Online sales of Agilent J&W, DB GC Chromatography Columns. Discounts on all Agilent J&W GC Columns, Agilent Agilent J&W DB Columns, Agilent J&W HP Columns and all GC Chromatography supplies by Agilent Technologies. Discounts on Agilent Technology J&W GC columns are available to resellers, University and Government customers with a starting 10% discount if ordered online or by fax..

Download the complete Agilent Technologies Catalog - Click Here

ORDER AGILENT TECHNOLOGIES J&W GC COLUMNS ONLINE OR BY FAX AND RECEIVE A 10% DISCOUNT.

 AGILENT ITEM NO. AGILENT GC COLUMN DESCRIPTION
Agilent 009-1075 Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 500mm ID. Length: 6000mm. Film: 1.5um. Temperature Range: -600 to 325[degree]C.
Agilent 0100-0050 Agilent Caps Stainless Steel. 1/16 in. cap.
Agilent 0100-0058 Agilent Nut Brass. 3.2mm.
Agilent 0100-0073 Agilent Reducers Stainless Steel. 1/16 1/8 in. reducer.
Agilent 0100-0089 Agilent Tees Stainless Steel. 1/4 in. tee.
Agilent 0100-0091 Agilent Elbows Brass. 1/8 in.
Agilent 0100-0111 Agilent Connectors (Swagelok to Male NPT) Stainless Steel. 1/8 1/8 in. connector.
Agilent 0100-0118 Agilent Connectors (Swagelok to Female NPT) Brass. 1/8 1/4 in. connector.
Agilent 0100-0119 Agilent Connectors (Swagelok to Female NPT) Brass. 1/4 1/4 in. connector.
Agilent 0100-0121 Agilent Reducing Unions Stainless Steel. 1/8 x 1/4 in. reducing union.
Agilent 0100-0124 Agilent Union Stainless Steel. 1/16 in. union.
Agilent 0100-0126 Agilent Union Stainless Steel. 1/8 in. union.
Agilent 0100-0128 Agilent Union Stainless Steel. 1/4 in. union.
Agilent 0100-0132 Agilent Bulkhead Unions Brass. 1/8 in. bulkhead union.
Agilent 0100-0133 Agilent Bulkhead Unions Stainless Steel. 1/8 in. bulkhead union.
Agilent 0100-0160 Agilent General GC/MS Supplies and Electron Multipliers fluoropolymer resin 1/4 in. O-ring (back). Cleaning and Maintenance Supplies.
Agilent 0100-0161 Agilent Cross Brass. 1/8 in.
Agilent 0100-0241 Agilent Reducing Unions Stainless Steel. 1/16 x 1/8 in. reducing union.
Agilent 0100-0420 Agilent Adapters Brass. 1/8 x 1/8 in. adapter.
Agilent 0100-0782 Agilent Tees Stainless Steel. 1/16 in. tee.
Agilent 0100-0787 Agilent General GC/MS Supplies and Electron Multipliers fluoropolymer resin 1/4 in. O-ring (front). Cleaning and Maintenance Supplies.
Agilent 0100-0929 Agilent Nut, male 1/16in SS Nut, male 1/16in SS.
Agilent 0100-0985 Agilent Cross Brass. 1/4 in.
Agilent 0100-1017 Agilent HP 1090 Pump and Flow Path Supplies Union, 1/16 in., stainless steel.
Agilent 0100-1104 Agilent Straight Ferrules 6.4 mm Vespel. For Capillary Columns.
Agilent 0100-1107 Agilent Front Ferrule Graph Vespel. 3.2mm ID.
Agilent 0100-1145 Agilent Interface gasket, VCR nickel Interface gasket, VCR nickel.
Agilent 0100-1189 Agilent Connectors (Swagelok to Male NPT) Stainless Steel. 1/8 1/4 in. connector.
Agilent 0100-1316 Agilent Union Brass. 1/16 in. union.
Agilent 0100-1324 Agilent Straight Ferrules 1/4 in. graphite. For Capillary Columns.
Agilent 0100-1325 Agilent Straight Ferrules 1/8 in. graphite. For Capillary Columns.
Agilent 0100-1326 Agilent Straight Ferrules 1/16 in. graphite. For Capillary Columns.
Agilent 0100-1327 Agilent HP 5921/G2350A Atomic Emission Detector Supplies HP 5921/G2350A Common Parts. 1/4 in. Vespel ferrules. Environmental laboratories are using the Atomic Emission Detector (AED) to make GC analysis of unknowns faster and more accurate.
Agilent 0100-1328 Agilent General GC/MS Supplies and Electron Multipliers Ferrule, 1/8 in. Vespel. Ferrules for Capillary Direct or Open-Split Interface.
Agilent 0100-1329 Agilent HP 5921/G2350A Atomic Emission Detector Supplies HP 5921/G2350A Common Parts. 1/16 in. Vespel ferrules. Environmental laboratories are using the Atomic Emission Detector (AED) to make GC analysis of unknowns faster and more accurate.
Agilent 0100-1331 Agilent General GC/MS Supplies and Electron Multipliers Ferrule, 1/4 in. Vespel. Ferrules for Capillary Direct or Open-Split Interface.
Agilent 0100-1332 Agilent General GC/MS Supplies and Electron Multipliers Ferrule, 1/8 in. Vespel. Ferrules for Capillary Direct or Open-Split Interface.
Agilent 0100-1333 Agilent General GC/MS Supplies and Electron Multipliers Ferrule, 1/16 in. Vespel. Ferrules for Capillary Direct or Open-Split Interface.
Agilent 0100-1342 Agilent Reducing Ferrules 1/8 to 1/16 in. Vespel. For Capillary Columns.
Agilent 0100-1344 Agilent Reducing Ferrules 1/8 to 1/16 in. VG-1 Vespel, 15% graphite. For Capillary Columns.
Agilent 0100-1354 Agilent HP 5985/87/88 Parts and Supplies Ferrule for jet separator, 0.8 mm Vespel. Sample Introduction Parts, GC/MS.
Agilent 0100-1365 Agilent HP 5921/G2350A Atomic Emission Detector Supplies HP 5921/G2350A Common Parts. 1/8 in. Vespel ferrules. Environmental laboratories are using the Atomic Emission Detector (AED) to make GC analysis of unknowns faster and more accurate.
Agilent 0100-1372 Agilent Ferrule, 1/8in 60%Vespel, no hole 10/pk Ferrule, 1/8in 60%Vespel, no hole 10/pk.
Agilent 0100-1375 Agilent Straight Ferrules 1/16 in. fluoropolymer resin. For Capillary Columns.
Agilent 0100-1378 Agilent Straight Ferrules 1/4 in. fluoropolymer resin. For Capillary Columns.
Agilent 0100-1379 Agilent Straight Ferrules 1/16 in. VG-2 Vespel, 40% graphite. For Capillary Columns.
Agilent 0100-1381 Agilent Reducing Ferrules 1/16 in. to 0.4 mm VG-2 Vespel, 40% graphite. For Capillary Columns.
Agilent 0100-1383 Agilent Ferrule, reducing 1/16in-0.8mm Vespel 10/pk Ferrule, reducing 1/16in-0.8mm Vespel 10/pk.
Agilent 0100-1389 Agilent On-Column Syringes Replacement fluoropolymer resin ferrule for HP Part Number 9301-0658. Ideal for manual on-column injections. Depending on column diameter, choose either fused silica or durable stainless steel.
Agilent 0100-1443 Agilent HP 59980B Particle Beam Supplies Capillary ferrule. LC/MS Supplies.
Agilent 0100-1490 Agilent Ferrule, front/back 1/16in SS Ferrule, front/back 1/16in SS.
Agilent 0100-1511 Agilent GC Valves and Loops Compatible with HP 5890/6890 Parts for Interfacing Capillary Columns to W Series Valves. 1/16 in. stainless steel counterbored nut. For use with above liners.
Agilent 0100-1512 Agilent GC Valves and Loops Compatible with HP 5890/6890 Parts for Interfacing Capillary Columns to W Series Valves. Polyimide 1/16 in. ferrule.
Agilent 0100-1513 Agilent GC Valves and Loops Compatible with HP 5890/6890 Parts for Interfacing Capillary Columns to W Series Valves. Polyimide liner for 530 um columns.
Agilent 0100-1514 Agilent GC Valves and Loops Compatible with HP 5890/6890 Parts for Interfacing Capillary Columns to W Series Valves. Polyimide liner for 320 um columns.
Agilent 0100-1515 Agilent GC Valves and Loops Compatible with HP 5890/6890 Parts for Interfacing Capillary Columns to W Series Valves. Stainless Steel bulkhead ZDV union. For interfacing 530 pm columns with 1/16 in. transfer line.
Agilent 0100-1527 Agilent GC Valves and Loops Compatible with HP 5890/6890 Parts for Interfacing Capillary Columns to W Series Valves. Stainless Steel bulkhead ZDV union. For interfacing 320 um columns with 1/16 in. transfer line.
Agilent 0100-1619 Agilent Zero Dead-Volume Union, U-435 Stainless steel. 0.25mm thru-hole. Used to connect fused silica tubing.
Agilent 0101-0030 Agilent Flowmeter, soap film 10ml For use with Snoop soap solution 9300-0311.
Agilent 0101-0300 Agilent GC Valves and Loops Compatible with HP 5890/6890 2.00 cc Loop.
Agilent 0101-0301 Agilent GC Valves and Loops Compatible with HP 5890/6890 5.00 cc Loop.
Agilent 0101-0302 Agilent GC Valves and Loops Compatible with HP 5890/6890 10.00 cc Loop.
Agilent 0101-0355 Agilent GC Valves and Loops Compatible with HP 5890/6890 Valve-Related Parts. Metering valve. For LSVs as a sample-out restrictor or as a flow-balancer for 10-100 ml/min.
Agilent 0101-0403 Agilent GC Valves and Loops Compatible with HP 5890/6890 Valve-Related Parts. Angle metering valve, 1/8 in. stainless steel.
Agilent 0101-0460 Agilent Valve, 6-port 300C max Includes 1/16in. SS fittings and ferrules.
Agilent 0101-0532 Agilent In-line filter assembly, 7um For use with GC effluent splitters. Replacement filter: 3150-0404.
Agilent 0101-0584 Agilent GC Valves and Loops Compatible with HP 5890/6890 General-Purpose Valves. Gas sampling. 6 port replacement valve WE series, 300 psi, 350[degree]C.
Agilent 0101-0585 Agilent GC Valves and Loops Compatible with HP 5890/6890 General-Purpose Valves. Gas sampling. 10 port replacement valve WE series, 300 psi, 350[degree]C.
Agilent 0101-0594 Agilent Capillary Splitters Fixed outlet splitter for capillary columns (not for use with 0.53 mm). 1:1 ratio splitter. Tubing ID: 0.220 mm to 0.220 mm.
Agilent 0101-0595 Agilent Capillary Splitters Fixed outlet splitter for capillary columns (not for use with 0.53 mm). 1:10 ratio splitter. Tubing ID: 0.210 mm to 0.110 mm.
Agilent 0101-0633 Agilent GC Valves and Loops Compatible with HP 5890/6890 Valve-Related Parts. Micrometering valve. For flow balancing gas flows of 2-50 ml/min.
Agilent 0101-0636 Agilent GC Valves and Loops Compatible with HP 5890/6890 Liquid sampling. 0.2 ul replacement valve UWP series, 1,000 psi, 75[degree]C.
Agilent 0101-0637 Agilent GC Valves and Loops Compatible with HP 5890/6890 Liquid sampling. 0.5 ul replacement valve UWP series, 1,000 psi, 75[degree]C.
Agilent 0101-0638 Agilent GC Valves and Loops Compatible with HP 5890/6890 Liquid sampling. 1.0 ul replacement valve UWP series, 1,000 psi, 75[degree]C.
Agilent 0101-0639 Agilent GC Valves and Loops Compatible with HP 5890/6890 Liquid sampling. 0.5 ul replacement valve UW series, 5,000 psi, 75[degree]C.
Agilent 0101-1398 Agilent Regulator for Helium Gas He Gas for ICP-MS reaction gas.
Agilent 0101-1399 Agilent Regulator for Hydrogen Gas H2 Gas for ICP-MS reaction gas.
Agilent 0101-1400 Agilent Regulator for Argon Gas Argon Gas for ICP-MS
Agilent 01040-87602 Agilent Parts and Supplies for HP 1037/40/46/47/49 Detectors Parts for HP 1037/47A Refractive Index Detector. Inlet capillary, 880 mm x 0.12 mm id, rigid.
Agilent 01078-87305 Agilent Capillary Tubing (stainless steel), with Swagelok fittings Length: 800 mm.
Agilent 01078-87306 Agilent Capillary Tubing (stainless steel), with Swagelok fittings Length: 700 mm.
Agilent 01090-22404 Agilent Fluoropolymer resin tubing screw with barb fitting For use with 1090 bottle head assembly and fluoropolymer resin Helium tubing.
Agilent 03394-20500 Agilent Paper and Supplies for HP 3397A, HP 3396 Series III, and HP 3396A/B/95/94 Replacement paper roll rod.
Agilent 03394-60540 Agilent Cables to Connect any HP 3394/95A and 3396A/B Integrator General Purpose cable. Remote.
Agilent 03394-60560 Agilent Cables to Connect any HP 3394/95A and 3396A/B Integrator HP 5890 GC cable. Remote.
Agilent 03394-60600 Agilent Cables from HP Integrators to HP 1046A Fluorescence Detector Remote. Remote Start/Stop Cable from HP 1100 series to HP 3396(A) & 3396(B) Series II Integrator.
Agilent 03396-60560 Agilent Cables from HP Integrators to HP 1050, 1090 Series Sample No. BCD Cables from HP 1100 Series to HP 3396 integrator.
Agilent 03396-60650 Agilent Cables from HP Integrators to HP 1090, 1040 Series Remote.
Agilent 03396-61010 Agilent Cables to Connect any HP 3394/95A and 3396A/B Integrator HP 6890 Series GC cable. Remote.
Agilent 03396-61020 Agilent Analog signal cable, 6890 to integrator Pins 15m/9m.
Agilent 0460-0186 Agilent HP 7694 Headspace Analysis Supplies HP 19395A Miscellaneous. Thermosetting tape.
Agilent 0460-1266 Agilent Fluoropolymer resin Tape Roll of fluoropolymer resin tape.
Agilent 0515-1446 Agilent Set Screw For MSD ion source.
Agilent 05890-61090 Agilent GC Valves and Loops Compatible with HP 5890/6890 Valve-Related Parts. Solenoid valve for controlling actuator.
Agilent 05890-61260 Agilent Chemical Filters/Traps Chemical filter for HP 5890 internal.
Agilent 05921-21170 Agilent Ferrules and Nuts for Capillary Columns Column nut for two-hole ferrules, 1/16 in. These ferrules are recommended for use with GC inlets and FID, NPD and ECD. The 100% Vespel ferrule can be used for most applications and will emerge from the fitting in reusable condition time and again.
Agilent 05921-21850 Agilent HP 5921/G2350A Atomic Emission Detector Supplies Ferrule nut. Environmental laboratories are using the Atomic Emission Detector (AED) to make GC analysis of unknowns faster and more accurate.
Agilent 05921-21860 Agilent HP 5921/G2350A Atomic Emission Detector Supplies Ferrule key. Environmental laboratories are using the Atomic Emission Detector (AED) to make GC analysis of unknowns faster and more accurate.
Agilent 05921-61090 Agilent HP 5921/G2350A Atomic Emission Detector Supplies Discharge Tube. Environmental laboratories are using the Atomic Emission Detector (AED) to make GC analysis of unknowns faster and more accurate.
Agilent 05921-61095 Agilent AED Sapphire discharge tube kit Includes sapphire (aluminum oxide) discharge tube, ferrule, and o-ring. While this discharge tube may perform similarly to a fused silica tube, performance may be application dependent (ie.
Agilent 05921-80350 Agilent HP 5921/G2350A Atomic Emission Detector Supplies Spectrometer window-cleaned. Environmental laboratories are using the Atomic Emission Detector (AED) to make GC analysis of unknowns faster and more accurate.
Agilent 05930-20458 Agilent HP 5985/87/88 Parts and Supplies Plunger Support insulator. Ion Source Parts and Supplies.
Agilent 05970-60045 Agilent Qualitative Standards Qualitative MS Standards. Samples for GC/MS Systems. HP 5970 Performances Evaluation Sample Contains 6 vials: 4 vials (10 ng/ul), 1 vial (100 pg/ul), and 1 vial (100 ng/ul) each of dodecane biphenyl, p-chlorodiphenyl, and metnyl palmitate in isooctane, 1 ml ampoule.
Agilent 05970-80102 Agilent Electron Multiplier Life expectancy: 9 to 12 months.
Agilent 05971-20134 Agilent Drawout Plate For MSD Ion Source.
Agilent 05971-20143 Agilent Ion Focus Lens For MSD Ion Source.
Agilent 05971-40100 Agilent HP GCD/5971/72 MSD Parts and Supplies Baseplate/manifold seal (HP 5971). Miscellaneous Parts and Supplies.
Agilent 05971-60140 Agilent HP GCD/5971/72 MSD Parts and Supplies Filament assembly (HP GCD/5971). Miscellaneous Parts and Supplies.
Agilent 05971-60170 Agilent Repeller assembly for the 5971/72/GCD
Agilent 05971-60561 Agilent HP GCD/5971/72 MSD Parts and Supplies MSD Tool Kit. MSD Tool Kit includes: Small abrasive sticker, Large abrasive sticker, Small cleaning rod, Large cleaning rod, Source hold tool, Cotton swabs, Nylon gloves (1 pair), Abrasive sheet, 30 um (5/pk), Tool kit (wrenches, driving tools). Kits.
Agilent 05971-80101 Agilent Electron multiplier Electron multiplier.
Agilent 05971-80102 Agilent General GC/MS Supplies and Electron Multipliers Electron Multiplier for the 5971/72/73. Electron Multipliers and Replacement Horns.
Agilent 05971-80103 Agilent General GC/MS Supplies and Electron Multipliers Electron Multiplier Replacement Horn. For use with 5970/71/72/73 and 5989 multipliers. Electron Multipliers and Replacement Horns.
Agilent 05980-20018 Agilent General GC/MS Supplies and Electron Multipliers PFTBA glass bulb. Cleaning and Maintenance Supplies.
Agilent 05980-60051 Agilent Lens cleaning paper, lint free UV/VIS. Cell Accessories.
Agilent 05985-60179 Agilent HP 5985/87/88 Parts and Supplies Welded filament assembly. Direct Insertion Probe (DIP).
Agilent 05985-60180 Agilent General GC/MS Supplies and Electron Multipliers Electron Multiplier, 4-lead Type, (negative ions only). For use with 5985/87/88. Electron Multipliers and Replacement Horns.
Agilent 05988-20066 Agilent Column Nut For ion source. Nut for Capillary Columns. MS interface column nut for GC/MS.
Agilent 05989-20109 Agilent HP 5989 MS Engine Parts and Supplies Plate insulator, ion source. Ion Source Parts and Supplies.
Agilent 05989-20145 Agilent HP 5989 MS Engine Parts and Supplies EI/CI repeller. Ion Source Parts and Supplies.
Agilent 05989-20165 Agilent HP 5989 MS Engine Parts and Supplies Filament block. Ion Source Parts and Supplies.
Agilent 05989-80043 Agilent General GC/MS Supplies and Electron Multipliers Electron Multiplier for the 5989. Electron Multipliers and Replacement Horns.
Agilent 05990-60075 Agilent Tuning & System Perform Stand Tuning & System Perform Stand.
Agilent 05990-60084 Agilent HP 5970 MSD Parts and Supplies Filament assembly for ion source.
Agilent 07673-20570 Agilent HP Automatic Liquid Sampler Supplies Miscellaneous Autosampler Supplies. Screw for mounting syringe.
Agilent 07673-40180 Agilent HP Automatic Liquid Sampler Supplies Miscellaneous Autosampler Supplies. Diffusion caps for 4 ml vials.
Agilent 07673-60840 Agilent HP Automatic Liquid Sampler Supplies 7673 Basic Supply Kit. This kit contains: 10 ul syringes (6/ea), 23/26-gauge needles, 4 ml vials with diffusion caps (144/pk), 2 ml automatic sampler vials with screw caps (1,000/pk) GC septa (25/pk), Vial racks (5/pk).
Agilent 07673-61330 Agilent 250/320 needle support kit, septum nut For 7673 injector.
Agilent 07673-61340 Agilent Needle support kit, auto 320/250 For 7673 injector.
Agilent 07675-80050 Agilent GC Valves and Loops Compatible with HP 5890/6890 Tube, 1/16 in. with 1/8 in. bulkhead fitting, 520 mm long.
Agilent 07680-21550 Agilent Check valve seal Check valve seal.
Agilent 07680-21565 Agilent Sieve Holder
Agilent 07680-21670 Agilent SFE tubing, 1/16in. 124.5mm SS Tubing between nozzle and pre-nozzle filter.
Agilent 07680-60790 Agilent HP 7680 Supercritical Fluid Extractor Supplies Packed ODS trap assembly.
Agilent 07680-61350 Agilent HP 7680 Supercritical Fluid Extractor Supplies Packed Stainless steel balls trap assembly.
Agilent 07680-62105 Agilent HP 7680 Supercritical Fluid Extractor Ring frit assembly.
Agilent 07680-62130 Agilent HP 7680 Supercritical Fluid Extractor Supplies Packed Tenax trap assembly.
Agilent 07680-62140 Agilent HP 7680 Supercritical Fluid Extractor Supplies Packed Diol trap assembly.
Agilent 07680-62150 Agilent HP 7680 Supercritical Fluid Extractor Supplies Packed Cyano trap assembly.
Agilent 07680-62300 Agilent Trap Assembly Packed Florsil.
Agilent 08451-60104 Agilent HP 8452A Supplies Standard cell holder. UV/VIS. Spectrophotometer Supplies.
Agilent 08452-60104 Agilent HP 8452A Supplies Deuterium lamp assembly for HP 8452A and 8452A, option 002. UV/VIS. Spectrophotometer Supplies.
Agilent 08452-60121 Agilent HP 8452A Supplies Tungsten lamp assembly for HP 8452A, NIR version. UV/VIS. Installation Kit for HP 5890 without Gas Purifier System.
Agilent 0854-0141 Agilent HP 5890 Detector Supplies FPD Supplies. Glow plug.
Agilent 0890-1761 Agilent HP 1049 Electrochemical Detector Parts and Supplies PEEK tubing, 1/16 in. od, 0.5 mm id. 1.5 m length, orange.
Agilent 0890-1762 Agilent PEEK Tubing and Fittings 1.5 m PEEK Tubing (without fittings). ID: 0.25 mm. OD: 1/16 in.
Agilent 0890-1763 Agilent PEEK Tubing and Fittings 1.5 m PEEK Tubing (without fittings). ID: 0.18 mm. OD: 1/16 in.
Agilent 0890-1893 Agilent Sleeve for 375u od fused silica tubing Sleeve for 375u od fused silica tubing.
Agilent 0890-1901 Agilent HP 59987 ElectroSpray Interface Supplies PEEK tubing,.0025 in. id. LC/MS Supplies.
Agilent 0890-1915 Agilent PEEK Tubing and Fittings 1.5 m PEEK Tubing (without fittings). ID: 0.13 mm. OD: 1/16 in.
Agilent 0890-1921 Agilent HP 59987 ElectroSpray Interface Supplies PEEK tubing,.03 in. id. LC/MS Supplies.
Agilent 0905-0103 Agilent O-Rings Miscellaneous O-rings. 0.237 in. id, 0.103 in. cd, Viton. CD = CROSS DIAMETER. Used with actuator valve.
Agilent 0905-0464 Agilent O-Rings Miscellaneous O-rings. 0.563 in. id, 0.062 in. cd, Monel. CD = CROSS DIAMETER. Used with HP 5700 ECD and HP 5830/40A.
Agilent 0905-0466 Agilent Copper Gasket 15.2cm (6").
Agilent 0905-0820 Agilent HP 5985/87/88 Parts and Supplies Radial seals for 1/2 in. DIP inlet with spring. Direct Insertion Probe (DIP).
Agilent 0905-0938 Agilent HP 5995 Parts and Supplies Sealing ring, open-split. Sample Introduction Parts for Capillary Columns.
Agilent 0905-0970 Agilent HP 1090 Pump and Flow Path Supplies Waste sleeve: O-ring, 4 mm id, 4.8 mm od.
Agilent 0905-0989 Agilent Piston seal, 1090, 1/pk Graphitized fluoropolymer resin.
Agilent 0905-1145 Agilent O-ring, Viton 12/pk O-ring, Viton 12/pk.
Agilent 0905-1159 Agilent HP 5921/G2350A Atomic Emission Detector Supplies HP 5921/G2350A Common Parts. GC chamber O-ring. Environmental laboratories are using the Atomic Emission Detector (AED) to make GC analysis of unknowns faster and more accurate.
Agilent 0905-1175 Agilent 79851A/52 Pump Module Parts and Supplies Wash seal. HP 1050 Pump.
Agilent 0905-1189 Agilent HP 5989 MS Engine Parts and Supplies O-ring manifold window. Miscellaneous Parts and Supplies.
Agilent 0905-1194 Agilent HP 1090 Pump and Flow Path Supplies Pump seal, orange (use for buffered solutions).
Agilent 0905-1199 Agilent HP 1050 TI Pump Pump Module Parts and Supplies. Piston seal.
Agilent 0905-1245 Agilent HP 7686 Solution Phase Synthesizer Supplies O-ring. Compatible with HP PrepStation.
Agilent 0905-1259 Agilent HP 1090 Pump and Flow Path Supplies Kalrez O-ring, for solvent reservoir.
Agilent 0905-1294 Agilent Metering Valve Seal For Agilent 1100 Standard Autosampler Metering Device. 900uL.
Agilent 0905-1420 Agilent 79851A/52 Pump Module Parts and Supplies Pump seal, polyethylene (for Normal Phase (Hexane) applications). HP 1050 Pump.
Agilent 0905-1516 Agilent Viton O-Ring For G1361A 1100 Series Preparative Pump. 30mm.
Agilent 0905-1608 Agilent O-ring, Perfluoroelastomer 7.6 mm id, 1.8 mm thick, white.
Agilent 0905-1609 Agilent O-ring, Perfluoroelastomer 1.1 mm id, 1.3 mm thick, white.
Agilent 0905-1610 Agilent O-ring, Perfluoroelastomer 6.1 mm id, 1.8 mm thick, white.
Agilent 0960-0376 Agilent General GC/MS Supplies and Electron Multipliers Gauge tube for measuring vacuum. Cleaning and Maintenance Supplies.
Agilent 0960-0799 Agilent HP 5989 MS Engine Parts and Supplies Ion gauge tube, K-25 flange. Miscellaneous Parts and Supplies.
Agilent 1000-0488 Agilent 79854A Multiple Wavelength Detector (MWD)/G1306A Diode-Array Detector (DAD) Parts and Supplies Window, Quartz. HP 1050 TI Detector.
Agilent 1000-0544 Agilent Macro Cells - with PTFE lid The macro cell which is defined by DIN 58963 as a rectangular cell with an inner width above 5 mm, has emerged as the standard for photometry. The most widely used macro cell is a rectangular cell with outer dimensions of 45 x 12.5 mm (height x width).
Agilent 1000-0822 Agilent Filter, 370nm cut off Filter, 370nm cut off.
Agilent 1000-0953 Agilent Quartz Window For high pressure flow cell. Conical. 7985/A MWD (multiple wavelength detector)/G1306A DAD (diode-array detector) replacement item.
Agilent 10833B-2310 Agilent HPIB Cable 2m.
Agilent 10834A-2310 Agilent Adapter Extends GPIB connector.
Agilent 112-2032 Agilent Column, Carbowax 20M, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.25. Temperature Limits (oC): 60 to 220/240.
Agilent 112-2112 Agilent Column, CAM, 0.25mm I.D. x 15m Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.25. Temperature Limits (oC): 60 to 220/240, Unlike DB-WAX, CAM, Carbowax 20M and OV-351 GC columns are not bonded and cross-linked, therefore J&W does not recommend solvent rinsing.
Agilent 112-2132 Agilent Column, CAM, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.25. Temperature Limits (oC): 60 to 220/240, Unlike DB-WAX, CAM, Carbowax 20M and OV-351 GC columns are not bonded and cross-linked, therefore J&W does not recommend solvent rinsing.
Agilent 112-2132E Agilent GC Column, DB-FFAP 30m, 0.32mm, 0.50um, 5in cage
Agilent 112-2133 Agilent CAM Stabilwax-DB; carbowax amine. Base deactivated polyethlene glycol specifically designed for amine analysis. 0.25mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: 60 to 220[degree]C.
Agilent 112-2162 Agilent Column, CAM, 0.25mm I.D. x 60m Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.25. Temperature Limits (oC): 60 to 220/240, Unlike DB-WAX, CAM, Carbowax 20M and OV-351 GC columns are not bonded and cross-linked, therefore J&W does not recommend solvent rinsing.
Agilent 112-2532 Agilent Cyclodex-B* GC Column For separating chiral compounds. Allows separation at temperatures below the melting point of cyclodextrin. Phase composition: non-bonded proprietary phase using permethylated beta-cyclodextrin. Temperature range: 10 to 230[degree]C. ID: 0.25mm. Length: 30m. Thickness: 0.25um.
Agilent 112-2532E Agilent GC Column, DB-23 30m, 0.32mm, 0.25um, 5in cage
Agilent 112-2562 Agilent Cyclodex-B LIPODEX C. 10.5% Beta-Cyclodextrin in DB-1701. Chiral separations without chiral specific derivatization. Broad range of resolving potential. 0.25mm ID. Length: 6000mm. Film: 0.25um. Temperature Range: 50 to 230[degree]C.
Agilent 112-5432 Agilent Column, SE-54, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.25. Temperature Limits (oC): 0 to 325/350.
Agilent 112-5462 Agilent SE-54 GC Column (5%-phenyl)(1% vinyl)-methylpolysiloxane. 0.25mm ID. Length: 6000mm. Film: 0.25um. Temperature Range: 0 to 325[degree]C.
Agilent 112-6632 Agilent Column, CycloSil-B, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.25. Temperature Limits (oC): 35 to 260/280, Similar Phases: LIPODEX C, Rt-betaDEXm, beta-DEX 110, beta-DEX 120.
Agilent 112-8837E Agilent GC Column, DB-XLB 30m, 0.25mm, 0.50um, 5in cage
Agilent 112-8867E Agilent GC Column, HP-INNOWax 50m, 0.20mm, 0.4um, 5in cage
Agilent 112-88A7 Agilent HP-88 100m x 0.25mm ID, 0.2um.
Agilent 112-88A7E Agilent GC Column, ULTRA-2 50m, 0.20mm, 0.33um, 5in cage
Agilent 113-2032 Agilent Column, Carbowax 20M, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.25. Temperature Limits (oC): 60 to 220/240.
Agilent 113-2132 Agilent CAM GC Column Specifically designed for analysis of basic organic compounds, particularly primary amines, with minimal tailing. Phase composition: non-bonded base deactivated polyethylene glycol. Temperature range: 60 to 220[degree]C. ID: 0.32mm. Length: 30m. Film Thickness: 0.25um.
Agilent 113-2132E Agilent CAM HP-basic wax. Wound on 127mm cage. 0.32mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: 60 to 220[degree]C.
Agilent 113-2133 Agilent CAM Stabilwax-DB; carbowax amine. Base deactivated polyethlene glycol specifically designed for amine analysis. 0.32mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: 60 to 220[degree]C.
Agilent 113-2133E Agilent GC Column, DB-WAXETR 30m, 0.53mm, 1.00um, 5in cage
Agilent 113-2532 Agilent Cyclodex-B LIPODEX C. 10.5% Beta-Cyclodextrin in DB-1701. Chiral separations without chiral specific derivatization. Broad range of resolving potential. 0.32mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: 50 to 230[degree]C.
Agilent 113-2532E Agilent GC Column, DB-225MS 30m, 0.25mm, 0.25um, 5in cage
Agilent 113-3032 Agilent Column, SE-30, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.25. Temperature Limits (oC): 0 to 325/350.
Agilent 113-3112 Agilent Column, GS-CarbonPLOT, 0.32mm I.D. x 15m Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 1.50. Temperature Limits (oC): -60 to 350/360, Similar Phases: Carbopack, CLOT, Carboxen-1006 PLOT, CP-CarboPLOT P7.
Agilent 113-3132 Agilent Column, GS-CarbonPLOT, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 1.50. Temperature Limits (oC): -60 to 350/360, Similar Phases: Carbopack, CLOT, Carboxen-1006 PLOT, CP-CarboPLOT P7.
Agilent 113-3133 Agilent Column, GS-CarbonPLOT, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 3.00. Temperature Limits (oC): -60 to 350/360, Similar Phases: Carbopack, CLOT, Carboxen-1006 PLOT, CP-CarboPLOT P7.
Agilent 113-3162 Agilent Column, GS-CarbonPLOT, 0.32mm I.D. x 60m Inner Diameter (mm I.D.): 0.32. Length (meter): 60. Film Thickness (um): 1.50. Temperature Limits (oC): -60 to 350/360, Similar Phases: Carbopack, CLOT, Carboxen-1006 PLOT, CP-CarboPLOT P7.
Agilent 113-3432 Agilent GS-Q* GC Column Separates ethane, ethylene and ethyne (acetylene), and various other gases including Freons* and sulfides (except SO2). Replaces packed gas-solid columns. Phase composition: porous divinylbenzene homopolymer. Temperature range: -60 to 250[degree}C. I.D.: 0.32mm. Length: 30m.
