent 19095N-123 |
Agilent HP-INNOWax PEG Capillary GC Column
PEG column for the analysis of alcohols, aromatics, essential oils, and free
acids. Phase composition: INNOphase* bondable polyethylene glycol. Temperature
Range: 40 to 240[degree]C. I.D.: 0.53mm. Length: 30m. Film Thickness:
1.0um. |
| Agilent 19095N-123E |
Agilent HP-INNOWax GC Column Wound on 127mm
cage. HP-20M; SUPELCOWAX 10. Polyethylene glycol. High polarity. Column to
column repeatability. Bonded and cross-linked. Solvent rinsable. 0.53mm ID.
Length: 3000mm. Film: 1um. Temperature Range: 40 to 260/270[degree]C. |
| Agilent 19095N-126 |
Agilent HP-INNOWax PEG Capillary GC Column
PEG column for the analysis of alcohols, aromatics, essential oils, and free
acids. Phase composition: INNOphase* bondable polyethylene glycol. Temperature
Range: 40 to 240[degree]C. I.D.: 0.53mm. Length: 60m. Film Thickness:
1.0um. |
| Agilent 19095P-K23 |
Agilent HP-PLOT Al2O3 "KCI" Deactivation GC
column Inner Diam.: 0.53 mm. Length: 30 m. Film Thickness: 15 um. The order of
polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns,
which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar
Phases:. |
| Agilent 19095P-K25 |
Agilent HP-PLOT Al2O3 "KCI" Deactivation GC
column Inner Diam.: 0.53 mm. Length: 50 m. Film Thickness: 15 um. The order of
polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns,
which in turn are more polar than, the HP-20M (Carbowax 20M) columns.1. Similar
Phases:. |
| Agilent 19095P-M23 |
Agilent HP-PLOT Al2O3 "M" Capillary GC
Column PLOT (porous layer open tubular) column designed for the analysis of
light hydrocarbons (C1 to C6), resolving cyclopropane from propylene. Phase
composition: Aluminum oxide. Temperature Range: up to 200[degree]C. ID: 0.53mm.
Length: 30m. Film Thickness: 15um. |
| Agilent 19095P-M25 |
Agilent HP-PLOT Al2O3 "M" Deactivation GC
column Inner Diam.: 0.53 mm. Length: 50 m. Film Thickness: 15 um. The order of
polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns,
which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar
Phases:. |
| Agilent 19095P-M25E |
Agilent GC Column, DB-17MS 60m, 0.25mm,
0.25um, 5in cage |
| Agilent 19095P-MS0 |
Agilent HP-PLOT Molecular Sieve 5A
Capillary GC Column Thick-film PLOT column for air monitoring applications and
analyzing noble gases. Resolve argon and oxygen at ambient temperatures. Phase
composition: 5A zeolite. Temperature Range: up to 350[degree]C. I.D.: 0.53mm.
Length: 30m. Film Thickness: 50um. |
| Agilent 19095P-MS0E |
Agilent HP-PLOT Molecular Sieve 5A
Capillary GC Column Wound on 127mm cage. Thick-film PLOT. For air monitoring
applications and analyzing noble gases. Resolve argon and oxygen at ambient
temperatures. Composition: 5A zeolite. Temperature Range: up to 350[degree]C.
I.D.: 0.53mm. Length: 30m. Film: 50um. |
| Agilent 19095P-MS5 |
Agilent HP-PLOT Molecular Sieve 5A
Capillary GC Column Thin-film PLOT column for air monitoring applications and
analyzing noble gases. Resolve argon and oxygen at subambient temperatures.
Phase composition: 5A zeolite. Temperature Range: up to 350[degree]C. I.D.:
0.53mm. Length: 15m. Film Thickness: 25um. |
| Agilent 19095P-MS6 |
Agilent HP-PLOT Molecular Sieve 5A
Capillary GC Column Thin-film PLOT column for air monitoring applications and
analyzing noble gases. Resolve argon and oxygen at subambient temperatures.
Phase composition: 5A zeolite. Temperature Range: up to 350[degree]C. I.D.:
0.53mm. Length: 30m. Film Thickness: 25um. |
| Agilent 19095P-MS9 |
Agilent HP-PLOT Molecular Sieve 5A
Capillary GC Column Thick-film PLOT column for air monitoring applications and
analyzing noble gases. Resolve argon and oxygen at ambient temperatures. Phase
composition: 5A zeolite. Temperature Range: up to 350[degree]C. I.D.: 0.53mm.
Length: 15m. Film Thickness: 50um. |
| Agilent 19095P-QO3 |
Agilent HP-PLOT Q GC column Inner Diam.:
0.53 mm. Length: 15 m. Film Thickness: 40 um. Based on a
polystyrene-divinylbenzene (DVB) stationary phase the new HP-PLOT Q columns
stand out through their capability of separating all C1 to C3 hydrocarbon
isomers at 60[degree]C. |
| Agilent 19095P-QO3E |
Agilent HP-PLOT Q CP PoraPlot Q. Wound on
127mm cage. Bonded polystyrene-divinylbenzene based column. Separates ethane,
ethlene, and ethyne (acetylene). 0.53mm ID. Length: 1500mm. Film: 40um.
Temperature Range: -60 to 270/290[degree]C. |
| Agilent 19095P-QO4 |
Agilent HP-PLOT Q GC column Inner Diam.:
0.53 mm. Length: 30 m. Film Thickness: 40 um. Based on a
polystyrene-divinylbenzene (DVB) stationary phase the new HP-PLOT Q columns
stand out through their capability of separating all C1 to C3 hydrocarbon
isomers at 60[degree]C. |
| Agilent 19095P-QO4E |
Agilent GC Column |
| Agilent 19095P-S21 |
Agilent HP-PLOT Al2O3 "S" Deactivation GC
column Inner Diam.: 0.53 mm. Length: 15 m. Film Thickness: 15 um. The order of
polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns,
which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar
Phases:. |
| Agilent 19095P-S23 |
Agilent HP-PLOT Al2O3 "S" Deactivation GC
column Inner Diam.: 0.53 mm. Length: 30 m. Film Thickness: 15 um. The order of
polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns,
which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar
Phases:. |
| Agilent 19095P-S25 |
Agilent HP-PLOT Al2O3 "S" Deactivation GC
column Inner Diam.: 0.53 mm. Length: 50 m. Film Thickness: 15 um. The order of
polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns,
which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar
Phases:. |
| Agilent 19095P-S25E |
Agilent HP-PLOT AI2O3-S Wound on 127mm
cage. Middle range of polarity for alumina phases. General purpose column for
light hydrocarbon analysis. Best for resolving acetylene from butane and
propylene from isobutane. 0.53mm ID. Length: 5000mm. Film: 15um. Temperature
Range: -60 to 200[degree]C. |
| Agilent 19095P-UO3 |
Agilent HP-PLOT U CP PoraPlot U. Bonded
divinylbenzene/ethylene glycol dimethacrylate. Column for C1 to C7
hydrocarbons, CO2, methane, air/CO, water, solvents, amines, alcohols, and
more. 0.53mm ID. Length: 1500mm. Film: 20um. Temperature Range: -60 to
190[degree]C. |
| Agilent 19095P-UO4 |
Agilent HP-PLOT U CP PoraPlot U. Bonded
divinylbenzene/ethylene glycol dimethacrylate. Column for C1 to C7
hydrocarbons, CO2, methane, air/CO, water, solvents, amines, alcohols, and
more. 0.53mm ID. Length: 3000mm. Film: 20um. Temperature Range: -60 to
190[degree]C. |
| Agilent 19095P-UO4E |
Agilent HP-PLOT U CP PoraPlot U. Wound on
127mm cage. Bonded divinylbenzene/ethylene glycol dimethacrylate. Column for C1
to C7 hydrocarbons, CO2, methane, air/CO, water, solvents, amines, alcohols,
and more. 0.53mm ID. Length: 3000mm. Film: 20um. Temperature Range: -60 to
190[degree]C. |
| Agilent 19095R-420 |
Agilent HP-VOC Environmental Capillary GC
Column Intermediate polarity column for the analysis of volatile organics.
Recommended for EPA Methods 502.2, 524.2, 601, 602, 8024, and 8260. Temperature
Range: -60 to 280[degree]C. ID: 0.53mm. Length: 105m. Film Thickness:
3.0um. |
| Agilent 19095R-429 |
Agilent HP-VOC GC column Inner Diam.: 0.53
mm. Length: 90 m. Film Thickness: 3.0 um. Similar Phases. Rtx-502.2, DB-502.2,
Rtx-Volatiles, Supelco VOCOL. Temperature Range. -60 to 280[degree]C. Developed
to meet the challenges of EPA Method 502. |
| Agilent 19095S-100 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
300[degree]C. I.D.: 0.53mm. Length: 5m. Film Thickness: 2.65um. |
| Agilent 19095S-100E |
Agilent HP-1 Capillary GC Column Wound on
127mm cage. A nonpolar column for the analysis of amines, hydrocarbons, PCBs,
pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane.
Temperature Range: -60 to 300[degree]C. I.D.: 0.53mm. Length: 5m. Film
Thickness: 2.65um. |
| Agilent 19095S-200 |
Agilent |
| Agilent 19095V-420E |
Agilent HP-Fast Residual Solvent Column
Wound on 127mm cage. Bonded and cross-linked. 0.53mm ID. Length: 3000mm. Film:
1um. Temperature Range: -20 to 260[degree]C. |
| Agilent 19095W-121 |
Agilent HP-20M Non-Bonded PEG Capillary GC
Column PEG column for the analysis of alcohols, glycols, essential oils,
ethers, solvents, and free acids. Phase composition: non-bonded polyethylene
glycol. Temperature Range: 60 to 220[degree]C. I.D.: 0.53m. Length: 10m. Film
Thickness: 1.33um. |
| Agilent 19095W-123 |
Agilent HP-20M Non-Bonded PEG Capillary GC
Column PEG column for the analysis of alcohols, glycols, essential oils,
ethers, solvents, and free acids. Phase composition: non-bonded polyethylene
glycol. Temperature Range: 60 to 220[degree]C. I.D.: 0.53m. Length: 30m. Film
Thickness: 1.33um. |
| Agilent 19095Z-020 |
Agilent HP-1 GC column Inner Diam.: 0.53
mm. Length: 5 m. Film thickness: 0.88 um. These columns are coated with high
temperature polyimide, allowing temperature programmed operation up to
400[degree]C. The lifetime of the column at 400[degree]C is about 50 hours.