Agilent 113-3432E Agilent GC Column, DB-FFAP 30m, 0.53mm, 1.00um, 5in cage
Agilent 113-4302 Agilent Column, GS-GasPro, 0.32mm I.D. x 5m Inner Diameter (mm I.D.): 0.32. Length (meter): 5. Film Thickness (um): N/A. Temperature Limits (oC): -80 to 260/300, Similar Phases: CP-Silica PLOT.
Agilent 113-4312 Agilent Column, GS-GasPro, 0.32mm I.D. x 15m Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): N/A. Temperature Limits (oC): -80 to 260/300, Similar Phases: CP-Silica PLOT.
Agilent 113-4332 Agilent Column, GS-GasPro, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): N/A. Temperature Limits (oC): -80 to 260/300, Similar Phases: CP-Silica PLOT.
Agilent 113-4362 Agilent Column, GS-GasPro, 0.32mm I.D. x 60m Inner Diameter (mm I.D.): 0.32. Length (meter): 60. Film Thickness (um): N/A. Temperature Limits (oC): -80 to 260/300, Similar Phases: CP-Silica PLOT.
Agilent 113-5432 Agilent SE-54 GC Column (5%-phenyl)(1% vinyl)-methylpolysiloxane. 0.32mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: 0 to 325[degree]C.
Agilent 113-6632 Agilent Column, CycloSil-B, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.25. Temperature Limits (oC): 35 to 260/280, Similar Phases: LIPODEX C, Rt-betaDEXm, beta-DEX 110, beta-DEX 120.
Agilent 115-2132 Agilent CAM Stabilwax-DB; carbowax amine. Base deactivated polyethlene glycol specifically designed for amine analysis. 0.53mm ID. Length: 3000mm. Film: 1um. Temperature Range: 60 to 200[degree]C.
Agilent 115-3113 Agilent Column, GS-CarbonPLOT, 0.53mm I.D. x 15m Inner Diameter (mm I.D.): 0.53. Length (meter): 15. Film Thickness (um): 3.00. Temperature Limits (oC): -60 to 350/360, Similar Phases: Carbopack, CLOT, Carboxen-1006 PLOT, CP-CarboPLOT P7.
Agilent 115-3133 Agilent Column, GS-CarbonPLOT, 0.53mm I.D. x 30m Inner Diameter (mm I.D.): 0.53. Length (meter): 30. Film Thickness (um): 3.00. Temperature Limits (oC): -60 to 350/360, Similar Phases: Carbopack, CLOT, Carboxen-1006 PLOT, CP-CarboPLOT P7.
Agilent 115-3332 Agilent Column, GS-Alumina/KCl, 0.53mm I.D. x 30m Inner Diameter (mm I.D.): 0.53. Length (meter): 30. Film Thickness (um): N/A. Temperature Limits (oC): -60 to 200, Similar Phases: CP-Alumina/KCI, HP-PLOT Al2O3, Rt-Alumina.
Agilent 115-3352 Agilent Column, GS-Alumina/KCl, 0.53mm I.D. x 50m Inner Diameter (mm I.D.): 0.53. Length (meter): 50. Film Thickness (um): N/A. Temperature Limits (oC): up to 200, Similar Phases: CP-Alumina/KCI, HP-PLOT Al2O3, Rt-Alumina.
Agilent 115-3352E Agilent GS-ALUMINA/KC1 50m, 0.53mm, 5 in cage
Agilent 115-3412 Agilent GS-Q CP PoraPLOT Q. Porous divinylbenzene homopolymer. Separates ethane, ethylene, and ethyne. Useful in separating various gases including freons. Not recommended for quantification of polar compounds. 0.53mm ID. Length: 1500mm. Temperature Range: -60 to 250[degree]C.
Agilent 115-3422 Agilent GS-Q CP PoraPLOT Q. Porous divinylbenzene homopolymer. Separates ethane, ethylene, and ethyne. Useful in separating various gases including freons. Not recommended for quantification of polar compounds. 0.53m ID. Length: 2500mm. Temperature Range: -60 to 250[degree]C.
Agilent 115-3432E Agilent GS-Q CP PoraPLOT Q. Wound on 127mm cage. Porous divinylbenzene homopolymer. Separates ethane, ethylene, and ethyne. Useful in separating various gases including freons. Not recommended for quantification of polar compounds. 0.53mm ID. Length: 3000mm. Temperature Range: -60 to 250[degree]C.
Agilent 115-34H2 Agilent GS-Q CP PoraPLOT Q. Porous divinylbenzene homopolymer. Separates ethane, ethylene, and ethyne. Useful in separating various gases including freons. Not recommended for quantification of polar compounds. 0.53mm ID. Length: 1000mm. Temperature Range: -60 to 250[degree]C.
Agilent 115-34H2E Agilent GC Column, DB-5 10m, 0.10mm, 0.10um, 5in cage
Agilent 115-3532 Agilent Column, GS-Alumina, 0.53mm I.D. x 30m Inner Diameter (mm I.D.): 0.53. Length (meter): 30. Film Thickness (um): 30. Temperature Limits (oC): -60 to 200, Similar Phases: Al2O3/KCl, Al2O3/Na2SO4, Rt-Alumina PLOT, Alumina PLOT.
Agilent 115-3532E Agilent GC Column, DB-1HT 30m, 0.32mm, 0.10um, 5in cage
Agilent 115-3552 Agilent Column, GS-Alumina, 0.53mm I.D. x 50m Inner Diameter (mm I.D.): 0.53. Length (meter): 50. Film Thickness (um): 50. Temperature Limits (oC): -60 to 200, Similar Phases: Al2O3/KCl, Al2O3/Na2SO4, Rt-Alumina PLOT, Alumina PLOT.
Agilent 121-0122 Agilent Db-1Ms, 20M, 0.18Mm, 0.18Um
Agilent 121-0713 Agilent DB-1701 SPB-1701; CP-Sil 19 CB. (14%-Cyanopropyl-phenyl)-methylpolysiloxane. Low to mid polarity. Sovent rinsable. Bonded and cross-linked. 0.18mm ID. Length: 1000mm. Film: 0.4um. Temperature Range: -20 to 280[degree]C.
Agilent 121-0722 Agilent Db-1701, 20M, 0.18Mm, 0.18Um
Agilent 121-1012 Agilent Column, DB-1, 0.18mm I.D. x 10m Inner Diameter (mm I.D.): 0.18. Length (meter): 10. Film Thickness (um): 0.18. Temperature Limits (oC): -60 to 325/350.
Agilent 121-1012E Agilent GC Column, DB-1 10m, 0.18mm, 0.18um, 5in cage
Agilent 121-1013 Agilent Column, DB-1, 0.18mm I.D. x 10m Inner Diameter (mm I.D.): 0.18. Length (meter): 10. Film Thickness (um): 0.40. Temperature Limits (oC): -60 to 325/350.
Agilent 121-1013E Agilent GC Column, DB-1 10m, 0.18mm, 0.40um, 5in cage
Agilent 121-101A Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.18mm ID. Length: 1000mm. Film: 0.2um. Temperature Range: -60 to 325[degree]C.
Agilent 121-1022 Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.18mm ID. Length: 2000mm. Film: 0.18um. Temperature Range: -60 to 325[degree]C.
Agilent 121-1022E Agilent GC Column, DB-5 25m, 0.20mm, 0.33um, 5in cage
Agilent 121-1023 Agilent Column, DB-1, 0.18mm I.D. x 20m Inner Diameter (mm I.D.): 0.18. Length (meter): 20. Film Thickness (um): 0.40. Temperature Limits (oC): -60 to 325/350.
Agilent 121-1043 Agilent DB*-1 GC Column A nonpolar column for compounds with similar polarities and larger differences in boiling points. Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods 504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.18mm. Length 40m. Thickness 0.40um.
Agilent 121-1043E Agilent GC Column, DB-5 50m, 0.20mm, 0.33um, 5in cage
Agilent 121-1222 Agilent DB-XLB MDN-12. Exceptionally low bleed. Low polarity. Designed to inhibit column bleed at high temperatures. Excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.18mm ID. Length: 2000mm. Film: 0.18um. Temperature Range: 30 to 340[degree]C.
Agilent 121-1232 Agilent Column, DB-XLB, 0.18mm I.D. x 30m Inner Diameter (mm I.D.): 0.18. Length (meter): 30. Film Thickness (um): 0.18. Temperature Limits (oC): 30 to 340/360, Similar Phases: PE-XLB, MDN-12.
Agilent 121-1324 Agilent DB*-624 GC Column Intermediate polarity column for analysis of volatile priority pollutants. Specified in EPA method 524.2. Phase composition: bonded 6% cyanopropyl-phenyl, 94% dimethylpolysiloxane. Temperature range: -20 to 260[degree]C. I.D.:0.18mm. Length: 20m. Film Thickness: 1.00um.
Agilent 121-1324E Agilent GC Column, HP-FFAP 25m, 0.20mm, 0.33um, 5in cage
Agilent 121-1524 Agilent DB-VRX Handles extensive target list of volatiles. Run time: <30 minutes for optimum sample throughput. Low polarity. Bonded and cross-linked. Solvent rinsable. 0.18mm ID. Length: 2000mm. Film: 1um. Temperature Range: -10 to 260[degree]C.
Agilent 121-1544 Agilent GC Column
Agilent 121-1544E Agilent GC Column, HP-INNOWax 50m, 0.20mm, 0.2um, 5in cage
Agilent 121-1722 Agilent Column, DB-17, 0.18mm I.D. x 20m Inner Diameter (mm I.D.): 0.18. Length (meter): 20. Film Thickness (um): 0.18. Temperature Limits (oC): 40 to 280/300, Similar Phases: HP-17, RSL-300, Rtx-50, PE-17, CC-17, 007-17 (MPS-50), SP-2250, HP-50+, SPB-50, ZB-50.
Agilent 121-1723 Agilent Column, DB-17, 0.18mm I.D. x 20m Inner Diameter (mm I.D.): 0.18. Length (meter): 20. Film Thickness (um): 0.30. Temperature Limits (oC): 40 to 280/300, Similar Phases: HP-17, RSL-300, Rtx-50, PE-17, CC-17, 007-17 (MPS-50), SP-2250, HP-50+, SPB-50, ZB-50.
Agilent 121-2223 Agilent DB-225 SP-233; CP-Sil 43 CB. (50%-cyanopropylphenyl)-dimethylpolysiloxane. Mid/high polarity. Excellent for separations of cis- and trans-fatty acid methyl esters. Bonded and cross-linked. Solvent rinsable. 0.18mm ID. Length: 2000mm. Film: 0.2um. Temperature Range: 40 to 220[degree]C.
Agilent 121-2323 Agilent Column, DB-23, 0.18mm I.D. x 20m Inner Diameter (mm I.D.): 0.18. Length (meter): 20. Film Thickness (um): 0.20. Temperature Limits (oC): 40 to 250/260, Similar Phases: SP-2330, Rtx-2330, 007-23, AT-Silar, PE-23.
Agilent 121-3822 Agilent Db-35Ms, 20M, 0.18Mm, 0.18Um
Agilent 121-4722 Agilent Column, DB-17ms, 0.18mm I.D. x 20m Inner Diameter (mm I.D.): 0.18. Length (meter): 20. Film Thickness (um): 0.18. Temperature Limits (oC): 40 to 320/340, Similar Phases: HP-50+, Rtx-50, PE-17, 007-17, SP-2250, SPB-50, BPX-50, SPB-17.
Agilent 121-4722E Agilent GC Column, DB-5MS 20m, 0.18mm, 0.18um, 5in cage
Agilent 121-5012 Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.18mm ID. Length: 1000mm. Film: 0.18um. Temperature Range: 40 to 240[degree]C.
Agilent 121-5012E Agilent GC Column, DB-5 10m, 0.18mm, 0.18um, 5in cage
Agilent 121-5013 Agilent Column, DB-5, 0.18mm I.D. x 10m Inner Diameter (mm I.D.): 0.18. Length (meter): 10. Film Thickness (um): 0.40.
Agilent 121-5022 Agilent Column, DB-5, 0.18mm I.D. x 20m Inner Diameter (mm I.D.): 0.18. Length (meter): 20. Film Thickness (um): 0.18.
Agilent 121-5022E Agilent GC Column, DB-1 20m, 0.18mm, 0.18um, 5in cage
Agilent 121-5023 Agilent DB*-5 GC Column Nonpolar. Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95% methylpolysiloxane. Range -60 to 325/350[Degree]C. I.D. 0.18mm. Length 20m. Thickness 0.4um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680, 1625, 1653, 8081, 8141, 8270, 8280.
Agilent 121-5042 Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.18mm ID. Length: 4000mm. Film: 0.18um. Temperature Range: 40 to 240[degree]C.
Agilent 121-5522 Agilent DB*-5ms GC Column Nonpolar. MS certified. Improved signal-to-noise ratio for better sensitivity and mass spectral integrity with basic and acidic analytes. Composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Temperature range -60 to 325/350[degree]C. I.D. 0.18mm. Length 20m. Thickness 0.18um.
Agilent 121-5522E Agilent GC Column, DB-1 30m, 0.25mm, 0.10um, 5in cage
Agilent 121-5523 Agilent Db-5Ms, 20M, 0.18Mm, 0.36Um
Agilent 121-5542 Agilent Column, DB-5ms, 0.18mm I.D. x 40m Inner Diameter (mm I.D.): 0.18. Length (meter): 40. Film Thickness (um): 0.18. Temperature Limits (oC): -60 to 325/350, Similar Phases: Rtx-5MS, HP-5MS, PTE-5, CP Sil 8 CBms, BPX-5, RH-5ms, HP-5 Trace.
Agilent 121-5621 Agilent Db-5.625, 20M, 0.18Mm, 0.18Um
Agilent 121-6822 Agilent Db-608, 20M, 0.18Mm, 0.18Um
Agilent 121-7012 Agilent DB-WAX HP-20M. Polyethylene glycol. High polarity. Improves resolution of low boiling point analyses. Column-to-column reproducibility. Bonded and cross-linked. Solvent rinsable. 0.18mm ID. Length: 1000mm. Film: 0.18um. Temperature Range: 20 to 250[degree]C.
Agilent 121-7022 Agilent DB-WAX HP-20M. Polyethylene glycol. High polarity. Improves resolution of low boiling point analyses. Column-to-column reproducibility. Bonded and cross-linked. Solvent rinsable. 0.18mm ID. Length: 2000mm. Film: 0.18um. Temperature Range: 20 to 250[degree]C.
Agilent 121-7023 Agilent DB*-Wax GC Column High polarity column for analysis of solvents, aromatics, glycols, essential oils, flavors, fragrances and volatile fatty acids. Phase composition: cross linked/surface bonded polyethylene glycol. Range 20 to 240/250[degree]C. I.D. 0.18mm. Length 20m. Thickness 0.30um.
Agilent 121-7023E Agilent GC Column, DB-5 20m, 0.18mm, 0.18um, 5in cage
Agilent 121-7042 Agilent Db-Wax, 40M, 0.18Mm, 0.18Um
Agilent 121-7043 Agilent DB-WAX HP-20M. Polyethylene glycol. High polarity. Improves resolution of low boiling point analyses. Column-to-column reproducibility. Bonded and cross-linked. Solvent rinsable. 0.18mm ID. Length: 4000mm. Film: 0.30um. Temperature Range: 20 to 250[degree]C.
Agilent 122-0112E Agilent GC Column, GS-Q 10m, 0.53mm, 5in cage
Agilent 122-0132E Agilent GC Column, DB-210 30m, 0.32mm, 0.50um, 5in cage
Agilent 122-0212 Agilent Column, DB-210, 0.25mm I.D. x 15m Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.25. Temperature Limits (oC): 45 to 240/260, Similar Phases: RSL-400, SP-2401, Rtx-200.
Agilent 122-0232 Agilent Column, DB-210, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.25. Temperature Limits (oC): 45 to 240/260, Similar Phases: RSL-400, SP-2401, Rtx-200.
Agilent 122-0232E Agilent GC Column, DB-WAX 20m, 0.10mm, 0.20um, 5in cage
Agilent 122-0233 Agilent Column, DB-210, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.50. Temperature Limits (oC): 45 to 240/260, Similar Phases: RSL-400, SP-2401, Rtx-200.
Agilent 122-0712 Agilent Column, DB-1701, 0.25mm I.D. x 15m Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.25. Temperature Limits (oC): -20 to 280/300, Similar Phases to DB-1701: SPB-1701, CP-Sil 19CB, Rtx-1701, BP-10, CB-1701, OV-1701, PE-1701, 007-1701, ZB-1701, RH-1701.
Agilent 122-0713 Agilent DB-1701 SPB-1701; CP-Sil 19 CB. (14%-Cyanopropyl-phenyl)-methylpolysiloxane. Low to mid polarity. Sovent rinsable. Bonded and cross-linked. 0.25mm ID. Length: 1500mm. Film: 1um. Temperature Range: -20 to 280[degree]C.
Agilent 122-0731 Agilent Column, DB-1701, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.15. Temperature Limits (oC): -20 to 280/300, Similar Phases to DB-1701: SPB-1701, CP-Sil 19CB, Rtx-1701, BP-10, CB-1701, OV-1701, PE-1701, 007-1701, ZB-1701, RH-1701.
Agilent 122-0732 Agilent DB*-1701 GC Column Low-to-mid polarity column with a dipole moment. Phase composition: bonded 14% cyanopropylphenyl, 86% dimethylpolysiloxane. Temperature range: -20 to 280/300[degree]C. I.D.: 0.25mm. Length: 30m. Film Thickness: 0.25um. For EPA methods 507, 508, 515, 515.2, 552, 552.1, and 8081.
Agilent 122-0732E Agilent GC Column
Agilent 122-0733 Agilent DB*-1701 GC Column Low-to-mid polarity column with a dipole moment. Phase composition: bonded 14% cyanopropylphenyl, 86% dimethylpolysiloxane. Temperature range: -20 to 280/300[degree]C. I.D.: 0.25mm. Length: 30m. Film Thickness: 1.00um. For EPA methods 507, 508, 515, 515.2, 552, 552.1, and 8081.
Agilent 122-0733E Agilent GC Column, DB-FFAP 30m, 0.25mm, 0.25um, 5in cage
Agilent 122-0761 Agilent Column, DB-1701, 0.25mm I.D. x 60m Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.15. Temperature Limits (oC): -20 to 280/300, Similar Phases to DB-1701: SPB-1701, CP-Sil 19CB, Rtx-1701, BP-10, CB-1701, OV-1701, PE-1701, 007-1701, ZB-1701, RH-1701.
Agilent 122-0762 Agilent Column, DB-1701, 0.25mm I.D. x 60m Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.25. Temperature Limits (oC): -20 to 280/300, Similar Phases to DB-1701: SPB-1701, CP-Sil 19CB, Rtx-1701, BP-10, CB-1701, OV-1701, PE-1701, 007-1701, ZB-1701, RH-1701.
Agilent 122-0763 Agilent Column, DB-1701, 0.25mm I.D. x 60m Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 1.00. Temperature Limits (oC): -20 to 280/300, Similar Phases to DB-1701: SPB-1701, CP-Sil 19CB, Rtx-1701, BP-10, CB-1701, OV-1701, PE-1701, 007-1701, ZB-1701, RH-1701.
Agilent 122-0763E Agilent GC Column, DB-1701 50m, 0.32mm, 1.00um, 5in cage
Agilent 122-0766 Agilent DB-1701 SPB-1701; CP-Sil 19 CB. (14%-Cyanopropyl-phenyl)-methylpolysiloxane. Low to mid polarity. Sovent rinsable. Bonded and cross-linked. 0.25mm ID. Length: 6000mm. Film: 0.5um. Temperature Range: -20 to 280[degree]C.
Agilent 122-1011 Agilent Column, DB-1, 0.25mm I.D. x 15m Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.10. Temperature Limits (oC): -60 to 325/350.
Agilent 122-1012 Agilent DB*-1 GC Column A nonpolar column for compounds with similar polarities and larger differences in boiling points. Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods 504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID: 0.25mm. Length: 15m. Thickness 0.25um.
Agilent 122-1012E Agilent GC Column, DB-1 15m, 0.25mm, 0.25um, 5in cage
Agilent 122-1013 Agilent Column, DB-1, 0.25mm I.D. x 15m Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 1.00. Temperature Limits (oC): -60 to 325/350.
Agilent 122-1013E Agilent GC Column, DB-1 15m, 0.25mm, 1.00um, 5in cage
Agilent 122-1022 Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 2500mm. Film: 0.25um. Temperature Range: -60 to 325[degree]C.
Agilent 122-1022E Agilent GC Column, DB-624 25m, 0.20mm, 1.12um, 5in cage
Agilent 122-1031 Agilent Column, DB-1, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.10. Temperature Limits (oC): -60 to 325/350.
Agilent 122-1031E Agilent GC Column, HP-20M 25m, 0.32mm, 0.30um, 5in cage
Agilent 122-1032 Agilent DB*-1 GC Column A nonpolar column for compounds with similar polarities and larger differences in boiling points. Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods 504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.25mm. Length 30m. Thickness 0.25um.
Agilent 122-1032E Agilent DB-1 HP-1; Ultra-1; SPB-1. Wound on 127mm cage. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: -60 to 325[degree]C.
Agilent 122-1032G Agilent DuraGuard GC Column Phase: DB-1. I.D.: 0.25mm. Length: 30m. Film thickness: 0.25um. Features a built-in length of deactivated fused silica tubing that eliminates problems with peak shape, installation hassles, and leaks associated with unions.
Agilent 122-1033 Agilent DB*-1 GC Column A nonpolar column for compounds with similar polarities and larger differences in boiling points. Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods 504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.25mm. Length 30m. Thickness 1.0um.
Agilent 122-1033E Agilent GC Column
Agilent 122-103E Agilent DB-1 HP-1; Ultra-1; SPB-1. Wound on 127mm cage. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: -60 to 325[degree]C.
Agilent 122-1052 Agilent DB-1 HP-1, Ultra-1, SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 5000mm. Film: 0.25um. Temperature Range: -60 to 325[degree]C.
Agilent 122-1061 Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 6000mm. Film: 0.1um. Temperature Range: -60 to 325[degree]C.
Agilent 122-1062 Agilent DB*-1 GC Column A nonpolar column for compounds with similar polarities and larger differences in boiling points. Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods 504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.25mm. Length 60m. Thickness 0.25um.
Agilent 122-1062E Agilent GC Column, HP-1, 50m, 0.32mm, 1.05um, 5in cage
Agilent 122-1063 Agilent DB*-1 GC Column A nonpolar column for compounds with similar polarities and larger differences in boiling points. Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods 504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.25mm. Length 60m. Thickness 1.00um.
Agilent 122-1063E Agilent GC Column, DB-WAXETR 50m, 0.32mm, 1.00um, 5in cage
Agilent 122-106E Agilent DB-1 HP-1; Ultra-1; SPB-1. Wound on 127mm cage. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 6000mm. Film: 0.5um. Temperature Range: -60 to 325[degree]C.
Agilent 122-106EE Agilent GC Column, HP-20M 50m, 0.32mm, 0.30um, 5in cage
Agilent 122-10A6 Agilent Column, DB-1, 0.25mm I.D. x 100m Inner Diameter (mm I.D.): 0.25. Length (meter): 100. Film Thickness (um): 0.50. Temperature Limits (oC): -60 to 325/350.
Agilent 122-10A6E Agilent DB-Petro Wound on 127mm cage. 0.25mm ID. Length: 10,000mm. Film: 0.5um. Temperature Range: -60 to 325[degree]C.
Agilent 122-10AE Agilent DB-1 HP-1; Ultra-1; SPB-1. Wound on 127mm cage. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 10,000mm. Film: 0.5um. Temperature Range: -60 to 325[degree]C.
Agilent 122-10G3 Agilent DuraGuard GC Column Phase: DB-1. I.D.: 0.25mm. Length: 150m. Film thickness: 1.00um. Features a built-in length of deactivated fused silica tubing that eliminates problems with peak shape, installation hassles, and leaks associated with unions.
Agilent 122-1111 Agilent Column, DB-1ht, 0.25mm I.D. x 15m Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.10. Temperature Limits (oC): -60 to 400, Similar Phases: PE-1ht.
Agilent 122-1111E Agilent GC Column, DB-1MS 15m, 0.25mm, 0.25um, 5in cage
Agilent 122-1131 Agilent Column, DB-1ht, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.10. Temperature Limits (oC): -60 to 400, Similar Phases: PE-1ht.
Agilent 122-1211 Agilent DB-XLB MDN-12. Exceptionally low bleed. Low polarity. Designed to inhibit column bleed at high temperatures. Excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 1500mm. Film: 0.1um. Temperature Range: 30 to 340[degree]C.
Agilent 122-1212 Agilent DB-XLB MDN-12. Exceptionally low bleed. Low polarity. Designed to inhibit column bleed at high temperatures. Excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 1500mm. Film: 0.25um. Temperature Range: 30 to 340[degree]C.
Agilent 122-1231 Agilent DB-XLB MDN-12. Exceptionally low bleed. Low polarity. Designed to inhibit column bleed at high temperatures. Excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 3000mm. Film: 0.1um. Temperature Range: 30 to 340[degree]C.
Agilent 122-1231E Agilent GC Column, HP-1MS 30m, 0.25mm, 1.0um, 5in cage
Agilent 122-1232 Agilent DB-XLB MDN-12. Exceptionally low bleed. Low polarity. Designed to inhibit column bleed at high temperatures. Excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: 30 to 340[degree]C.
Agilent 122-1232G Agilent DuraGuard GC Column Phase: DB-XLB. I.D.: 0.25mm. Length: 30m. Film thickness: 0.25um. Features a built-in length of deactivated fused silica tubing that eliminates problems with peak shape, installation hassles, and leaks associated with unions.
Agilent 122-1233 Agilent DB-XLB MDN-12. Exceptionally low bleed. Low polarity. Designed to inhibit column bleed at high temperatures. Excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 3000mm. Film: 1um. Temperature Range: 30 to 340[degree]C.
Agilent 122-1236 Agilent DB-XLB MDN-12. Exceptionally low bleed. Low polarity. Designed to inhibit column bleed at high temperatures. Excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: 30 to 340[degree]C.
Agilent 122-1262 Agilent Column, DB-XLB, 0.25mm I.D. x 60m Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.25. Temperature Limits (oC): 30 to 340/360, Similar Phases: PE-XLB, MDN-12.
Agilent 122-1262E Agilent GC Column, HP-5MS 60m, 0.25mm, 0.25um, 5in cage
Agilent 122-1332 Agilent DB-1301 Rtx-1301; PE-1301. (6%-cyanopropyl-phenyl) methylpolysiloxane. Low/midpolarity. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: -20 to 280[degree]C.
Agilent 122-1332E Agilent DB-1301 30m, 0.25mm, 0.25um, 5 inch cage
Agilent 122-1333 Agilent Column, DB-1301, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 1.00. Temperature Limits (oC): -20 to 280/300, Similar Phases to DB-1301: Rtx-1301, PE-1301, HP-1301.
Agilent 122-1333E Agilent GC Column, DB-1701 30m, 0.25mm, 1.00um, 5in cage
Agilent 122-1334 Agilent DB*-624 GC Column Intermediate polarity column for the analysis of volatile priority pollutants. Specified in EPA method 524.2. Phase composition: bonded 6% cyanopropyl-phenyl, 94% dimethylpolysiloxane. Temperature range: -20 to 260[degree]C. I.D.: 0.25mm. Length: 30m. Film Thickness: 1.40um.
Agilent 122-1334E Agilent GC Column
Agilent 122-1362 Agilent DB-1301 Rtx-1301; PE-1301. (6%-cyanopropyl-phenyl) methylpolysiloxane. Low/midpolarity. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 6000mm. Film: 0.25um. Temperature Range: -20 to 280[degree]C.
Agilent 122-1363 Agilent Column, DB-1301, 0.25mm I.D. x 60m Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 1.00. Temperature Limits (oC): -20 to 280/300, Similar Phases to DB-1301: Rtx-1301, PE-1301, HP-1301.
Agilent 122-1363E Agilent GC Column
Agilent 122-1364 Agilent Column, DB-624, 0.25 x 60m Diameter (mm I.D.): 0.25. Inner Length (meter): 60. Film Thickness (um): 1.40. Temperature Limits (oC): -20 to 260, Similar Phases: VOCOL, NON-PAKD, AT-624, Rtx-Volatiles, Rtx-502.2, PE-624, PE-502, 007-624, 007-502, HP-624, CP-624, ZB-624.
Agilent 122-1364E Agilent GC Column
Agilent 122-1534 Agilent DB*-VRX GC Column Low polarity. For optimum resolution of volatiles and separation of the following coeluting compounds while maintaining good peak shape: m- and p-xylene; and 1,1,2,2-tetrachloroethane and o-xylene. Temperature range: -20 to 260[degree]C. ID: 0.25mm. Length: 30m. Thickness: 1.40um.
Agilent 122-1564 Agilent DB*-VRX GC Column Low polarity. For optimum resolution of volatiles and separation of the following coeluting compounds while maintaining good peak shape: m- and p-xylene; and 1,1,2,2-tetrachloroethane and o-xylene. Temperature range: -20 to 260[degree]C. ID: 0.25mm. Length: 60m. Thickness: 1.40um.
Agilent 122-1564E Agilent DB-VRX Wound on 127mm cage. Handles extensive target list of volatiles. Run time: <30 minutes for optimum sample throughput. Low polarity. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 6000mm. Film: 1.4um. Temperature Range: -10 to 260[degree]C.
Agilent 122-1711 Agilent DB-17 HP-50+; Rtx-50. (50%-phenyl)-methylpolysiloxane. Midpolarity. Excellent for confirmational analyses. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 1500mm. Film: 0.15um. Temperature Range: 40 to 280[degree]C.
Agilent 122-1711E Agilent GC Column, DB-17 15m, 0.25mm, 0.15um, 5in cage
Agilent 122-1712 Agilent DB*-17 GC Column Intermediate polarity column. Use as a confirmation column for steroids, pesticides, herbicides, and drugs. Phase composition: bonded 50% diphenyl, 50% dimethylpolysiloxane. Temperature range: 40 to 280[degree]C. I.D.: 0.25mm. Length: 15m. Film Thickness: 0.25um.
Agilent 122-1713 Agilent DB-17 HP-50+; Rtx-50. (50%-phenyl)-methylpolysiloxane. Midpolarity. Excellent for confirmational analyses. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 1500mm. Film: 0.5um. Temperature Range: 40 to 280[degree]C.
Agilent 122-1713E Agilent GC Column, DB-17 15m, 0.25mm, 0.50um, 5in cage
Agilent 122-1731 Agilent Column, DB-17, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.15. Temperature Limits (oC): 40 to 280/300, Similar Phases: HP-17, RSL-300, Rtx-50, PE-17, CC-17, 007-17 (MPS-50), SP-2250, HP-50+, SPB-50, ZB-50.
Agilent 122-1731E Agilent GC Column, DB-17MS 20m, 0.18mm, 0.18um, 5in cage
Agilent 122-1732 Agilent DB*-17 GC Column Intermediate polarity column. Use as a confirmation column for steroids, pesticides, herbicides, and drugs. Phase composition: bonded 50% diphenyl, 50% dimethylpolysiloxane. Temperature range: 40 to 280[degree]C. I.D.: 0.25mm. Length: 30m. Film Thickness: 0.25um.
Agilent 122-1732E Agilent GC Column, DB-17 30m, 0.25mm, 0.15um, 5in cage
Agilent 122-1733 Agilent DB*-17 GC Column Intermediate polarity column. Use as a confirmation column for steroids, pesticides, herbicides, and drugs. Phase composition: bonded 50% diphenyl, 50% dimethylpolysiloxane. Temperature range: 40 to 280[degree]C. I.D.: 0.25mm. Length: 30m. Film Thickness: 0.50um.
Agilent 122-1762 Agilent Column, DB-17, 0.25mm I.D. x 60m Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.25. Temperature Limits (oC): 40 to 280/300, Similar Phases: HP-17, RSL-300, Rtx-50, PE-17, CC-17, 007-17 (MPS-50), SP-2250, HP-50+, SPB-50, ZB-50.
Agilent 122-1811 Agilent Column, DB-17ht, 0.25mm I.D. x 15m Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.15. Temperature Limits (oC): 40 to 340/365, Similar Phases: Rtx-65TG, PE-17ht.
Agilent 122-1831 Agilent Column, DB-17ht, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.15. Temperature Limits (oC): 40 to 340/365, Similar Phases: Rtx-65TG, PE-17ht.
Agilent 122-1932 Agilent Column, DB-35, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.25. Temperature Limits (oC): 40 to 300/320, Similar Phases: Rtx-35, SPB-35, AT-35, Sup-Herb, PE-35.
Agilent 122-1962 Agilent DB-35 Rtx-35; SPB-35. (35%-phenyl)-methylpolysiloxane. Midpolarity. Low bleed. Inert to active solutes. Ideal for confirmational analyses. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 6000mm. Film: 0.25um. Temperature Range: 40 to 300[degree]C.
Agilent 122-2032 Agilent Column, DB-200, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.25. Temperature Limits (oC): 30 to 300/320, Similar Phases: Rtx-200.
Agilent 122-2033 Agilent Column, DB-200, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.50. Temperature Limits (oC): 30 to 300/320, Similar Phases: Rtx-200.
Agilent 122-2212 Agilent Column, DB-225, 0.25mm I.D. x 15m Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.25. Temperature Limits (oC): 40 to 220/240, Similar Phases: HP-225, SP-2330, CP-Sil 43CB, RSL-500, Rtx-225, BP-225, CB-225, OV-225, PE-225, 007-225.
Agilent 122-2212E Agilent GC Column, DB-225, 15m, 0.25mm, 0.25um, 5in cage
Agilent 122-2231 Agilent Column, DB-225, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.15. Temperature Limits (oC): 40 to 220/240, Similar Phases: HP-225, SP-2330, CP-Sil 43CB, RSL-500, Rtx-225, BP-225, CB-225, OV-225, PE-225, 007-225.