Similar Phases:. |
| Agilent 19095Z-021 |
Agilent HP-1 GC column Inner Diam.: 0.53
mm. Length: 10 m. Film thickness: 0.88 um. Similar Phases:. DB-1, Rtx-1, OV-1,
SPB-1, SE-30, CP-Sil 5CB, RSL-150, MTX-1, BP-1, 007-1, MDN-1. Temperature Range
isothermal/temperature programmed:. -60 to 325/350[degree]C. -60 to
300/320[degree]C for 0.53 mm i.d. |
| Agilent 19095Z-021E |
Agilent GC Column, HP-1 10m, 0.53mm,
0.88um, 5in cage |
| Agilent 19095Z-023 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
300[degree]C. I.D.: 0.53mm. Length: 30m. Film Thickness: 0.88um. |
| Agilent 19095Z-023E |
Agilent GC Column, HP-5 30m, 0.53mm, 5.0um,
5in cage |
| Agilent 19095Z-121 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
300[degree]C. I.D.: 0.53mm. Length: 10m. Film Thickness: 2.65um. |
| Agilent 19095Z-121E |
Agilent HP-1 Capillary GC Column Wound on
127mm cage. Nonpolar column for the analysis of amines, hydrocarbons, PCBs,
pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane.
Temperature Range: -60 to 300[degree]C. I.D.: 0.53mm. Length: 10m. Film
Thickness: 2.65um. |
| Agilent 19095Z-123 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
300[degree]C. I.D.: 0.53mm. Length: 30m. Film Thickness: 2.65um. |
| Agilent 19095Z-123E |
Agilent HP-1 Capillary GC Column Wound on
127mm cage. A nonpolar column for the analysis of amines, hydrocarbons, PCBs,
pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane.
Temperature Range: -60 to 300[degree]C. I.D.: 0.53mm. Length: 30m. Film
Thickness: 2.65um. |
| Agilent 19095Z-220 |
Agilent HP-1 GC column Inner Diam.: 0.53
mm. Length: 5 m. Film thickness: 0.15 um. These columns are coated with high
temperature polyimide, allowing temperature programmed operation up to
400[degree]C. The lifetime of the column at 400[degree]C is about 50 hours.
Similar Phases:. |
| Agilent 19095Z-221 |
Agilent Extended SIMDIST Petroleum Analyses
Capillary GC Column For extended simulated distillations of heavy petroleums
and waxes. Temperature Range: up to 400[degree]C. I.D.: 0.53mm. Length: 15m.
Film Thickness: 0.15um. |
| Agilent 19095Z-221E |
Agilent Extended SIMDIST Petroleum Analyses
Capillary GC Column Wound on 127mm cage. For extended simulated distillations
of heavy petroleums and waxes. Temperature Range: up to 400[degree]C. I.D.:
0.53mm. Length: 15m. Film Thickness: 0.15um. |
| Agilent 19095Z-321 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
300[degree]C. I.D.: 0.53mm. Length: 15m. Film Thickness: 1.5um. |
| Agilent 19095Z-321E |
Agilent GC Column, HP-5, 15m, 0.32mm,
0.25um, 5in cage |
| Agilent 19095Z-323 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
300[degree]C. I.D.: 0.53mm. Length: 30m. Film Thickness: 1.5um. |
| Agilent 19095Z-323E |
Agilent HP-1 Capillary GC Column Wound on
127mm cage. A nonpolar column for the analysis of amines, hydrocarbons, PCBs,
pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane.
Temperature Range: -60 to 300[degree]C. I.D.: 0.53mm. Length: 30m. Film
Thickness: 1.5um. |
| Agilent 19095Z-421 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
300[degree]C. I.D.: 0.53mm. Length: 15m. Film Thickness: 3.0um. |
| Agilent 19095Z-421E |
Agilent HP-1 Capillary GC Column Wound on
127mm cage. A nonpolar column for the analysis of amines, hydrocarbons, PCBs,
pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane.
Temperature Range: -60 to 300[degree]C. I.D.: 0.53mm. Length: 15m. Film
Thickness: 3.0um. |
| Agilent 19095Z-423 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
300[degree]C. I.D.: 0.53mm. Length: 30m. Film Thickness: 3.0um. |
| Agilent 19095Z-423E |
Agilent GC Column |
| Agilent 19095Z-621 |
Agilent HP-1 GC column Inner Diam.: 0.53
mm. Length: 15 m. Film thickness: 5.0 um. Similar Phases:. DB-1, Rtx-1, OV-1,
SPB-1, SE-30, CP-Sil 5CB, RSL-150, MTX-1, BP-1, 007-1, MDN-1. Temperature Range
isothermal/temperature programmed:. -60 to 325/350[degree]C. -60 to
300/320[degree]C for 0.53 mm i.d. |
| Agilent 19095Z-623 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
300[degree]C. I.D.: 0.53mm. Length: 30m. Film Thickness: 5.0um. |
| Agilent 19095Z-626 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
300[degree]C. I.D.: 0.53mm. Length: 60m. Film Thickness: 5.0um. |
| Agilent 19095Z-627 |
Agilent HP-1 Capillary GC Column A nonpolar
column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and
sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to
300[degree]C. I.D.: 0.53mm. Length: 7.5m. Film Thickness: 5.0um. |
| Agilent 19095Z-627E |
Agilent GC Column, HP-1 7.5m, 0.53mm,
5.0um, 5in cage |
| Agilent 1909BD-113 |
Agilent Biodiesel EN14103 FAME Analysis 30m
x 0.32mm x 0.25um |
| Agilent 19199M |
Agilent GC Instrument Supplies Installation
Kit for HP 5890 without Gas Purifier System. Includes. |
| Agilent 19199N |
Agilent GC Instrument Supplies Installation
Kit for HP 5890 with Gas Purifier System. 1/8 in. fittings. Glass indicating
oxygen trap, preconditioned moisture trap, hydrocarbon trap, He/H2 combination
gas purifier and items listed under kit HP 5890. |
| Agilent 19231-20910 |
Agilent HP 5890 Detector Supplies FID
Supplies. Ignitor castle. |
| Agilent 19231-20940 |
Agilent HP 5890 Detector Supplies FID
Supplies. Collector nut. |
| Agilent 19231-20950 |
Agilent HP 5890 Detector Supplies FID
Supplies. Lower collector insulator. |
| Agilent 19231-20960 |
Agilent HP 5890 Detector Supplies FID
Supplies. Collector body. |
| Agilent 19231-20970 |
Agilent HP 5890 Detector Supplies FID
Supplies. Upper collector insulator. |
| Agilent 19231-21050 |
Agilent HP 5890 Detector Supplies FID
Supplies. PTFE chimney (optional). |
| Agilent 19231-21060 |
Agilent HP 5890 Detector Supplies FID
Supplies. Optional hastelloy castle. |
| Agilent 19231-21080 |
Agilent HP 5890 Detector Supplies FID
Supplies. Optional hastelloy collector. |
| Agilent 19231-60680 |
Agilent HP 5890 Detector Supplies FID
Supplies. Ignitor (glow plug) assembly. |
| Agilent 19231-60690 |
Agilent HP 5890 Detector Supplies FID
Supplies. Collector assembly: (contains items 2-10). |
| Agilent 19231-60790 |
Agilent Chemical Filters/Traps Detector
trap replacement kit. |
| Agilent 19231-80520 |
Agilent HP 5890 Detector Supplies FID and
NPD Adapters. FID/NPD 1/8 in. packed column. |
| Agilent 19231-80530 |
Agilent HP 5890 Detector Supplies FID and
NPD Adapters. FID/NPD 1/4 in. packed column. |
| Agilent 19231-80590 |
Agilent Chemical Filters/Traps Replacement
detector stainless steel trap. |
| Agilent 19232-60676 |
Agilent HP 5890 Detector Supplies TCD
replacement cartridge. |
| Agilent 19232-80550 |
Agilent HP 5890 Detector Supplies Makeup
gas adapter, TCD. |
| Agilent 19233-20625 |
Agilent HP 5890 Detector Supplies Electron
Capture Detector. ECD fused silica liner (new style). |
| Agilent 19233-20755 |
Agilent HP 5890 Detector Supplies Electron
Capture Detector. Stainless steel cap for ECD makeup gas adapter (new style and
micro ECD). |
| Agilent 19233-80565 |
Agilent HP 5890 Detector Supplies Electron
Capture Detector. Makeup gas adapter, ECD, new style. |
| Agilent 19234-60540 |
Agilent HP 5890 Detector Supplies NPD
Supplies. NPD collector (NPD bead). |
| Agilent 19234-60720 |
Agilent HP 5890 Detector Supplies FID
Supplies. Detector nut warmer. |
| Agilent 19243-00070 |
Agilent HP 5890 Split/Splitless Multimode
Inlet Split/Splitless Inlet Parts. Lower insulation cover. |
| Agilent 19243-60500 |
Agilent Headspace Septum Nut Universal
packed column inlet (non-purged) supplies. Non EPC. For non-purged packed
inlets. |
| Agilent 19243-60505 |
Agilent HP 5890 Packed Column Inlet
Supplies Universal Packed Column Inlet (non-purged). Septum retainer nut. |
| Agilent 19243-60570 |
Agilent HP 5890 Packed Column Inlet
Supplies Septum-Purged Packed Column Inlet. Nonpurging septum nut assembly for
manual flow control only, not EPC. |
| Agilent 19243-80510 |
Agilent HP 5880 Inlet Supplies
Liner/adapter for using other column types in the 1/4 in. port. 1/8 in. metal
columns. |
| Agilent 19243-80520 |
Agilent HP 5890 Packed Column Inlet
Supplies Septum-Purged Packed Column Inlet. Adapters without glass liners: 1/4
in. column adapter. |
| Agilent 19243-80530 |
Agilent HP 5890 Packed Column Inlet
Supplies Septum-Purged Packed Column Inlet. Adapter with glass liners: 1/8 in.
column adapter. |
| Agilent 19243-80540 |
Agilent HP 5890 Packed Column Inlet
Supplies Septum-Purged Packed Column Inlet. Adapter with glass liners: 1/4 in.
column adapter. |
| Agilent 19243-80550 |
Agilent Jumper, weldment Jumper,
weldment. |
| Agilent 19243-80570 |
Agilent HP 5890 Packed Column Inlet
Supplies Septum-Purged Packed Column Inlet. Top insert weldment. |
| Agilent 19244-80540 |
Agilent HP 5880 Inlet Supplies Series 530
um Adapter Kit. Injection port liner for 530 um column. |
| Agilent 19244-80560 |
Agilent HP 5890 Detector Supplies Jets.
Capillary/Series 530 um Jet, adaptable capillary (0.29mm ID tip). |
| Agilent 19244-80610 |
Agilent HP 5890 Detector Supplies FID and
NPD Adapters. FID/NPD capillary column. |
| Agilent 19244-80620 |
Agilent HP 5890 Detector Supplies Jets.
High-temperature jet (for simulated distillation). |
| Agilent 19245-20510 |
Agilent HP 5890 Cool On-Column (COC) Inlets
Manual Injection. Inserts for capillary columns: For 200 um columns (1 silver
ring). |
| Agilent 19245-20515 |
Agilent VWR* Critical Cover* GenPro* Cover
General purpose light weight round cover with elastic for product protection in
critical environments. 91.4 x 91.4 cm. |
| Agilent 19245-20525 |
Agilent HP 5890 Cool On-Column (COC) Inlets
Manual Injection. Inserts for capillary columns: For 320 um columns (5 silver
rings). |
| Agilent 19245-20580 |
Agilent HP 5890 Cool On-Column (COC) Inlets
Manual Injection. Inserts for capillary columns: For 530 um columns (no
rings). |
| Agilent 19245-20670 |
Agilent HP 5890 Cool On-Column (COC) Inlets
Automatic Injection. Needle guide (for HP 7673A only). First automatic direct
cool on-column injection into 320 um and 250 um diameter columns. |
| Agilent 19245-20780 |
Agilent HP 5890 Cool On-Column (COC) Inlets
Manual Injection. Inserts for capillary columns: For 530 um Al clad columns (4
rings). |
| Agilent 19245-40050 |
Agilent HP 5890 Cool On-Column (COC) Inlets
Manual Injection. Duckbill. |
| Agilent 19245-60760 |
Agilent HP 5890 Cool On-Column (COC) Inlets
Manual Injection. Spring: For HP 5890 Series II GC. |
| Agilent 19245-80520 |
Agilent HP 5890 Cool On-Column (COC) Inlets
Automatic Injection. Septum nut (HP 5890 Series II GC). First automatic direct
cool on-column injection into 320 um and 250 um diameter columns. |
| Agilent 19246-60526 |
Agilent Pressure Gauge For Agilent
6890/5890 Regulators, Mass Flow Controllers, and Restrictors. 0-15psig
(0-100kPa). |
| Agilent 19246-60550 |
Agilent Pressure regulator 0-100 psi
Pressure regulator 0-100 psi. |
| Agilent 19246-60560 |
Agilent Back pressure regulator, 0-15 psi
Back pressure regulator, 0-15 psi. |
| Agilent 19246-60570 |
Agilent Back pressure regulator, 0-30 psi
Back pressure regulator, 0-30 psi. |
| Agilent 19246-60580 |
Agilent Back pressure regulator, 0-60 psi
Back pressure regulator, 0-60 psi. |
| Agilent 19246-60620 |
Agilent Back pressure regulator w/gauge,
0-15 psi Back pressure regulator w/gauge, 0-15 psi. |
| Agilent 19246-60630 |
Agilent Back pressure regulator w/gauge,
0-60 psi Back pressure regulator w/gauge, 0-60 psi. |
| Agilent 19246-60690 |
Agilent Back pressure regulator, 0-100 psi
Back pressure regulator, 0-100 psi. |
| Agilent 19251-00100 |
Agilent Angled Wrench For split/splitless
septum nut and weldment. |
| Agilent 19251-20620 |
Agilent HP 5890 Split/Splitless Multimode
Inlet Split/Splitless Inlet Parts. Retaining nut. |
| Agilent 19251-60540 |
Agilent Split/Splitless Liner for Capillary
Inlet Systems 4mm ID. Volume: 990uL. For labile sampling and wide boiling
ranges. Borosilicate glass. 10gm silanized glass wool packing. |
| Agilent 19251-60575 |
Agilent HP 5890 Split/Splitless Multimode
Inlet Split/Splitless Inlet Parts. Split/splitless insert weldment with
tubing. |
| Agilent 19251-60700 |
Agilent Thermal upgrade kit Use to enhance
the performace of pre 1991 5890s with split inlets. |
| Agilent 19251-80680 |
Agilent HP Deactivated Retention Gaps and
Column Accessories Column ferrule installation tool. Using an HP proprietary
deactivation process, we are manufacturing retention gaps that will not degrade
the performance of your chromatographic column. |
| Agilent 19251C |
Agilent Split vent trap 5890 GC
(internal). |
| Agilent 19256-60500 |
Agilent HP 5890 Detector Supplies FPD
Supplies. Start-up kit. |
| Agilent 19256-60590 |
Agilent HP 5890 Detector Supplies FPD
Supplies. Liner/ferrule kit. |
| Agilent 19256-80000 |
Agilent HP 5890 Detector Supplies FPD
Supplies. Sulfur filter. |
| Agilent 19256-80010 |
Agilent HP 5890 Detector Supplies FPD
Supplies. Phosphorus filter. |
| Agilent 19256-80030 |
Agilent HP 5890 Detector Supplies FPD
Supplies. Window, heat shield, 1st. |
| Agilent 19256-80060 |
Agilent HP 5890 Detector Supplies FPD
Supplies. Window, heat shield, 2nd. |
| Agilent 19256-80570 |
Agilent HP 5890 Detector Supplies FPD
Supplies. Adapter weldment, capillary. |
| Agilent 19256-80590 |
Agilent HP 5890 Detector Supplies FPD
Supplies. Adapter weldment, 1/8 in. columns. |
| Agilent 19258-20830 |
Agilent HP 7694 Headspace Analysis Supplies
Transfer line nut. |
| Agilent 19258-20870 |
Agilent HP 7694 Headspace Analysis Supplies
Transfer line ferrule. |
| Agilent 1925820920 |
Agilent |
| Agilent 19298-60500 |
Agilent MIDI System Calibration Standard
Miscellaneous Qualitative Standards. Quantitative calibration standard for the
Microbial ID System. Fatty acid methyl esters w/v%. 0.01% n-C9:0, 0.02%
n-C10:0, 0.01% n-C11:0, 0.02% C12.0, 0.01% C13:0, 0.02% C14:0, 0.01% n-C15:0,
0.02% n-C16:0, 0.01% n-C17:0, 0. |
| Agilent 19301-00150 |
Agilent Special Instrument Tools Septum Nut
Wrenches. FID retainer nut wrench (HP 5880, 5890, 6890). |
| Agilent 19301-20720 |
Agilent HP 6890 Detector Supplies FID
Consumables. Detector cleaning wire. |
| Agilent 19301-60660 |
Agilent HP 5880 Detector Supplies Flame
Ionization Detector (FID). FID flow measuring insert. |
| Agilent 19301-80530 |
Agilent HP 5890 Detector Supplies Electron
Capture Detector. ECD column adapter, 1/4 to 1/8 in. metal. |
| Agilent 19302-80020 |
Agilent HP 5890 Detector Supplies TCD
column adapter, 1/8 to 1/4 in. glass. |
| Agilent 19305-60580 |
Agilent HP 5880 Detector Supplies Flame
Photometric Detector (FPD). Performance evaluation sample, FPD. |
| Agilent 19320-60656 |
Agilent Pressure gauge, 0-30psi Pressure
gauge, 0-30psi. |
| Agilent 19320-80625 |
Agilent HP 5890 Cool On-Column (COC) Inlets
Manual Injection. Cooling tower assembly. |
| Agilent 19325-60660 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 Valve-Related Parts. Air actuator. |
| Agilent 19350-60540 |
Agilent HP 5880 Inlet Supplies General
Supplies for the HP 5880A GC. Replacement thermal printhead for HP 5880A and HP
3388A terminals. |
| Agilent 19354-60510 |
Agilent Qualitative Standards Miscellaneous
Qualitative Standards. Nickel Catalyst. Mixture of 10+/-5 ppm each of methane,
carbon monoxide, and carbon dioxide in helium. One pressurized container (370
ml at 25 psig). |
| Agilent 19361-60566 |
Agilent Pressure gauge, 0-100psi Pressure
gauge, 0-100psi. |
| Agilent 19361-80120 |
Agilent Jumper tube 360mm for TCD Jumper
tube 360mm for TCD. |
| Agilent 19362-60510 |
Agilent MFC Restrictor 0-20 ml/min, old
style Red color code, silver color dot. |
| Agilent 19362-60515 |
Agilent MFC Restrictor 0-20 ml/min Red and
purple color dot code. |
| Agilent 19362-60520 |
Agilent MFC Restrictor 0-60 ml/min, old
style Red color code. |
| Agilent 19362-60525 |
Agilent MFC Restrictor 0-60 ml/min Blue and
purple color dot code. |
| Agilent 19362-60530 |
Agilent MFC Restrictor 0-110 ml/min, old
style Green color code. |
| Agilent 19362-60535 |
Agilent MFC Restrictor 0-110 ml/min Green
and purple color dot code. |
| Agilent 19362-60540 |
Agilent MFC Restrictor 0-400 ml/min, old
style Black color code. |
| Agilent 19362-60545 |
Agilent MFC Restrictor 0-400 ml/min Black
and purple color dot code. |
| Agilent 19362-60555 |
Agilent MFC Restrictor 0-750 ml/min Yellow
and purple color dot code. |
| Agilent 19362-60565 |
Agilent Mass Flow Controller 0-20 ml/min
For use with packed column inlets. |
| Agilent 19362-60575 |
Agilent Mass Flow Controller 0-400 cc/min
For use with capillary inlets. |
| Agilent 19363-60506 |
Agilent Pressure gauge, 0-60psi Pressure
gauge, 0-60psi. |
| Agilent 1970-0201 |
Agilent Photomultiplier, 1046A
Photomultiplier, 1046A. |
| Agilent 1970-0216 |
Agilent General GC/MS Supplies and Electron
Multipliers Galileo Electron Multiplier for use with 5970. Electron Multipliers
and Replacement Horns. |
| Agilent 200-0070 |
Agilent Column Test Standards, DB-WAX For
microbore. 0.05 & 0.10 mm I.D. Compare your column's performance to the
test chromatogram shipped with your J&W column. The column test standard
contains components that test the column for resolution characteristics columns
efficiency, and inertness. |
| Agilent 200-0185 |
Agilent Column Test Standards, DB-5ms For
capillary. 0.18 to 0.32 mm I.D. Compare your column's performance to the test
chromatogram shipped with your J&W column. The column test standard
contains components that test the column for resolution characteristics columns
efficiency, and inertness. |
| Agilent 200-0310 |
Agilent QA/QC Capillary Column Test
Standard |
| Agilent 210-2066-H |
Agilent Liners, HP5880 / 5890 / 6890 / 4890
Hot On-column, I.D.: 4.0 mm. Wool Packing: N. Dimensions 6.3 x 78.5. |
| Agilent 210-3003 |
Agilent Liners, HP5880 / 5890 / 6890 / 4890
Straight. I.D.: 4.0 mm. Wool Packing: N. Dimensions 6.3 x 78.5. Straight Liners
provide the ultimate flexibility for injections. You can easily pack these
liners with glass wool. Also, Straight Liners can be easily cleaned and
regenerated. |
| Agilent 210-3003-5 |
Agilent Liners, HP5880 / 5890 / 6890 / 4890
Straight. I.D.: 4.0 mm. Wool Packing: N. Dimensions 6.3 x 78.5. Straight Liners
provide the ultimate flexibility for injections. You can easily pack these
liners with glass wool. Also, Straight Liners can be easily cleaned and
regenerated. |
| Agilent 210-4004-5 |
Agilent Liners, HP5880 / 5890 / 6890 / 4890
FocusLiner. I.D.: 4.0 mm. Wool Packing: Y. Dimensions 6.3 x 78.5. Improve
reproducibility, improve results. The FocusLiner traps a glass wool plug in the
ideal position in the injection portliner. |
| Agilent 2140-0813 |
Agilent Deuterium Lamp 1100DAD/MWD longlife
- A 58. |
| Agilent 220-1170 |
Agilent ADM1000 Flowmeter Portable.