Agilent 122-2232 Agilent Column, DB-225, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.25. Temperature Limits (oC): 40 to 220/240, Similar Phases: HP-225, SP-2330, CP-Sil 43CB, RSL-500, Rtx-225, BP-225, CB-225, OV-225, PE-225, 007-225.
Agilent 122-2312 Agilent Column, DB-23, 0.25mm I.D. x 15m Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.25. Temperature Limits (oC): 40 to 250/260, Similar Phases: SP-2330, Rtx-2330, 007-23, AT-Silar, PE-23.
Agilent 122-2312E Agilent GC Column, DB-23 15m, 0.25mm, 0.25um, 5in cage
Agilent 122-2331 Agilent Column, DB-23, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.15. Temperature Limits (oC): 40 to 250/260, Similar Phases: SP-2330, Rtx-2330, 007-23, AT-Silar, PE-23.
Agilent 122-2332 Agilent Column, DB-23, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.25. Temperature Limits (oC): 40 to 250/260, Similar Phases: SP-2330, Rtx-2330, 007-23, AT-Silar, PE-23.
Agilent 122-2332E Agilent GC Column, DB-WAXETR 30m, 0.25mm, 0.50um, 5in cage
Agilent 122-2361 Agilent Column, DB-23, 0.25mm I.D. x 60m Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.15. Temperature Limits (oC): 40 to 250/260, Similar Phases: SP-2330, Rtx-2330, 007-23, AT-Silar, PE-23.
Agilent 122-2361E Agilent GC Column, DB-WAX 60m, 0.25mm, 0.50um, 5in cage
Agilent 122-2362 Agilent Column, DB-23, 0.25mm I.D. x 60m Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.25. Temperature Limits (oC): 40 to 250/260, Similar Phases: SP-2330, Rtx-2330, 007-23, AT-Silar, PE-23.
Agilent 122-2362E Agilent GC Column, DB-WAXETR 60m, 0.25mm, 0.25um, 5in cage
Agilent 122-2461 Agilent DB-Dioxin SP-2331; Rtx-2332. Engineered for the analysis of polychlorinated dibenzodioxins and dibenzofurans. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 6000mm. Film: 0.15um. Temperature Range: 40 to 250[degree]C.
Agilent 122-2462 Agilent Column, DB-Dioxin, 0.25mm I.D. x 60m Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.25. Temperature Limits (oC): 40 to 250/270, Similar Phases:SP-2331, 007-23, Rtx-2332, CP Sil 88.
Agilent 122-2912 Agilent DB-225ms HP-225. Equivalent to (50%-cyanopropylphenyl)-dimethylpolysiloxane. Mid/high polarity. For separations of cis- and trans-fatty acid methyl esters. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 1500mm. Film: 0.25um. Temperature Range: 40 to 240[degree]C.
Agilent 122-2932 Agilent DB-225ms HP-225. Equivalent to (50%-cyanopropylphenyl)-dimethylpolysiloxane. Mid/high polarity. For separations of cis- and trans-fatty acid methyl esters. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: 40 to 240[degree]C.
Agilent 122-2932E Agilent GC Column, DB-XLB 30m, 0.25mm, 0.10um, 5in cage
Agilent 122-2962 Agilent DB-225ms HP-225. Equivalent to (50%-cyanopropylphenyl)-dimethylpolysiloxane. Mid/high polarity. For separations of cis- and trans-fatty acid methyl esters. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 6000mm. Film: 0.25um. Temperature Range: 40 to 240[degree]C.
Agilent 122-3212 Agilent DB-FFAP Stabilwax-DA, HP-FFAP. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 1500mm. Film: 0.25um. Temperature Range: 40 to 250[degree]C.
Agilent 122-3232 Agilent DB*-FFAP GC Column High polarity column for analysis of volatile fatty acids and phenols. Phase composition: cross-linked/surface bonded nitroterephthalic acid modified polyethylene glycol stationary phase. Temperature range: 40 to 250[degree]C. I.D.: 0.25mm. Length: 30m. Film Thickness: 0.25um.
Agilent 122-3232E Agilent GC Column, DB-23 30m, 0.25mm, 0.25um, 5in cage
Agilent 122-3233 Agilent DB-FFAP Stabilwax-DA, HP-FFAP. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: 40 to 250[degree]C.
Agilent 122-3262 Agilent DB-FFAP Stabilwax-DA, HP-FFAP. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 6000mm. Film: 0.25um. Temperature Range: 40 to 250[degree]C.
Agilent 122-3262E Agilent GC Column, HP-1, 60m, 0.25mm, 0.25um, 5in cage
Agilent 122-3263 Agilent DB-FFAP Stabilwax-DA, HP-FFAP. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 6000mm. Film: 0.5um. Temperature Range: 40 to 250[degree]C.
Agilent 122-3812 Agilent DB-35ms Rtx-35; SPB-35. Equivalent to (35%-phenyl)-methylpolysiloxane. Midpolarity. Low bleed, excellent inertness for active compounds. Ideal for confirmational analyses. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 1500mm. Film: 0.25um. Temperature Range: 50 to 340[degree]C.
Agilent 122-3831 Agilent DB-35ms Rtx-35; SPB-35. Equivalent to (35%-phenyl)-methylpolysiloxane. Midpolarity. Low bleed, excellent inertness for active compounds. Ideal for confirmational analyses. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 3000mm. Film: 0.15um. Temperature Range: 50 to 340[degree]C.
Agilent 122-3832 Agilent DB-35ms Rtx-35; SPB-35. Equivalent to (35%-phenyl)-methylpolysiloxane. Midpolarity. Low bleed, excellent inertness for active compounds. Ideal for confirmational analyses. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: 50 to 340[degree]C.
Agilent 122-3832E Agilent GC Column, DB-225 30m, 0.32mm, 0.25um, 5in cage
Agilent 122-3862 Agilent Column, DB-35ms, 0.25mm I.D. x 60m Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.25. Temperature Limits (oC): 50 to 340/360, Similar Phases: Rtx-35, SPB-35, AT-35, Sup-Herb, PE-35ms, MDN-35.
Agilent 122-4711 Agilent Column, DB-17ms, 0.25mm I.D. x 15m Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.15. Temperature Limits (oC): 40 to 320/340, Similar Phases: HP-50+, Rtx-50, PE-17, 007-17, SP-2250, SPB-50, BPX-50, SPB-17.
Agilent 122-4712 Agilent Column, DB-17ms, 0.25mm I.D. x 15m Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.25. Temperature Limits (oC): 40 to 320/340, Similar Phases: HP-50+, Rtx-50, PE-17, 007-17, SP-2250, SPB-50, BPX-50, SPB-17.
Agilent 122-4731 Agilent Column, DB-17ms, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.15. Temperature Limits (oC): 40 to 320/340, Similar Phases: HP-50+, Rtx-50, PE-17, 007-17, SP-2250, SPB-50, BPX-50, SPB-17.
Agilent 122-4732 Agilent Column, DB-17ms, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.25. Temperature Limits (oC): 40 to 320/340, Similar Phases: HP-50+, Rtx-50, PE-17, 007-17, SP-2250, SPB-50, BPX-50, SPB-17.
Agilent 122-4732E Agilent DB-17MS 30m, 0.25mm, 0.25um, 5 inch cage
Agilent 122-4762 Agilent Column, DB-17ms, 0.25mm I.D. x 60m Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.25. Temperature Limits (oC): 40 to 320/340, Similar Phases: HP-50+, Rtx-50, PE-17, 007-17, SP-2250, SPB-50, BPX-50, SPB-17.
Agilent 122-4762E Agilent GC Column, DB-5MS 60m, 0.25mm, 0.25um, 5in cage
Agilent 122-5011 Agilent DB*-5 GC Column Nonpolar. Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95% methylpolysiloxane. Range -60 to 325/350[Degree]C. I.D. 0.25mm. Length 15m. Thickness 0.10um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680, 1625, 1653, 8081, 8141, 8270, 8280.
Agilent 122-5012 Agilent DB*-5 GC Column Nonpolar. Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95% methylpolysiloxane. Range -60 to 325/350[Degree]C. I.D. 0.25mm. Length 15m. Thickness 0.25um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680, 1625, 1653, 8081, 8141, 8270, 8280.
Agilent 122-5012E Agilent GC Column, DB-5 15m, 0.25mm, 0.25um, 5in cage
Agilent 122-5013 Agilent Column, DB-5, 0.25mm I.D. x 15m Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 1.00.
Agilent 122-5013E Agilent GC Column, DB-5 15m, 0.25mm, 1.00um, 5in cage
Agilent 122-501E Agilent DB-5 HP-5; Ultra-2; SP-B-5. Wound on 127mm cage. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 1500mm. Film: 0.5um. Temperature Range: -60 to 325[degree]C.
Agilent 122-5022 Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 2500mm. Film: 0.25um. Temperature Range: -60 to 325[degree]C.
Agilent 122-5031 Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 3000mm. Film: 0.1um. Temperature Range: -60 to 325[degree]C.
Agilent 122-5032 Agilent DB*-5 GC Column Nonpolar. Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95% methylpolysiloxane. Range -60 to 325/350[Degree]C. I.D. 0.25mm. Length 30m. Thickness 0.25um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680, 1625, 1653, 8081, 8141, 8270, 8280.
Agilent 122-5032E Agilent DB-5 HP-5; Ultra-2; SP-B-5. Wound on 127mm cage. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: -60 to 325[degree]C.
Agilent 122-5033 Agilent DB*-5 GC Column Nonpolar. Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95% methylpolysiloxane. Range -60 to 325/350[Degree]C. I.D. 0.25mm. Length 30m. Thickness 1um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680, 1625, 1653, 8081, 8141, 8270, 8280.
Agilent 122-5033E Agilent GC Column, DB-17 30m, 0.25mm, 0.25um, 5in cage
Agilent 122-503E Agilent DB-5 HP-5; Ultra-2; SP-B-5. Wound on 127mm cage. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: -60 to 325[degree]C.
Agilent 122-5052 Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 5000mm. Film: 0.25um. Temperature Range: -60 to 325[degree]C.
Agilent 122-5061 Agilent Column, DB-5, 0.25mm I.D. x 60m Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.10.
Agilent 122-5062 Agilent DB*-5 GC Column Nonpolar. Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95% methylpolysiloxane. Range -60 to 325/350[Degree]C. I.D. 0.25mm. Length 60m. Thickness 0.25um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680, 1625, 1653, 8081, 8141, 8270, 8280.
Agilent 122-5062E Agilent GC Column, DB-1 60m, 0.25mm, 0.25um, 5in cage
Agilent 122-5063 Agilent DB*-5 GC Column Nonpolar. Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95% methylpolysiloxane. Range -60 to 325/350[Degree]C. I.D. 0.25mm. Length 60m. Thickness 1um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680, 1625, 1653, 8081, 8141, 8270, 8280.
Agilent 122-5063E Agilent GC Column, DB-1 60m, 0.25mm, 1.00um, 5in cage
Agilent 122-506E Agilent DB-5 HP-5; Ultra-2; SP-B-5. Wound on 127mm cage. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 6000mm. Film: 0.5um. Temperature Range: -60 to 325[degree]C.
Agilent 122-5511 Agilent Column, DB-5ms, 0.25mm I.D. x 15m Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.10. Temperature Limits (oC): -60 to 325/350, Similar Phases: Rtx-5MS, HP-5MS, PTE-5, CP Sil 8 CBms, BPX-5, RH-5ms, HP-5 Trace.
Agilent 122-5512 Agilent DB*-5ms GC Column Nonpolar. MS certified. Improved signal-to-noise ratio for better sensitivity and mass spectral integrity with basic and acidic analytes. Composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Temperature range -60 to 325/350[degree]C. I.D. 0.25mm. Length 15m. Thickness 0.25um.
Agilent 122-5512E Agilent DB-5MS 15m, 0.25mm, 0.25um, 5 inch cage
Agilent 122-5513 Agilent Column, DB-5ms, 0.25mm I.D. x 15m Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 1.00. Temperature Limits (oC): -60 to 325/350, Similar Phases: Rtx-5MS, HP-5MS, PTE-5, CP Sil 8 CBms, BPX-5, RH-5ms, HP-5 Trace.
Agilent 122-5516 Agilent DB-5ms Rtx-5ms; PTE-5. Phenyl Arylene polymer equivalent to (5%-phenyl)-methylpolysiloxane. Non-polar. Low bleed, excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 1500mm. Film: 0.5um. Temperature Range: -60 to 325[degree]C.
Agilent 122-5522 Agilent DB-5ms Rtx-5ms; PTE-5. Phenyl Arylene polymer equivalent to (5%-phenyl)-methylpolysiloxane. Non-polar. Low bleed, excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 2500mm. Film: 0.25um. Temperature Range: -60 to 325[degree]C.
Agilent 122-552A Agilent DB-5ms Rtx-5ms; PTE-5. Phenyl Arylene polymer equivalent to (5%-phenyl)-methylpolysiloxane. Non-polar. Low bleed, excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 2500mm. Film: 0.4um. Temperature Range: -60 to 325[degree]C.
Agilent 122-5531 Agilent Column, DB-5ms, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.10. Temperature Limits (oC): -60 to 325/350, Similar Phases: Rtx-5MS, HP-5MS, PTE-5, CP Sil 8 CBms, BPX-5, RH-5ms, HP-5 Trace.
Agilent 122-5532 Agilent DB*-5ms GC Column Nonpolar. MS certified. Improved signal-to-noise ratio for better sensitivity and mass spectral integrity with basic and acidic analytes. Composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Temperature range -60 to 325/350[degree]C. I.D. 0.25mm. Length 30m. Thickness 0.25um.
Agilent 122-5532E Agilent GC Column, DB-1MS 30m, 0.25mm, 0.25um, 5in cage
Agilent 122-5532G Agilent DuraGuard GC Column Phase: DB-5ms. I.D.: 0.25mm. Length: 30m. Film thickness: 0.25um. Features a built-in length of deactivated fused silica tubing that eliminates problems with peak shape, installation hassles, and leaks associated with unions.
Agilent 122-5533 Agilent DB*-5ms GC Column Nonpolar. MS certified. Improved signal-to-noise ratio for better sensitivity and mass spectral integrity with basic and acidic analytes. Composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Temperature range: -60 to 325/350[degree]C. I.D. 0.25mm. Length 30m. Thickness 1.00um.
Agilent 122-5533E Agilent GC Column
Agilent 122-5533G Agilent DuraGuard GC Column Phase: DB-5ms. I.D.: 0.25mm. Length: 30m. Film thickness: 1.00um. Features a built-in length of deactivated fused silica tubing that eliminates problems with peak shape, installation hassles, and leaks associated with unions.
Agilent 122-5536 Agilent DB*-5ms GC Column Nonpolar. MS certified. Improved signal-to-noise ratio for better sensitivity and mass spectral integrity with basic and acidic analytes. Composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Temperature range -60 to 325/350[degree]C. I.D. 0.25mm. Length 30m. Thickness 0.50um.
Agilent 122-5536E Agilent GC Column, DB-35MS 30m, 0.25mm, 0.25um, 5in cage
Agilent 122-5536G Agilent DuraGuard GC Column Phase: DB-5ms. I.D.: 0.25mm. Length: 30m. Film thickness: 0.50um. Features a built-in length of deactivated fused silica tubing that eliminates problems with peak shape, installation hassles, and leaks associated with unions.
Agilent 122-5552 Agilent DB-5ms Rtx-5ms; PTE-5. Phenyl Arylene polymer equivalent to (5%-phenyl)-methylpolysiloxane. Non-polar. Low bleed, excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 5000mm. Film: 0.25um. Temperature Range: -60 to 325[degree]C.
Agilent 122-5561 Agilent DB-5ms Rtx-5ms; PTE-5. Phenyl Arylene polymer equivalent to (5%-phenyl)-methylpolysiloxane. Non-polar. Low bleed, excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 6000mm. Film: 0.1um. Temperature Range: -60 to 325[degree]C.
Agilent 122-5562 Agilent DB*-5ms GC Column Nonpolar. MS certified. Improved signal-to-noise ratio for better sensitivity and mass spectral integrity with basic and acidic analytes. Composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Temperature range: -60 to 325/350[degree]C. I.D. 0.25mm. Length 60m. Thickness 0.25um.
Agilent 122-5562E Agilent GC Column, DB-1 60m, 0.53mm, 1.50um, 5in cage
Agilent 122-5562G Agilent DuraGuard GC Column Phase: DB-5ms. I.D.: 0.25mm. Length: 60m. Film thickness: 0.25um. Features a built-in length of deactivated fused silica tubing that eliminates problems with peak shape, installation hassles, and leaks associated with unions.
Agilent 122-5563 Agilent DB-5ms Rtx-5ms; PTE-5. Phenyl Arylene polymer equivalent to (5%-phenyl)-methylpolysiloxane. Non-polar. Low bleed, excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 6000mm. Film: 1um. Temperature Range: -60 to 325[degree]C.
Agilent 122-5631 Agilent DB*-5.625 GC Column Nonpolar, inert. For analyzing BNAs. Meet EPA semi-volatiles performance criteria for CLP protocols and EPA methods 625, 1625, and 8270. Bonded 5% phenyl, 95% methylpolysiloxane. Temperature range: -60 to 325/350[degree]C. I.D. 0.25mm. Length 30m. Thickness 0.25um.
Agilent 122-5632 Agilent DB*-5.625 GC Column Nonpolar, inert. For analyzing BNAs. Meet EPA semi-volatiles performance criteria for CLP protocols and EPA methods 625, 1625, and 8270. Bonded 5% phenyl, 95% methylpolysiloxane. Temperature range: -60 to 325/350[degree]C. I.D. 0.25mm. Length 30m. Thickness 0.50um.
Agilent 122-5633 Agilent DB*-5.625 GC Column Nonpolar, inert. For analyzing BNAs. Meet EPA semi-volatiles performance criteria for CLP protocols and EPA methods 625, 1625, and 8270. Bonded 5% phenyl, 95% methylpolysiloxane. Temperature range: -60 to 325/350[degree]C. I.D. 0.25mm. Length 30m. Thickness 1um.
Agilent 122-5661 Agilent DB-5.625 XTI-5. Equivalent to (5%-phenyl)-methylpolysiloxane. Non-polar. Processed to exhibit inertness for EPA Semivolatiles Methods 625, 1625, 8270 and CLP protocols. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 6000mm. Film: 0.25um. Temperature Range: -60 to 325[degree]C.
Agilent 122-5711 Agilent Column, DB-5ht, 0.25mm I.D. x 15m Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.10. Temperature Limits (oC): -60 to 400, Similar Phases: PE-5ht.
Agilent 122-5711E Agilent GC Column, DB-1HT 15m, 0.25mm, 0.10um, 5in cage
Agilent 122-5731 Agilent Column, DB-5ht, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.10. Temperature Limits (oC): -60 to 400, Similar Phases: PE-5ht.
Agilent 122-6432 Agilent DX-4 15% dimethylpolysiloxane - 85% polyethylene glycol. 0.25mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: 50 to 250[degree]C.
Agilent 122-6462 Agilent Column, DX-4, 0.25mm I.D. x 60m Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.25. Temperature Limits (oC): 50 to 250/270.
Agilent 122-6832 Agilent DB-608 SPB-608, NON-PAKD Pesticide. Designed for analysis of chlorinated pesticides and PCBs. Excellent inertness and recoveries without pesticide breakdown. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: 40 to 280[degree]C.
Agilent 122-7012 Agilent Column, DB-WAX, 0.25mm I.D. x 15m Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.25. Temperature Limits (oC): 20 to 250/260.
Agilent 122-7012E Agilent GC Column, DB-WAX 15m, 0.25mm, 0.25um, 5in cage
Agilent 122-7013 Agilent Column, DB-WAX, 0.25mm I.D. x 15m Inner Diameter (mm I.D.): 0.25. Length (meter): 15. Film Thickness (um): 0.50. Temperature Limits (oC): 20 to 240/250.
Agilent 122-7031 Agilent Column, DB-WAX, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.15. Temperature Limits (oC): 20 to 250/260.
Agilent 122-7032 Agilent DB*-Wax GC Column High polarity column for the analysis of solvents, aromatics, glycols, essential oils, flavors, fragrances and volatile fatty acids. Phase composition: cross linked/surface bonded polyethylene glycol. Range 20 to 250/260[degree]C. I.D. 0.25mm. Length 30m. Thickness 0.25um.
Agilent 122-7032E Agilent GC Column
Agilent 122-7033 Agilent DB*-Wax GC Column High polarity column for the analysis of solvents, aromatics, glycols, essential oils, flavors, fragrances and volatile fatty acids. Phase composition: cross linked/surface bonded polyethylene glycol. Range 20 to 240/250[degree]C. I.D. 0.25mm. Length 30m. Thickness 0.50um.
Agilent 122-7033E Agilent GC Column
Agilent 122-7061 Agilent DB-WAX HP-20M; SUPELCOWAX 10. Polyethylene glycol. High polarity. Improves resolution of low boiling point analyses. Column-to-column reproducibility. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 6000mm. Film: 0.15um. Temperature Range: 20 to 250[degree]C.
Agilent 122-7062 Agilent DB*-Wax GC Column High polarity column for the analysis of solvents, aromatics, glycols, essential oils, flavors, fragrances and volatile fatty acids. Phase composition: cross linked/surface bonded polyethylene glycol. Range 20 to 250/260[degree]C. I.D. 0.25mm. Length 60m. Thickness 0.25um.
Agilent 122-7062E Agilent GC Column, DB-1 60m, 0.25mm, 0.5um, 5in cage
Agilent 122-7063 Agilent Column, DB-WAX, 0.25mm I.D. x 60m Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.50. Temperature Limits (oC): 20 to 240/250.
Agilent 122-7063E Agilent GC Column, DB-5 60m, 0.25mm, 0.25um, 5in cage
Agilent 122-7332 Agilent Column, DB-WAXetr, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.25. Temperature Limits (oC): 30 to 260/280, Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW, 007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX.
Agilent 122-7332E Agilent GC Column, DB-5 30m, 0.25mm, 1.00um, 5in cage
Agilent 122-7333 Agilent Column, DB-WAXetr, 0.25mm I.D. x 30m Inner Diameter (mm I.D.): 0.25. Length (meter): 30. Film Thickness (um): 0.50. Temperature Limits (oC): 30 to 250/260, Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW, 007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX.
Agilent 122-7333E Agilent GC Column, DB-WAXETR 30m, 0.25mm, 0.25um, 5in cage
Agilent 122-7362 Agilent Column, DB-WAXetr, 0.25mm I.D. x 60m Inner Diameter (mm I.D.): 0.25. Length (meter): 60. Film Thickness (um): 0.25. Temperature Limits (oC): 30 to 260/280, Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW, 007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX.
Agilent 122-7362E Agilent GC Column, DB-5 60m, 0.25mm, 1.00um, 5in cage
Agilent 122-7363 Agilent DB-WAXetr HP-20M; SUPELCOWAX 10. Polyethylene glycol. Extended temperature range. High polarity. Excellent column-to-column repeatability. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 6000mm. Film: 0.5um. Temperature Range: 30 to 250[degree]C.
Agilent 122-7732 Agilent DB-1701P SPB-1701P. (14%-cyanopropyl-phenyl)-methylpolysiloxane. Low/midpolarity. Designed and processed for the analysis of organochlorine pesticides. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: -20 to 280[degree]C.
Agilent 123-0213 Agilent DB-210 SP-210. (50%-Trifluoropropyl)-methylpolysiloxane. High polarity, excellent for US EPA Methods 8140 and 609. Bonded and cross-linked. 0.32mm ID. Length: 1500mm. Film: 0.5um. Temperature Range: 45 to 240[degree]C.
Agilent 123-0232 Agilent Column, DB-210, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.25. Temperature Limits (oC): 45 to 240/260, Similar Phases: RSL-400, SP-2401, Rtx-200.
Agilent 123-0232E Agilent GC Column, CYCLODEX-B 30m, 0.25mm, 0.25um, 5in cage
Agilent 123-0233 Agilent DB*-210 GC Column High polarity column for organophosphorus pesticides, nitroaromatics, herbicides, disinfection by-products. Bonded 50% trifluoropropyl, 50% methylpolysiloxane. Range: 45 to 240[degree]C. ID: 0.32mm. Length: 30m. Film Thickness: 0.50um. For EPA methods 551, 552, 552.1, and 8141.
Agilent 123-0233E Agilent GC Column, CAM 30m, 0.25mm, 0.25um, 5in cage
Agilent 123-0712 Agilent Column, DB-1701, 0.32mm I.D. x 15m Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 0.25. Temperature Limits (oC): -20 to 280/300, Similar Phases to DB-1701: SPB-1701, CP-Sil 19CB, Rtx-1701, BP-10, CB-1701, OV-1701, PE-1701, 007-1701, ZB-1701, RH-1701.
Agilent 123-0713 Agilent DB-1701 SPB-1701, CP-Sil 19 CB. (14%-Cyanopropyl-phenyl)-methylpolysiloxane. Low to mid polarity. Solvent rinsable. Bonded and cross-linked. 0.32mm ID. Length: 1500mm. Film: 1um. Temperature Range: -20 to 280[degree]C.
Agilent 123-0731 Agilent DB*-1701 GC Column Low-to-mid polarity column with a dipole moment. Phase composition: bonded 14% cyanopropylphenyl, 86% dimethylpolysiloxane. Temperature range: -20 to 280/300[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness: 0.15um. For EPA methods 507, 508, 515, 515.2, 552, 552.1, and 8081.
Agilent 123-0732 Agilent DB*-1701 GC Column Low-to-mid polarity column with a dipole moment. Phase composition: bonded 14% cyanopropylphenyl, 86% dimethylpolysiloxane. Temperature range: -20 to 280/300[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness: 0.25um. For EPA methods 507, 508, 515, 515.2, 552, 552.1, and 8081.
Agilent 123-0732E Agilent GC Column
Agilent 123-0733 Agilent DB*-1701 GC Column Low-to-mid polarity column with a dipole moment. Phase composition: bonded 14% cyanopropylphenyl, 86% dimethylpolysiloxane. Temperature range: -20 to 280/300[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness: 1.00um. For EPA methods 507, 508, 515, 515.2, 552, 552.1, and 8081.
Agilent 123-0733E Agilent GC Column
Agilent 123-0753 Agilent DB-1701 SPB-1701, CP-Sil 19 CB. (14%-Cyanopropyl-phenyl)-methylpolysiloxane. Low to mid polarity. Solvent rinsable. Bonded and cross-linked. 0.32mm ID. Length: 5000mm. Film: 1um. Temperature Range: -20 to 280[degree]C.
Agilent 123-0753E Agilent GC Column, DB-WAX 60m, 0.25mm, 0.25um, 5in cage
Agilent 123-0762 Agilent DB-1701 SPB-1701; CP-Sil 19 CB. (14%-Cyanopropyl-phenyl)-methylpolysiloxane. Low to mid polarity. Solvent rinsable. Bonded and cross-linked. 0.32mm ID. Length: 6000mm. Film: 0.25um. Temperature Range: -20 to 280[degree]C.
Agilent 123-0762E Agilent GC Column, DB-1 60m, 0.53mm, 5.00um, 5in cage
Agilent 123-0763 Agilent Column, DB-1701, 0.32mm I.D. x 60m Inner Diameter (mm I.D.): 0.32. Length (meter): 60. Film Thickness (um): 1.00. Temperature Limits (oC): -20 to 280/300, Similar Phases to DB-1701: SPB-1701, CP-Sil 19CB, Rtx-1701, BP-10, CB-1701, OV-1701, PE-1701, 007-1701, ZB-1701, RH-1701.
Agilent 123-0763E Agilent DB-1701 Wound on 127mm cage.SPB-1701; CP-Sil 19 CB. (14%-Cyanopropyl-phenyl)-methylpolysiloxane. Wound on 127mm cage. Low to mid polarity. Solvent rinsable. Bonded and cross-linked. 0.32mm ID. Length: 6000mm. Film: 1um. Temperature Range: -20 to 280[degree]C.
Agilent 123-100E Agilent DB-1 10m, 0.32mm, 0.50 um
Agilent 123-1011 Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 1500mm. Film: 0.1um. Temperature Range: -60 to 325[degree]C.
Agilent 123-1012 Agilent DB*-1 GC Column A nonpolar column for compounds with similar polarities and larger differences in boiling points. Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods 504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.32mm. Length 15m. Thickness: 0.25um.
Agilent 123-1012E Agilent GC Column, DB-1 15m, 0.32mm, 0.25um, 5in cage
Agilent 123-1013 Agilent DB*-1 GC Column A nonpolar column for compounds with similar polarities and larger differences in boiling points. Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods 504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.32mm. Length 15m. Thickness 1.00um.
Agilent 123-1014 Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 1500mm. Film: 3um. Temperature Range: -60 to 280[degree]C.
Agilent 123-1015E Agilent GC Column, DB-1 15m, 0.32mm, 5.00um, 5in cage
Agilent 123-1022 Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 2500mm. Film: 0.25um. Temperature Range: -60 to 325[degree]C.
Agilent 123-1026 Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 2500mm. Film: 0.52um. Temperature Range: -60 to 325[degree]C.
Agilent 123-1027 Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 2500mm. Film: 0.12um. Temperature Range: -60 to 325[degree]C.
Agilent 123-102F Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 2500mm. Film: 1.05um. Temperature Range: -60 to 325[degree]C.
Agilent 123-1031 Agilent Column, DB-1, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.10. Temperature Limits (oC): -60 to 325/350.
Agilent 123-1032 Agilent DB*-1 GC Column A nonpolar column for compounds with similar polarities and larger differences in boiling points. Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods 504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.32mm. Length 30m. Thickness 0.25um.
Agilent 123-1032E Agilent GC Column, HP-1 30m, 0.32mm, 0.1um, 5in cage
Agilent 123-1033 Agilent DB*-1 GC Column A nonpolar column for compounds with similar polarities and larger differences in boiling points. Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods 504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.32mm. Length 30m. Thickness: 1.00um.
Agilent 123-1033E Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Wound on 127mm cage. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 1um. Temperature Range: -60 to 325[degree]C.
Agilent 123-1034 Agilent Column, DB-1, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 3.00. Temperature Limits (oC): -60 to 280/300.
Agilent 123-1034E Agilent GC Column, DB-1 30m, 0.32mm, 0.25um, 5in cage "
Agilent 123-1035 Agilent Column, DB-1, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 5.00. Temperature Limits (oC): -60 to 280/300.
Agilent 123-1035E Agilent GC Column, DB-1 30m, 0.32mm, 3.00um, 5in cage
Agilent 123-103B Agilent GC Column
Agilent 123-103E Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Wound on 127mm cage. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: -60 to 325[degree]C.
Agilent 123-1052 Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 5000mm. Film: 0.25um. Temperature Range: -60 to 325[degree]C.
Agilent 123-1055 Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 5000mm. Film: 5um. Temperature Range: -60 to 280[degree]C.
Agilent 123-1056 Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 5000mm. Film: 0.52um. Temperature Range: -60 to 325[degree]C.
Agilent 123-105C Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 5000mm. Film: 1.2um. Temperature Range: -60 to 325[degree]C.
Agilent 123-105F Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 5000mm. Film: 1.05um. Temperature Range: -60 to 325[degree]C.
Agilent 123-1061 Agilent DB*-1 GC Column A nonpolar column for compounds with similar polarities and larger differences in boiling points. Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods 504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.32mm. Length 60m. Thickness 0.10um.
Agilent 123-1062 Agilent DB*-1 GC Column A nonpolar column for compounds with similar polarities and larger differences in boiling points. Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods 504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.32mm. Length 60m. Thickness 0.25um.
Agilent 123-1062E Agilent GC Column, DB-1701 60m, 0.25mm, 1.00um, 5in cage
Agilent 123-1063 Agilent DB*-1 GC Column A nonpolar column for compounds with similar polarities and larger differences in boiling points. Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods 504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.32mm. Length 60m. Thickness 1.00um.
Agilent 123-1063E Agilent GC Column, DB-1 50m, 0.53mm, 5.0um, 5in cage
Agilent 123-1064 Agilent Column, DB-1, 0.32mm I.D. x 60m Inner Diameter (mm I.D.): 0.32. Length (meter): 60. Film Thickness (um): 3.00. Temperature Limits (oC): -60 to 280/300.
Agilent 123-1064E Agilent DB-1 60m, 0.32mm, 3.00um, 5 inch cage
Agilent 123-1065 Agilent DB*-1 GC Column A nonpolar column for compounds with similar polarities and larger differences in boiling points. Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods 504, 505, 515, 515.2, and 551. Range: -60 to 280/300[degree]C. ID 0.32mm. Length 60m. Thickness 5.00um.
Agilent 123-1065E Agilent GC Column
Agilent 123-106B Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 6000mm. Film: 1.5um. Temperature Range: -60 to 300[degree]C.
Agilent 123-106BE Agilent GC Column, HP-5 60m, 0.32mm, 1.0um, 5in cage
Agilent 123-106E Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Wound on 127mm cage. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 6000mm. Film: 0.5um. Temperature Range: -60 to 325[degree]C.
Agilent 123-106EE Agilent GC Column, HP-1, 60m, 0.32mm, 5.0um, 5in cage
Agilent 123-106G Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 6000mm. Film: 2um. Temperature Range: -60 to 280[degree]C.
Agilent 123-1111 Agilent Column, DB-1ht, 0.32mm I.D. x 15m Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 0.10. Temperature Limits (oC): -60 to 400, Similar Phases: PE-1ht.
Agilent 123-1131 Agilent Column, DB-1ht, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.10. Temperature Limits (oC): -60 to 400, Similar Phases: PE-1ht.
Agilent 123-1131E Agilent GC Column, CAM 30m, 0.32mm, 0.50um, 5in cage
Agilent 123-1232 Agilent DB-XLB MDN-12. Exceptionally low bleed. Low polarity. Designed to inhibit column bleed at high temperatures. Excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: 30 to 340[degree]C.