Microprocessor controlled. Digital. Measures flow rates from 0.1 to
1000ml/minute with accuracy of +-3%. Autoranging LCD display with continuous
reading of split flow ratios. Measures all non-corrosive gases. Calibrated and
traceable to NIST standards. 9V battery. |
| Agilent 220-1171-U |
Agilent ADM2000 Flowmeter Accurately
measures flow rates from 0.1 to 1000ml/minute, accurate to +-3%. Digital
display with continuous reading of split flow ratios. Measures all
non-corrosive gases. RS 232 data port. Mass flow rate measurement (sccm).
Calibrated and traceable to NIST standards. 9V or AC. |
| Agilent 220-1179 |
Agilent Tubing Extender Kit Flowmeter. |
| Agilent 2307230001 |
Agilent Union Zero dead volume,
deactivated. |
| Agilent 2307232901 |
Agilent Union For use with the G1888A
Headspace. |
| Agilent 2307601004 |
Agilent Tubing Assembly 6-port valve to
solenoid valves, deactivated. |
| Agilent 2321700003 |
Agilent Sample loop Headspace deactivated
1mL. |
| Agilent 2321700004 |
Agilent Sample Loop Headspace deactivated
3mL. |
| Agilent 2322590004 |
Agilent Needle Headspace Transfer line
0.5mm OD. |
| Agilent 2322590005 |
Agilent Needle Headspace Transfer line
0.7mm OD. |
| Agilent 2322700011 |
Agilent Sample probe For G1888A,
deactivated. |
| Agilent 232279012EHS |
Agilent Needle Assembly Vial Probe Needle
assembly vial probe, deactivated |
| Agilent 250-030-DAN |
Agilent Silicone septa, pack of 100 |
| Agilent 280959-001 |
Agilent Frit, 2um for 9.4mm id columns
Frit, 2um for 9.4mm id columns. |
| Agilent 280959-006 |
Agilent Frit, 2um for 3.0mm id columns
Frit, 2um for 3.0mm id columns. |
| Agilent 301-011-HSP |
Agilent HP 7694 Headspace Analysis Supplies
Transfer line, 80 cm, nickel. |
| Agilent 301-017-HSP |
Agilent HP 7694 Headspace Analysis Supplies
Oven adaptor for 10 ml vials. |
| Agilent 301-152-HSP |
Agilent HP 7694 Headspace Analysis Supplies
Transfer line, 1 m, nickel. |
| Agilent 301-162-HSP |
Agilent Tube, pressure or flow tee, 7694
Tube, pressure or flow tee, 7694. |
| Agilent 301-163-HSP |
Agilent Valve For assy tube press kit. |
| Agilent 301-164-HSP |
Agilent Tube, T-six port valve Tube, T-six
port valve. |
| Agilent 301-168-HSP |
Agilent Tube, T-six port valve Tube, T-six
port valve. |
| Agilent 301-169-HSP |
Agilent HP 7694 Headspace Analysis Supplies
Tube, needle, 6-port valve, nickel. |
| Agilent 301-170-HSP |
Agilent HP 7694 Headspace Analysis Supplies
Tube, vent-valve stainless steel. |
| Agilent 301-171-HSP |
Agilent Tube, bulkhead-pressure regulator
Tube, bulkhead-pressure regulator. |
| Agilent 301-212-HSP |
Agilent HP 7694 Headspace Analysis Supplies
Tube, needle, 6-port valve, Silcosteel. |
| Agilent 303-0034 |
Agilent Screw 6-32 x 1/4, Pan, Phil, Int
Sim. |
| Agilent 3150-0374 |
Agilent HP 5921/G2350A Atomic Emission
Detector Supplies HP 5921/G2350A Common Parts. 1/4 in. filter-60 um water
filter element (external water system only). Environmental laboratories are
using the Atomic Emission Detector (AED) to make GC analysis of unknowns faster
and more accurate. |
| Agilent 3150-0404 |
Agilent Filter, 7um Replacement for in-line
filter 0101-0532, used with GC effluent splitters. |
| Agilent 3150-0417 |
Agilent HP 5921/G2350A Atomic Emission
Detector Supplies HP 5921/G2350A Common Parts. Fly ash filter. Environmental
laboratories are using the Atomic Emission Detector (AED) to make GC analysis
of unknowns faster and more accurate. |
| Agilent 3150-0462 |
Agilent General Parts and Supplies for
HP1090 Large air filter for HP 1090 mainframe. |
| Agilent 3150-0463 |
Agilent General Parts and Supplies for
HP1090 Small dust filter for HP 1090 mainframe. |
| Agilent 3150-0509 |
Agilent Fluoropolymer resin filter membrane
47mm 10/pk Pore size 1-2 um -compatible with all solvents, acids and bases-
contains no extractables which might compromise the filtrate- inherently
hydrophobic, however, can be used for both organic and aqueous solvents |
| Agilent 3150-0559 |
Agilent HP 59980B Particle Beam Supplies
Frits. LC/MS Supplies. |
| Agilent 3150-0617 |
Agilent HP 5921/G2350A Atomic Emission
Detector Supplies HP 5921/G2350A Common Parts. 1/4 in. filter-5 um water filter
element (internal water system only). Environmental laboratories are using the
Atomic Emission Detector (AED) to make GC analysis of unknowns faster and more
accurate. |
| Agilent 3150-0619 |
Agilent Air filter, 5 um Spare Parts. CE
AND CE/MS. |
| Agilent 3150-0942 |
Agilent General Parts and Supplies for
HP1090 Helium inlet. |
| Agilent 3150-0944 |
Agilent Glass Filter, Solvent Inlet For
Agilent G1361A 1100 Series Preparative Pump. 40um pore size. |
| Agilent 3162-0083 |
Agilent HP 5985/87/88 Parts and Supplies
Copper wool trap material for Leybold D8A rough pumps and Edwards rough pumps
on HP 5985B with LC/MS. Vacuum System Supplies. |
| Agilent 3162-0110 |
Agilent O-ring kit O-ring kit. |
| Agilent 321-002-HSP |
Agilent HP 7694 Headspace Analysis Supplies
Restrictor, stainless steel. |
| Agilent 321-055-HSP |
Agilent HP 7694 Headspace Analysis Supplies
Sample loop, 1 cc, nickel. |
| Agilent 321-056-HSP |
Agilent HP 7694 Headspace Analysis Supplies
Sample loop, 3 cc, nickel. |
| Agilent 321-057-HSP |
Agilent Sensor tube, 125mm PTFE Sensor
tube, 125mm PTFE. |
| Agilent 325-0016 |
Agilent Fluoropolymer resin Insert
1.6mm. |
| Agilent 325-019-HSP |
Agilent Nylon washer 4.8 x 8.0 x 0.5m Nylon
washer 4.8 x 8.0 x 0.5m. |
| Agilent 325-045-HSP |
Agilent HP 7694 Headspace Analysis Supplies
Zero dead volume union. |
| Agilent 325-062-HSP |
Agilent Union FF 6 MB 5 piece set Union FF
6 MB 5 piece set. |
| Agilent 325-132-HSP |
Agilent Union Tee 6MB-5. |
| Agilent 325-185-HSP |
Agilent Union T 5 MA, SS Union T 5 MA,
SS. |
| Agilent 325-455-HSP |
Agilent Nut Stainless Steel, 5mm. |
| Agilent 330-055-HSP |
Agilent HP 7694 Headspace Analysis Supplies
Flow controller. |
| Agilent 35900-60570 |
Agilent Analog signal cable, 5880 to
integrator Analog signal cable, 5880 to integrator. |
| Agilent 35900-60600 |
Agilent Cables from HP Integrators to HP
1090 Series, HP 1040 Diode-Array Detector Analog. |
| Agilent 35900-60620 |
Agilent Analog signal cable, 5710/30 to
integrator Analog signal cable, 5710/30 to integrator. |
| Agilent 35900-60630 |
Agilent Cables from HP Integrators to
General Purpose Analog. |
| Agilent 35900-60640 |
Agilent Analog signal cable for special
purpose From integrator to square pins. |
| Agilent 35900-60670 |
Agilent Instrument Interface Cables Remote
start cable for general use with lug. |
| Agilent 35900-60700 |
Agilent Remote cable to 5890 Remote cable
to 5890. |
| Agilent 35900-60710 |
Agilent Remote cable to 1090 Remote cable
to 1090. |
| Agilent 35900-60750 |
Agilent Cables from HP Integrators to HP
1050 Series Analog. |
| Agilent 35900-60900 |
Agilent Analog signal for general purpose,
5m Analog signal for general purpose, 5m. |
| Agilent 35900-60910 |
Agilent Analog signal for general purpose,
15m Analog signal for general purpose, 15m. |
| Agilent 35900-60920 |
Agilent Remote cable for general purpose,
5m Remote cable for general purpose, 5m. |
| Agilent 35900-60960 |
Agilent Y-Remote Adapter Cable Converts 25
pin to 29 pin cable. |
| Agilent 35900-60970 |
Agilent Remote Cable For
7673/5890/35900. |
| Agilent 35900-60980 |
Agilent Remote Y-Cable 5890/7673 to
integrator. |
| Agilent 3980-0672 |
Agilent HP 1090 Pump and Flow Path Supplies
Sapphire piston for HP 1090. |
| Agilent 410103101 |
Agilent Transferlien Deactivated
Transferline deactivated |
| Agilent 410105007 |
Agilent Pressure Regulator Pressure
regulator with knob |
| Agilent 410105010 |
Agilent Flow Controller Flow controller
with knob |
| Agilent 410105017 |
Agilent Tubing Tubing, solenoids to 6-port,
deactivated |
| Agilent 410205001 |
Agilent Link Repair Kit Tray chain link
repair kit |
| Agilent 420-1000 |
Agilent Column Installation Kit,
Diamond-Tipped Column Cutting Pencil Column Installation Kit, Diamond-Tipped
Column Cutting Pencil. |
| Agilent 430-1020 |
Agilent Magnifier, 20X 20X replacement or
accessory magnifier for use with chromatography systems. |
| Agilent 430-2000 |
Agilent J&W Scientific Column
Installation Kit Contains diamond-tipped pencil, ferrule removal tool, 20X
magnifier, septum removal tool, and a refillable 59.1mL (2oz.) bottle of Snoop*
leak detecting solution. |
| Agilent 430-3000 |
Agilent Column Rinse Kit, Capillary Rinse
Kit This kit makes solvent rinsing easy! Solvent rinsing removes many
contaminants that accumulate in columns. The contaminates are removed by
passing solvents through the column. |
| Agilent 440-1000 |
Agilent Ferrule Tool For working small,
capillary sized graphite ferrules. The tapered spiral tip allows the tool to be
easily inserted into capillary sized hole for ferrule handling or removal
purposes. Lower half of the body ridged for a secure hand grip. |
| Agilent 446910-102 |
Agilent Agilent Prep-C18 21.2x50mm,
10um. |
| Agilent 450-1000 |
Agilent Septum Tool The surgical steel tip
can get into small spaces to remove small pieces of septa and for removing
pieces of graphite ferrule. |
| Agilent 460-1002 |
Agilent Snoop* Leak test most pressurized
gas systems. Squeezable bottle includes "Snooper Tube" extendable up to 30cm.