Agilent 123-1236 Agilent DB-XLB MDN-12. Exceptionally low bleed. Low polarity. Designed to inhibit column bleed at high temperatures. Excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: 30 to 340[degree]C.
Agilent 123-1262 Agilent Column, DB-XLB, 0.32mm I.D. x 60m Inner Diameter (mm I.D.): 0.32. Length (meter): 60. Film Thickness (um): 0.25. Temperature Limits (oC): 30 to 340/360, Similar Phases: PE-XLB, MDN-12.
Agilent 123-1332 Agilent Column, DB-1301, 0.32mm I.D. x 305m Inner Diameter (mm I.D.): 0.32. Length (meter): 305. Film Thickness (um): 0.25. Temperature Limits (oC): -20 to 280/300, Similar Phases to DB-1301: Rtx-1301, PE-1301, HP-1301.
Agilent 123-1333 Agilent DB-1301 Rtx-1301; PE-1301. (6%-cyanopropyl-phenyl) methylpolysiloxane. Low/midpolarity. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 1um. Temperature Range: -20 to 280[degree]C.
Agilent 123-1334 Agilent DB*-624 GC Column Intermediate polarity column for the analysis of volatile priority pollutants. Specified in EPA method 524.2. Phase composition: bonded 6% cyanopropyl-phenyl, 94% dimethylpolysiloxane. Temperature range: -20 to 260[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness: 1.80um.
Agilent 123-1334E Agilent DB-624 5 inch CAGE, 30M, 0.32 MM, 1.8U.
Agilent 123-1363 Agilent DB-1301 Rtx-1301; PE-1301. (6%-cyanopropyl-phenyl) methylpolysiloxane. Low/midpolarity. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 6000mm. Film: 1um. Temperature Range: -20 to 280[degree]C.
Agilent 123-1363E Agilent GC Column, DB-5 60m, 0.53mm, 5.00um, 5in cage
Agilent 123-1364 Agilent DB*-624 GC Column Intermediate polarity column for the analysis of volatile priority pollutants. Specified in EPA method 524.2. Phase composition: bonded 6% cyanopropyl-phenyl, 94% dimethylpolysiloxane. Temperature range: -20 to 260[degree]C. I.D.:0.32mm. Length: 60m. Film Thickness: 1.80um.
Agilent 123-1364E Agilent DB-624 AT-624. Wound on 127mm cage. Designed for the analysis of volatile priority pollutants. Excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 6000mm. Film: 1.8um. Temperature Range: -20 to 260[degree]C.
Agilent 123-1464 Agilent DB-502.2 Rtx-502.2; VOCOL. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 6000mm. Film: 1.8um. Temperature Range: 0 to 260[degree]C.
Agilent 123-1534 Agilent DB*-VRX GC Column Low polarity. For optimum resolution of volatiles and separation of the following coeluting compounds while maintaining good peak shape: m- and p-xylene; and 1,1,2,2-tetrachloroethane and o-xylene. Temperature range: -20 to 260[degree]C. ID: 0.32mm. Length: 30m. Thickness: 1.80um.
Agilent 123-1564 Agilent DB*-VRX GC Column Low polarity. For optimum resolution of volatiles and separation of the following coeluting compounds while maintaining good peak shape: m- and p-xylene; and 1,1,2,2-tetrachloroethane and o-xylene. Temperature range: -20 to 260[degree]C. ID: 0.32mm. Length: 60m. Thickness: 1.80um.
Agilent 123-1564E Agilent GC Column, DB-XLB 60m, 0.25mm, 0.25um, 5in cage
Agilent 123-1632 Agilent Column, DB-TPH, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.25. Temperature Limits (oC): -10 to 320, Similar Phases: PE-TPH.
Agilent 123-1711 Agilent Column, DB-17, 0.32mm I.D. x 15m Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 0.15. Temperature Limits (oC): 40 to 280/300, Similar Phases: HP-17, RSL-300, Rtx-50, PE-17, CC-17, 007-17 (MPS-50), SP-2250, HP-50+, SPB-50, ZB-50.
Agilent 123-1712 Agilent Column, DB-17, 0.32mm I.D. x 15m Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 0.25. Temperature Limits (oC): 40 to 280/300, Similar Phases: HP-17, RSL-300, Rtx-50, PE-17, CC-17, 007-17 (MPS-50), SP-2250, HP-50+, SPB-50, ZB-50.
Agilent 123-1712E Agilent GC Column, DB-17 15m, 0.32mm, 0.25um, 5in cage
Agilent 123-1713 Agilent Column, DB-17, 0.32mm I.D. x 15m Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 0.50. Temperature Limits (oC): 40 to 280/300, Similar Phases: HP-17, RSL-300, Rtx-50, PE-17, CC-17, 007-17 (MPS-50), SP-2250, HP-50+, SPB-50, ZB-50.
Agilent 123-1730 Agilent DB*-608 GC Column Intermediate polarity column for analyzing chlorinated pesticides and PCBs. For EPA method 608. Phase composition: cross-linked/surface bonded proprietary phase of dimethylphenyl-polysiloxane. Temperature range: 40 to 280[degree]C. ID: 0.32mm. Length: 30m. Film Thickness: 0.50um.
Agilent 123-1731 Agilent Column, DB-17, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.15. Temperature Limits (oC): 40 to 280/300, Similar Phases: HP-17, RSL-300, Rtx-50, PE-17, CC-17, 007-17 (MPS-50), SP-2250, HP-50+, SPB-50, ZB-50.
Agilent 123-1732 Agilent DB*-17 GC Column Intermediate polarity column. Use as a confirmation column for steroids, pesticides, herbicides, and drugs. Phase composition: bonded 50% diphenyl, 50% dimethylpolysiloxane. Temperature range: 40 to 280[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness: 0.25um.
Agilent 123-1732E Agilent GC Column
Agilent 123-1733 Agilent Column, DB-17, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.50. Temperature Limits (oC): 40 to 280/300, Similar Phases: HP-17, RSL-300, Rtx-50, PE-17, CC-17, 007-17 (MPS-50), SP-2250, HP-50+, SPB-50, ZB-50.
Agilent 123-1733E Agilent GC Column, DB-1 30m, 0.32mm,5.0um, 5in cage
Agilent 123-1762 Agilent DB-17 HP-50+; Rtx-50. (50%-phenyl)-methylpolysiloxane. Midpolarity. Excellent for confirmational analyses. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 6000mm. Film: 0.25um. Temperature Range: 40 to 280[degree]C.
Agilent 123-1811 Agilent Column, DB-17ht, 0.32mm I.D. x 15m Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 0.15. Temperature Limits (oC): 40 to 340/365, Similar Phases: Rtx-65TG, PE-17ht.
Agilent 123-1831 Agilent Column, DB-17ht, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.15. Temperature Limits (oC): 40 to 340/365, Similar Phases: Rtx-65TG, PE-17ht.
Agilent 123-1831E Agilent DB-17HT 30m, 0.32mm, 0.15um, 5 inch cage
Agilent 123-1932 Agilent Column, DB-35, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.25. Temperature Limits (oC): 40 to 300/320, Similar Phases: Rtx-35, SPB-35, AT-35, Sup-Herb, PE-35.
Agilent 123-1933 Agilent DB-35 Rtx-35; SPB-35. (35%-phenyl)-methylpolysiloxane. Midpolarity. Low bleed. Inert to active solutes. Ideal for confirmational analyses. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: 40 to 300[degree]C.
Agilent 123-1933E Agilent GC Column, DB-17 30m, 0.32mm, 0.50um, 5in cage
Agilent 123-2032 Agilent Column, DB-200, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.25. Temperature Limits (oC): 30 to 300/320, Similar Phases: Rtx-200.
Agilent 123-2033 Agilent Column, DB-200, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.50. Temperature Limits (oC): 30 to 300/320, Similar Phases: Rtx-200.
Agilent 123-2232 Agilent Column, DB-225, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.25. Temperature Limits (oC): 40 to 220/240, Similar Phases: HP-225, SP-2330, CP-Sil 43CB, RSL-500, Rtx-225, BP-225, CB-225, OV-225, PE-225, 007-225.
Agilent 123-2232E Agilent GC Column, DB-210 30m, 0.32mm, 0.25um, 5in cage
Agilent 123-2332 Agilent Column, DB-23, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.25. Temperature Limits (oC): 40 to 250/260, Similar Phases: SP-2330, Rtx-2330, 007-23, AT-Silar, PE-23.
Agilent 123-2332E Agilent GC Column, HP50+, 30m, 0.32mm, 0.5um, 5in cage
Agilent 123-2362 Agilent Column, DB-23, 0.32mm I.D. x 60m Inner Diameter (mm I.D.): 0.32. Length (meter): 60. Film Thickness (um): 0.25. Temperature Limits (oC): 40 to 250/260, Similar Phases: SP-2330, Rtx-2330, 007-23, AT-Silar, PE-23.
Agilent 123-2932 Agilent DB-225ms HP-225. Equivalent to (50%-cyanopropylphenyl)-dimethylpolysiloxane. Mid/high polarity. For separations of cis- and trans-fatty acid methyl esters. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: 40 to 240[degree]C.
Agilent 123-3212 Agilent DB-FFAP Stabilwax-DA, HP-FFAP. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 1500mm. Film: 0.25um. Temperature Range: 40 to 250[degree]C.
Agilent 123-3223 Agilent DB-FFAP Stabilwax-DA, HP-FFAP. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 2500mm. Film: 0.5um. Temperature Range: 40 to 250[degree]C.
Agilent 123-3232 Agilent DB*-FFAP GC Column High polarity column for analysis of volatile fatty acids and phenols. Phase composition: cross-linked/surface bonded nitroterephthalic acid modified polyethylene glycol stationary phase. Temperature range: 40 to 250[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness: 0.25um.
Agilent 123-3232E Agilent DB-FFAP Stabilwax-DA. Wound on 127mm cage. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: 40 to 250[degree]C.
Agilent 123-3233 Agilent DB-FFAP Stabilwax-DA, HP-FFAP. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: 40 to 250[degree]C.
Agilent 123-3233E Agilent GC Column, DB-ALC2 30m, 0.32mm, 1.20um, 5in cage
Agilent 123-3234 Agilent DB-FFAP Stabilwax-DA, HP-FFAP. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 1um. Temperature Range: 40 to 250[degree]C.
Agilent 123-3253 Agilent DB-FFAP Stabilwax-DA, HP-FFAP. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 5000mm. Film: 0.5um. Temperature Range: 40 to 250[degree]C.
Agilent 123-3262 Agilent DB-FFAP Stabilwax-DA, HP-FFAP. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 6000mm. Film: 0.25um. Temperature Range: 40 to 250[degree]C.
Agilent 123-3263 Agilent DB-FFAP Stabilwax-DA, HP-FFAP. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 6000mm. Film: 0.5um. Temperature Range: 40 to 250[degree]C.
Agilent 123-3264 Agilent DB-FFAP Stabilwax-DA, HP-FFAP. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 6000mm. Film: 1um. Temperature Range: 40 to 250[degree]C.
Agilent 123-3812 Agilent DB-35ms Rtx-35; SPB-35. Equivalent to (35%-phenyl)-methylpolysiloxane. Midpolarity. Low bleed, excellent inertness for active compounds. Ideal for confirmational analyses. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 1500mm. Film: 0.25um. Temperature Range: 50 to 340[degree]C.
Agilent 123-3832 Agilent Column, DB-35ms, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.25. Temperature Limits (oC): 50 to 340/360, Similar Phases: Rtx-35, SPB-35, AT-35, Sup-Herb, PE-35ms, MDN-35.
Agilent 123-3832E Agilent GC Column, HP-PLOT U, 30m, 0.32mm, 10um, 5in cage
Agilent 123-4712 Agilent Column, DB-17ms, 0.32mm I.D. x 15m Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 0.25. Temperature Limits (oC): 40 to 320/340, Similar Phases: HP-50+, Rtx-50, PE-17, 007-17, SP-2250, SPB-50, BPX-50, SPB-17.
Agilent 123-4732 Agilent Column, DB-17ms, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.25. Temperature Limits (oC): 40 to 320/340, Similar Phases: HP-50+, Rtx-50, PE-17, 007-17, SP-2250, SPB-50, BPX-50, SPB-17.
Agilent 123-500E Agilent DB-5 10m, 0.32mm, 0.50 um
Agilent 123-5011 Agilent Column, DB-5, 0.32mm I.D. x 15m Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 0.10.
Agilent 123-5012 Agilent DB*-5 GC Column Nonpolar. Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95% methylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.32mm. Length 15m. Thickness 0.25um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680, 1625, 1653, 8081, 8141, 8270, 8280.
Agilent 123-5012E Agilent DB-5 HP-5; Ultra-2; SP-B-5. Wound on a 127mm cage. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 1500mm. Film: 0.25um. Temperature Range: -60 to 325[degree]C.
Agilent 123-5013 Agilent Column, DB-5, 0.32mm I.D. x 15m Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um)1.00.
Agilent 123-5013E Agilent GC Column, DB-5 15m, 0.32mm, 1.00um, 5in cage
Agilent 123-5022 Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 2500mm. Film: 0.25um. Temperature Range: -60 to 325[degree]C.
Agilent 123-5026 Agilent DB*-5 GC Column Nonpolar. Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95% methylpolysiloxane. Range -60 to 325/350[Degree]C. I.D. 0.32mm. Length 25m. Thickness 0.52um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680, 1625, 1653, 8081, 8141, 8270, 8280.
Agilent 123-502D Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 2500mm. Film: 0.17um. Temperature Range: -60 to 325[degree]C.
Agilent 123-502F Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 2500mm. Film: 1.05um. Temperature Range: -60 to 325[degree]C.
Agilent 123-5031 Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 0.1um. Temperature Range: -60 to 325[degree]C.
Agilent 123-5032 Agilent DB*-5 GC Column Nonpolar. Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95% methylpolysiloxane. Range -60 to 325/350[Degree]C. I.D. 0.32mm. Length 30m. Thickness 0.25um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680, 1625, 1653, 8081, 8141, 8270, 8280.
Agilent 123-5032E Agilent GC Column
Agilent 123-5033 Agilent DB*-5 GC Column Nonpolar. Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95% methylpolysiloxane. Range -60 to 325/350[Degree]C. I.D. 0.32mm. Length 30m. Thickness 1um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680, 1625, 1653, 8081, 8141, 8270, 8280.
Agilent 123-5033E Agilent GC Column, DB-35 30m, 0.32mm, 0.50um, 5in cage
Agilent 123-503B Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 1.5um. Temperature Range: -60 to 325[degree]C.
Agilent 123-503E Agilent DB-5 HP-5; Ultra-2; SP-B-5. Wound on 127mm cage. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: -60 to 325[degree]C.
Agilent 123-5052 Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 5000mm. Film: 0.25um. Temperature Range: -60 to 325[degree]C.
Agilent 123-5053 Agilent Column, DB-5, 0.32mm I.D. x 50m Inner Diameter (mm I.D.): 0.32. Length (meter): 50. Film Thickness (um): 1.00.
Agilent 123-5056 Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 5000mm. Film: 0.52um. Temperature Range: -60 to 325[degree]C.
Agilent 123-5062 Agilent DB*-5 GC Column Nonpolar. Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95% methylpolysiloxane. Range -60 to 325/350[Degree]C. I.D. 0.32mm. Length 50m. Thickness 0.25um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680, 1625, 1653, 8081, 8141, 8270, 8280.
Agilent 123-5063 Agilent DB*-5 GC Column Nonpolar. Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95% methylpolysiloxane. Range -60 to 325/350[Degree]C. I.D. 0.32mm. Length 60m. Thickness 1um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680, 1625, 1653, 8081, 8141, 8270, 8280.
Agilent 123-5511 Agilent Column, DB-5ms, 0.32mm I.D. x 15m Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 0.10. Temperature Limits (oC): -60 to 325/350, Similar Phases: Rtx-5MS, HP-5MS, PTE-5, CP Sil 8 CBms, BPX-5, RH-5ms, HP-5 Trace.
Agilent 123-5512 Agilent Column, DB-5ms, 0.32mm I.D. x 15m Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 0.25. Temperature Limits (oC): -60 to 325/350, Similar Phases: Rtx-5MS, HP-5MS, PTE-5, CP Sil 8 CBms, BPX-5, RH-5ms, HP-5 Trace.
Agilent 123-5513 Agilent Column, DB-5ms, 0.32mm I.D. x 15m Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 1.00. Temperature Limits (oC): -60 to 325/350, Similar Phases: Rtx-5MS, HP-5MS, PTE-5, CP Sil 8 CBms, BPX-5, RH-5ms, HP-5 Trace.
Agilent 123-5513E Agilent DB-5MS 15m, 0.32mm, 1.00um, 5 inch cage
Agilent 123-5526 Agilent Column, DB-5ms, 0.32mm I.D. x 25m Inner Diameter (mm I.D.): 0.32. Length (meter): 25. Film Thickness (um): 0.52. Temperature Limits (oC): -60 to 325/350, Similar Phases: Rtx-5MS, HP-5MS, PTE-5, CP Sil 8 CBms, BPX-5, RH-5ms, HP-5 Trace.
Agilent 123-5531 Agilent DB*-5ms GC Column Nonpolar. MS certified. Improved signal-to-noise ratio for better sensitivity and mass spectral integrity with basic and acidic analytes. Composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Temperature range -60 to 325/350[degree]C. I.D. 0.32mm. Length 30m. Thickness 0.10um.
Agilent 123-5532 Agilent DB*-5ms GC Column Nonpolar. MS certified. Improved signal-to-noise ratio for better sensitivity and mass spectral integrity with basic and acidic analytes. Composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Temperature range: -60 to 325/350[degree]C. I.D. 0.32mm. Length 30m. Thickness 0.25um.
Agilent 123-5532E Agilent DB-5ms Rtx-5ms. Wound on 127mm cage. Phenyl Arylene polymer equivalent to (5%-phenyl)-methylpolysiloxane. Non-polar. Low bleed, excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: -60 to 325[degree]C.
Agilent 123-5533 Agilent DB*-5ms GC Column Nonpolar. MS certified. Improved signal-to-noise ratio for better sensitivity and mass spectral integrity with basic and acidic analytes. Composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Temperature range -60 to 325/350[degree]C. I.D. 0.32mm. Length 30m. Thickness 1.00um.
Agilent 123-5533G Agilent DuraGuard GC Column Phase: DB-5ms. I.D.: 0.32mm. Length: 30m. Film thickness: 1.00um. Features a built-in length of deactivated fused silica tubing that eliminates problems with peak shape, installation hassles, and leaks associated with unions.
Agilent 123-5536 Agilent DB*-5ms GC Column Nonpolar. MS certified. Improved signal-to-noise ratio for better sensitivity and mass spectral integrity with basic and acidic analytes. Composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Temperature range: -60 to 325/350[degree]C. I.D. 0.32mm. Length 30m. Thickness 0.50um.
Agilent 123-5561 Agilent DB-5ms Rtx-5ms. Phenyl Arylene polymer equivalent to (5%-phenyl)-methylpolysiloxane. Non-polar. Low bleed, excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 6000mm. Film: 0.1um. Temperature Range: -60 to 325[degree]C.
Agilent 123-5562 Agilent DB*-5ms GC Column Nonpolar. MS certified. Improved signal-to-noise ratio for better sensitivity and mass spectral integrity with basic and acidic analytes. Composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Temperature range -60 to 325/350[degree]C. I.D. 0.32mm. Length 60m. Thickness 0.25um.
Agilent 123-5563 Agilent Column, DB-5ms, 0.32mm I.D. x 60m Inner Diameter (mm I.D.): 0.32. Length (meter): 60. Film Thickness (um): 1.00. Temperature Limits (oC): -60 to 325/350, Similar Phases: Rtx-5MS, HP-5MS, PTE-5, CP Sil 8 CBms, BPX-5, RH-5ms, HP-5 Trace.
Agilent 123-5566 Agilent GC Column
Agilent 123-5631 Agilent DB*-5.625 GC Column Nonpolar, inert. For analyzing BNAs. Meet EPA semi-volatiles performance criteria for CLP protocols and EPA methods 625, 1625, and 8270. Bonded 5% phenyl, 95% methylpolysiloxane. Temperature range: -60 to 325/350[degree]C. I.D. 0.32mm. Length 30m. Thickness 0.25um.
Agilent 123-5632 Agilent DB*-5.625 GC Column Nonpolar, inert. For analyzing BNAs. Meet EPA semi-volatiles performance criteria for CLP protocols and EPA methods 625, 1625, and 8270. Bonded 5% phenyl, 95% methylpolysiloxane. Temperature range: -60 to 325/350[degree]C. I.D. 0.32mm. Length 30m. Thickness 0.50um.
Agilent 123-5701 Agilent Db-5Ht, 10M, 0.32Mm, 0.10Um
Agilent 123-5711 Agilent Column, DB-5ht, 0.32mm I.D. x 15m Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 0.10. Temperature Limits (oC): -60 to 400, Similar Phases: PE-5ht.
Agilent 123-5711E Agilent GC Column, DB-FFAP 15m, 0.53mm, 1.00um, 5in cage
Agilent 123-5731 Agilent Column, DB-5ht, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.10. Temperature Limits (oC): -60 to 400, Similar Phases: PE-5ht.
Agilent 123-5731E Agilent Capillary Columns The Agilent J&W DB-5ht is a non-polar column specially processed for extended temperature limit of 400 deg C
Agilent 123-6133 Agilent Column, DX-1, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 1.00. Temperature Limits (oC): 50 to 250/270.
Agilent 123-6412 Agilent Column, DX-4, 0.32mm I.D. x 15m Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 0.25. Temperature Limits (oC): 50 to 250/270.
Agilent 123-6432 Agilent DX-4 15% dimethylpolysiloxane - 85% polyethylene glycol. 0.32mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: 50 to 250[degree]C.
Agilent 123-6462 Agilent DX-4 15% dimethylpolysiloxane - 85% polyethylene glycol. 0.32mm ID. Length: 6000mm. Film: 0.25um. Temperature Range: 50 to 250[degree]C.
Agilent 123-7012 Agilent DB-WAX HP-20M; SUPELCOWAX 10. Polyethylene glycol. High polarity. Improves resolution of low boiling point analyses. Column-to-column reproducibility. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 1500mm. Film: 0.25um. Temperature Range: 20 to 250[degree]C.
Agilent 123-7013 Agilent DB*-Wax GC Column High polarity column for the analysis of solvents, aromatics, glycols, essential oils, flavors, fragrances and volatile fatty acids. Phase composition: cross linked/surface bonded polyethylene glycol. Range 20 to 240/250[degree]C. I.D. 0.32mm. Length 15m. Thickness 0.50um.
Agilent 123-7031 Agilent DB-WAX HP-20M; SUPELCOWAX 10. Polyethylene glycol. High polarity. Improves resolution of low boiling point analyses. Column-to-column reproducibility. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 0.15um. Temperature Range: 20 to 250[degree]C.
Agilent 123-7032 Agilent DB*-Wax GC Column High polarity column for the analysis of solvents, aromatics, glycols, essential oils, flavors, fragrances and volatile fatty acids. Phase composition: cross linked/surface bonded polyethylene glycol. Range 20 to 250/260[degree]C. I.D. 0.32mm. Length 30m. Thickness 0.25um.
Agilent 123-7032E Agilent GC Column
Agilent 123-7033 Agilent DB*-Wax GC Column High polarity column for the analysis of solvents, aromatics, glycols, essential oils, flavors, fragrances and volatile fatty acids. Phase composition: cross linked/surface bonded polyethylene glycol. Range 20 to 240/250[degree]C. I.D. 0.32mm. Length 30m. Thickness 0.50um.
Agilent 123-7033E Agilent DB-WAX HP-20M; SUPELCOWAX 10. Wound on 127mm cage. Polyethylene glycol. High polarity. Improves resolution of low boiling point analyses. Column-to-column reproducibility. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: 20 to 250[degree]C.
Agilent 123-7062 Agilent Column, DB-WAX, 0.32mm I.D. x 60m Inner Diameter (mm I.D.): 0.32. Length (meter): 60. Film Thickness (um): 0.25. Temperature Limits (oC): 20 to 250/260.
Agilent 123-7063 Agilent Column, DB-WAX, 0.32mm I.D. x 60m Inner Diameter (mm I.D.): 0.32. Length (meter): 60. Film Thickness (um): 0.50. Temperature Limits (oC): 20 to 240/250.
Agilent 123-7063E Agilent GC Column
Agilent 123-7312 Agilent Column, DB-WAXetr, 0.32mm I.D. x 15m Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 0.25. Temperature Limits (oC): 30 to 260/280, Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW, 007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX.
Agilent 123-7314 Agilent Column, DB-WAXetr, 0.32mm I.D. x 15m Inner Diameter (mm I.D.): 0.32. Length (meter): 15. Film Thickness (um): 1.00. Temperature Limits (oC): 30 to 250/260, Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW, 007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX.
Agilent 123-7332 Agilent Column, DB-WAXetr, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.25. Temperature Limits (oC): 30 to 260/280, Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW, 007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX.
Agilent 123-7332E Agilent GC Column, DB-5 30m, 0.32mm, 1.00um, 5in cage
Agilent 123-7333 Agilent Column, DB-WAXetr, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 0.50. Temperature Limits (oC): 30 to 250/260, Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW, 007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX.
Agilent 123-7334 Agilent Column, DB-WAXetr, 0.32mm I.D. x 30m Inner Diameter (mm I.D.): 0.32. Length (meter): 30. Film Thickness (um): 1.00. Temperature Limits (oC): 30 to 250/260, Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW, 007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX.
Agilent 123-7354 Agilent Column, DB-WAXetr, 0.32mm I.D. x 50m Inner Diameter (mm I.D.): 0.32. Length (meter): 50. Film Thickness (um): 1.00. Temperature Limits (oC): 30 to 250/260, Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW, 007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX.
Agilent 123-7354E Agilent GC Column, HP-88 60m, 0.25mm, 0.2um, 5in cage
Agilent 123-7362 Agilent Column, DB-WAXetr, 0.32mm I.D. x 60m Inner Diameter (mm I.D.): 0.32. Length (meter): 60. Film Thickness (um): 0.25. Temperature Limits (oC): 30 to 260/280, Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW, 007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX.
Agilent 123-7362E Agilent GC Column, DB-1 60m, 0.32mm, 0.25um, 5in cage
Agilent 123-7363 Agilent Column, DB-WAXetr, 0.32mm I.D. x 60m Inner Diameter (mm I.D.): 0.32. Length (meter): 60. Film Thickness (um): 0.50. Temperature Limits (oC): 30 to 250/260, Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW, 007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX.
Agilent 123-7363E Agilent GC Column, DB-1 60m, 0.32mm, 1.00um, 5in cage
Agilent 123-7364 Agilent Column, DB-WAXetr, 0.32mm I.D. x 60m Inner Diameter (mm I.D.): 0.32. Length (meter): 60. Film Thickness (um): 1.00. Temperature Limits (oC): 30 to 250/260, Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW, 007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX.
Agilent 123-7722 Agilent DB-1701P SPB-1701P. (14%-cyanopropyl-phenyl)-methylpolysiloxane. Low/midpolarity. Designed and processed for the analysis of organochlorine pesticides. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 2500mm. Film: 0.25um. Temperature Range: -20 to 280[degree]C.
Agilent 123-7732 Agilent DB-1701P SPB-1701P. (14%-cyanopropyl-phenyl)-methylpolysiloxane. Low/midpolarity. Designed and processed for the analysis of organochlorine pesticides. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: -20 to 280[degree]C.
Agilent 123-9134 Agilent DB-ALC1 Rtx-BAC1. Provides reliable blood alcohol analysis. Bonded and cross-linked. 0.32mm ID. Length: 3000mm. Film: 1.8um. Temperature Range: 20 to 260[degree]C.
Agilent 123-9234 Agilent DB-ALC2 Rtx-BAC2. Provides reliable blood alcohol analysis. Bonded and cross-linked. 0.32mm ID. Length: 3000mm. Film: 1.2um. Temperature Range: 20 to 260[degree]C.
Agilent 123-9234E Agilent GC Column, DB-WAXETR 30m, 0.32mm, 0.25um, 5in cage
Agilent 124-0034 Agilent Column, DB-MTBE, 0.45mm I.D. x 30m Inner Diameter (mm I.D.): 0.45. Length (meter): 30. Film Thickness (um): 2.55. Temperature Limits (oC): 10 to 250, Similar Phases: None.
Agilent 124-1032 Agilent DB-1 HP-1, Ultra-1, SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.45mm ID. Length: 3000mm. Film: 1.27um. Temperature Range: -60 to 300[degree]C.
Agilent 124-1034 Agilent DB-1 HP-1, Ultra-1, SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.45mm ID. Length: 3000mm. Film: 2.55um. Temperature Range: -60 to 260[degree]C.
Agilent 124-1334 Agilent Column, DB-624, 0.45 x 30m Diameter (mm I.D.): 0.45. Inner Length (meter): 30. Film Thickness (um): 2.55. Temperature Limits (oC): -20 to 260, Similar Phases: VOCOL, NON-PAKD, AT-624, Rtx-Volatiles, Rtx-502.2, PE-624, PE-502, 007-624, 007-502, HP-624, CP-624, ZB-624.
Agilent 124-1374 Agilent DB-624 AT-624. Designed for the analysis of volatile priority pollutants. Excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.45mm ID. Length: 7500mm. Film: 2.55um. Temperature Range: -20 to 260[degree]C.
Agilent 124-1534 Agilent DB*-VRX GC Column Low polarity. For optimum resolution of volatiles and separation of the following coeluting compounds while maintaining good peak shape: m- and p-xylene; and 1,1,2,2-tetrachloroethane and o-xylene. Temperature range: -20 to 260[degree]C. ID: 0.45mm. Length: 30m. Thickness: 2.55um.
Agilent 124-1574 Agilent DB*-VRX GC Column Low polarity. For optimum resolution of volatiles and separation of the following coeluting compounds while maintaining good peak shape: m- and p-xylene; and 1,1,2,2-tetrachloroethane and o-xylene. Temperature range: -20 to 260[degree]C. ID: 0.45mm. Length: 75m. Thickness: 2.55um.
Agilent 124-1730 Agilent DB-608 SPB-608, NON-PAKD Pesticide. Designed for analysis of chlorinated pesticides and PCBs. Excellent inertness and recoveries without pesticide breakdown. Bonded and cross-linked. Solvent rinsable. 0.45mm ID. Length: 3000mm. Film: 0.7um. Temperature Range: 40 to 260[degree]C.
Agilent 124-3232 Agilent DB-FFAP Stabilwax-DA, HP-FFAP. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.45mm ID. Length: 3000mm. Film: 0.85um. Temperature Range: 40 to 250[degree]C.
Agilent 124-5012 Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.45mm ID. Length: 1500mm. Film: 1.27um. Temperature Range: -60 to 300[degree]C.
Agilent 124-5032 Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.45mm ID. Length: 3000mm. Film: 1.27um. Temperature Range: -60 to 300[degree]C.
Agilent 124-5037 Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.45mm ID. Length: 3000mm. Film: 0.42um. Temperature Range: -60 to 300[degree]C.
Agilent 124-7032 Agilent DB-WAX HP-20M. Polyethylene glycol. High polarity. Improves resolution of low boiling point analyses. Column-to-column reproducibility. Bonded and cross-linked. Solvent rinsable. 0.45mm ID. Length: 3000mm. Film: 0.85um. Temperature Range: 20 to 230[degree]C.
Agilent 125-0034 Agilent Column, DB-MTBE, 0.53mm I.D. x 30m Inner Diameter (mm I.D.): 0.53. Length (meter): 30. Film Thickness (um): 3.00. Temperature Limits (oC): 10 to 250, Similar Phases: None.
Agilent 125-0034E Agilent DB-MTBE Wound on 127mm cage. Low polarity stationary phase. Resolves MTBE from 2-methylpentane and 3-methylpentane. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 3um. Temperature Range: 35 to 260[degree]C.
Agilent 125-0212 Agilent DB*-210 GC Column High polarity column for organophosphorus pesticides, nitroaromatics, herbicides, and disinfection by-products. Bonded 50% trifluoropropyl, 50% methylpolysiloxane. Range: 45 to 240[degree]C. ID: 0.53m. Length: 15m. Film Thickness: 1.00um. For EPA methods 551, 552, 552.1, and 8141.
Agilent 125-0232 Agilent DB*-210 GC Column High polarity column for organophosphorus pesticides, nitroaromatics, herbicides, and disinfection by-products. Bonded 50% trifluoropropyl, 50% methylpolysiloxane. Range: 45 to 240[degree]C. ID: 0.53mm. Length: 30m. Film Thickness: 1.00um. For EPA methods 551, 552, 552.1 and 8141.
Agilent 125-0232E Agilent GC Column, HP-5MS, 30m, 0.32mm, 0.25um, 5in cage
Agilent 125-0712 Agilent Column, DB-1701, 0.53mm I.D. x 15m Inner Diameter (mm I.D.): 0.53. Length (meter): 15. Film Thickness (um): 1.00. Temperature Limits (oC): -20 to 260/280, Similar Phases to DB-1701: SPB-1701, CP-Sil 19CB, Rtx-1701, BP-10, CB-1701, OV-1701, PE-1701, 007-1701, ZB-1701, RH-1701.
Agilent 125-0712E Agilent GC Column, HP-1MS 15m, 0.25mm, 0.25um, 5in cage
Agilent 125-0731 Agilent DB-1701 SPB-1701; CP-Sil 19 CB. (14%-Cyanopropyl-phenyl)-methylpolysiloxane. Low to mid polarity. Solvent rinsable. Bonded and cross-linked. 0.53mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: -20 to 260[degree]C.