3.8L |
| Agilent 480-0001 |
Agilent FID Cleaning Kit FID Cleaning
Kit. |
| Agilent 480-0003 |
Agilent Injection Port Cleaning Kit If
changing the liner and trimming the column does not remove contamination from
your injection port, you probably need to clean and flush your injection
port. |
| Agilent 500-1004 |
Agilent Vespel*/Graphite Ferrules One-piece
Vespel*/Graphite (60%/40%) ferrules have upper temperature limits of
400[degree]C. Preferred for GC/MS systems. Compatible with Swagelok* fittings.
1.588mm (1/16") x 0.4mm I.D. Column I.D.: 0.05 - 0.25mm. |
| Agilent 500-1005 |
Agilent Vespel*/Graphite Ferrules One-piece
Vespel*/Graphite (60%/40%) ferrules have upper temperature limits of
400[degree]C. Preferred for GC/MS systems. Compatible with Swagelok* fittings.
1.588mm (1/16") x 0.5mm I.D. Column I.D.: 0.32mm. |
| Agilent 500-1008 |
Agilent Vespel*/Graphite Ferrules One-piece
Vespel*/Graphite (60%/40%) ferrules have upper temperature limits of
400[degree]C. Preferred for GC/MS systems. Compatible with Swagelok* fittings.
1.588mm (1/16") x 0.8mm I.D. Column I.D.: 0.53mm. |
| Agilent 500-1060 |
Agilent Graphite/Vespel Ferrule For J&W
injection port conversion kits. 6mm. |
| Agilent 500-1200 |
Agilent Polyimide Sealing Resin Permanently
connects fused silica columns to glass unions. Each connection is stable to
300[degree]C. 5g size. |
| Agilent 5001-3707 |
Agilent 79851A/52 Pump Module Parts and
Supplies Outlet gold seal. HP 1050 Pump. |
| Agilent 5001-3708 |
Agilent HP 1050 TI Pump Pump Module Parts
and Supplies. Inlet gold seal. |
| Agilent 5001-3730 |
Agilent Sipper Supplies Mounting cover for
HP 8452A. UV/VIS. May be used as sample area dust cover; not compatible with HP
89075C multicell transport and HP 89090A temperature control accessory. |
| Agilent 5001-3738 |
Agilent Rod, stainless steel Use with
column holder plate 5062-2469. |
| Agilent 5001-3739 |
Agilent |
| Agilent 5001-3743 |
Agilent Seal Keeper For pump seal
wash. |
| Agilent 500-2004 |
Agilent Graphite Ferrules One-piece
graphite ferrules have upper temperature limits of 450[degree]C. Compatible
with Swagelok* fittings. 1.588mm (1/16") x 0.4mm I.D. Column I.D.: 0.05 -
0.25mm. |
| Agilent 500-2005 |
Agilent Graphite Ferrules One-piece
graphite ferrules have upper temperature limits of 450[degree]C. Compatible
with Swagelok* fittings. 1.588mm (1/16") x 0.5mm I.D. Column I.D.: 0.32mm. |
| Agilent 500-2008 |
Agilent Graphite Ferrules One-piece
graphite ferrules have upper temperature limits of 450[degree]C. Compatible
with Swagelok* fittings. 1.588mm (1/16") x 0.8mm I.D. Column I.D.: 0.53mm. |
| Agilent 500-2066 |
Agilent Liners Ferrules for J&W
Conversion Kits Graphite Ferrule for 6 mm Mega/Split-Splitless Injection Port
Liner, Double Taper (set of 10). J&W offers a wide variety of
Megaboreliners. |
| Agilent 500-2114 |
Agilent Ferrules, HP, 0.4 mm I.D Graphite.
6880, 5890 (Short Nut), 4890. 0.4 mm I.D. Column size: 0.05-0.25 mm. Ferrules.
J&W supplies graphite and graphite / vespel ferrules for your
chromatographic needs. J&W packages ferrules in wide-mouthed glass vials
for easy removal and high product purity. |
| Agilent 5020-8231 |
Agilent FID flow measuring adapter tubing
Red rubber tubing to attach FID flow measuring adpater (19301-60660) to flow
meter tubing. |
| Agilent 5020-8292 |
Agilent Ferrules and Nuts for Capillary
Columns Finger-tight column nut for <=320 um columns. Fittings can be used
with graphite ferrules only. These ferrules are recommended for use with GC
inlets and FID, NPD and ECD. |
| Agilent 5020-8293 |
Agilent Ferrules and Nuts for Capillary
Columns Finger-tight column nut for 530 um columns. Fittings can be used with
graphite ferrules only. These ferrules are recommended for use with GC inlets
and FID, NPD and ECD. |
| Agilent 5020-8294 |
Agilent Ferrules and Nuts for Capillary
Columns Blanking plug, finger-tight style. These ferrules are recommended for
use with GC inlets and FID, NPD and ECD. The 100% Vespel ferrule can be used
for most applications and will emerge from the fitting in reusable condition
time and again. |
| Agilent 5021-1816 |
Agilent Flexible Tubing (stainless steel),
without fittings Length: 105 mm. Color code: green. ID: 0.17 mm. |
| Agilent 5021-1817 |
Agilent Flexible Tubing (stainless steel),
without fittings Length: 150 mm. Color code: green. ID: 0.17 mm. |
| Agilent 5021-1818 |
Agilent Flexible Tubing (stainless steel),
without fittings Length: 280 mm. Color code: green. ID: 0.17 mm. |
| Agilent 5021-1819 |
Agilent Flexible Tubing (stainless steel),
without fittings Length: 400 mm. Color code: green. ID: 0.17 mm. |
| Agilent 5021-1820 |
Agilent Flexible Tubing (stainless steel),
without fittings Length: 105 mm. Color code: red. ID: 0.12 mm. |
| Agilent 5021-1821 |
Agilent Flexible Tubing (stainless steel),
without fittings Length: 150 mm. Color code: red. ID: 0.12 mm. |
| Agilent 5021-1822 |
Agilent Flexible Tubing (stainless steel),
without fittings Length: 280 mm. Color code: red. ID: 0.12 mm. |
| Agilent 5021-1823 |
Agilent Flexible Tubing (stainless steel),
without fittings Length: 400 mm. Color code: red. ID: 0.12 mm. |
| Agilent 5021-1831 |
Agilent OQ/PV Test Capillary 50cm. ID:
0.25mm. |
| Agilent 5021-1845 |
Agilent Cartridge Holder Easy to use
cartridge holder accommodates 2, 3, 4, and 4.6mm diameter cartridges of varying
lengths. Hardware kit for cartridge columns. |
| Agilent 5021-1846 |
Agilent Cartridge Mounting Tool Mounting
tool for replacing filters in cartridge column systems. |
| Agilent 5021-1849 |
Agilent Agilent Cartridge split collets,
2/pk Agilent Cartridge split collets, 2/pk. |
| Agilent 5021-1854 |
Agilent Agilent Cartridge compression cones
2/pk Agilent Cartridge compression cones 2/pk. |
| Agilent 5021-1866 |
Agilent HP 1049 Electrochemical Detector
Parts and Supplies Mounting clamp. |
| Agilent 5021-1867 |
Agilent HP 1049 Electrochemical Detector
Parts and Supplies Inlet connection nut and ferrule. |
| Agilent 5021-1870 |
Agilent HP 89090A Peltier Temperature
Controller Supplies Union, cell holder (Kel-F). UV/VIS. |
| Agilent 5021-1871 |
Agilent Autosampler Parts and Supplies Zero
dead-volume union, Titanium. HP 1050 TI Autosampler. |
| Agilent 5021-7107 |
Agilent Copper tubing, 1/8in 12ft Copper
tubing, 1/8in 12ft. |
| Agilent 5021-7117 |
Agilent Fluoropolymer resin tubing, 1/8in
od, per ft. fluoropolymer resin tubing, 1/8in od, per ft. |
| Agilent 5021-7127 |
Agilent 79851A/52 Pump Module Parts and
Supplies Polyethylene actuator air tubing, per meter. HP 1050 Pump. |
| Agilent 5021-7133 |
Agilent Capillary Column Connectors
Accessories for Ferrules for Graphpak Connection Systems. Plug ferrule. |
| Agilent 5021-7134 |
Agilent Capillary Column Connectors
Ferrules for Graphpak Connection Systems. Column ID: 0.53 mm. Column OD: 0.7
mm. |
| Agilent 5021-7136 |
Agilent Capillary Column Connectors
Ferrules for Graphpak Connection Systems. Column ID: 0.2 mm. Column OD: 0.3
mm. |
| Agilent 5021-7137 |
Agilent Capillary Column Connectors
Ferrules for Graphpak Connection Systems. Column ID: 0.32/0.25 mm. Column OD:
0.4 mm. |
| Agilent 5021-7146 |
Agilent Capillary Column Connectors
Graphpak Divider for Simultaneous Sampling to Two Capillary Columns. Column ID:
0.53 mm. Column OD: 0.7 mm. |
| Agilent 5021-7148 |
Agilent Capillary Column Connectors
Graphpak Divider for Simultaneous Sampling to Two Capillary Columns. Column ID:
0.32/0.25 mm. Column OD: 0.4 mm. |
| Agilent 5021-7164 |
Agilent Capillary Column Connectors
Graphpak Connector for HP Capillary Detector Ports. Column ID: 0.53 mm. Column
OD: 0.7 mm. |
| Agilent 5021-7166 |
Agilent Capillary Column Connectors
Graphpak Connector for HP Capillary Detector Ports. Column ID: 0.32/0.25 mm.
Column OD: 0.4 mm. |
| Agilent 5021-7168 |
Agilent Capillary Column Connectors
Graphpak Connector for HP Capillary Injection Ports. Column ID: 0.53 mm. Column
OD: 0.7 mm. |
| Agilent 5021-7169 |
Agilent Capillary Column Connectors
Graphpak Connector for HP Capillary Injection Ports. Column ID: 0.2 mm. Column
OD: 0.3 mm. |
| Agilent 5021-7170 |
Agilent Capillary Column Connectors
Graphpak Connector for HP Capillary Injection Ports. Column ID: 0.32/0.25 mm.
Column OD: 0.4 mm. |
| Agilent 5022-2126 |
Agilent Fused Silica To 1.6mm ttubing
connector. For connecting CEC capillaries to LC pumps for the purpose of
flushing with buffer using hydrolic pressure. |
| Agilent 5022-2145 |
Agilent True ZDV Union Top. Seal. For 500nL
Flow Cell. |
| Agilent 5022-2146 |
Agilent Union Adjustment Tool For True ZDV
Union. |
| Agilent 5022-2154 |
Agilent Tefzel Ferrule For use with
spectrophotometer sipper pump. With 1.6mm stainless steel lock rings. |
| Agilent 5022-2156 |
Agilent Cell Fittings Kit For use with
spectrophotometer flow cells. 4 short, 4 long. |
| Agilent 5022-2159 |
Agilent Capillary Stainless steel. Ferrule.
ID: 0.12. 2m. |
| Agilent 5022-2192 |
Agilent Stainless Steel Filter Assembly
With PEEK ring. For Agilent 1100 Series Preparative Pump. 2um pore size. |
| Agilent 5022-6531 |
Agilent Test tubes, 12x100 mm 250/pk. |
| Agilent 5022-6532 |
Agilent Test tubes 16x100 mm 250/pk. |
| Agilent 5022-6534 |
Agilent Test tubes 12x48 mm 100/pk. |
| Agilent 5041-2163 |
Agilent Tube Screw Use with Agilent
79851A/52 pump module. For bottle head assembly tube. |
| Agilent 5041-2166 |
Agilent Pump tubing, 2.06 mm id, 10.3
ml/min (60 Hz), 8.6 ml/min (50 Hz) UV/VIS. 12/pk. |
| Agilent 5041-2167 |
Agilent Peristaltic Pump Supplies Nylon
cassette sipper (holds pump tubing). UV/VIS. With HP 89052B pump, flow rates
are fixed. With the HP 89092A, pumping speed is variable. |
| Agilent 5041-2184 |
Agilent Pump tubing, Tygon* 1.3mm id
12/PK. |
| Agilent 5041-2185 |
Agilent Pump tubing, Tygon* 2.8mm id,
12/PK. |
| Agilent 5041-2199 |
Agilent Fittings for Flow Cells Cell
ferrules. UV/VIS. |
| Agilent 5041-8339 |
Agilent 79851A/52 Pump Module Parts and
Supplies Glass filter, 10-16 ul pore size, (for helium). HP 1050 Pump. |
| Agilent 5042-0922 |
Agilent Inner Sleeve For Agilent 7500
ICP-MS trace element measurement unit. For carrier/auxiliary/blend gas. |
| Agilent 5042-0923 |
Agilent Inner Sleeve For Agilent 7500
ICP-MS trace element measurement unit. For plasma gas line. |
| Agilent 5042-1336 |
Agilent Heat Exchanging Tube For Agilent
89090A Peltier Temperature Controller. Use for preheating of samples. |
| Agilent 5042-1356 |
Agilent Cassette For spectrophotometers.
Variable pressure. |
| Agilent 5042-6443 |
Agilent Backpressure Regulator For Agilent
part numbers G131B DAD and MWD. 100psi. |
| Agilent 5042-6500 |
Agilent Double winged 2 piece fitting
1/16inch 10pk PEEK fittings for standard 1/16inch od capillaries. |
| Agilent 5060-9055 |
Agilent HP 5880 Detector Supplies Thermal
Conductivity Detector (TCD) Replacement filament cartridge kits. Pressure check
plug. |
| Agilent 5060-9077 |
Agilent Moisture Trap not conditioned
Moisture Trap not conditioned |
| Agilent 5060-9084 |
Agilent Moisture Trap, preconditioned
Moisture trap: metal casing, s-shaped trap for carrier gas cleanup. It contains
Molecular Sieve 5Angstroms, 45/60 mesh, 1/8 in. fittings. Can be reconditioned.
These traps can be reconditioned by heating at a minimum of 350[degree]C, with
flow for 6 hours. |
| Agilent 5060-9086 |
Agilent Petrochemical Qualitative
Petrochemical Standards. Reference Gas Oil No. 1 Batch 2. Mulltiple component
mixture of hydrocarbons from petroleum fractions. Used for performance
verification of the Agilent Technologies simulated distillation analyzer,
Option 840. |
| Agilent 5060-9096 |
Agilent Hydrocarbon Trap Activated charcoal
trap: metal casing, s-shaped trap filled with 40/60 mesh activated charcoal,
used for trapping organics from gases, 1/8 in. fittings. |
| Agilent 5061-3303 |
Agilent Stainless Steel Fittings Stainless
Steel Fittings |
| Agilent 5061-3304 |
Agilent Flexible Capillary Start-Up Kit
(stainless steel) Capillary Tubing Kits. |
| Agilent 5061-3315 |
Agilent Flexible Capillary Kit (stainless
steel) Capillary Tubing Kits. |
| Agilent 5061-3325 |
Agilent HP 1050 Manual Injector Manual
Injector Parts and Supplies. Fitting kit for sample loops. Includes: 2
stainless steel fittings, 2 ferrules. |
| Agilent 5061-3327 |
Agilent Parts and Supplies for HP
1037/40/46/47/49 Detectors Parts for HP 1046 Programmable Fluorescence
Detector. Filter kit: five filters (389 nm, 408 nm, 450 nm, 500 nm, 550
nm). |
| Agilent 5061-3328 |
Agilent Parts and Supplies for HP
1037/40/46/47/49 Detectors Parts for HP 1046 Programmable Fluorescence
Detector. Filter kit: five filters (380 nm, 399 nm, 418 nm, 470 nm, 520
nm). |
| Agilent 5061-3329 |
Agilent Parts and Supplies for HP
1037/40/46/47/49 Detectors Parts for HP 1046 Programmable Fluorescence
Detector. Filter kit: five filters (280 nm, 295 nm, 305 nm, 335 nm, 345
nm). |
| Agilent 5061-3335 |
Agilent Reagents for Amino Acid Analysis
for use with HP 1100. OPA reagent, 10 mg/ml each in 0.4 M borate buffer
o-phthalaldehyde (OPA) and 3-mercaptopropionic acid, 6 ampoules. Buy limited
quantities because of shelf-life considerations. |
| Agilent 5061-3337 |
Agilent Reagents for Amino Acid Analysis
for use with HP 1100. 1 ml. FMOC reagent, 2.5 mg/ml in acetonitrile,
9-fluorenylmethylchloroformate. Buy limited quantities because of shelf-life
considerations. |
| Agilent 5061-3339 |
Agilent Reagents for Amino Acid Analysis
for use with HP 1100. 100 ml. Borate buffer. Buy limited quantities because of
shelf-life considerations. |
| Agilent 5061-3361 |
Agilent Rigid Capillary Tubing (stainless
steel), precut, without fittings Capillary Tubing Kits. 10/pk. |
| Agilent 5061-3362 |
Agilent Rigid Capillary Tubing (stainless
steel), precut, without fittings Capillary Tubing Kits. 10/pk. |
| Agilent 5061-3377 |
Agilent Sipper Supplies Sipper/sampler
cable for HP 8452A. UV/VIS. |
| Agilent 5061-3378 |
Agilent Remote Start/Stop Cables from HP
1050 Series to HP 1090 II Series, HP 1050 Series modules, 1 m Remote Start/Stop
Cables from HP 1050 Series to HP 1090 II Series, HP 1050 Series modules, 1
m |
| Agilent 5061-3384 |
Agilent Macro Cells - with PTFE lid The
macro cell which is defined by DIN 58963 as a rectangular cell with an inner
width above 5 mm, has emerged as the standard for photometry. The most widely
used macro cell is a rectangular cell with outer dimensions of 45 x 12.5 mm
(height x width). |
| Agilent 5061-3385 |
Agilent Macro Cells, with PTFE Lid Path
length: 2mm. Dimensions: 12.5Wx45Hx4.5Dmm. The macro cell (defined by DIN 58963
as a rectangular cell with an inner width above 5mm) has emerged as the
standard for photometry. |
| Agilent 5061-3386 |
Agilent Macro Cells, with PTFE Lid Path
length: 5mm. Dimensions: 12.5Wx45Hx7.5Dmm. The macro cell (defined by DIN 58963
as a rectangular cell with an inner width above 5mm) has emerged as the
standard for photometry. |
| Agilent 5061-3387 |
Agilent Macro Cells, with PTFE Lid Path
length: 10mm. Dimensions: 12.5Wx45Hx12.5Dmm. The macro cell (defined by DIN
58963 as a rectangular cell with an inner width above 5mm) has emerged as the
standard for photometry. |
| Agilent 5061-3388 |
Agilent Cell Accessories Spacer for 1 mm