Agilent 125-0732 Agilent DB*-1701 GC Column Low-to-mid polarity column with a dipole moment. Phase composition: bonded 14% cyanopropylphenyl, 86% dimethylpolysiloxane. Temperature range: -20 to 280/300[degree]C. I.D.: 0.53mm. Length: 30m. Film Thickness: 1.00um. For EPA methods 507, 508, 515, 515.2, 552, 552.1, and 8081.
Agilent 125-0732E Agilent DB-1701 SPB-1701; CP-Sil 19 CB. Wound on 127mm cage. (14%-Cyanopropyl-phenyl)-methylpolysiloxane. Low to mid polarity. Sovent rinsable. Bonded and cross-linked. 0.53mm ID. Length: 3000mm. Film: 1um. Temperature Range: -20 to 260[degree]C.
Agilent 125-0732G Agilent DuraGuard GC Column Phase: DB-1701. I.D.: 0.53mm. Length: 30m. Film thickness: 1.00um. Features a built-in length of deactivated fused silica tubing that eliminates problems with peak shape, installation hassles, and leaks associated with unions.
Agilent 125-0733 Agilent DB-1701 SPB-1701; CP-Sil 19 CB. (14%-Cyanopropyl-phenyl)-methylpolysiloxane. Low to mid polarity. Solvent rinsable. Bonded and cross-linked. 0.53mm ID. Length: 3000mm. Film: 1.5um. Temperature Range: -20 to 260[degree]C.
Agilent 125-0737 Agilent DB*-1701 GC Column Low-to-mid polarity column with a dipole moment. Phase composition: bonded 14% cyanopropylphenyl, 86% dimethylpolysiloxane. Temperature range: -20 to 280/300[degree]C. I.D.: 0.53mm. Length: 30m. Film Thickness: 0.50um. For EPA methods 507, 508, 515, 515.2, 552, 552.1, and 8081.
Agilent 125-0762 Agilent GC Column
Agilent 125-0762E Agilent GC Column, DB-WAX 60m, 0.53mm, 1.00um, 5in cage
Agilent 125-1002 Agilent DB-1 7.5M x 0.53 mm, 1.5 um film.
Agilent 125-1002E Agilent DB-1 7.5M x 0.53 mm, 1.5 um film, 5 inch.
Agilent 125-1005 Agilent DB-1 HP-1, Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 500mm. Film: 5um. Temperature Range: -60 to 260[degree]C.
Agilent 125-100B Agilent DB-1 HP-1, Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 500mm. Film: 2.65um. Temperature Range: -60 to 260[degree]C.
Agilent 125-1011 Agilent DB*-1 GC Column A nonpolar column for compounds with similar polarities and larger differences in boiling points. Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods 504, 505, 515, 515.2, and 551. Range: -60 to 340/360[degree]C. ID 0.53mm. Length 15m. Thickness 0.15um.
Agilent 125-1011E Agilent GC Column
Agilent 125-1012 Agilent DB*-1 GC Column A nonpolar column for compounds with similar polarities and larger differences in boiling points. Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods 504, 505, 515, 515.2, and 551. Range: -60 to 300/320[degree]C. ID 0.53mm. Length 15m. Thickness 1.50um.
Agilent 125-1012E Agilent GC Column
Agilent 125-1014 Agilent Column, DB-1, 0.53mm I.D. x 15m Inner Diameter (mm I.D.): 0.53. Length (meter): 15. Film Thickness (um): 3.00. Temperature Limits (oC): -60 to 260/280.
Agilent 125-1015 Agilent DB*-1 GC Column A nonpolar column for compounds with similar polarities and larger differences in boiling points. Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods 504, 505, 515, 515.2, and 551. Range: -60 to 260/280[degree]C. ID 0.53mm. Length 15m. Thickness 5.00um.
Agilent 125-1015E Agilent GC Column, HP-1, 15m, 0.53mm, 1.5um, 5in cage
Agilent 125-1017 Agilent DB-1 HP-1; Ultra-1, SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 1500mm. Film: 0.5um. Temperature Range: -60 to 300[degree]C.
Agilent 125-101J Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 1500mm. Film: 1um. Temperature Range: -60 to 300[degree]C.
Agilent 125-101K Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 1500mm. Film: 0.25um. Temperature Range: -60 to 320[degree]C.
Agilent 125-1025 Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 2500mm. Film: 5um. Temperature Range: -60 to 260[degree]C.
Agilent 125-102J Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 2500mm. Film: 1um. Temperature Range: -60 to 300[degree]C.
Agilent 125-1032 Agilent DB*-1 GC Column A nonpolar column for compounds with similar polarities and larger differences in boiling points. Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods 504, 505, 515, 515.2, and 551. Range -60 to 300/320[degree]C. ID 0.53mm. Length 30m. Film Thickness 1.50um.
Agilent 125-1032E Agilent GC Column, HP-50+ 30m, 0.53mm, 0.5um, 5in cage
Agilent 125-1034 Agilent DB*-1 GC Column A nonpolar column for compounds with similar polarities and larger differences in boiling points. Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods 504, 505, 515, 515.2, and 551. Range: -60 to 260/280[degree]C. ID 0.53mm. Length 30m. Thickness 3.00um.
Agilent 125-1034E Agilent GC Column
Agilent 125-1035 Agilent DB*-1 GC Column A nonpolar column for compounds with similar polarities and larger differences in boiling points. Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods 504, 505, 515, 515.2, and 551. Range: -60 to 260/280[degree]C. ID 0.53mm. Length 30m. Thickness 5.00um.
Agilent 125-1035E Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Wound on 127mm cage. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 5um. Temperature Range: -60 to 260[degree]C.
Agilent 125-1037 Agilent DB*-1 GC Column A nonpolar column for compounds with similar polarities and larger differences in boiling points. Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods 504, 505, 515, 515.2, and 551. Range -60 to 300/320[degree]C. ID 0.53mm. Length 30m. Thickness 0.50um.
Agilent 125-1039 Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 0.1um. Temperature Range: -60 to 340[degree]C.
Agilent 125-103B Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 2.65um. Temperature Range: -60 to 260[degree]C.
Agilent 125-103J Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 1um. Temperature Range: -60 to 300[degree]C.
Agilent 125-103JE Agilent GC Column, HP-1 30m, 0.53mm, 0.88um, 5in cage
Agilent 125-103K Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: -60 to 320[degree]C.
Agilent 125-103KE Agilent DB-1 30m, 0.53mm, 0.25um, 5 inch cage
Agilent 125-1055 Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 5000mm. Film: 5um. Temperature Range: -60 to 260[degree]C.
Agilent 125-1055E Agilent GC Column, DB-23 60m, 0.25mm, 0.15um, 5in cage
Agilent 125-1062 Agilent Column, DB-1, 0.53mm I.D. x 60m Inner Diameter (mm I.D.): 0.53. Length (meter): 60. Film Thickness (um): 1.50. Temperature Limits (oC): -60 to 300/320.
Agilent 125-1062E Agilent GC Column, DB-1 60m, 0.32mm, 1.5um, 5in cage
Agilent 125-1064 Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 6000mm. Film: 3um. Temperature Range: -60 to 260[degree]C.
Agilent 125-1065 Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 6000mm. Film: 5um. Temperature Range: -60 to 260[degree]C.
Agilent 125-1065E Agilent GC Column, DB-1 60m, 0.32mm, 0.5um, 5in cage
Agilent 125-106J Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 6000mm. Film: 1um. Temperature Range: -60 to 300[degree]C.
Agilent 125-106JE Agilent DB-1 60m, 0.53mm, 1.00um, 5 inch cage
Agilent 125-10B5 Agilent GC Column
Agilent 125-10H5 Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 1000mm. Film: 5um. Temperature Range: -60 to 260[degree]C.
Agilent 125-10H5E Agilent GC Column, DB-1 10m, 0.53mm, 5.00um, 5in cage
Agilent 125-10HB Agilent DB-1 HP-1; Ultra-1; SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 1000mm. Film: 2.65um. Temperature Range: -60 to 260[degree]C.
Agilent 125-10HBE Agilent GC Column, DB-1 10m, 0.53mm, 2.65um, 5in cage
Agilent 125-1131 Agilent DB-1HT 30m, 0.53mm, 0.17 um
Agilent 125-1212 Agilent Column, DB-XLB, 0.53mm I.D. x 15m Inner Diameter (mm I.D.): 0.53. Length (meter): 15. Film Thickness (um): 1.50. Temperature Limits (oC): 30 to 320/340, Similar Phases: PE-XLB, MDN-12.
Agilent 125-1232 Agilent Column, DB-XLB, 0.53mm I.D. x 30m Inner Diameter (mm I.D.): 0.53. Length (meter): 30. Film Thickness (um): 1.50. Temperature Limits (oC): 30 to 320/340, Similar Phases: PE-XLB, MDN-12.
Agilent 125-1312 Agilent Column, DB-1301, 0.53mm I.D. x 15m Inner Diameter (mm I.D.): 0.53. Length (meter): 15. Film Thickness (um): 1.00. Temperature Limits (oC): -20 to 260/280, Similar Phases to DB-1301: Rtx-1301, PE-1301, HP-1301.
Agilent 125-1314 Agilent DB-624 15m, 0.53mm, 3.00 um
Agilent 125-1332 Agilent Column, DB-1301, 0.53mm I.D. x 30m Inner Diameter (mm I.D.): 0.53. Length (meter): 30. Film Thickness (um): 1.00. Temperature Limits (oC): -20 to 260/280, Similar Phases to DB-1301: Rtx-1301, PE-1301, HP-1301.
Agilent 125-1333 Agilent DB-1301 Rtx-1301, PE-1301. (6%-cyanopropyl-phenyl) methylpolysiloxane. Low/midpolarity. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 1.5um. Temperature Range: -20 to 260[degree]C.
Agilent 125-1334 Agilent DB*-624 GC Column Intermediate polarity column for the analysis of volatile priority pollutants. Specified in EPA method 524.2. Phase composition: bonded 6% cyanopropyl-phenyl, 94% dimethylpolysiloxane. Temperature range: -20 to 260[degree]C. I.D.:0.53mm. Length: 30m. Film Thickness: 3.00um.
Agilent 125-1334E Agilent DB-624 AT-624. Wound on 127mm cage. Designed for the analysis of volatile priority pollutants. Excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 3um. Temperature Range: -20 to 260[degree]C.
Agilent 125-1334G5 Agilent GC Column
Agilent 125-1364 Agilent DB-624 AT-624. Designed for the analysis of volatile priority pollutants. Excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 6000mm. Film: 3um. Temperature Range: -20 to 260[degree]C.
Agilent 125-1364E Agilent GC Column, DB-1701 60m, 0.32mm, 0.25um, 5in cage
Agilent 125-1374 Agilent DB*-624 GC Column Intermediate polarity column for the analysis of volatile priority pollutants. Specified in EPA method 524.2. Phase composition: bonded 6% cyanopropyl-phenyl, 94% dimethylpolysiloxane. Temperature range: -20 to 260[degree]C. I.D.:0.53mm. Length: 75m. Film Thickness: 3.00um.
Agilent 125-1374E Agilent GC Column
Agilent 125-14A4 Agilent Column, DB-502.2, 0.53mm I.D. x 105m Inner Diameter (mm I.D.): 0.53. Length (meter): 105. Film Thickness (um): 3.00. Temperature Limits (oC): 0 to 260/280, Similar Phases: Rtx-502.2, VOCOL, HP-VOC.
Agilent 125-1704 Agilent Column, DB-17, 0.53mm I.D. x 5m Inner Diameter (mm I.D.): 0.53. Length (meter): 5. Film Thickness (um): 2.00. Temperature Limits (oC): 40 to 260/280, Similar Phases: HP-17, RSL-300, Rtx-50, PE-17, CC-17, 007-17 (MPS-50), SP-2250, HP-50+, SPB-50, ZB-50.
Agilent 125-1710 Agilent DB*-608 GC Column Intermediate polarity column for analyzing chlorinated pesticides and PCBs. For EPA method 608. Phase composition: cross-linked/surface bonded proprietary phase of dimethylphenyl-polysiloxane. Temperature range: 40 to 260[degree]C. ID: 0.53mm. Length: 15m. Film Thickness: 0.83um.
Agilent 125-1711 Agilent DB-17 HP-50+; Rtx-50. (50%-phenyl)-methylpolysiloxane. Midpolarity. Excellent for confirmational analyses. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 1500mm. Film: 0.25um. Temperature Range: 40 to 260[degree]C.
Agilent 125-1712 Agilent DB*-17 GC Column Intermediate polarity column. Use as a confirmation column for steroids, pesticides, herbicides, and drugs. Phase composition: bonded 50% diphenyl, 50% dimethylpolysiloxane. Temperature range: 40 to 260[degree]C. I.D.: 0.53mm. Length: 15m. Film Thickness: 1.00um.
Agilent 125-1713 Agilent DB-17 HP-50+; Rtx-50. (50%-phenyl)-methylpolysiloxane. Midpolarity. Excellent for confirmational analyses. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 1500mm. Film: 1.5um. Temperature Range: 40 to 260[degree]C.
Agilent 125-1717 Agilent DB-17 HP-50+; Rtx-50. (50%-phenyl)-methylpolysiloxane. Midpolarity. Excellent for confirmational analyses. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 1500mm. Film: 0.5um. Temperature Range: 40 to 260[degree]C.
Agilent 125-1730 Agilent DB*-608 GC Column Intermediate polarity column for analyzing chlorinated pesticides and PCBs. For EPA method 608. Phase composition: cross-linked/surface bonded proprietary phase of dimethylphenyl-polysiloxane. Temperature range: 40 to 260[degree]C. ID: 0.53mm. Length: 30m. Film Thickness: 0.83um.
Agilent 125-1731 Agilent DB-17 HP-50+; Rtx-50. (50%-phenyl)-methylpolysiloxane. Midpolarity. Excellent for confirmational analyses. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: 40 to 260[degree]C.
Agilent 125-1731E Agilent GC Column, DB-1 30m, 0.53mm, 1.50um, 5in cage
Agilent 125-1732 Agilent DB*-17 GC Column Intermediate polarity column. Use as a confirmation column for steroids, pesticides, herbicides, and drugs. Phase composition: bonded 50% diphenyl, 50% dimethylpolysiloxane. Temperature range: 40 to 260[degree]C. I.D.: 0.53mm. Length: 30m. Film Thickness: 1.00um.
Agilent 125-1732E Agilent DB-17 30m, 0.53mm, 1.00um, 5 inch cage
Agilent 125-1733 Agilent DB-17 HP-50+; Rtx-50. (50%-phenyl)-methylpolysiloxane. Midpolarity. Excellent for confirmational analyses. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 1.5um. Temperature Range: 40 to 260[degree]C.
Agilent 125-1737 Agilent DB-17 HP-50+; Rtx-50. (50%-phenyl)-methylpolysiloxane. Midpolarity. Excellent for confirmational analyses. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: 40 to 260[degree]C.
Agilent 125-1762 Agilent DB-17 HP-50+; Rtx-50. (50%-phenyl)-methylpolysiloxane. Midpolarity. Excellent for confirmational analyses. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 6000mm. Film: 1um. Temperature Range: 40 to 260[degree]C.
Agilent 125-1912 Agilent DB-35 Rtx-35; SPB-35. (35%-phenyl)-methylpolysiloxane. Midpolarity. Low bleed. Inert to active solutes. Ideal for confirmational analyses. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 1500mm. Film: 1um. Temperature Range: 40 to 280[degree]C.
Agilent 125-1932 Agilent Column, DB-35, 0.53mm I.D. x 30m Inner Diameter (mm I.D.): 0.53. Length (meter): 30. Film Thickness (um): 1.00. Temperature Limits (oC): 40 to 260/280, Similar Phases: Rtx-35, SPB-35, AT-35, Sup-Herb, PE-35.
Agilent 125-1937 Agilent Column, DB-35, 0.53mm I.D. x 30m Inner Diameter (mm I.D.): 0.53. Length (meter): 30. Film Thickness (um): 0.50. Temperature Limits (oC): 40 to 280/300, Similar Phases: Rtx-35, SPB-35, AT-35, Sup-Herb, PE-35.
Agilent 125-2032 Agilent Column, DB-200, 0.53mm I.D. x 30m Inner Diameter (mm I.D.): 0.53. Length (meter): 30. Film Thickness (um): 1.00. Temperature Limits (oC): 30 to 280/300, Similar Phases: Rtx-200.
Agilent 125-2032E Agilent GC Column, HP-1MS, 30m, 0.32mm, 0.25um, 5in cage
Agilent 125-2212 Agilent Column, DB-225, 0.53mm I.D. x 15m Inner Diameter (mm I.D.): 0.53. Length (meter): 15. Film Thickness (um): 1.00. Temperature Limits (oC): 40 to 200/220, Similar Phases: HP-225, SP-2330, CP-Sil 43CB, RSL-500, Rtx-225, BP-225, CB-225, OV-225, PE-225, 007-225.
Agilent 125-2232 Agilent Column, DB-225, 0.53mm I.D. x 30m Inner Diameter (mm I.D.): 0.53. Length (meter): 30. Film Thickness (um): 1.00. Temperature Limits (oC): 40 to 200/220, Similar Phases: HP-225, SP-2330, CP-Sil 43CB, RSL-500, Rtx-225, BP-225, CB-225, OV-225, PE-225, 007-225.
Agilent 125-2232E Agilent GC Column, DB-35MS 30m, 0.32mm, 0.25um, 5in cage
Agilent 125-2237 Agilent DB-225 SP-233; CP-Sil 43 CB. (50%-cyanopropylphenyl)-dimethylpolysiloxane. Mid/high polarity. Excellent for separations of cis- and trans-fatty acid methyl esters. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: 40 to 200[degree]C.
Agilent 125-2312 Agilent Column, DB-23, 0.53mm I.D. x 15m Inner Diameter (mm I.D.): 0.53. Length (meter): 15. Film Thickness (um): 0.50. Temperature Limits (oC): 40 to 230/240, Similar Phases: SP-2330, Rtx-2330, 007-23, AT-Silar, PE-23.
Agilent 125-2814 Agilent Column, DB-2887, 0.53mm I.D. x 10m Inner Diameter (mm I.D.): 0.53. Length (meter): 10. Film Thickness (um): 3.00. Temperature Limits (oC): -60 to 350, Similar Phases: HP-1, Petrocol EX2887, MXT-2887, MXT-1, HT Sim Dist CB, PE-Sim Dist.
Agilent 125-3212 Agilent DB*-FFAP GC Column High polarity column for analysis of volatile fatty acids and phenols. Phase composition: cross-linked/surface bonded nitroterephthalic acid modified polyethylene glycol stationary phase. Temperature range: 40 to 250[degree]C. I.D.: 0.53mm. Length: 15m. Film Thickness: 1.00um.
Agilent 125-3212E Agilent GC Column, DB-5HT 15m, 0.25mm, 0.10um, 5in cage
Agilent 125-3217 Agilent DB-FFAP Stabilwax-DA, HP-FFAP. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 1500mm. Film: 0.5um. Temperature Range: 40 to 250[degree]C.
Agilent 125-3231 Agilent DB-FFAP Stabilwax-DA, HP-FFAP. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: 40 to 250[degree]C.
Agilent 125-3232 Agilent DB*-FFAP GC Column High polarity column for analysis of volatile fatty acids and phenols. Phase composition: cross-linked/surface bonded nitroterephthalic acid modified polyethylene glycol stationary phase. Temperature range: 40 to 250[degree]C. I.D.: 0.53mm. Length: 30m. Film Thickness: 1.00um.
Agilent 125-3232E Agilent GC Column, DB-WAXETR 30m, 0.53mm, 2.00um, 5in cage
Agilent 125-3233 Agilent DB-FFAP Stabilwax-DA, HP-FFAP. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 1.5um. Temperature Range: 40 to 250[degree]C.
Agilent 125-3237 Agilent DB-FFAP Stabilwax-DA, HP-FFAP. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: 40 to 250[degree]C.
Agilent 125-3262 Agilent DB-FFAP Stabilwax-DA, HP-FFAP. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 6000mm. Film: 1um. Temperature Range: 40 to 250[degree]C.
Agilent 125-32H2 Agilent DB-FFAP Stabilwax-DA, HP-FFAP. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 1000mm. Film: 1um. Temperature Range: 40 to 250[degree]C.
Agilent 125-3832 Agilent DB-35ms Rtx-35; SPB-35. Equivalent to (35%-phenyl)-methylpolysiloxane. Midpolarity. Low bleed, excellent inertness for active compounds. Ideal for confirmational analyses. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 1um. Temperature Range: 50 to 320[degree]C.
Agilent 125-3837 Agilent DB-35ms Rtx-35; SPB-35. Equivalent to (35%-phenyl)-methylpolysiloxane. Midpolarity. Low bleed, excellent inertness for active compounds. Ideal for confirmational analyses. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: 50 to 320[degree]C.
Agilent 125-5012 Agilent DB*-5 GC Column Nonpolar. Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95% methylpolysiloxane. Range û60 to 300/320[Degree]C. I.D. 0.53mm. Length 15m. Thickness 1.5um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680, 1625, 1653, 8081, 8141, 8270, 8280.
Agilent 125-5012E Agilent GC Column, DB-1 15m, 0.53mm, 5.00um, 5in cage
Agilent 125-501J Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 1500mm. Film: 1um. Temperature Range: -60 to 300[degree]C.
Agilent 125-501K Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 1500mm. Film: 0.25um. Temperature Range: -60 to 300[degree]C.
Agilent 125-5025 Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 2500mm. Film: 5um. Temperature Range: -60 to 260[degree]C.
Agilent 125-5032 Agilent DB*-5 GC Column Nonpolar. Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95% methylpolysiloxane. Range û60 to 300/320[Degree]C. I.D.0.53mm. Length 30m. Thickness 1.5um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680, 1625, 1653, 8081, 8141, 8270, 8280.
Agilent 125-5034 Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 3um. Temperature Range: -60 to 260[degree]C.
Agilent 125-5034E Agilent DB-5 30m, 0.53mm, 3.00um, 5 inch cage
Agilent 125-5035 Agilent DB*-5 GC Column Nonpolar. Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95% methylpolysiloxane. Range û60 to 300/320[Degree]C. I.D. 0.53mm. Length 30m. Thickness 5um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680, 1625, 1653, 8081, 8141, 8270, 8280.
Agilent 125-5035E Agilent GC Column, DB-1 30m, 0.53mm, 1.00um, 5in cage
Agilent 125-5037 Agilent DB*-5 GC Column Nonpolar. Equivalent to USP phase G27. Phase composition: bonded 5% phenyl, 95% methylpolysiloxane. Range û60 to 300/320[Degree]C. I.D. 0.53um. Length 30m. Thickness 0.5um. For EPA methods 507, 508, 515, 515.2, 524.2, 525, 548.1, 680, 1625, 1653, 8081, 8141, 8270, 8280.
Agilent 125-5037E Agilent GC Column, DB-17 30m, 0.53mm, 0.25um, 5in cage
Agilent 125-503B Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 2.65um. Temperature Range: -60 to 260[degree]C.
Agilent 125-503D Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 0.88um. Temperature Range: -60 to 300[degree]C.
Agilent 125-503J Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 1um. Temperature Range: -60 to 300[degree]C.
Agilent 125-503K Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: -60 to 300[degree]C.
Agilent 125-5062 Agilent Column, DB-5, 0.53mm I.D. x 60m Inner Diameter (mm I.D.): 0.53. Length (meter): 60. Film Thickness (um): 1.50.
Agilent 125-5065 Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 6000mm. Film: 5um. Temperature Range: -60 to 260[degree]C.
Agilent 125-5065E Agilent GC Column, DB-5, 60m, 0.32mm, 1.0um, 5in cage
Agilent 125-50HB Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 1000mm. Film: 2.65um. Temperature Range: -60 to 300[degree]C.
Agilent 125-5512 Agilent Column, DB-5ms, 0.53mm I.D. x 15m Inner Diameter (mm I.D.): 0.53. Length (meter): 15. Film Thickness (um): 1.50. Temperature Limits (oC): -60 to 300/320, Similar Phases: Rtx-5MS, HP-5MS, PTE-5, CP Sil 8 CBms, BPX-5, RH-5ms, HP-5 Trace.
Agilent 125-5532 Agilent DB*-5ms GC Column Nonpolar. MS certified. Improved signal-to-noise ratio for better sensitivity and mass spectral integrity with basic and acidic analytes. Composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Temperature range -60 to 300/350[degree]C. I.D. 0.53mm. Length 30m. Thickness 1.50um.
Agilent 125-5537 Agilent DB-5ms Rtx-5ms. Phenyl Arylene polymer equivalent to (5%-phenyl)-methylpolysiloxane. Non-polar. Low bleed, excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 0.5um. Temperature Range: -60 to 300[degree]C.
Agilent 125-5537G Agilent DuraGuard GC Column Phase: DB-5ms. I.D.: 0.53mm. Length: 30m. Film thickness: 0.50um. Features a built-in length of deactivated fused silica tubing that eliminates problems with peak shape, installation hassles, and leaks associated with unions.
Agilent 125-553J Agilent DB-5ms Rtx-5ms. Phenyl Arylene polymer equivalent to (5%-phenyl)-methylpolysiloxane. Non-polar. Low bleed, excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 1um. Temperature Range: -60 to 325[degree]C.
Agilent 125-6837 Agilent DB*-608 GC Column Intermediate polarity column for analyzing chlorinated pesticides and PCBs. For EPA method 608. Phase composition: cross-linked/surface bonded proprietary phase of dimethylphenyl-polysiloxane. Temperature range: 40 to 260[degree]C. ID: 0.53mm. Length: 30m. Film Thickness: 0.50um.
Agilent 125-7012 Agilent DB*-Wax GC Column High polarity column for the analysis of solvents, aromatics, glycols, essential oils, flavors, fragrances and volatile fatty acids. Phase composition: cross linked/surface bonded polyethylene glycol. Range 20 to 230/240[degree]C. I.D. 0.53mm. Length 15m. Thickness 1um.
Agilent 125-7012E Agilent GC Column, DB-5 15m, 0.53mm, 1.50um, 5in cage
Agilent 125-7017 Agilent Column, DB-WAX, 0.53mm I.D. x 15m Inner Diameter (mm I.D.): 0.53. Length (meter): 15. Film Thickness (um): 0.50. Temperature Limits (oC): 20 to 230/240.
Agilent 125-7031 Agilent DB-WAX HP-20M; SUPELCOWAX 10. Polyethylene glycol. High polarity. Improves resolution of low boiling point analyses. Column-to-column reproducibility. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: 20 to 230[degree]C.
Agilent 125-7032 Agilent DB*-Wax GC Column High polarity column for the analysis of solvents, aromatics, glycols, essential oils, flavors, fragrances and volatile fatty acids. Phase composition: cross linked/surface bonded polyethylene glycol. Range 20 to 230/240[degree]C. I.D. 0.53mm. Length 30m. Thickness 1um.
Agilent 125-7032E Agilent DB-WAX HP-20M; SUPELCOWAX 10. Wound on 127mm cage. Polyethylene glycol. High polarity. Improves resolution of low boiling point analyses. Column-to-column reproducibility. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 1um. Temperature Range: 20 to 230[degree]C.
Agilent 125-7037 Agilent DB*-Wax GC Column High polarity column for the analysis of solvents, aromatics, glycols, essential oils, flavors, fragrances and volatile fatty acids. Phase composition: cross linked/surface bonded polyethylene glycol. Range 20 to 230/240[degree]C. I.D. 0.53mm. Length 30m. Thickness 0.50um.
Agilent 125-7062 Agilent Column, DB-WAX, 0.53mm I.D. x 60m Inner Diameter (mm I.D.): 0.53. Length (meter): 60. Film Thickness (um): 1.00. Temperature Limits (oC): 20 to 230/240.
Agilent 125-7062E Agilent GC Column, DB-WAXETR 60m, 0.32mm, 0.25um, 5in cage
Agilent 125-7312 Agilent Column, DB-WAXetr, 0.53mm I.D. x 15m Inner Diameter (mm I.D.): 0.53. Length (meter): 15. Film Thickness (um): 1.00. Temperature Limits (oC): 30 to 240/260, Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW, 007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX.
Agilent 125-7314 Agilent Column, DB-WAXetr, 0.53mm I.D. x 15m Inner Diameter (mm I.D.): 0.53. Length (meter): 15. Film Thickness (um): 2.00. Temperature Limits (oC): 50 to 230/250, Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW, 007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX.
Agilent 125-7332 Agilent Column, DB-WAXetr, 0.53mm I.D. x 30m Inner Diameter (mm I.D.): 0.53. Length (meter): 30. Film Thickness (um): 1.00. Temperature Limits (oC): 30 to 240/260, Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW, 007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX.
Agilent 125-7332E Agilent GC Column, DB-5 30m, 0.53mm, 5.00um, 5in cage
Agilent 125-7333 Agilent DB-WAXetr HP-20M; SUPELCOWAX 10. Polyethylene glycol. Extended temperature range. High polarity. Excellent column-to-column repeatability. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 1.5um. Temperature Range: 30 to 230[degree]C.
Agilent 125-7334 Agilent Column, DB-WAXetr, 0.53mm I.D. x 30m Inner Diameter (mm I.D.): 0.53. Length (meter): 30. Film Thickness (um): 2.00. Temperature Limits (oC): 50 to 230/250, Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW, 007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX.
Agilent 125-7334E Agilent GC Column, DB-5 30m, 0.53mm, 0.50um, 5in cage
Agilent 125-7362 Agilent Column, DB-WAXetr, 0.53mm I.D. x 60m Inner Diameter (mm I.D.): 0.53. Length (meter): 60. Film Thickness (um): 1.00. Temperature Limits (oC): 30 to 240/260, Similar Phases: HP-20M, SUPELCOWAX 10, CP-WAX 52CB, SUPEROX II, CB-WAX, STABILWAX, BP-20, PE-CW, 007-CW, Carbowax, HP-Innowax, RH-WAX, ZB-WAX.
Agilent 125-7732 Agilent DB*-1701P Capillary Column A low/midpolarity column for analyzing organochlorine pesticides. Tested using an ECD detector to ensure CLP performance criteria for p,p'-DDT breakdown. Phase composition: bonded 14% cyanpropylphenyl, 86% methylpolysiloxane. Temperature range: -20 to 260[degree]C.
Agilent 125-9134 Agilent DB-ALC1 Rtx-BAC1. Provides reliable blood alcohol analysis. Bonded and cross-linked. 0.53mm ID. Length: 3000mm. Film: 3um. Temperature Range: 20 to 260[degree]C.
Agilent 125-9134E Agilent Automatic Static Headspace Systems DB-ALC1 and DB-ALC2 results are complete in just 2 minutes, reducing run time by one-third compared to other blood alcohol analysis columns. TodayÆs automated static headspace systems (SHS) utilize multi-sample equilibration ovens.
Agilent 125-9234 Agilent DB-ALC2 Rtx-BAC2. Provides reliable blood alcohol analysis. Bonded and cross-linked. 0.53mm ID. Length: 3000mm. Film: 2um. Temperature Range: 20 to 260[degree]C.
Agilent 126-1012 Agilent Column, DB-1, 0.05mm I.D. x 10m Inner Diameter (mm I.D.): 0.05. Length (meter): 10. Film Thickness (um): 0.05. Temperature Limits (oC): -60 to 325/350.
Agilent 126-1013 Agilent Column, DB-1, 0.05mm I.D. x 10m Inner Diameter (mm I.D.): 0.05. Length (meter): 10. Film Thickness (um): 0.20. Temperature Limits (oC): -60 to 325/350.
Agilent 126-1713 Agilent Column, DB-17, 0.05mm I.D. x 10m Inner Diameter (mm I.D.): 0.05. Length (meter): 10. Film Thickness (um): 0.10. Temperature Limits (oC): 40 to 280/300, Similar Phases: HP-17, RSL-300, Rtx-50, PE-17, CC-17, 007-17 (MPS-50), SP-2250, HP-50+, SPB-50, ZB-50.
Agilent 126-7012 Agilent Column, DB-WAX, 0.05mm I.D. x 10m Inner Diameter (mm I.D.): 0.05. Length (meter): 10. Film Thickness (um): 0.05. Temperature Limits (oC): 20 to 250/260.
Agilent 126-7013 Agilent Column, DB-WAX, 0.05mm I.D. x 10m Inner Diameter (mm I.D.): 0.05. Length (meter): 10. Film Thickness (um): 0.10. Temperature Limits (oC): 20 to 250/260.
Agilent 127-0113 Agilent DB-1ms HP-1ms. 100% dimethylpolysiloxane, identical selectivity to DB-1. Non-polar. General purpose column with low bleed characteristics. Bonded and cross-linked. Solvent rinsable. 0.1mm ID. Length: 1000mm. Film: 0.4um. Temperature Range: -60 to 340[degree]C.
Agilent 127-0113E Agilent GC Column, DB-5HT 15m, 0.32mm, 0.10um, 5in cage
Agilent 127-0722 Agilent DB-1701 SPB-1701, CP-Sil 19 CB. (14%-Cyanopropyl-phenyl)-methylpolysiloxane. Low to mid polarity. Sovent rinsable. Bonded and cross-linked. 0.1mm ID. Length: 2000mm. Film: 0.1um. Temperature Range: -20 to 280[degree]C.
Agilent 127-0723 Agilent DB-1701 SPB-1701, CP-Sil 19 CB. (14%-Cyanopropyl-phenyl)-methylpolysiloxane. Low to mid polarity. Sovent rinsable. Bonded and cross-linked. 0.1mm ID. Length: 2000mm. Film: 0.4um. Temperature Range: -20 to 280[degree]C.
Agilent 127-0723E Agilent GC Column, DB-210 30m, 0.25mm, 0.25um, 5in cage
Agilent 127-100A Agilent DB-1 HP-1, Ultra-1, SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.1mm ID. Length: 500mm. Film: 0.12um. Temperature Range: -60 to 325[degree]C.