cell. UV/VIS. Spacers permit accurate positioning of 1, 2, and 5 mm path length
open-topped cells in standard 10 mm path length cell holders. They are not
required for short path length flow cells because these have the same external
dimensions as the 10 mm cell. |
| Agilent 5061-3389 |
Agilent Cell Accessories Spacer for 2 mm
cell. UV/VIS. Spacers permit accurate positioning of 1, 2, and 5 mm path length
open-topped cells in standard 10 mm path length cell holders. They are not
required for short path length flow cells because these have the same external
dimensions as the 10 mm cell. |
| Agilent 5061-3390 |
Agilent Cell Accessories Spacer for 5 mm
cell. UV/VIS. Spacers permit accurate positioning of 1, 2, and 5 mm path length
open-topped cells in standard 10 mm path length cell holders. They are not
required for short path length flow cells because these have the same external
dimensions as the 10 mm cell. |
| Agilent 5061-3391 |
Agilent Quartz Semi-micro Cell With PTFE
Lid Path Length: 10mm. Exterior Dimensions: 46Hx12.5Wx12.5Dmm. Interior
Dimensions: 41.8x2mm. Volume: 700uL. |
| Agilent 5061-3392 |
Agilent Cylindrical Cells - with PTFE
stopper These cells are specifically designed for use in the ul (down to 50 ul)
where, for technical reasons, flow-through cells cannot be used. |
| Agilent 5061-3396 |
Agilent Flow Cells - rectangular aperture
with screw fittings Standard cells are rectangular cells with standardized
exterior dimensions. These cells fit into all common analytical instruments
such as calorimeters, photometers, and spectrophotometers. |
| Agilent 5061-3397 |
Agilent Flow Cells - rectangular aperture
with screw fittings Standard cells are rectangular cells with standardized
exterior dimensions. These cells fit into all common analytical instruments
such as calorimeters, photometers, and spectrophotometers. |
| Agilent 5061-3398 |
Agilent Flow Cells - rectangular aperture
with screw fittings Standard cells are rectangular cells with standardized
exterior dimensions. These cells fit into all common analytical instruments
such as calorimeters, photometers, and spectrophotometers. |
| Agilent 5061-5801 |
Agilent Capillary Column Connectors Metal
Capillary Column Connectors. Connector, body and nut. |
| Agilent 5061-5804 |
Agilent Capillary Column Connectors
Ferrules, for connecting: 0.2- to 0.53-mm id tubing. |
| Agilent 5061-5805 |
Agilent Capillary Column Connectors
Ferrules, for connecting: 0.32- to 0.32-mm id tubing. |
| Agilent 5061-5806 |
Agilent Capillary Column Connectors
Ferrules, for connecting: 0.32- to 0.53-mm id tubing. |
| Agilent 5061-5853 |
Agilent HP 5970 MSD Parts and Supplies
Truarc clip, large. |
| Agilent 5061-5867 |
Agilent HP 5890 Detector Supplies FPD
Supplies. O-ring. |
| Agilent 5061-5869 |
Agilent HP 5890 Split/Splitless Multimode
Inlet Split/Splitless Inlet Parts. Washer. |
| Agilent 5061-5870 |
Agilent HP 5970 MSD Parts and Supplies
Washer, flat. |
| Agilent 5061-5871 |
Agilent HP 5970 MSD Parts and Supplies
Washer, curved spring. |
| Agilent 5061-5886 |
Agilent HP 5890 Detector Supplies FPD
Supplies. Window O-ring, inner. |
| Agilent 5061-5889 |
Agilent HP 5890 Detector Supplies FPD
Supplies. Viton O-ring, brown, 0.926 in. id. |
| Agilent 5061-5890 |
Agilent HP 5890 Detector Supplies FPD
Supplies. Viton O-ring, brown, 1.239 in. id. |
| Agilent 5061-5891 |
Agilent HP 5890 Detector Supplies FPD
Supplies. Window O-ring, outer. |
| Agilent 5061-5896 |
Agilent Abrasive Sheet Aluminum oxide green
lapping paper for ion source cleaning, 600 mesh. 3um. |
| Agilent 5062-2418 |
Agilent Stainless Steel Fittings Fittings
and ferrules, 1/16 in. 10/ea. |
| Agilent 5062-2419 |
Agilent PEEK Tubing and Fittings Safety
tubing for PEEK tubing, fluoropolymer resin, 2 x 3 mm, 5 m. |
| Agilent 5062-2461 |
Agilent 79851A/52 Pump Module Parts and
Supplies Helium tubing, 5 m, fluoropolymer resin,.057 in. id. HP 1050
Pump. |
| Agilent 5062-2462 |
Agilent Tubing fluoropolymer resin tubing.
I.D.: 0.7mm. Length: 5m. 1050 module flow connector from detector to
waste. |
| Agilent 5062-2463 |
Agilent HP 1100 Series LC Autosampler
Supplies G1313A Autosampler Parts and Supplies. Waste tubing, 5 m, 6.5 mm id,
corrugated tubing polypropylene. |
| Agilent 5062-2465 |
Agilent Support ring for 1050 seal wash
option Support ring for 1050 seal wash option. |
| Agilent 5062-2469 |
Agilent Column holder assembly Must also
order support rod 5001-3738. |
| Agilent 5062-2474 |
Agilent HP 1049 Electrochemical Detector
Parts and Supplies Silicone tubing. |
| Agilent 5062-2476 |
Agilent Flow Cells - rectangular aperture
with screw fittings Standard cells are rectangular cells with standardized
exterior dimensions. These cells fit into all common analytical instruments
such as calorimeters, photometers, and spectrophotometers. |
| Agilent 5062-2477 |
Agilent Macro Cells - with PTFE stopper The
macro cell which is defined by DIN 58963 as a rectangular cell with an inner
width above 5 mm, has emerged as the standard for photometry. The most widely
used macro cell is a rectangular cell with outer dimensions of 45 x 12.5 mm
(height x width). |
| Agilent 5062-2479 |
Agilent Reagents for Amino Acid Analysis
for use with HP 1100. 5 g. DTDPA (Dithiodiproprionic) reagent for analysis or
cysteine. Buy limited quantities because of shelf-life considerations. |
| Agilent 5062-2480 |
Agilent Anion chromatography kit Mobile
phase additive. Includes: LC cartridge, cartridge holder, mobile phase
additive, sodium hydroxide solutions, check out sample, handbook. Buy limited
quantities because of shelf-life considerations. |
| Agilent 5062-2483 |
Agilent 79851A/52 Pump Module Parts and
Supplies Solvent tubing, FEP, 5 m, 1.5 mm id, 3 mm od. HP 1050 Pump. |
| Agilent 5062-2484 |
Agilent 79851A/52 Pump Module Parts and
Supplies Gasket, wash seal. HP 1050 Pump. |
| Agilent 5062-2485 |
Agilent 79851A/52 Pump Module Parts and
Supplies Outlet caps. HP 1050 Pump. |
| Agilent 5062-2486 |
Agilent 79851A/52 Pump Module Parts and
Supplies Velocity regulator. HP 1050 Pump. |
| Agilent 5062-2494 |
Agilent HP 1090 Pump and Flow Path Supplies
Pump seal, Black Vespel. |
| Agilent 5062-2495 |
Agilent HP Automatic Liquid Sampler
Supplies Crimping System. Holder without crimp head, to be mounted. |
| Agilent 5062-2496 |
Agilent Ultra-micro Cells - with PTFE
stopper These cells are specifically designed for use in the ul (down to 50 ul)
where, for technical reasons, flow-through cells cannot be used. |
| Agilent 5062-2497 |
Agilent Macro Cells - with PTFE stopper
These cells are specifically designed for use in the ul (down to 50 ul) where,
for technical reasons, flow-through cells cannot be used. These cells fit into
any standard cell holder and have the advantage of requiring much smaller
sample volumes than standard cells. |
| Agilent 5062-3506 |
Agilent Vespel*/Graphite Capillary Inlet
Ferrules 0.5mm Preconditioned 15% Graphite, 85% Vespel ferrules have an upper
temperature limit of 400[degree]C, and are recommended for use with GC/MS.
Column ID: 0.32mm. |
| Agilent 5062-3507 |
Agilent Ferrules and Nuts for Capillary
Columns Preconditioned 85% Vespel, 15% Graphite Ferrules. Ferrule ID: 0.3 mm.
Column ID: 100 um. These ferrules are recommended for use with GC/MS. |
| Agilent 5062-3508 |
Agilent Vespel*/Graphite Capillary Inlet
Ferrules 0.4mm Preconditioned 15% Graphite, 85% Vespel ferrules have an upper
temperature limit of 400[degree]C, and are recommended for use with GC/MS.
Column ID: 0.20-0.25mm. |
| Agilent 5062-3509 |
Agilent Capillary Column Connectors Glass
Connector Trial Kit for Capillary Columns. Kit contains 3 ea of 530- to 530-um,
530- to 320-um, 530- to 200-um, 200- to 320-um, 200- to 200-um. |
| Agilent 5062-3511 |
Agilent Vespel* Capillary Inlet Ferrules
0.8mm 100% Vespel ferrules are made from high-temperature polyimide and have an
upper temperature limit of 350[degree]C. Column ID: 0.53mm. |
| Agilent 5062-3512 |
Agilent Vespel*/Graphite Capillary Inlet
Ferrules 0.8mm. 85% Vespel, 15% Graphite ferrules have an upper temperature
limit of 400[degree]C. Column ID: 0.53mm. |
| Agilent 5062-3513 |
Agilent Ferrules and Nuts for Capillary
Columns 100% Vespel High-Performance Ferrules. Ferrule ID: 0.47 mm. Column ID:
320 um. These ferrules are recommended for use with GC inlets and FID, NPD and
ECD. |
| Agilent 5062-3514 |
Agilent Vespel*/Graphite Capillary Inlet
Ferrules 0.5mm. 85% Vespel, 15% Graphite ferrules have an upper temperature
limit of 400[degree]C. Column ID: 0.32mm. |
| Agilent 5062-3515 |
Agilent Ferrules and Nuts for Capillary
Columns 100% Vespel High-Performance Ferrules. Ferrule ID: 0.37 mm. Column ID:
200 um. These ferrules are recommended for use with GC inlets and FID, NPD and
ECD. |
| Agilent 5062-3516 |
Agilent Ferrules and Nuts for Capillary
Columns 85% Vespel, 15% Graphite Ferrules. Ferrule ID: 0.37 mm. Column ID: 200
um. These ferrules are recommended for use with GC inlets and FID, NPD and
ECD. |
| Agilent 5062-3518 |
Agilent Ferrules and Nuts for Capillary
Columns 85% Vespel, 15% Graphite Ferrules. Ferrule ID: 0.27 mm. Column ID: 100
um. These ferrules are recommended for use with GC inlets and FID, NPD and
ECD. |
| Agilent 5062-3525 |
Agilent Capillary Column Connectors
Accessories for Ferrules for Graphpak Connection Systems. Replacement column
nut. |
| Agilent 5062-3538 |
Agilent Vespel*/Graphite Capillary Inlet
Ferrules 0.8mm. Preconditioned 15% Graphite, 85% Vespel ferrules have an upper
temperature limit of 400[degree]C, and are recommended for use with GC/MS.
Column ID: 0.53mm. |
| Agilent 5062-3550 |
Agilent Capillary Column Connectors Glass
Press-Fit Connector for: 0.32- to 0.25-mm tubing. |
| Agilent 5062-3551 |
Agilent Capillary Column Connectors Glass
Press-Fit Connector for: 0.53- to 0.25-mm tubing. |
| Agilent 5062-3552 |
Agilent Capillary Column Connectors Glass
Press-Fit Connector for: 0.1- to 0.32-mm tubing. |
| Agilent 5062-3553 |
Agilent Capillary Column Connectors Glass
Press-Fit Connector for: 0.1- to 0.25-mm tubing. |
| Agilent 5062-3554 |
Agilent Capillary Column Connectors Glass
Press-Fit Connector for: 0.32- to 0.25-mm tubing. |
| Agilent 5062-3556 |
Agilent Glass Press-Fit connector 250-250um
10/pk (equivalent to J&W C2002-10 and C2002-5) |
| Agilent 5062-3561 |
Agilent Paper and Supplies for HP 3397A, HP
3396 Series III, and HP 3396A/B/95/94 Z-fold paper, sequentially numbered, 8.5
x 11 in. InkJet (5 pk/box) (2,500 sheets). |
| Agilent 5062-3580 |
Agilent Capillary Splitters Two-hole
replacement ferrules. Tubing ID: 0.4 mm. |
| Agilent 5062-3581 |
Agilent Capillary Splitters Two-hole
replacement ferrules. Tubing ID: 0.5 mm. |
| Agilent 5062-3587 |
Agilent Single Taper Liner for Capillary
Inlet Systems 4mmIDx0.8IDmm taper. Volume: 900uL. For sensitive compounds.
Borosilicate glass. 10gm silanized glass wool packing ensures mixing and traps
septum particles, preventing them from reaching the column. |
| Agilent 5062-8514 |
Agilent Back ferrule 1/16" gold plated
10/PK Back ferrule 1/16" gold plated 10/PK. |
| Agilent 5062-8515 |
Agilent 79851A/52 Pump Module Parts and
Supplies Connector for helium sparger. HP 1050 Pump. |
| Agilent 5062-8517 |
Agilent Filter Frit Adapter PTFE 3 mm.
Spare Parts. CE AND CE/MS. |
| Agilent 5062-8518 |
Agilent G1303 Online Degasser Parts and
Supplies Male nuts. HP 1050 Online Degasser. |
| Agilent 5062-8519 |
Agilent G1303 Online Degasser Parts and
Supplies Ferrules. HP 1050 Online Degasser. |
| Agilent 5062-8522 |
Agilent 79853C Variable Wavelength Detector
(VWD) Supplies PEEK inlet tubing assembly, 40 cm,.007 in. id, 1/16 in. od. HP
1050 TI Detector. |
| Agilent 5062-8524 |
Agilent CE AND CE/MS Anion Test Mixture
(Cl, Br, SO4, NO3, NO2, F, PO4), also used for HPLC. Inorganic Anion Solutions
Kit. Using an indirect-UV detection system optimized for small anions, analyses
are sensitive and rapid and provide an alternative to traditional ion
chromatography. |
| Agilent 5062-8529 |
Agilent Cell cleaning fluid, 1L |
| Agilent 5062-8530 |
Agilent Parts and Supplies for HP
1037/40/46/47/49 Detectors Parts for HP 1046 Programmable Fluorescence
Detector. Cutoff filter, 295 nm. |
| Agilent 5062-8535 |
Agilent Outlet tubing |
| Agilent 5062-8541 |
Agilent PEEK Tubing and Fittings
Finger-tight fittings, long, 1/16 in. 10/pk. |
| Agilent 5062-8544 |
Agilent Electrode O-ring, silicone Spare
Parts. CE AND CE/MS. |
| Agilent 5062-8553 |
Agilent Washer 10pk |
| Agilent 5062-8562 |
Agilent Cartridge For active inlet valve
(HPG1312-60010). |
| Agilent 5062-8574 |
Agilent 50 mM sodium tetraborate, 100 mM
sodium dodecyl sulfate buffer, pH 9.3 Micellar Electrokinetic Chromatography
(MEKC) Buffer for Neutral and Charged Analytes. CE AND CE/MS. 250 ml. Micellar
Electrokinetic Chromatography (MEKC) Buffer for Neutral and Charged
Analytes. |
| Agilent 5062-8587 |
Agilent Sapphire Piston For 900uL sampler
option. |
| Agilent 5062-9508 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 General-Purpose Valves, Gas sampling. 6 port replacement valve WE
series, 400 psi, 225[degree]C. |
| Agilent 5062-9509 |
Agilent 6-Port Valve WE series.
Hastelloy-C. Maximum temperature: 225[degree]C. |
| Agilent 5062-9510 |
Agilent GC Valves and Loops Compatible with
HP 5890/6890 General-Purpose Valves. Gas sampling. 10 port replacement valve WE
series, 400 psi, 225[degree]C. |
| Agilent 5062-9511 |
Agilent GC 10-Port Valve WE series.
Hastelloy C. 400 psi. 225[degree]C. |
| Agilent 5063-6505 |
Agilent Stainless Steel Sieve Outlet Valve
Replacement part for servicing an 1100 binary pump. |
| Agilent 5063-6506 |
Agilent Finger Cap For vial gripper. |
| Agilent 5063-6531 |
Agilent Bottle Cap with 3-Hole Insert For
Agilent G1311/12/54A Standard Pumps. |
| Agilent 5063-6586 |
Agilent 79851A/52 Pump Module Parts and
Supplies Sapphire piston (plunger). HP 1050 Pump. |
| Agilent 5063-6589 |
Agilent Piston seals for Agilent 1100/1050,
Vespel, 2/pk Graphitized fluoropolymer resin. |
| Agilent 5063-6591 |
Agilent Finger-tight PEEK Long Fittings
1.6mm. |
| Agilent 5063-6592 |
Agilent Upchurch Liteouch Ferrules
Lifetouch 100. Front and back. |
| Agilent 5063-6593 |
Agilent Nut For capillary LC. Stainless
steel. 1.6mm. 4mm fittings. |
| Agilent 5063-6596 |
Agilent Preventive Maintenance Kit For
HP1090. |
| Agilent 5063-6598 |
Agilent Tefzel Ferrule with Stainless Steel
Lock Ring 3.2mm. Excellent chemical resistance to most solvents. 1200psi.
Maximum Temperature: 23[degree]C. |
| Agilent 5063-6599 |
Agilent Polyphenylene Sulfide Nut For 3.2mm
OD tubing. 1/4-28 thread. Excellent chemical resistance to most organic
solvents at room temperature. 4100psi. Maximum Temperature: 50[degree]C. |
| Agilent 5064-8034 |
Agilent Tygon Peristalitic Pump Tubing For
Agilent 7500 Pump. I.D.: 0.25mm. 3 stops. |
| Agilent 5064-8078 |
Agilent 4mm Union Fitting PFConcentric
Nebulizer 7500 ICP-MS (inductively coupled plasma mass spectrometer ). |
| Agilent 5065-4422 |
Agilent Double Winged Nut With 0.79mm
ferrule. |
| Agilent 5065-4423 |
Agilent Ferrule 0.79mm. For capillary LC.
With stainless steel lock ring. |
| Agilent 5065-9915 |
Agilent Holder for 5 mm trap
cartridges |
| Agilent 5065-9931 |
Agilent Flex capillary 0.17x200mm, no
fittings, stainless steel. |
| Agilent 5065-9932 |
Agilent Flex capillary 0.17x700mm, no
fittings, stainless steel. |
| Agilent 5065-9933 |
Agilent Flex capillary 0.17x600mm, no
fittings, stainless steel. |
| Agilent 5065-9967 |
Agilent X-Long fittings and ferrules
Stainless Steel, 10/PK, for 1/16inch od tubing, 10-32 thread. Front and back
ferrules. |
| Agilent 5065-9978 |
Agilent Silicone Tubing 1mm ID, 3mm OD, 5m
used with wash option. |
| Agilent 5067-0223 |
Agilent Precision Gas Flow Meter Flow
range: 5 - 500 ml/min |
| Agilent 5067-1547 |
Agilent PEEK Ferrule PEEK ferrule for 1/16
inch od capillaries, max 600 bar pressure, 6/pk. Replacement ferrule for
5067-1540 ferrule plus fitting. |
| Agilent 5067-1551 |
Agilent In-line Filter High pressure (max
600 bar) in-line filter for RRLC applications. Comes with 3 x 2 mm, 0.2 um
pores size frits and a 70 x 0.12 mm SS connecting capillary |
| Agilent 5067-1553 |
Agilent In-line Filter High pressure (max
600 bar) in-line filter for RRLC applications. Comes with 3 x 4.6 mm, 0.2 um
pores size frits and a 90 x 0.17 mm SS connecting capillary |
|