Agilent 127-1012E Agilent DB-1 HP-1, Ultra-1, SPB-1. Wound on 127mm cage. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.1mm ID. Length: 1000mm. Film: 0.1um. Temperature Range: -60 to 325[degree]C.
Agilent 127-1013 Agilent Column, DB-1, 0.10mm I.D. x 10m Inner Diameter (mm I.D.): 0.10. Length (meter): 10. Film Thickness (um): 0.40. Temperature Limits (oC): -60 to 325/350.
Agilent 127-1013E Agilent DB-1 HP-1, Ultra-1, SPB-1. Wound on 127mm cage. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.1mm ID. Length: 1000mm. Film: 0.4um. Temperature Range: -60 to 325[degree]C.
Agilent 127-1022 Agilent Column, DB-1, 0.10mm I.D. x 20m Inner Diameter (mm I.D.): 0.10. Length (meter): 20. Film Thickness (um): 0.10. Temperature Limits (oC): -60 to 325/350.
Agilent 127-1023 Agilent DB*-1 GC Column A nonpolar column for compounds with similar polarities and larger differences in boiling points. Phase composition: 100% bonded dimethylpolysiloxane. Specified in EPA methods 504, 505, 515, 515.2, and 551. Range: -60 to 325/350[degree]C. ID 0.10mm. Length 20m. Thickness 0.40um.
Agilent 127-1023E Agilent GC Column, DB-1301 30m, 0.25mm, 1.00um, 5in cage
Agilent 127-1043 Agilent DB-1 HP-1, Ultra-1, SPB-1. 100% dimethylpolysiloxane. Non-polar. Excellent general purpose column with wide range of applications. Bonded and cross-linked. Solvent rinsable. 0.1mm ID. Length: 4000mm. Film: 0.4um. Temperature Range: -60 to 325[degree]C.
Agilent 127-1046 Agilent Column, DB-1, 0.10mm I.D. x 40m Inner Diameter (mm I.D.): 0.10. Length (meter): 40. Film Thickness (um): 0.20. Temperature Limits (oC): -60 to 325/350.
Agilent 127-1046E Agilent DB-1 40m, 0.10mm, 0.20um, 5 inch cage
Agilent 127-1713 Agilent DB-17 HP-50+; Rtx-50. (50%-phenyl)-methylpolysiloxane. Midpolarity. Excellent for confirmational analyses. Bonded and cross-linked. Solvent rinsable. 0.1mm ID. Length: 1000mm. Film: 0.2um. Temperature Range: 40 to 260[degree]C.
Agilent 127-2222 Agilent DB-225 SP-233; CP-Sil 43 CB. (50%-cyanopropylphenyl)-dimethylpolysiloxane. Mid/high polarity. Excellent for separations of cis- and trans-fatty acid methyl esters. Bonded and cross-linked. Solvent rinsable. 0.1mm ID. Length: 2000mm. Film: 0.1um. Temperature Range: 40 to 220[degree]C.
Agilent 127-3212 Agilent HP-FFAP Columns Designed primarily for the analysis of organic acids, free fatty acids, or samples that require quantitation of acidic impurities. The stationary phase is modified with acid to provide a very inert column that can accomodate the demanding analysis of acids dissolved in water.
Agilent 127-32H2 Agilent HP-FFAP Columns Designed primarily for the analysis of organic acids, free fatty acids, or samples that require quantitation of acidic impurities. The stationary phase is modified with acid to provide a very inert column that can accomodate the demanding analysis of acids dissolved in water.
Agilent 127-5012 Agilent Column, DB-5, 0.10mm I.D. x 10m Inner Diameter (mm I.D.): 0.10. Length (meter): 10. Film Thickness (um): 0.10.
Agilent 127-5012E Agilent GC Column, DB-1701 15m, 0.53mm, 1.00um, 5in cage
Agilent 127-5013 Agilent Column, DB-5, 0.10mm I.D. x 10m Inner Diameter (mm I.D.): 0.10. Length (meter): 10. Film Thickness (um): 0.40.
Agilent 127-501E Agilent DB-5 HP-5; Ultra-2; SP-B-5. Wound on 127mm cage. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.1mm ID. Length: 1000mm. Film: 0.17um. Temperature Range: -60 to 325[degree]C.
Agilent 127-501EE Agilent DB-5 10m, 0.10mm, 0.17um, 5 inch cage
Agilent 127-501N Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.1mm ID. Length: 1000mm. Film: 0.33um. Temperature Range: -60 to 325[degree]C.
Agilent 127-5022 Agilent Column, DB-5, 0.10mm I.D. x 20m Inner Diameter (mm I.D.): 0.10. Length (meter): 20. Film Thickness (um): 0.10.
Agilent 127-5022E Agilent GC Column, DB-1 20m, 0.10mm, 0.40um, 5in cage
Agilent 127-5023 Agilent Column, DB-5, 0.10mm I.D. x 20m Inner Diameter (mm I.D.): 0.10. Length (meter): 20. Film Thickness (um): 0.40.
Agilent 127-7012 Agilent DB-WAX HP-20M; SUPELCOWAX 10. Polyethylene glycol. High polarity. Improves resolution of low boiling point analyses. Column-to-column reproducibility. Bonded and cross-linked. Solvent rinsable. 0.1mm ID. Length: 1000mm. Film: 0.1um. Temperature Range: 20 to 250[degree]C.
Agilent 127-7012E Agilent DB-WAX HP-20M. Wound on 127mm cage. Polyethylene glycol. High polarity. Improves resolution of low boiling point analyses. Column-to-column reproducibility. Bonded and cross-linked. Solvent rinsable. With 127mm cage. 0.1mm ID. Length: 1000mm. Film: 0.1um. Temperature Range: 20 to 250[degree]C.
Agilent 127-7013 Agilent DB-WAX HP-20M; SUPELCOWAX 10. Polyethylene glycol. High polarity. Improves resolution of low boiling point analyses. Column-to-column reproducibility. Bonded and cross-linked. Solvent rinsable. 0.1mm ID. Length: 1000mm. Film: 0.2um. Temperature Range: 20 to 240[degree]C.
Agilent 127-7022 Agilent Column, DB-WAX, 0.10mm I.D. x 20m Inner Diameter (mm I.D.): 0.10. Length (meter): 20. Film Thickness (um): 0.10. Temperature Limits (oC): 20 to 250/260.
Agilent 127-7023 Agilent Column, DB-WAX, 0.10mm I.D. x 20m Inner Diameter (mm I.D.): 0.10. Length (meter): 20. Film Thickness (um): 0.20. Temperature Limits (oC): 20 to 250/260.
Agilent 127-7023E Agilent GC Column, DB-5 20m, 0.10mm, 0.10um, 5in cage
Agilent 127-7023FF Agilent DB-WAX 20m x 0.1mm ID, 0.2um, FF Test.
Agilent 128-0122E Agilent GC Column, HP-1MS 25m, 0.2mm, 0.33um, 5in cage
Agilent 128-1012 Agilent Column, DB-1, 0.20mm I.D. x 12m Inner Diameter (mm I.D.): 0.20. Length (meter): 12. Film Thickness (um): 0.33. Temperature Limits (oC): -60 to 325/350.
Agilent 128-1022 Agilent Column, DB-1, 0.20mm I.D. x 25m Inner Diameter (mm I.D.): 0.20. Length (meter): 25. Film Thickness (um): 0.33. Temperature Limits (oC): -60 to 325/350.
Agilent 128-1052 Agilent Column, DB-1, 0.20mm I.D. x 50m Inner Diameter (mm I.D.): 0.20. Length (meter): 50. Film Thickness (um): 0.33. Temperature Limits (oC): -60 to 325/350.
Agilent 128-1056 Agilent Column, DB-Petro, 0.20mm I.D. x 50m Inner Diameter (mm I.D.): 0.20. Length (meter): 50. Film Thickness (um): 0.50. Temperature Limits (oC): -60 to 325/350, Similar Phases: Petrocol DH, HP-PONA, SPB-1, 007-1, Rtx-1, MXT-1, PE-PONA.
Agilent 128-1212 Agilent DB-XLB MDN-12. Exceptionally low bleed. Low polarity. Designed to inhibit column bleed at high temperatures. Excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.2mm ID. Length: 1200mm. Film: 0.33um. Temperature Range: 30 to 340[degree]C.
Agilent 128-1212E Agilent GC Column, DB-XLB 12m, 0.20mm, 0.33um, 5in cage
Agilent 128-1222 Agilent DB-XLB MDN-12. Exceptionally low bleed. Low polarity. Designed to inhibit column bleed at high temperatures. Excellent inertness for active compounds. Bonded and cross-linked. Solvent rinsable. 0.2mm ID. Length: 2500mm. Film: 0.33um. Temperature Range: 30 to 340[degree]C.
Agilent 128-1324 Agilent Column, DB-624, 0.20mm I.D. x 25m Diameter (mm I.D.): 0.20. Inner Length (meter): 25. Film Thickness (um): 1.12. Temperature Limits (oC): -20 to 260, Similar Phases: VOCOL, NON-PAKD, AT-624, Rtx-Volatiles, Rtx-502.2, PE-624, PE-502, 007-624, 007-502, HP-624, CP-624, ZB-624.
Agilent 128-1324E Agilent GC Column, DB-624 20m, 0.18mm, 1.00um, 5in cage
Agilent 128-3812 Agilent DB-35ms Rtx-35; SPB-35. Equivalent to (35%-phenyl)-methylpolysiloxane. Midpolarity. Low bleed, excellent inertness for active compounds. Ideal for confirmational analyses. Bonded and cross-linked. Solvent rinsable. 0.2mm ID. Length: 1500mm. Film: 0.33um. Temperature Range: 50 to 340[degree]C.
Agilent 128-3822 Agilent DB-35ms Rtx-35; SPB-35. Equivalent to (35%-phenyl)-methylpolysiloxane. Midpolarity. Low bleed, excellent inertness for active compounds. Ideal for confirmational analyses. Bonded and cross-linked. Solvent rinsable. 0.2mm ID. Length: 2500mm. Film: 0.33um. Temperature Range: 50 to 340[degree]C.
Agilent 128-3822E Agilent GC Column, DB-1MS 25m, 0.20mm, 0.33um, 5in cage
Agilent 128-5012 Agilent Column, DB-5, 0.20mm I.D. x 12m Inner Diameter (mm I.D.): 0.20. Length (meter): 12. Film Thickness (um): 0.33.
Agilent 128-5022 Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.2mm ID. Length: 2500mm. Film: 0.33um. Temperature Range: -60 to 325[degree]C.
Agilent 128-5022E Agilent GC Column, DB-1MS, 10m, 0.10mm, 0.40um, 5in cage
Agilent 128-5052 Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.2mm ID. Length: 5000mm. Film: 0.33um. Temperature Range: -60 to 325[degree]C.
Agilent 128-5052E Agilent GC Column, HP-PLOT Al2O3 KCL 30m, 0.25mm, 5in cage
Agilent 128-50H7 Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.2mm ID. Length: 1500mm. Film: 0.2um. Temperature Range: -60 to 325[degree]C.
Agilent 128-5522 Agilent Column, DB-5ms, 0.20mm I.D. x 25m Inner Diameter (mm I.D.): 0.20. Length (meter): 25. Film Thickness (um): 0.33. Temperature Limits (oC): -60 to 325/350, Similar Phases: Rtx-5MS, HP-5MS, PTE-5, CP Sil 8 CBms, BPX-5, RH-5ms, HP-5 Trace.
Agilent 128-5552 Agilent Column, DB-5ms, 0.20mm I.D. x 50m Inner Diameter (mm I.D.): 0.20. Length (meter): 50. Film Thickness (um): 0.33. Temperature Limits (oC): -60 to 325/350, Similar Phases: Rtx-5MS, HP-5MS, PTE-5, CP Sil 8 CBms, BPX-5, RH-5ms, HP-5 Trace.
Agilent 128-7032 Agilent DB-WAX HP-20M; SUPELCOWAX 10. Polyethylene glycol. High polarity. Improves resolution of low boiling point analyses. Column-to-column reproducibility. Bonded and cross-linked. Solvent rinsable. 0.2mm ID. Length: 2500mm. Film: 0.2um. Temperature Range: 20 to 230[degree]C.
Agilent 128-7323 Agilent DB-WAXetr HP-20M; SUPELCOWAX 10. Polyethylene glycol. Extended temperature range. High polarity. Excellent column-to-column repeatability. Bonded and cross-linked. Solvent rinsable. 0.2mm ID. Length: 2500mm. Film: 0.4um. Temperature Range: 30 to 230[degree]C.
Agilent 128-8522 Agilent DB-5ms-EVDX Equivalent to (5%-phenyl)-methylpolysiloxane. Low bleed for GC/MS analysis. Bonded and cross-linked. Solvent rinsable. 0.2mm ID. Length: 2500mm. Film: 0.33um. Temperature Range: -60 to 325[degree]C.
Agilent 12A-5015 Agilent DB-5 HP-5; Ultra-2; SP-B-5. (5%-phenyl)-methylpolysiloxane. Non-polar general purpose column with wide range of applications. Low bleed. Bonded and cross-linked. Solvent rinsable. 0.15mm ID. Length: 1000mm. Film: 1.2um. Temperature Range: -60 to 300[degree]C.
Agilent 12A-5015E Agilent GC Column, DB-5 10m, 0.10mm, 1.2um, 5in cage
Agilent 1300502506 Agilent Tube Probe to 6-port valve, deactivated.
Agilent 145-1001 Agilent Column, DB-HT Sim Dis, 0.53mm I.D. x 5m Inner Diameter (mm I.D.): 0.53. Length (meter): 5. Film Thickness (um): 0.15. Temperature Limits (oC): -6 to 400, Similar Phases: Petrocol EX2887, CP-SimDist Ultimetal, MXT-2887, Rtx-2887, AC Controls High Temp Sim Dist, AT-2887.
Agilent 145-1011 Agilent DB-PS1, ProSteel Excellent inertness. Available in wide variety of stationary phases. Ideal for high temperature analysis and process applications. Bonded and cross-linked. 0.53mm ID. Length: 1500mm. Film: 0.15um. Temperature Range: -60 to 340[degree]C.
Agilent 145-1334 Agilent Column, DB-PS624, 0.53mm I.D. x 30m Inner Diameter (mm.I.D.): 0.53. Length (meter): 30. Film Thickness (um): 3.00. Temperature Limits (oC): -20 to 260.
Agilent 145-2814 Agilent DB-P2887, ProSteel Excellent inertness. Available in wide variety of stationary phases. Ideal for high temperature analysis and process applications. Bonded and cross-linked. 0.53mm ID. Length: 1000mm. Film: 3um. Temperature Range: -60 to 350[degree]C.
Agilent 145-7032 Agilent DB-PSWAX, ProSteel Excellent inertness. Available in wide variety of stationary phases. Ideal for high temperature analysis and process applications. Bonded and cross-linked. 0.53mm ID. Length: 3000mm. Film: 1um. Temperature Range: 20 to 230[degree]C.
Agilent 1460-1914 Agilent HP GCD/5971/72 MSD Parts and Supplies Column wireform hanger. Kits.
Agilent 1530-2163 Agilent GC Valves and Loops Compatible with HP 5890/6890 Tube, 1/16 in. with 1/8 in flare, stainless steel, 360 mm long.
Agilent 1530-2167 Agilent GC Valves and Loops Compatible with HP 5890/6890 Tube, 1/16 in. with 1/8 in. flare stainless steel, 520 mm long.
Agilent 160-1010-1 Agilent Fused Silica Tubing, Deactivated I.D. 0.1 mm, O.D. 0.19 mm Deactivated fused silica tubing has a nonpolar chemical surface treatment - the preferred choice for most applications. J & W tests to ensure deactivated tubing inertness.
Agilent 160-1010-10 Agilent Fused Silica Tubing, Deactivated I.D. 0.1 mm, O.D. 0.19 mm Deactivated fused silica tubing has a nonpolar chemical surface treatment - the preferred choice for most applications. J & W tests to ensure deactivated tubing inertness.
Agilent 160-1010-5 Agilent Fused Silica Tubing, Deactivated I.D. 0.1 mm, O.D. 0.19 mm Deactivated fused silica tubing has a nonpolar chemical surface treatment - the preferred choice for most applications. J & W tests to ensure deactivated tubing inertness.
Agilent 160-2200-10 Agilent Fused Silica Tubing, Undeactivated, 10 m, 0.20 mm I.D. Fused Silica Tubing, Undeactivated, Length: 10 m, Inner Diameter: 0.20 mm.
Agilent 160-2200-5 Agilent Fused Silica Tubing, Undeactivated, 5 m, 0.20 mm I.D. Fused Silica Tubing, Undeactivated, Length: 5 m, Inner Diameter: 0.20 mm.
Agilent 160-2205-1 Agilent Fused Silica Tubing, Deactivated, 1 m, 0.20 mm I.D. Fused Silica Tubing, Deactivated, Length: 1 m, Inner Diameter: 0.20 mm.
Agilent 160-2205-10 Agilent Fused Silica Tubing, Deactivated, 10 m, 0.20 mm I.D. Fused Silica Tubing, Deactivated, Length: 10 m, Inner Diameter: 0.20 mm.
Agilent 160-2205-5 Agilent Fused Silica Tubing, Deactivated, 5 m, 0.20 mm I.D. Fused Silica Tubing, Deactivated, Length: 5 m, Inner Diameter: 0.20 mm.
Agilent 160-2250-10 Agilent Fused Silica Tubing, Undeactivated, 10 m, 0.25 mm I.D. Fused Silica Tubing, Undeactivated, Length: 10 m, Inner Diameter: 0.25 mm.
Agilent 160-2250-5 Agilent Fused Silica Tubing, Undeactivated, 5 m, 0.25 mm I.D. Fused Silica Tubing, Undeactivated, Length: 5 m, Inner Diameter: 0.25 mm.
Agilent 160-2255-1 Agilent Fused Silica Tubing, Deactivated, 1 m, 0.25 mm I.D. Fused Silica Tubing, Deactivated, Length: 1 m, Inner Diameter: 0.25 mm.
Agilent 160-2255-10 Agilent Capillary Guard Column Analytical column for use as a guard column. I.D.: 0.25mm.
Agilent 160-2255-30 Agilent Fused Silica Tubing, Deactivated, 30 m, 0.25 mm I.D. Fused Silica Tubing, Deactivated, Length: 30 m, Inner Diameter: 0.25 mm.
Agilent 160-2255-5 Agilent Fused Silica Tubing, Deactivated, 5 m, 0.25 mm I.D. Fused Silica Tubing, Deactivated, Length: 5 m, Inner Diameter: 0.25 mm.
Agilent 160-2320-10 Agilent Fused Silica Tubing, Undeactivated, 10 m, 0.32 mm I.D. Fused Silica Tubing, Undeactivated, Length: 10 m, Inner Diameter: 0.32 mm.
Agilent 160-2320-5 Agilent Fused Silica Tubing, Undeactivated, 5 m, 0.32 mm I.D. Fused Silica Tubing, Undeactivated, Length: 5 m, Inner Diameter: 0.32 mm.
Agilent 160-2325-1 Agilent Fused Silica Tubing, Deactivated, 1 m, 0.32 mm I.D. Fused Silica Tubing, Deactivated, Length: 1 m, Inner Diameter: 0.32 mm.
Agilent 160-2325-30 Agilent Fused Silica Tubing, Deactivated, 30 m, 0.32 mm I.D. Fused Silica Tubing, Deactivated, Length: 30 m, Inner Diameter: 0.32 mm.
Agilent 160-2325-5 Agilent Fused Silica Tubing, Deactivated, 5 m, 0.32 mm I.D. Fused Silica Tubing, Deactivated, Length: 5 m, Inner Diameter: 0.32 mm.
Agilent 160-2450-5 Agilent Fused Silica Tubing, Undeactivated, 5 m, 0.45 mm I.D. Fused Silica Tubing, Undeactivated, Length: 5 m, Inner Diameter: 0.45 mm.
Agilent 160-2455-1 Agilent Fused Silica Tubing, Deactivated, 1 m, 0.45 mm I.D. Fused Silica Tubing, Deactivated, Length: 1 m, Inner Diameter: 0.45 mm.
Agilent 160-2455-10 Agilent Fused Silica Tubing, Deactivated, 10 m, 0.45 mm I.D. Fused Silica Tubing, Deactivated, Length: 10 m, Inner Diameter: 0.45 mm.
Agilent 160-2455-5 Agilent Fused Silica Tubing, Deactivated, 5 m, 0.45 mm I.D. Fused Silica Tubing, Deactivated, Length: 5 m, Inner Diameter: 0.45 mm.
Agilent 160-2530-10 Agilent Fused Silica Tubing, Undeactivated, 10 m, 0.53 mm I.D. Fused Silica Tubing, Undeactivated, Length: 10 m, Inner Diameter: 0.53 mm.
Agilent 160-2530-5 Agilent Fused Silica Tubing, Undeactivated, 5 m, 0.53 mm I.D. Fused Silica Tubing, Undeactivated, Length: 5 m, Inner Diameter: 0.53 mm.
Agilent 160-2535-1 Agilent Fused Silica Tubing, Deactivated, 1 m, 0.53 mm I.D. Fused Silica Tubing, Deactivated, Length: 1 m, Inner Diameter: 0.53 mm.
Agilent 160-2535-10 Agilent Fused Silica Tubing, Deactivated, 10 m, 0.53 mm I.D. Fused Silica Tubing, Deactivated, Length: 10 m, Inner Diameter: 0.53 mm.
Agilent 160-2535-30 Agilent Fused Silica Tubing, Deactivated, 30 m, 0.53 mm I.D. Fused Silica Tubing, Deactivated, Length: 30 m, Inner Diameter: 0.53 mm.
Agilent 160-2535-5 Agilent Fused Silica Tubing, Deactivated, 5 m, 0.53 mm I.D. Fused Silica Tubing, Deactivated, Length: 5 m, Inner Diameter: 0.53 mm.
Agilent 160-2610-10 Agilent Fused Silica Tubing, Undeactivated, 10 m, 0.18 mm I.D. Fused Silica Tubing, Undeactivated, Length: 10 m, Inner Diameter: 0.18 mm.
Agilent 160-2610-5 Agilent Fused Silica Tubing, Undeactivated, 5 m, 0.18 mm I.D. Fused Silica Tubing, Undeactivated, Length: 5 m, Inner Diameter: 0.18 mm.
Agilent 160-2615-1 Agilent Fused Silica Tubing, Deactivated, 1 m, 0.18 mm I.D. Fused Silica Tubing, Deactivated, Length: 1 m, Inner Diameter: 0.18 mm.
Agilent 160-2615-10 Agilent Fused Silica Tubing, Deactivated, 10 m, 0.18 mm I.D. Fused Silica Tubing, Deactivated, Length: 10 m, Inner Diameter: 0.18 mm.
Agilent 160-2615-5 Agilent Fused Silica Tubing, Deactivated, 5 m, 0.18 mm I.D. Fused Silica Tubing, Deactivated, Length: 5 m, Inner Diameter: 0.18 mm.
Agilent 160-2634-10 Agilent Fused Silica Tubing, Undeactivated, 10 m, 0.10 mm I.D. Fused Silica Tubing, Undeactivated, Length: 10 m, Inner Diameter: 0.10 mm.
Agilent 160-2634-5 Agilent Fused Silica Tubing, Undeactivated, 5 m, 0.10 mm I.D. Fused Silica Tubing, Undeactivated, Length: 5 m, Inner Diameter: 0.10 mm.
Agilent 160-2635-1 Agilent Fused Silica Tubing, Deactivated, 1 m, 0.10 mm I.D. Fused Silica Tubing, Deactivated, Length: 1 m, Inner Diameter: 0.10 mm.
Agilent 160-2635-10 Agilent Fused Silica Tubing, Deactivated, 10 m, 0.10 mm I.D. Fused Silica Tubing, Deactivated, Length: 10 m, Inner Diameter: 0.10 mm.
Agilent 160-2635-5 Agilent Fused Silica Tubing, Deactivated, 5 m, 0.10 mm I.D. Fused Silica Tubing, Deactivated, Length: 5 m, Inner Diameter: 0.10 mm.
Agilent 160-2644-10 Agilent Fused Silica Tubing, Undeactivated, 10 m, 0.075 mm I.D. Fused Silica Tubing, Undeactivated, Length: 10 m, Inner Diameter: 0.075 mm.
Agilent 160-2644-5 Agilent Fused Silica Tubing, Undeactivated, 5 m, 0.075 mm I.D. Fused Silica Tubing, Undeactivated, Length: 5 m, Inner Diameter: 0.075 mm.
Agilent 160-2650-10 Agilent Fused Silica Tubing, Undeactivated, 10 m, 0.05 mm I.D. Fused Silica Tubing, Undeactivated, Length: 10 m, Inner Diameter: 0.05 mm.
Agilent 160-2650-5 Agilent Fused Silica Tubing, Undeactivated, 5 m, 0.05 mm I.D. Fused Silica Tubing, Undeactivated, Length: 5 m, Inner Diameter: 0.05 mm.
Agilent 160-2655-1 Agilent Fused Silica Tubing, Deactivated, 1 m, 0.05 mm I.D. Fused Silica Tubing, Deactivated, Length: 1 m, Inner Diameter: 0.05 mm.
Agilent 160-2655-10 Agilent Fused Silica Tubing, Deactivated, 10 m, 0.05 mm I.D. Fused Silica Tubing, Deactivated, Length: 10 m, Inner Diameter: 0.05 mm.
Agilent 160-2655-5 Agilent Fused Silica Tubing, Deactivated, 5 m, 0.05 mm I.D. Fused Silica Tubing, Deactivated, Length: 5 m, Inner Diameter: 0.05 mm.
Agilent 160-2660-5 Agilent Fused Silica Tubing, Undeactivated, 5 m, 0.02 mm I.D. Fused Silica Tubing, Undeactivated, Length: 5 m, Inner Diameter: 0.02 mm.
Agilent 160-2815-5 Agilent High Temperature Fused Silica, Deactivated, Tubing, 5 m, 0.05 mm I.D. High Temperature Fused Silica, Deactivated, Tubing, Length: 5 m, Inner Diameter: 0.05 mm.
Agilent 160-2825-5 Agilent High Temperature Fused Silica, Deactivated, Tubing, 5 m, 0.10 mm I.D. High Temperature Fused Silica, Deactivated, Tubing, Length: 5 m, Inner Diameter: 0.10 mm.
Agilent 160-2845-10 Agilent High Temperature Fused Silica, Deactivated, Tubing, 10 m, 0.25 mm I.D. High Temperature Fused Silica, Deactivated, Tubing, Length: 10 m, Inner Diameter: 0.25 mm.
Agilent 160-2845-5 Agilent High Temperature Fused Silica, Deactivated, Tubing, 5 m, 0.25 mm I.D. High Temperature Fused Silica, Deactivated, Tubing, Length: 5 m, Inner Diameter: 0.25 mm.
Agilent 160-2855-10 Agilent High Temperature Fused Silica, Deactivated, Tubing, 10 m, 0.32 mm I.D. High Temperature Fused Silica, Deactivated, Tubing, Length: 10 m, Inner Diameter: 0.32 mm.
Agilent 160-2855-5 Agilent High Temperature Fused Silica, Deactivated, Tubing, 5 m, 0.32 mm I.D. High Temperature Fused Silica, Deactivated, Tubing, Length: 5 m, Inner Diameter: 0.32 mm.
Agilent 160-2865-10 Agilent High Temperature Fused Silica, Deactivated, Tubing, 10 m, 0.53 mm I.D. High Temperature Fused Silica, Deactivated, Tubing, Length: 10 m, Inner Diameter: 0.53 mm.
Agilent 160-2865-5 Agilent High Temperature Fused Silica, Deactivated, Tubing, 5 m, 0.53 mm I.D. High Temperature Fused Silica, Deactivated, Tubing, Length: 5 m, Inner Diameter: 0.53 mm.
Agilent 160-4535-5 Agilent ProSteel Stainless Steel Tubing, Deactivated, 5 m, 0.53 mm I.D. ProSteel Stainless Steel Tubing, Deactivated, Length: 5 m, Inner Diameter: 0.53 mm.
Agilent 18596-40015 Agilent Files, Cutters, and Replacement Blades Tube cutter (1/8 to 5/8 in. od tubing).
Agilent 18710-20119 Agilent HP 5890 Detector Supplies Jet, adaptable packed (0.46mm ID tip).
Agilent 18710-60170 Agilent HP 5880 Detector Supplies Flame Ionization Detector (FID). Performance evaluation sample, FID solution of 0.033% C14, C15, and C16 normal alkanes in hexane. Three 0.5 ml ampoules.
Agilent 18711-60060 Agilent HP 5890 Detector Supplies TCD Performance Evaluation Sample: C14, C15, and C16 (0.3%) in hexane.
Agilent 18713-60040 Agilent HP 5880 Detector Supplies Electron Capture Detector (ECD). Performance evaluation sample, ECD.
Agilent 18713-60050 Agilent HP 5880 Detector Supplies Electron Capture Detector (ECD). Wipe test kit, each kit will perform test four times.
Agilent 18740-20800 Agilent HP 5890 Split/Splitless Multimode Inlet Split/Splitless Inlet Parts. Reducing nut.
Agilent 18740-20880 Agilent HP 6890 Split/Splitless Inlet Supplies Split/Splitless Inlet Supplies. Stainless steel seal.
Agilent 18740-20950 Agilent HP 5890 Detector Supplies TCD column adapter seal.
Agilent 18740-20960 Agilent Adapter Seal For 1/8" FID. TCD capillary column adapter.
Agilent 18740-60830 Agilent HP 5890 Packed Column Inlet Supplies Septum-Purged Packed Column Inlet. Headspace septum retainer nut.
Agilent 18740-60835 Agilent HP 5890 Packed Column Inlet Supplies Septum-Purged Packed Column Inlet. Septum retainer nut.
Agilent 18740-60840 Agilent Split Liner with Cup for Capillary Inlet Systems 4mm ID. Volume: 800uL. For particulate samples. Retains non-volatile contaminants. Borosilicate glass. Column packing (10% OV-1 on 80/100 Chromosorb), has a higher capacity for boiling than glass wool. Not for use with electronic pressure control.
Agilent 18740-80190 Agilent Split Liner with Cup for Capillary Inlet Systems 4mm ID. Volume: 800uL. For a wide range of molecular analyses. Borosilicate glass.
Agilent 18740-80200 Agilent Inlet Liners Capillary Inlet System Liners. Direct Liner. ID: 1.5 mm. Volume: 140 uL. Glass Type: Borosilicate. Glass wool packing: No. Typical applications: Small (>0.5ul) volumes, depending on solvent & conditions. Fast injection:.
Agilent 18740-80220 Agilent Splitless Liner for Capillary Inlet Systems 2mm ID. Volume: 250uL. For small (>0.5ul) volumes, depending on solvent and conditions. Quartz (Purity 8) glass.
Agilent 18789-60060 Agilent HP 5880 Detector Supplies Nitrogen Phosphorous Detector (NPD). Performance evaluation sample, NPD.
Agilent 18789-80070 Agilent HP 5890 Detector Supplies Jets. Packed wide-bore 0.030 in. id jet (for high-bleed applications).
Agilent 18801-60700 Agilent Perfomance evaluation sample for FID Solution of 0.02-0.26% (v/v) of n-propanol, isobutanol, toluene, xylenes, nonane, heptanol, decane, undecane, dodecane, and m-cresol in acetone. Two 1.0ml ampoules.
Agilent 18900-20250 Agilent GC Valves and Loops Compatible with HP 5890/6890 Tube, 1/16 in. stainless steel, 280 mm long.
Agilent 18900-20280 Agilent GC Valves and Loops Compatible with HP 5890/6890 Tube, 1/16 in. stainless steel, 400 mm long.
Agilent 18900-20281 Agilent GC Valves and Loops Compatible with HP 5890/6890 Tube, 1/16 in. stainless steel, 575 mm long.
Agilent 18900-20300 Agilent GC Valves and Loops Compatible with HP 5890/6890 Tube, 1/16 in. stainless steel, 560 mm long.
Agilent 18900-20850 Agilent Valve Tool For liner installation, PTFE. A part for interfacing capillary columns to W series valves.
Agilent 18900-60640 Agilent Alcohol in Gasoline Qualitative Petrochemical Standards. Test mixture containing approximately 1% each of ethanol, isopropanol, n-propanol, sec-butanol, isobutyl alcohol, tert-amyl alcohol, and n-butanol; 2% each of methanol and tert-butyl alcohol; and 3% MTBE in gasoline. Three sealed 0.
Agilent 18900-80255 Agilent GC Valves and Loops Compatible with HP 5890/6890 Tube, nickel, 1/16 in. with 1/8 in. bulkhead fitting, 460 mm long.
Agilent 19091-20050 Agilent HP Deactivated Retention Gaps and Column Accessories Uncoated Fused Silica Tubing. Inner Diam: 0.203 mm. Outer Diam: 0.332 mm. Length: 50 m.
Agilent 19091-21050 Agilent HP Deactivated Retention Gaps and Column Accessories Uncoated Fused Silica Tubing. Inner Diam: 0.315 mm. Outer Diam: 0.440 mm. Length: 50 m.
Agilent 19091-60312 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.20mm. Length: 12m. Film Thickness: 0.33um.
Agilent 19091-60620E Agilent Fused Silica, Deactivated Wound on 127mm cage. Use as retention gaps, guard columns or transfer lines. 0.1mm ID. Length: 1000mm. Temperature Range: 0 to 280[degree]C.
Agilent 19091-65020 Agilent Sadtler Retention Index Library Retention Index Kit of Capillary Columns. Kit of the three columns used to generate the RI data in the Sadtler Retention Index Library:. Column, 25 m x 0.32 mm (19091A-112). Column, 25 m x 0.32 mm (19091B-112). Column, 25 m x 0.32 mm (19091W-012).
Agilent 19091-80060 Agilent Cage for 68550 127mm.
Agilent 19091A-002 Agilent HP-Ultra 1 GC Column For analysis of hydrocarbons, amines, and drugs requiring precise column-to-column reproducibility. Use with the Sadtler Retention Index. Phase composition: bonded dimethyl-polysiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.2mm. Length: 25m. Film Thickness: 0.11um.
Agilent 19091A-005 Agilent HP-Ultra 1 GC column Inner Diam.: 0.2 mm. Length: 50 m. Film Thickness: 0.11 um. HP Ultra columns are manufactured to the equivalent stringent specifications of the HP-1 and HP-5 columns, with even tighter tolerances for retention index and capacity factor.
Agilent 19091A-012 Agilent HP-Ultra 1 GC Column For analysis of hydrocarbons, amines, and drugs requiring precise column-to-column reproducibility. Use with the Sadtler Retention Index. Phase composition: bonded dimethyl-polysiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.32mm. Length: 25m. Film Thickness: 0.17um.
Agilent 19091A-015 Agilent HP-Ultra 1 GC column Inner Diam.: 0.32 mm. Length: 50 m. Film Thickness: 0.17 um. HP Ultra columns are manufactured to the equivalent stringent specifications of the HP-1 and HP-5 columns, with even tighter tolerances for retention index and capacity factor.
Agilent 19091A-101 Agilent HP-Ultra 1 GC Column For analysis of hydrocarbons, amines, and drugs requiring precise column-to-column reproducibility. Use with the Sadtler Retention Index. Phase composition: bonded dimethyl-polysiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.2mm. Length: 12m. Film Thickness: 0.33um.
Agilent 19091A-102 Agilent HP-Ultra 1 GC Column For analysis of hydrocarbons, amines, and drugs requiring precise column-to-column reproducibility. Use with the Sadtler Retention Index. Phase composition: bonded dimethyl-polysiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.2mm. Length: 25m. Film Thickness: 0.33um.
Agilent 19091A-102E Agilent GC Column
Agilent 19091A-105 Agilent HP-Ultra 1 GC Column For analysis of hydrocarbons, amines, and drugs requiring precise column-to-column reproducibility. Use with the Sadtler Retention Index. Phase composition: bonded dimethyl-polysiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.2mm. Length: 50m. Film Thickness: 0.33um.
Agilent 19091A-108 Agilent Ultra 1 17m, 0.20mm, 0.33 um
Agilent 19091A-112 Agilent HP-Ultra 1 GC Column For analysis of hydrocarbons, amines, and drugs requiring precise column-to-column reproducibility. Use with the Sadtler Retention Index. Phase composition: bonded dimethyl-polysiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.32mm. Length: 25m. Film Thickness: 0.52um.
Agilent 19091A-115 Agilent HP-Ultra 1 GC Column For analysis of hydrocarbons, amines, and drugs requiring precise column-to-column reproducibility. Use with the Sadtler Retention Index. Phase composition: bonded dimethyl-polysiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.32mm. Length: 50m. Film Thickness: 0.52um.
Agilent 19091B-002 Agilent HP-Ultra 2 GC Column For analyzing FAMEs, alkaloids, and drugs requiring column-to-column reproducibility. Use with the Sadtler Retention Index. Phase composition: bonded 5% diphenyl, 95% dimethyl siloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.2mm. Length: 25m. Film Thickness: 0.11um.
Agilent 19091B-005 Agilent HP-Ultra 2 GC Column For analyzing FAMEs, alkaloids, and drugs requiring column-to-column reproducibility. Use with the Sadtler Retention Index. Phase composition: bonded 5% diphenyl, 95% dimethyl siloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.2mm. Length: 50m. Film Thickness: 0.11um.
Agilent 19091B-012 Agilent HP-Ultra 2 GC Column For analyzing FAMEs, alkaloids, and drugs requiring column-to-column reproducibility. Use with the Sadtler Retention Index. Phase composition: bonded 5% diphenyl, 95% dimethyl siloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.32mm. Length: 25m. Film Thickness: 0.17um.
Agilent 19091B-012E Agilent HP-Ultra 2 DB-5. Wound on 127mm cage. (5%-phenyl)-methylsiloxane. Bonded and cross-linked. Intended for use with Sadtler Retention Index Library. 0.32mm ID. Length: 2500mm. Film: 0.17um. Temperature Range: -60 to 325[degree]C.
Agilent 19091B-015 Agilent HP-Ultra 2 GC column Inner Diam.: 0.32 mm. Length: 50 m. Film Thickness: 0.17 um. HP Ultra columns are manufactured to the equivalent stringent specifications of the HP-1 and HP-5 columns, with even tighter tolerances for retention index and capacity factor.
Agilent 19091B-101 Agilent HP-Ultra 2 GC Column For analyzing FAMEs, alkaloids, and drugs requiring column-to-column reproducibility. Use with the Sadtler Retention Index. Phase composition: bonded 5% diphenyl, 95% dimethyl siloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.2mm. Length: 12m. Film Thickness: 0.33um.
Agilent 19091B-102 Agilent HP-Ultra 2 GC Column For analyzing FAMEs, alkaloids, and drugs requiring column-to-column reproducibility. Use with the Sadtler Retention Index. Phase composition: bonded 5% diphenyl, 95% dimethyl siloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.2mm. Length: 25m. Film Thickness: 0.33um.
Agilent 19091B-102E Agilent HP-Ultra 2 DB-5. Wound on 127mm cage. (5%-phenyl)-methylsiloxane. Bonded and cross-linked. Intended for use with Sadtler Retention Index Library. 0.2mm ID. Length: 2500mm. Film: 0.33um. Temperature Range: -60 to 325[degree]C.
Agilent 19091B-105 Agilent HP-Ultra 2 GC Column For analyzing FAMEs, alkaloids, and drugs requiring column-to-column reproducibility. Use with the Sadtler Retention Index. Phase composition: bonded 5% diphenyl, 95% dimethyl siloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.2mm. Length: 50m. Film Thickness: 0.33um.
Agilent 19091B-105E Agilent GC Column, DB-1301 60m, 0.32mm, 1.00um, 5in cage
Agilent 19091B-112 Agilent HP-Ultra 2 GC Column For analyzing FAMEs, alkaloids, and drugs requiring column-to-column reproducibility. Use with the Sadtler Retention Index. Phase composition: bonded 5% diphenyl, 95% dimethyl siloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.32mm. Length: 25m. Film Thickness: 0.52um.
Agilent 19091B-115 Agilent HP-Ultra 2 GC column Inner Diam.: 0.32 mm. Length: 50 m. Film Thickness: 0.52 um. HP Ultra columns are manufactured to the equivalent stringent specifications of the HP-1 and HP-5 columns, with even tighter tolerances for retention index and capacity factor.
Agilent 19091B-115E Agilent GC Column, DB-1701 60m, .53mm, 1.0um, 5in cage
Agilent 19091F-102 Agilent HP-FFAP PEG Capillary GC Column Acid modified PEG column for analysis of acids, acrylates, alcohols, aldehydes, ketones, nitriles, free-fatty acids. Phase composition: bonded polyethylene glycol-TPA. Temperature Range: 60 to 240[degree]C. I.D.: 0.2mm. Length: 25m. Film Thickness: 0.3um.
Agilent 19091F-102E Agilent GC Column, DB-WAX 20m, 0.18mm, 0.30um, 5in cage
Agilent 19091F-105 Agilent HP-FFAP PEG Capillary GC Column Acid modified PEG column for analysis of acids, acrylates, alcohols, aldehydes, ketones, nitriles, free-fatty acids. Phase composition: bonded polyethylene glycol-TPA. Temperature Range: 60 to 240[degree]C. I.D.: 0.2mm. Length: 50m. Film Thickness: 0.3um.
Agilent 19091F-105E Agilent HP-FFAP Stabilwax-DA. Wound on 127mm cage. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.2mm ID. Length: 5000mm. Film: 0.25um. Temperature Range: 60 to 240[degree]C.
Agilent 19091F-112 Agilent HP-FFAP PEG Capillary GC Column Acid modified PEG column for analysis of acids, acrylates, alcohols, aldehydes, ketones, nitriles, free-fatty acids. Phase composition: bonded polyethylene glycol-TPA. Temperature Range: 60 to 240[degree]C. I.D.: 0.32mm. Length: 25m. Film Thickness: 0.5um.
Agilent 19091F-112E Agilent HP-FFAP Stabilwax-DA. Wound on 127mm cage. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 2500mm. Film: 0.5um. Temperature Range: 60 to 240[degree]C.
Agilent 19091F-115 Agilent HP-FFAP PEG Capillary GC Column Acid modified PEG column for analysis of acids, acrylates, alcohols, aldehydes, ketones, nitriles, free-fatty acids. Phase composition: bonded polyethylene glycol-TPA. Temperature Range: 60 to 240[degree]C. I.D.: 0.32mm. Length: 50m. Film Thickness: 0.5um.
Agilent 19091F-115E Agilent HP-FFAP Stabilwax-DA. Wound on 127mm cage. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 5000mm. Film: 0.5um. Temperature Range: 60 to 240[degree]C.
Agilent 19091F-413 Agilent HP-FFAP GC column Inner Diam.: 0.32 mm. Length: 30 m. Film Thickness: 0.25 um. The order of polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases.
Agilent 19091F-433 Agilent HP-FFAP GC column Inner Diam.: 0.25 mm. Length: 30 m. Film Thickness: 0.25 um. The order of polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases.
Agilent 19091F-433E Agilent HP-FFAP Stabilwax-DA. Wound on 127mm cage. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.25mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: 60 to 240[degree]C.
Agilent 19091G-113 Agilent HP35 Capillary GC Column Intermediate polarity column for analysis of amines, PCBs, pesticides, pharmaceuticals. Use for EPA Method 8081 and USP G-42. Phase composition: 35% diphenyl, 65% methyl siloxane. Temperature Range: -40 to 300/320[degree]C. I.D. 0.32mm. Length 30m. Thickness 0.25um.
Agilent 19091G-131 Agilent HP35 Capillary GC Column Intermediate polarity column for analysis of amines, PCBs, pesticides, pharmaceuticals. Use for EPA Method 8081 and USP G-42. Phase composition: 35% diphenyl, 65% methyl siloxane. Temperature Range: -40 to 300/320[degree]C. I.D. 0.25mm. Length 15m. Thickness 0.25um.
Agilent 19091G-131E Agilent GC Column, HP-35 15m, 0.25mm, 0.25um, 5in cage
Agilent 19091G-133 Agilent HP35 Capillary GC Column Intermediate polarity column for analysis of amines, PCBs, pesticides, pharmaceuticals. Use for EPA Method 8081 and USP G-42. Phase composition: 35% diphenyl, 65% methyl siloxane. Temperature Range: -40 to 300/320[degree]C. I.D. 0.25mm. Length 30m. Thickness 0.25um.
Agilent 19091G-213 Agilent HP-35 GC column Inner Diam.: 0.32 mm. Length: 30 m. Film thickness: 0.50 um. Similar Phases:. DB-35, Rtx-35, SPB-35, SPB-608, AT-35, Sup-Herb. Temperature Range isothermal/temperature programmed. 40 to 300/320[degree]C. 40 to 280/300[degree]C for 0.53 mm i.d.
Agilent 19091G-B133 Agilent HP-Chiral-10B GC column Inner Diam.: 0.25 mm. Length: 30 m. Film Thickness: 0.25 um. Cyclodextrin: 10 %. Similar Phases. CP Chirasil Dex CB, CP-Cyclodextrin-2,3,6,M19, Rt-DEXm, DEX110/120. Temperature Range isothermal/temperature programmed. 30 to 240/250[degree]C.
Agilent 19091G-B213 Agilent HP-Chiral-20B GC column Inner Diam.: 0.32 mm. Length: 30 m. Film Thickness: 0.25 um. Cyclodextrin: 20 %. Similar Phases. CP Chirasil Dex CB, CP-Cyclodextrin-2,3,6,M19, Rt-DEXm, DEX110/120. Temperature Range isothermal/temperature programmed. 30 to 240/250[degree]C.
Agilent 19091G-B213E Agilent GC Column, DB-210 30m, 0.53mm, 1.00um, 5in cage
Agilent 19091G-B233 Agilent HP-Chiral-20B GC column Inner Diam.: 0.25 mm. Length: 30 m. Film Thickness: 0.25 um. Cyclodextrin: 20 %. Similar Phases. CP Chirasil Dex CB, CP-Cyclodextrin-2,3,6,M19, Rt-DEXm, DEX110/120. Temperature Range isothermal/temperature programmed. 30 to 240/250[degree]C.
Agilent 19091G-B233E Agilent GC Column, DB-5MS 30m, 0.25mm, 0.50um, 5in cage
Agilent 19091J-002 Agilent HP-5 GC column Inner Diam.: 0.2 mm. Length: 25 m. Film thickness: 0.11 um. Similar Phases:. DB-5, Rtx-5, SPB-5, PTE-5, CP-Sil 8CB, SE-54, DB-5ht, DB-5.625, Mtx-5, OV-5, SE-52, GC-5, 007-2, RSL-200, MDN-5, BP-5. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C.
Agilent 19091J-005 Agilent HP-5 GC column Inner Diam.: 0.2 mm. Length: 50 m. Film thickness: 0.11 um. Similar Phases:. DB-5, Rtx-5, SPB-5, PTE-5, CP-Sil 8CB, SE-54, DB-5ht, DB-5.625, Mtx-5, OV-5, SE-52, GC-5, 007-2, RSL-200, MDN-5, BP-5. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C.
Agilent 19091J-012 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.32mm. Length 25m. Thickness: 0.17um.
Agilent 19091J-012E Agilent GC Column, DB-35MS 25m, 0.20mm, 0.33um, 5in cage
Agilent 19091J-015 Agilent HP-5 GC column Inner Diam.: 0.2 mm. Length: 50 m. Film thickness: 0.17 um. Similar Phases:. DB-5, Rtx-5, SPB-5, PTE-5, CP-Sil 8CB, SE-54, DB-5ht, DB-5.625, Mtx-5, OV-5, SE-52, GC-5, 007-2, RSL-200, MDN-5, BP-5. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C.
Agilent 19091J-101 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.2mm. Length 12m. Thickness: 0.33um.
Agilent 19091J-102 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.2mm. Length 25m. Thickness: 0.33um.
Agilent 19091J-102E Agilent GC Column
Agilent 19091J-105 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.2mm. Length 50m. Thickness: 0.33um.
Agilent 19091J-105E Agilent GC Column, DB-225 30m, 0.53mm, 1.00um, 5in cage
Agilent 19091J-108 Agilent HP-5 17m, 0.20mm, 0.33 um
Agilent 19091J-112 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.32mm. Length 25m. Thickness: 0.52um.
Agilent 19091J-112E Agilent HP5 Capillary GC Column On 127mm cage. Nonpolar. For analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.32mm. Length 25m. Film: 0.52um.
Agilent 19091J-113 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.32mm. Length 30m. Thickness: 0.5um.
Agilent 19091J-113E Agilent GC Column, HP-5MS, 25m, 0.32mm, 0.52um, 5in cage
Agilent 19091J-115 Agilent HP-5 GC column Inner Diam.: 0.2 mm. Length: 50 m. Film thickness: 0.52 um. Similar Phases:. DB-5, Rtx-5, SPB-5, PTE-5, CP-Sil 8CB, SE-54, DB-5ht, DB-5.625, Mtx-5, OV-5, SE-52, GC-5, 007-2, RSL-200, MDN-5, BP-5. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C.
Agilent 19091J-202 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.2mm. Length 25m. Thickness: 0.5um.
Agilent 19091J-205 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.2mm. Length 50m. Thickness: 0.5um.
Agilent 19091J-212 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.32mm. Length 25m. Thickness: 1.05um.
Agilent 19091J-213 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.32mm. Length 30m. Thickness: 1um.
Agilent 19091J-213E Agilent HP5 Capillary GC Column Wound on 127mm cage. Nonpolar. For analysis of semivolatives, alkaloids, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.32mm. Length 30m. Film: 1um.
Agilent 19091J-215 Agilent HP-5 GC column Inner Diam.: 0.2 mm. Length: 50 m. Film thickness: 1.05 um. Similar Phases:. DB-5, Rtx-5, SPB-5, PTE-5, CP-Sil 8CB, SE-54, DB-5ht, DB-5.625, Mtx-5, OV-5, SE-52, GC-5, 007-2, RSL-200, MDN-5, BP-5. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C.
Agilent 19091J-215E Agilent GC Column, DB-1 40m, 0.18mm, 0.40um, 5in cage
Agilent 19091J-216 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.32mm. Length 60m. Thickness: 1um.
Agilent 19091J-216E Agilent GC Column, DB-23 60m, 0.25mm, 0.25um, 5in cage
Agilent 19091J-231 Agilent HP-5 GC column Inner Diam.: 0.25 mm. Length: 15 m. Film thickness: 1.0 um. Similar Phases:. DB-5, Rtx-5, SPB-5, PTE-5, CP-Sil 8CB, SE-54, DB-5ht, DB-5.625, Mtx-5, OV-5, SE-52, GC-5, 007-2, RSL-200, MDN-5, BP-5. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C.
Agilent 19091J-233 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.25mm. Length 30m. Thickness: 1um.
Agilent 19091J-236 Agilent HP5 Capillary GC Column Nonpolar. For analysis of semivolatives, alkaloids, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.25mm. Length 60m. Thickness: 1um.
Agilent 19091J-236E Agilent HP5 Capillary GC Column Wound on 127mm cage. Nonpolar. For analysis of semivolatives, alkaloids, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.25mm. Length 60m. Thickness: 1um.
Agilent 19091J-313 Agilent HP-5 GC column Inner Diam.: 0.32 mm. Length: 30 m. Film thickness: 0.1 um. Similar Phases:. DB-5, Rtx-5, SPB-5, PTE-5, CP-Sil 8CB, SE-54, DB-5ht, DB-5.625, Mtx-5, OV-5, SE-52, GC-5, 007-2, RSL-200, MDN-5, BP-5. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C.
Agilent 19091J-333 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.25mm. Length 30m. Thickness: 0.1um.
Agilent 19091J-411 Agilent HP5 Capillary GC Column Nonpolar. For analysis of semivolatives, alkaloids, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.32mm. Length 15m. Thickness: 0.25um.
Agilent 19091J-413 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.32mm. Length 30m. Thickness: 0.25um.
Agilent 19091J-413E Agilent HP5 Capillary GC Column Wound on 127mm cage. Nonpolar. For analysis of semivolatives, alkaloids, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.32mm. Length 30m. Film: 0.25um.
Agilent 19091J-416 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.32mm. Length 60m. Thickness: 0.25um.
Agilent 19091J-431 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.25mm. Length 15m. Thickness: 0.25um.
Agilent 19091J-431E Agilent GC Column, HP-5 15m, 0.25mm, 0.25um, 5in cage
Agilent 19091J-433 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.25mm. Length 30m. Thickness: 0.25um.
Agilent 19091J-433E Agilent HP5 Capillary GC Column Wound on 127mm cage. Nonpolar. For analysis of semivolatives, alkaloids, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.25mm. Length 30m. Film: 0.25um.
Agilent 19091J-436 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. I.D. 0.25mm. Length 60m. Thickness: 0.25um.
Agilent 19091J-436E Agilent GC Column
Agilent 19091J-577 Agilent Hp-5, 20M, 0.18Mm, 0.18Um
Agilent 19091L-101 Agilent HP-50+ GC column Inner Diam.: 0.20 mm. Length: 12 m. Film thickness: 0.31 um. Similar Phases:. DB-17, Rtx-50, SP-2250, DB-17ht, SPB-50, 007-17, CP-Sil 19, CP-Sil 24CBRSL-300, AT-50, OV-17, BPX-50. Temperature Range isothermal/temperature programmed. 40 to 280/300[degree]C.
Agilent 19091L-113 Agilent HP50 Capillary GC Column Midpolarity. For confirmational analyses. Composition: bonded (50% phenyl)-methylpolysiloxane. Range: 40 to 280/300[degree]C. I.D.: 0.32mm. Length: 30m. Film: 0.5um.
Agilent 19091L-133 Agilent HP-50+ GC column Inner Diam.: 0.25 mm. Length: 30 m. Film thickness: 0.5 um. Similar Phases:. DB-17, Rtx-50, SP-2250, DB-17ht, SPB-50, 007-17, CP-Sil 19, CP-Sil 24CBRSL-300, AT-50, OV-17, BPX-50. Temperature Range isothermal/temperature programmed. 40 to 280/300[degree]C.
Agilent 19091L-333 Agilent HP-50+ GC column Inner Diam.: 0.25 mm. Length: 30 m. Film thickness: 0.15 um. Similar Phases:. DB-17, Rtx-50, SP-2250, DB-17ht, SPB-50, 007-17, CP-Sil 19, CP-Sil 24CBRSL-300, AT-50, OV-17, BPX-50. Temperature Range isothermal/temperature programmed. 40 to 280/300[degree]C.
Agilent 19091L-413 Agilent HP-50+ GC column Inner Diam.: 0.32 mm. Length: 30 m. Film thickness: 0.25 um. Similar Phases:. DB-17, Rtx-50, SP-2250, DB-17ht, SPB-50, 007-17, CP-Sil 19, CP-Sil 24CBRSL-300, AT-50, OV-17, BPX-50. Temperature Range isothermal/temperature programmed. 40 to 280/300[degree]C.
Agilent 19091L-413E Agilent GC Column
Agilent 19091L-416 Agilent HP-50+ GC column Inner Diam.: 0.32 mm. Length: 60 m. Film thickness: 0.25 um. Similar Phases:. DB-17, Rtx-50, SP-2250, DB-17ht, SPB-50, 007-17, CP-Sil 19, CP-Sil 24CBRSL-300, AT-50, OV-17, BPX-50. Temperature Range isothermal/temperature programmed. 40 to 280/300[degree]C.
Agilent 19091L-431 Agilent HP-50+ GC column Inner Diam.: 0.25 mm. Length: 15 m. Film thickness: 0.25 um. Similar Phases:. DB-17, Rtx-50, SP-2250, DB-17ht, SPB-50, 007-17, CP-Sil 19, CP-Sil 24CBRSL-300, AT-50, OV-17, BPX-50. Temperature Range isothermal/temperature programmed. 40 to 280/300[degree]C.
Agilent 19091L-433 Agilent HP-50+ GC column Inner Diam.: 0.25 mm. Length: 30 m. Film thickness: 0.25 um. Similar Phases:. DB-17, Rtx-50, SP-2250, DB-17ht, SPB-50, 007-17, CP-Sil 19, CP-Sil 24CBRSL-300, AT-50, OV-17, BPX-50. Temperature Range isothermal/temperature programmed. 40 to 280/300[degree]C.
Agilent 19091L-577 Agilent Hp-50+, 20M, 0.18Mm, 0.18Um
Agilent 19091N-013 Agilent HP-INNOWax GC Column HP-20M; SUPELCOWAX 10. Polyethylene glycol. High polarity. Column to column repeatability. Bonded and cross-linked. Solvent rinsable. 0.32mm ID. Length: 3000mm. Film: 0.15um. Temperature Range: 40 to 260/270[degree]C.
Agilent 19091N-033 Agilent HP-INNOWax GC column Inner Diam.: 0.25 mm. Length: 30 m. Film Thickness 0.15 um. The order of polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases.
Agilent 19091N-036 Agilent HP-INNOWax GC column Inner Diam.: 0.25 mm. Length: 60 m. Film Thickness 0.15 um. The order of polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases.
Agilent 19091N-102 Agilent HP-INNOWax GC column Inner Diam.: 0.2 mm. Length: 25 m. Film Thickness 0.2 um. The order of polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases.
Agilent 19091N-105 Agilent HP-INNOWax GC column Inner Diam.: 0.2 mm. Length: 50 m. Film Thickness: 0.2 um. The order of polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases.
Agilent 19091N-105E Agilent GC Column, HP-5 50m, 0.20mm, 0.33um, 5in cage
Agilent 19091N-111 Agilent HP-INNOWax GC column Inner Diam.: 0.32 mm. Length: 15 m. Film Thickness 0.25 um. The order of polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases.
Agilent 19091N-113 Agilent HP-INNOWax PEG Capillary GC Column PEG column for the analysis of alcohols, aromatics, essential oils, and free acids. Phase composition: INNOphase* bonded polyethylene glycol. Temperature Range: 40 to 260[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness: 0.25um.
Agilent 19091N-113E Agilent HP-INNOWax PEG Capillary GC Column Wound on 127mm cage. PEG column for the analysis of alcohols, aromatics, essential oils, and free acids. Phase composition: INNOphase* bonded polyethylene glycol. Temperature Range: 40 to 260[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness: 0.25um.
Agilent 19091N-116 Agilent HP-INNOWax GC column Inner Diam.: 0.32 mm. Length: 60 m. Film Thickness 0.25 um. The order of polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases.
Agilent 19091N-131 Agilent HP-INNOWax PEG Capillary GC Column PEG column for the analysis of alcohols, aromatics, essential oils, and free acids. Phase composition: INNOphase* bonded polyethylene glycol. Temperature Range: 40 to 260[degree]C. I.D.: 0.25mm. Length: 15m. Film Thickness: 0.25um.
Agilent 19091N-131E Agilent GC Column, HP-INNOWax 15m, 0.25mm, 0.25um, 5in cage
Agilent 19091N-133 Agilent HP-INNOWax PEG Capillary GC Column PEG column for the analysis of alcohols, aromatics, essential oils, and free acids. Phase composition: INNOphase* bonded polyethylene glycol. Temperature Range: 40 to 260[degree]C. I.D.: 0.25mm. Length: 30m. Film Thickness: 0.25um.
Agilent 19091N-133E Agilent HP-INNOWax PEG Capillary GC Column Wound on 127mm cage. PEG column for the analysis of alcohols, aromatics, essential oils, and free acids. Phase composition: INNOphase* bonded polyethylene glycol. Temperature Range: 40 to 260[degree]C. I.D.: 0.25mm. Length: 30m. Film Thickness: 0.25um.
Agilent 19091N-136 Agilent HP-INNOWax PEG Capillary GC Column PEG column for the analysis of alcohols, aromatics, essential oils, and free acids. Phase composition: INNOphase* bonded polyethylene glycol. Temperature Range: 40 to 260[degree]C. I.D.: 0.25mm. Length: 60m. Film Thickness: 0.25um.
Agilent 19091N-136E Agilent GC Column
Agilent 19091N-202 Agilent HP-INNOWax PEG Capillary GC Column PEG column for the analysis of alcohols, aromatics, essential oils, and free acids. Phase composition: INNOphase* bonded polyethylene glycol. Temperature Range: 40 to 260[degree]C. I.D.: 0.2mm. Length: 25m. Film Thickness: 0.4um.
Agilent 19091N-205 Agilent HP-INNOWax GC column Inner Diam.: 0.2 mm. Length: 50 m. Film Thickness: 0.4 um. The order of polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases.
Agilent 19091N-205E Agilent GC Column, HP-1, 50m, 0.20mm, 0.33um, 5in cage
Agilent 19091N-213 Agilent HP-INNOWax PEG Capillary GC Column PEG column for the analysis of alcohols, aromatics, essential oils, and free acids. Phase composition: INNOphase* bonded polyethylene glycol. Temperature Range: 40 to 260[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness: 0.5um.
Agilent 19091N-216 Agilent HP-INNOWax PEG Capillary GC Column PEG column for the analysis of alcohols, aromatics, essential oils, and free acids. Phase composition: INNOphase* bonded polyethylene glycol. Temperature Range: 40 to 260[degree]C. I.D.: 0.32mm. Length: 60m. Film Thickness: 0.5um.
Agilent 19091N-216E Agilent HP-INNOWax PEG Capillary GC Column Wound on 127mm cage. PEG column for the analysis of alcohols, aromatics, essential oils, and free acids. Phase composition: INNOphase* bonded polyethylene glycol. Temperature Range: 40 to 260[degree]C. I.D.: 0.32mm. Length: 60m. Film Thickness: 0.5um.
Agilent 19091N-231 Agilent HP-INNOWax GC column Inner Diam.: 0.25 mm. Length: 15 m. Film Thickness: 0.5 um. The order of polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases.
Agilent 19091N-233 Agilent HP-INNOWax PEG Capillary GC Column PEG column for the analysis of alcohols, aromatics, essential oils, and free acids. Phase composition: INNOphase* bonded polyethylene glycol. Temperature Range: 40 to 260[degree]C. I.D.: 0.25mm. Length: 30m. Film Thickness: 0.5um.
Agilent 19091N-236 Agilent HP-INNOWax GC column Inner Diam.: 0.25 mm. Length: 60 m. Film Thickness 0.5 um. The order of polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases.
Agilent 19091N-577 Agilent Hp-Innowax, 20M, 0.18Mm, 0.18Um
Agilent 19091P-K15 Agilent HP-PLOT Al2O3 "KCI" Deactivation GC column Inner Diam.: 0.32 mm. Length: 50 m. Film Thickness: 8 um. The order of polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases:.
Agilent 19091P-K33 Agilent HP-PLOT Al2O3 "KCL" Deactivation GC Column Inner Diam.: 0.25 mm. Length: 30 m. Film Thickness: 5 um. The order of polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases:.
Agilent 19091P-K33E Agilent GC Column, DB-200 30m, 0.53mm, 1.00um, 5in cage
Agilent 19091P-M15 Agilent HP-PLOT Al2O3 "M" Deactivation GC column Inner Diam.: 0.32 mm. Length: 50 m. Film Thickness: 8 um. The order of polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases:.
Agilent 19091P-M15E Agilent GC Column, DB-624 60m, 0.53mm, 3.00um, 5in cage
Agilent 19091P-MS4 Agilent HP-PLOT Molesieve GC column Thin Film:. Inner Diam.: 0.32 mm. Length: 30 m. Film Thickness: 12 um. Similar Phases. W GS-Molesieve, CP Molesieve 5A, RT-Msieve 13X, Molsieve 5A-PLOT. Maximum Temperature:. 350[degree]C.
Agilent 19091P-MS7 Agilent HP-PLOT Molesieve GC column Thick Film:. Inner Diam.: 0.32 mm. Length: 15 m. Film Thickness: 25 um. Similar Phases. W GS-Molesieve, CP Molesieve 5A, RT-Msieve 13X, Molsieve 5A-PLOT. Maximum Temperature:. 350[degree]C.
Agilent 19091P-MS8 Agilent HP-PLOT Molecular Sieve 5A Capillary GC Column Thick-film PLOT column for air monitoring applications and analyzing noble gases. Resolve argon and oxygen at ambient temperatures. Phase composition: 5A zeolite. Temperature Range: up to 350[degree]C. ID: 0.32mm. Length: 30m. Film Thickness: 25um.
Agilent 19091P-QO3 Agilent HP-PLOT Q CP PoraPlot Q. Bonded polystyrene-divinylbenzene based column. Separates ethane, ethlene, and ethyne (acetylene). 0.32mm ID. Length: 1500mm. Film: 20um. Temperature Range: -60 to 270/290[degree]C.
Agilent 19091P-QO4 Agilent HP-PLOT Q CP PoraPlot Q. Bonded polystyrene-divinylbenzene based column. Separates ethane, ethlene, and ethyne (acetylene). 0.32mm ID. Length: 3000mm. Film: 20um. Temperature Range: -60 to 270/290[degree]C.
Agilent 19091P-QO4E Agilent HP-PLOT Q CP PoraPlot Q. Wound on 127mm cage. Bonded polystyrene-divinylbenzene based column. Separates ethane, ethlene, and ethyne (acetylene). 0.32mm ID. Length: 3000mm. Film: 20um. Temperature Range: -60 to 270/290[degree]C.
Agilent 19091P-S15 Agilent HP-PLOT Capillary GC Column Al2O3. "S" column. For analysis of light hydrocarbons (C1 to C6) resolving cyclopropane from propylene. Phase composition: Aluminum oxide. Temperature range: up to 200[degree]C. ID: 0.32mm. Length: 50m. Film thickness: 8um.
Agilent 19091P-S15E Agilent HP-PLOT AI203 S 50m,0.32mm,8.0um,5in cage
Agilent 19091P-S33 Agilent HP-PLOT Al2O3 "S" Deactivation GC column Inner Diam.: 0.25 mm. Length: 30 m. Film Thickness: 5 um. The order of polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases:.
Agilent 19091P-UO4 Agilent HP-PLOT U CP PoraPlot U. Bonded divinylbenzene/ethylene glycol dimethacrylate. Column for C1 to C7 hydrocarbons, CO2, methane, air/CO, water, solvents, amines, alcohols, and more. 0.32mm ID. Length: 3000mm. Film: 10um. Temperature Range: -60 to 190[degree]C.
Agilent 19091R-303 Agilent HP-VOC Environmental Capillary GC Column Intermediate polarity column for the analysis of volatile organics. Recommended for EPA Methods 502.2, 524.2, 601, 602, 8024, and 8260. Temperature Range: -60 to 280[degree]C. ID: 0.20mm. Length: 30m. Film Thickness: 1.1um.
Agilent 19091R-306 Agilent HP-VOC Environmental Capillary GC Column Intermediate polarity column for the analysis of volatile organics. Recommended for EPA Methods 502.2, 524.2, 601, 602, 8024, and 8260. Temperature Range: -60 to 280[degree]C. ID: 0.20mm. Length: 60m. Film Thickness: 1.1um.
Agilent 19091R-316 Agilent HP-VOC Environmental Capillary GC Column Intermediate polarity column for the analysis of volatile organics. Recommended for EPA Methods 502.2, 524.2, 601, 602, 8024, and 8260. Temperature Range: -60 to 280[degree]C. ID: 0.32mm. Length: 60m. Film Thickness: 1.8um.
Agilent 19091R-319 Agilent HP-VOC Environmental Capillary GC Column Intermediate polarity column for the analysis of volatile organics. Recommended for EPA Methods 502.2, 524.2, 601, 602, 8024, and 8260. Temperature Range: -60 to 280[degree]C. ID: 0.32mm. Length: 90m. Film Thickness: 1.8um.
Agilent 19091S-001 Agilent HP-PONA Petroleum Analyses Capillary GC Column For the separation of paraffins, olefins, naphthenes, aromatics. Tested to ensure resolution of m-xylene from p-xylene, and cyclopentane from 2,3-dimethylbutane. Temperature Range: 60 to -325[degree]C. ID: 0.20mm. Length: 50m. Film Thickness: 0.5um.
Agilent 19091S-001E Agilent HP-PONA Petroleum Analyses Capillary GC Column On 127mm cage. For separation of paraffins, olefins, naphthenes, aromatics. Tested to ensure resolution of m-xylene from p-xylene, and cyclopentane from 2,3-dimethylbutane. Temperature Range: 60 to -325[degree]C. ID: 0.20mm. Length: 50m. Film: 0.5um.
Agilent 19091S-004 Agilent HP-1/DHA (5%)-diphenyl-(95%)-dimethylsiloxane, polydimethylsiloxane. 0.25mm ID. Length: 10,000mm. Film: 0.5um. Temperature Range: -60 to 325[degree]C.
Agilent 19091S-004E Agilent GC Column, ULTRA-2 50m, 0.32mm, 0.52um, 5in cage
Agilent 19091S-010 Agilent HP-PAS-5 GC column Inner Diam.: 0.32 mm. Length: 25 m. Film Thickness: 0.52 um um. HP-PAS-5 Temperature Range. -60 to 325[degree]C. The 25 meter HP-PAS-5 and HP-PAS-1701 columns were developed and are quality-controlled for dual-column confirmation of organochlorine pesticides.
Agilent 19091S-101 Agilent HP-5MS GC column Inner Diam.: 0.20 mm. Length: 12 m. Film thickness: 0.33 um. Similar Phases:. Rtx-5MS, PTE-5. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C.
Agilent 19091S-102 Agilent HP-5MS GC Column Rtx-5MS, PTE-5. (5%-phenyl)-methylpolysiloxane. Non-polar. Very low bleed characteristics. Excellent inertness for active compounds. Bonded and cross-linked. Sovent rinsable. 0.20mm. Length: 2500mm. Film: 0.33um. Temperature Range: -60 to 325/350[degree]C.
Agilent 19091S-102E Agilent HP-5MS GC Column Rtx-5MS, PTE-5. Wound on 127mm cage. (5%-phenyl)-methylpolysiloxane. Non-polar. Very low bleed characteristics. Excellent inertness for active compounds. Bonded and cross-linked. Sovent rinsable. 0.20mm. Length: 2500mm. Film: 0.33um. Temperature Range: -60 to 325/350[degree]C.
Agilent 19091S-105 Agilent HP-5MS GC column Inner Diam.: 0.20 mm. Length: 50 m. Film thickness: 0.33 um. Similar Phases:. Rtx-5MS, PTE-5. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C.
Agilent 19091S-112 Agilent HP-5MS GC column Inner Diam.: 0.25 mm. Length: 25 m. Film thickness: 0.52 um. Similar Phases:. Rtx-5MS, PTE-5. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C.
Agilent 19091S-112E Agilent GC Column, DB-1701 20m, 0.10mm, 0.40um, 5in cage
Agilent 19091S-113 Agilent HP-5MS GC column Inner Diam.: 0.25 mm. Length: 30 m. Film thickness: 0.50 um. Similar Phases:. Rtx-5MS, PTE-5. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C.
Agilent 19091S-133 Agilent HP-5MS GC column Inner Diam.: 0.25 mm. Length: 30m. Film thickness: 0.5um. Similar Phases:. Rtx-5MS, PTE-5. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C.
Agilent 19091S-139 Agilent HP-5MS, Semivolatile Test. 0.25mm. Length: 3000mm. Film: 0.5um. Temperature Range: -60 to 325/350[degree]C.
Agilent 19091S-213 Agilent Environmental Standards HP-5MS, 30-m x 0.32 mm x 1.0 um column. Volatile Organic Compounds. Method 524.2.
Agilent 19091S-231 Agilent HP-5MS GC column Inner Diam.: 0.25 mm. Length: 15 m. Film thickness: 1.00 um. Similar Phases:. Rtx-5MS, PTE-5. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C.
Agilent 19091S-233 Agilent HP-5MS GC Column Rtx-5MS, PTE-5. (5%-phenyl)-methylpolysiloxane. Non-polar. Very low bleed characteristics. Excellent inertness for active compounds. Bonded and cross-linked. Sovent rinsable. 0.25mm. Length: 3000mm. Film: 1um. Temperature Range: -60 to 325/350[degree]C.
Agilent 19091S-233E Agilent HP-5MS GC Column Rtx-5MS, PTE-5. Wound on 127mm cage. (5%-phenyl)-methylpolysiloxane. Non-polar. Very low bleed characteristics. Excellent inertness for active compounds. Bonded and cross-linked. Sovent rinsable. 0.25mm. Length: 3000mm. Film: 1um. Temperature Range: -60 to 325/350[degree]C.
Agilent 19091S-313 Agilent HP-5MS GC column Inner Diam.: 0.25 mm. Length: 30 m. Film thickness: 0.10 um. Similar Phases:. Rtx-5MS, PTE-5. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C.
Agilent 19091S-331 Agilent HP-5MS GC column Inner Diam.: 0.25 mm. Length: 15 m. Film thickness: 0.10 um. Similar Phases:. Rtx-5MS, PTE-5. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C.
Agilent 19091S-333 Agilent HP-5MS GC column Inner Diam.: 0.25 mm. Length: 30 m. Film thickness: 0.10 um. Similar Phases:. Rtx-5MS, PTE-5. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C.
Agilent 19091S-336 Agilent HP-5MS GC column Inner Diam.: 0.25 mm. Length: 60 m. Film thickness: 0.10 um. Similar Phases:. Rtx-5MS, PTE-5. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C.
Agilent 19091S-413 Agilent HP-5MS GC column Inner Diam.: 0.25 mm. Length: 30 m. Film thickness: 0.25 um. Similar Phases:. Rtx-5MS, PTE-5. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C.
Agilent 19091S-413E Agilent GC Column, GS-Q 30m, 0.32mm, 5in cage
Agilent 19091S-416 Agilent HP-5MS GC column Inner Diam.: 0.25 mm. Length: 60 m. Film thickness: 0.25 um. Similar Phases:. Rtx-5MS, PTE-5. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C.
Agilent 19091S-431 Agilent HP-5MS GC column Inner Diam.: 0.25 mm. Length: 15 m. Film thickness: 0.25 um. Similar Phases:. Rtx-5MS, PTE-5. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C.
Agilent 19091S-433 Agilent HP-5MS Capillary GC Column For GC/MS analysis of alkaloids, drugs, FAMEs, and halogenated compounds. Use for EPA methods 525, 625, 8250, and 8270. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. ID: 0.25mm. Length: 30m. Thickness: 0.25um.
Agilent 19091S-433E Agilent HP-5MS Capillary GC Column Wound on 127mm cage. For GC/MS analysis of alkaloids, drugs, FAMEs, and halogenated compounds. Use for EPA methods 525, 625, 8250, and 8270. Composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 325/350[degree]C. ID: 0.25mm. Length: 30m. Film: 0.25um.
Agilent 19091S-433I Agilent HP-5msi 30m x 0.25mm ID, 0.25um for acid and base analysis. (5% phenyl) methylpolysiloxane.
Agilent 19091S-436 Agilent HP-5MS GC column Inner Diam.: 0.25 mm. Length: 60 m. Film thickness: 0.25 um. Similar Phases:. Rtx-5MS, PTE-5. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C.
Agilent 19091S-436E Agilent GC Column, DB-WAXETR 60m, 0.32mm, 0.50um, 5in cage
Agilent 19091S-510 Agilent HP-Blood Alcohol Column Reliable blood alcohol analysis. Excellent confirmation column with DB-ALC2 for method using t-butanol as internal standard. ID: 0.32mm. Length: 750m. Thickness: 20um. Temperature Range: -60 to 325/350[degree]C.
Agilent 19091S-510E Agilent HP-Blood Alcohol Column Wound on 127mm cage. Reliable blood alcohol analysis. Excellent confirmation column with DB-ALC2 for method using t-butanol as internal standard. ID: 0.32mm. Length: 750m. Thickness: 20um. Temperature Range: -60 to 325/350[degree]C.
Agilent 19091S-577 Agilent Hp-5Ms, 20M, 0.18Mm, 0.18Um
Agilent 19091S-602 Agilent HP-1MS GC column Inner Diam.: 0.20 mm. Length: 25 m. Film thickness: 0.33 um. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C. This phase is identical to the HP-1 phase with respect to its chromatographic behavior, but has ultra-low bleed specifications.
Agilent 19091S-602E Agilent GC Column, DB-1 25m, 0.25mm, 0.25um, 5in cage
Agilent 19091S-612 Agilent HP-1MS GC column Inner Diam.: 0.32 mm. Length: 25 m. Film thickness: 0.52 um. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C. This phase is identical to the HP-1 phase with respect to its chromatographic behavior, but has ultra-low bleed specifications.
Agilent 19091S-633 Agilent HP-1MS GC column Inner Diam.: 0.25 mm. Length: 30 m. Film thickness: 0.50 um. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C. This phase is identical to the HP-1 phase with respect to its chromatographic behavior, but has ultra-low bleed specifications.
Agilent 19091S-677 Agilent Hp-1Ms, 20M, 0.18Mm, 0.18Um
Agilent 19091S-713 Agilent Environmental Standards HP-1MS, 30-m x 0.32 mm x 1.0 um column. Organohalide Pesticide and PCBs. Method 505.
Agilent 19091S-733 Agilent HP-1MS GC column Inner Diam.: 0.25 mm. Length: 30 m. Film thickness: 1.00 um. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C. This phase is identical to the HP-1 phase with respect to its chromatographic behavior, but has ultra-low bleed specifications.
Agilent 19091S-733E Agilent GC Column, DB-5MS 30m, 0.25mm, 0.25um, 5in cage
Agilent 19091S-833 Agilent HP-1MS GC column Inner Diam.: 0.25 mm. Length: 30 m. Film thickness: 0.10 um. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C. This phase is identical to the HP-1 phase with respect to its chromatographic behavior, but has ultra-low bleed specifications.
Agilent 19091S-911 Agilent HP-1MS GC column Inner Diam.: 0.32 mm. Length: 15 m. Film thickness: 0.25 um. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C. This phase is identical to the HP-1 phase with respect to its chromatographic behavior, but has ultra-low bleed specifications.
Agilent 19091S-913 Agilent Environmental Standards HP-1MS, 30-m x 0.32 mm x 0.25 um column. 1,2-Dibromoethane/Chloropropane (EDB/DBCP). Method 504.
Agilent 19091S-913E Agilent GC Column, GS-ALUMINA 30m, 0.53m, 5in cage
Agilent 19091S-916 Agilent HP-1MS GC column Inner Diam.: 0.32 mm. Length: 60 m. Film thickness: 0.25 um. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C. This phase is identical to the HP-1 phase with respect to its chromatographic behavior, but has ultra-low bleed specifications.
Agilent 19091S-931 Agilent HP-1MS GC column Inner Diam.: 0.25 mm. Length: 15 m. Film thickness: 0.25 um. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C. This phase is identical to the HP-1 phase with respect to its chromatographic behavior, but has ultra-low bleed specifications.
Agilent 19091S-931E Agilent GC Column, DB-WAX 15m, 0.53mm, 1.00um, 5in cage
Agilent 19091S-933 Agilent HP-1MS GC Column Rtx-1ms. 100% Dimethylpolysiloxane. General purpose column with identical selectivity as HP-1. Non-polar. Low bleed characteristics. Bonded and cross-linked. 0.25mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: -60 to 325/350[degree]C.
Agilent 19091S-933E Agilent HP-1MS GC Column Rtx-1ms. Wound on 127mm cage. 100% Dimethylpolysiloxane. General purpose column with identical selectivity as HP-1. Non-polar. Low bleed characteristics. Bonded and cross-linked. 0.25mm ID. Length: 3000mm. Film: 0.25um. Temperature Range: -60 to 325/350[degree]C.
Agilent 19091S-936 Agilent HP-1MS GC column Inner Diam.: 0.25 mm. Length: 60 m. Film thickness: 0.25 um. Temperature Range isothermal/temperature programmed. -60 to 325/350[degree]C. This phase is identical to the HP-1 phase with respect to its chromatographic behavior, but has ultra-low bleed specifications.
Agilent 19091S-936E Agilent HP-1MS GC Column Rtx-1ms. Wound on 127mm cage. 100% Dimethylpolysiloxane. General purpose column with identical selectivity as HP-1. Non-polar. Low bleed characteristics. Bonded and cross-linked. 0.25mm ID. Length: 6000mm. Film: 0.25um. Temperature Range: -60 to 325/350[degree]C.
Agilent 19091W-012 Agilent HP-20M Non-Bonded PEG Capillary GC Column PEG column for the analysis of alcohols, glycols, essential oils, ethers, solvents, and free acids. Phase composition: non-bonded polyethylene glycol. Temperature Range: 60 to 220[degree]C. I.D.: 0.32mm. Length: 25m. Film Thickness: 0.3um.
Agilent 19091W-012E Agilent GC Column, HP-5 25m, 0.32mm, 0.17um, 5in cage
Agilent 19091W-015 Agilent HP-20M Non-Bonded PEG Capillary GC Column PEG column for the analysis of alcohols, glycols, essential oils, ethers, solvents, and free acids. Phase composition: non-bonded polyethylene glycol. Temperature Range: 60 to 220[degree]C. I.D.: 0.32mm. Length: 50m. Film Thickness: 0.3um.
Agilent 19091W-015E Agilent GC Column, HP-5 50m, 0.32mm, 1.05um, 5in cage
Agilent 19091W-102 Agilent HP-20M Non-Bonded PEG Capillary GC Column PEG column for the analysis of alcohols, glycols, essential oils, ethers, solvents, and free acids. Phase composition: non-bonded polyethylene glycol. Temperature Range: 60 to 220[degree]C. I.D.: 0.2mm. Length: 25m. Film Thickness: 0.2um.
Agilent 19091W-105 Agilent HP-Classic Phase Capillary GC column Inner Diam.: 0.20 mm. Length: 50 m. Film Thickness: 0.1 um. Similar Phases. Carbowax 20M, 007CW, BP-20. Temperature Range:. 60 to 220 oC. HP provides high-quality HP-20M nonbonded capillary columns to support established methods. HP-20M: Carbowax 20M Phase.
Agilent 19091Y-012 Agilent HP-Classic Phase Capillary GC column Inner Diam.: 0.32 mm. Length: 25 m. Film Thickness: 0.3 um. Similar Phases. OV 101, SP 200. Temperature Range. 0 to 280[degree]C. HP continues to provide high-quality HP-101 (methyl siloxane fluid) nonbonded capillary columns to support established methods.
Agilent 19091Y-015 Agilent HP-Classic Phase Capillary GC column Inner Diam.: 0.32 mm. Length: 50 m. Film Thickness: 0.3 um. Similar Phases. OV 101, SP 200. Temperature Range. 0 to 280[degree]C. HP continues to provide high-quality HP-101 (methyl siloxane fluid) nonbonded capillary columns to support established methods.
Agilent 19091Y-101 Agilent HP-101 10m, 0.20mm, 0.20um
Agilent 19091Y-102 Agilent HP-Classic Phase Capillary GC column Inner Diam.: 0.20 mm. Length: 25 m. Film Thickness: 0.2 um. Similar Phases. OV 101, SP 200. Temperature Range. 0 to 280[degree]C. HP continues to provide high-quality HP-101 (methyl siloxane fluid) nonbonded capillary columns to support established methods.
Agilent 19091Z-002 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.20mm. Length: 25m. Film Thickness: 0.11um.
Agilent 19091Z-005 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.20mm. Length: 50m. Film Thickness: 0.11um.
Agilent 19091Z-008 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Phase composition: bonded 100% polydimethylsiloxane. I.D.: 0.20mm. Length: 17m. Film thickness: 0.11um. Temperature range: -60 to 325[degrees]C.
Agilent 19091Z-012 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.32mm. Length: 25m. Film Thickness: 0.17um.
Agilent 19091Z-012E Agilent GC Column
Agilent 19091Z-015 Agilent HP-1 GC column Inner Diam.: 0.25 mm. Length: 50 m. Film thickness: 0.17 um. Similar Phases:. DB-1, Rtx-1, OV-1, SPB-1, SE-30, CP-Sil 5CB, RSL-150, MTX-1, BP-1, 007-1, MDN-1. Temperature Range isothermal/temperature programmed:. -60 to 325/350[degree]C. -60 to 300/320[degree]C for 0.53 mm i.d.
Agilent 19091Z-102 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.20mm. Length: 25m. Film Thickness: 0.33um.
Agilent 19091Z-102E Agilent GC Column
Agilent 19091Z-105 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.20mm. Length: 50m. Film Thickness: 0.33um.
Agilent 19091Z-112 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.32mm. Length: 25m. Film Thickness: 0.52um.
Agilent 19091Z-112E Agilent GC Column
Agilent 19091Z-115 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.32mm. Length: 50m. Film Thickness: 0.52um.
Agilent 19091Z-115E Agilent HP-1 Capillary GC Column Wound on 127 cage. Nonpolar. For the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.32mm. Length: 50m. Film Thickness: 0.52um.
Agilent 19091Z-202 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.20mm. Length: 25m. Film Thickness: 0.5um.
Agilent 19091Z-205 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.20mm. Length: 50m. Film Thickness: 0.5um.
Agilent 19091Z-211 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.32mm. Length: 15m. Film Thickness: 1.0um.
Agilent 19091Z-212 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.32mm. Length: 25m. Film Thickness: 1.05um.
Agilent 19091Z-213 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness: 1.0um.
Agilent 19091Z-213E Agilent HP-1 Capillary GC Column Wound on 127 cage. Nonpolar. For the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness: 1um.
Agilent 19091Z-215 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.32mm. Length: 50m. Film Thickness: 1.05um.
Agilent 19091Z-215E Agilent GC Column, DB-VRX 40m, 0.18mm, 1um, 5in cage
Agilent 19091Z-216 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.32mm. Length: 60m. Film Thickness: 1.0um.
Agilent 19091Z-216E Agilent HP-1 Capillary GC Column Wound on 127 cage. Nonpolar. For the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.32mm. Length: 60m. Film Thickness: 1um.
Agilent 19091Z-231 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.25mm. Length: 15m. Film Thickness: 1.0um.
Agilent 19091Z-233 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.25mm. Length: 30m. Film Thickness: 1.0um.
Agilent 19091Z-233E Agilent HP-1 Capillary GC Column Wound on 127 cage. Nonpolar. For the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.25mm. Length: 30m. Film Thickness: 1um.
Agilent 19091Z-236 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.25mm. Length: 60m. Film Thickness: 1.0um.
Agilent 19091Z-236E Agilent HP-1 Capillary GC Column Wound on 127 cage. Nonpolar. For the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.25mm. Length: 60m. Film Thickness: 1um.
Agilent 19091Z-313 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness: 0.1um.
Agilent 19091Z-313E Agilent GC Column, HP-5, 30m, 0.32mm, 0.5um, 5in cage
Agilent 19091Z-331 Agilent HP-1 GC column Inner Diam.: 0.25 mm. Length: 15 m. Film thickness: 0.1 um. Similar Phases:. DB-1, Rtx-1, OV-1, SPB-1, SE-30, CP-Sil 5CB, RSL-150, MTX-1, BP-1, 007-1, MDN-1. Temperature Range isothermal/temperature programmed:. -60 to 325/350[degree]C. -60 to 300/320[degree]C for 0.53 mm i.d.
Agilent 19091Z-333 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.25mm. Length: 30m. Film Thickness: 0.1um.
Agilent 19091Z-411 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.32mm. Length: 15m. Film Thickness: 0.25um.
Agilent 19091Z-411E Agilent GC Column
Agilent 19091Z-413 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness: 0.25um.
Agilent 19091Z-413E Agilent HP-1 Capillary GC Column Wound on 127 cage. Nonpolar. For the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness: 0.25um.
Agilent 19091Z-416 Agilent HP-1 GC column Inner Diam.: 0.25 mm. Length: 60 m. Film thickness: 0.25 um. Similar Phases:. DB-1, Rtx-1, OV-1, SPB-1, SE-30, CP-Sil 5CB, RSL-150, MTX-1, BP-1, 007-1, MDN-1. Temperature Range isothermal/temperature programmed:. -60 to 325/350[degree]C. -60 to 300/320[degree]C for 0.53 mm i.d.
Agilent 19091Z-431 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.25mm. Length: 15m. Film Thickness: 0.25um.
Agilent 19091Z-431E Agilent GC Column, HP-1, 15m, 0.25mm, 0.25um, 5in cage
Agilent 19091Z-433 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.25mm. Length: 30m. Film Thickness: 0.25um.
Agilent 19091Z-433E Agilent HP-1 Capillary GC Column Wound on 127 cage. Nonpolar. For the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.25mm. Length: 30m. Film Thickness: 0.25um.
Agilent 19091Z-436 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.25mm. Length: 60m. Film Thickness: 0.25um.
Agilent 19091Z-513 Agilent HP-1 GC column Inner Diam.: 0.25 mm. Length: 30 m. Film thickness: 3.0 um. Similar Phases:. DB-1, Rtx-1, OV-1, SPB-1, SE-30, CP-Sil 5CB, RSL-150, MTX-1, BP-1, 007-1, MDN-1. Temperature Range isothermal/temperature programmed:. -60 to 325/350[degree]C. -60 to 300/320[degree]C for 0.53 mm i.d.
Agilent 19091Z-513E Agilent HP-1 Capillary GC Column Wound on 127 cage. Nonpolar. For the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 260[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness: 3um.
Agilent 19091Z-530 Agilent HP-1 MTBE Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds, specifically MTBE and ethanol. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.25mm. Length: 100m. Film Thickness: 0.5um.
Agilent 19091Z-530E Agilent HP-1 Capillary GC Column Wound on 127 cage. Nonpolar. For the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 325[degree]C. I.D.: 0.25mm. Length: 100m. Film Thickness: 0.5um.
Agilent 19091Z-577 Agilent Hp-1, 20M, 0.18Mm, 0.18Um
Agilent 19091Z-613 Agilent HP-1 GC column Inner Diam.: 0.25 mm. Length: 30 m. Film thickness: 4.0 um. Similar Phases:. DB-1, Rtx-1, OV-1, SPB-1, SE-30, CP-Sil 5CB, RSL-150, MTX-1, BP-1, 007-1, MDN-1. Temperature Range isothermal/temperature programmed:. -60 to 325/350[degree]C. -60 to 300/320[degree]C for 0.53 mm i.d.
Agilent 19091Z-713 Agilent HP-1 GC column Inner Diam.: 0.25 mm. Length: 30 m. Film thickness: 5.0 um. Similar Phases:. DB-1, Rtx-1, OV-1, SPB-1, SE-30, CP-Sil 5CB, RSL-150, MTX-1, BP-1, 007-1, MDN-1. Temperature Range isothermal/temperature programmed:. -60 to 325/350[degree]C. -60 to 300/320[degree]C for 0.53 mm i.d.
Agilent 19091Z-713E Agilent HP-1 Capillary GC Column Wound on 127 cage. Nonpolar. For the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 260[degree]C. I.D.: 0.32mm. Length: 30m. Film Thickness: 5um.
Agilent 19091Z-716 Agilent HP-1 GC column Inner Diam.: 0.25 mm. Length: 60 m. Film thickness: 5.0 um. Similar Phases:. DB-1, Rtx-1, OV-1, SPB-1, SE-30, CP-Sil 5CB, RSL-150, MTX-1, BP-1, 007-1, MDN-1. Temperature Range isothermal/temperature programmed:. -60 to 325/350[degree]C. -60 to 300/320[degree]C for 0.53 mm i.d.
Agilent 19091Z-716E Agilent GC Column, DB-FFAP 60m, 0.25mm, 0.25um, 5in cage
Agilent 19095-10050 Agilent Fused silica MESI coated (thin) Fused silica MESI coated (thin).
Agilent 19095-60510 Agilent HP 5880 Inlet Supplies Series 530 um Adapter Kit. Kit to adapt injection port for use with Series 530 um columns kit.
Agilent 19095F-120 Agilent HP-FFAP GC column Inner Diam.: 0.53 mm. Length: 15 m. Film Thickness: 1.0 um. The order of polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases.
Agilent 19095F-120E Agilent HP-FFAP Stabilwax-DA. Wound on 127mm cage. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 1500mm. Film: 1um. Temperature Range: 60 to 240[degree]C.
Agilent 19095F-121 Agilent HP-FFAP PEG Capillary GC Column Acid modified PEG column for analysis of acids, acrylates, alcohols, aldehydes, ketones, nitriles, free-fatty acids. Phase composition: bonded polyethylene glycol-TPA. Temperature Range: 60 to 230[degree]C. I.D.: 0.53mm. Length: 10m. Film Thickness: 1.0um.
Agilent 19095F-123 Agilent HP-FFAP PEG Capillary GC Column Acid modified PEG column for analysis of acids, acrylates, alcohols, aldehydes, ketones, nitriles, free-fatty acids. Phase composition: bonded polyethylene glycol-TPA. Temperature Range: 60 to 230[degree]C. I.D.: 0.53mm. Length: 30m. Film Thickness: 1.0um.
Agilent 19095F-123E Agilent HP-FFAP Stabilwax-DA. Wound on 127mm cage. Nitroterephthalic acid modified polyethylene glycol. High polarity. Designed for the analysis of volatile fatty acids and phenols. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 1um. Temperature Range: 60 to 240[degree]C.
Agilent 19095J-023 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 300/320[degree]C. I.D. 0.53mm. Length 30m. Thickness: 0.88um.
Agilent 19095J-023E Agilent HP5 Capillary GC Column Wound on 127mm cage. Nonpolar. For analysis of semivolatives, alkaloids, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 300/320[degree]C. I.D. 0.53mm. Length 30m. Film: 0.88um.
Agilent 19095J-121 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 300/320[degree]C. I.D. 0.53mm. Length 10m. Thickness: 2.65um.
Agilent 19095J-121E Agilent HP5 Capillary GC Column Wound on 127mm cage. Nonpolar. For analysis of semivolatives, alkaloids, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 300/320[degree]C. I.D. 0.53mm. Length 10m. Film: 2.65um.
Agilent 19095J-123 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 300/320[degree]C. I.D. 0.53mm. Length 30m. Thickness: 2.65um.
Agilent 19095J-123E Agilent HP5 Capillary GC Column Wound on 127mm cage. Nonpolar. For analysis of semivolatives, alkaloids, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 300/320[degree]C. I.D. 0.53mm. Length 30m. Film: 2.65um.
Agilent 19095J-321 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 300/320[degree]C. I.D. 0.53mm. Length 15m. Thickness: 1.5um.
Agilent 19095J-323 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 300/320[degree]C. I.D. 0.53mm. Length 30m. Thickness: 1.5um.
Agilent 19095J-323E Agilent HP5 Capillary GC Column Wound on 127mm cage. Nonpolar. For analysis of semivolatives, alkaloids, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 300/320[degree]C. I.D. 0.53mm. Length 30m. Film: 1.5um.
Agilent 19095J-621 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 300/320[degree]C. I.D. 0.53mm. Length 15m. Thickness: 5um.
Agilent 19095J-623 Agilent HP5 Capillary GC Column Nonpolar column for analysis of semivolatives, alkaloids, drugs, FAMEs, pesticides, herbicides, halogenated compounds, unknown samples. Phase composition: bonded 5% phenyl, 95% dimethylpolysiloxane. Range: -60 to 300/320[degree]C. I.D. 0.53mm. Length 30m. Thickness: 5um.
Agilent 19095J-623E Agilent GC Column, HP-88 30m, 0.25mm, 0.2um, 5in cage
Agilent 19095L-021 Agilent HP-50+ Capillary GC Column A medium polarity column for the analysis of polar compounds such as basic drugs, herbicides and chlorinated pesticides. Phase composition: bonded 50% phenyl, 50% dimethylsiloxane. Temperature Range: 40 to 280[degree]C. ID: 0.53mm. Length: 15m. Film Thickness: 1.0um.
Agilent 19095L-023 Agilent HP-50+ Capillary GC Column A medium polarity column for the analysis of basic polar compounds such as drugs, herbicides and chlorinated pesticides. Phase composition: bonded 50% phenyl, 50% dimethylsiloxane. Temperature Range: 40 to 280[degree]C. ID: 0.53mm. Length: 30m. Film Thickness: 1.0um.
Agilent 19095L-023E Agilent HP-50+ Capillary GC Column Wound on 127mm cage. Medium polarity. For analysis of basic polar compounds such as drugs, herbicides and chlorinated pesticides. Phase composition: bonded 50% phenyl, 50% dimethylsiloxane. Temperature Range: 40 to 280[degree]C. ID: 0.53mm. Length: 30m. Film: 1um.
Agilent 19095L-121 Agilent HP-17 Capillary GC Column An intermediate polarity column designed for analysis of polar compounds such as drugs, glycols, pesticides and steroids. Phase composition: non-bonded 50% phenyl, 50% methylsiloxane. Temperature Range: 15 to 260[degree]C. ID: 0.53mm. Length: 10m. Film Thickness: 2.0um.
Agilent 19095L-523 Agilent HP-50+ Capillary GC Column A medium polarity column for the analysis of basic drugs, herbicides and chlorinated pesticides. Phase composition: bonded 50% phenyl, 50% dimethylsiloxane. Temperature Range: 40 to 280[degree]C. ID: 0.53mm. Length: 30m. Film Thickness: 0.5um.
Agilent 19095L-523E Agilent GC Column, CYCLODEX-B 30m, 0.32mm, 0.25um, 5in cage
Agilent 19095N-121 Agilent HP-INNOWax GC column Inner Diameter 0.53 mm. Length: 15 m. Film Thickness: 1.0 um. The order of polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases.
Agilent 19095N-121E Agilent HP-INNOWax GC Column Wound on 127mm cage. HP-20M; SUPELCOWAX 10. Polyethylene glycol. High polarity. Column to column repeatability. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 1500mm. Film: 1um. Temperature Range: 40 to 260/270[degree]C.
Agilent 19095N-123 Agilent HP-INNOWax PEG Capillary GC Column PEG column for the analysis of alcohols, aromatics, essential oils, and free acids. Phase composition: INNOphase* bondable polyethylene glycol. Temperature Range: 40 to 240[degree]C. I.D.: 0.53mm. Length: 30m. Film Thickness: 1.0um.
Agilent 19095N-123E Agilent HP-INNOWax GC Column Wound on 127mm cage. HP-20M; SUPELCOWAX 10. Polyethylene glycol. High polarity. Column to column repeatability. Bonded and cross-linked. Solvent rinsable. 0.53mm ID. Length: 3000mm. Film: 1um. Temperature Range: 40 to 260/270[degree]C.
Agilent 19095N-126 Agilent HP-INNOWax PEG Capillary GC Column PEG column for the analysis of alcohols, aromatics, essential oils, and free acids. Phase composition: INNOphase* bondable polyethylene glycol. Temperature Range: 40 to 240[degree]C. I.D.: 0.53mm. Length: 60m. Film Thickness: 1.0um.
Agilent 19095P-K23 Agilent HP-PLOT Al2O3 "KCI" Deactivation GC column Inner Diam.: 0.53 mm. Length: 30 m. Film Thickness: 15 um. The order of polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases:.
Agilent 19095P-K25 Agilent HP-PLOT Al2O3 "KCI" Deactivation GC column Inner Diam.: 0.53 mm. Length: 50 m. Film Thickness: 15 um. The order of polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more polar than, the HP-20M (Carbowax 20M) columns.1. Similar Phases:.
Agilent 19095P-M23 Agilent HP-PLOT Al2O3 "M" Capillary GC Column PLOT (porous layer open tubular) column designed for the analysis of light hydrocarbons (C1 to C6), resolving cyclopropane from propylene. Phase composition: Aluminum oxide. Temperature Range: up to 200[degree]C. ID: 0.53mm. Length: 30m. Film Thickness: 15um.
Agilent 19095P-M25 Agilent HP-PLOT Al2O3 "M" Deactivation GC column Inner Diam.: 0.53 mm. Length: 50 m. Film Thickness: 15 um. The order of polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases:.
Agilent 19095P-M25E Agilent GC Column, DB-17MS 60m, 0.25mm, 0.25um, 5in cage
Agilent 19095P-MS0 Agilent HP-PLOT Molecular Sieve 5A Capillary GC Column Thick-film PLOT column for air monitoring applications and analyzing noble gases. Resolve argon and oxygen at ambient temperatures. Phase composition: 5A zeolite. Temperature Range: up to 350[degree]C. I.D.: 0.53mm. Length: 30m. Film Thickness: 50um.
Agilent 19095P-MS0E Agilent HP-PLOT Molecular Sieve 5A Capillary GC Column Wound on 127mm cage. Thick-film PLOT. For air monitoring applications and analyzing noble gases. Resolve argon and oxygen at ambient temperatures. Composition: 5A zeolite. Temperature Range: up to 350[degree]C. I.D.: 0.53mm. Length: 30m. Film: 50um.
Agilent 19095P-MS5 Agilent HP-PLOT Molecular Sieve 5A Capillary GC Column Thin-film PLOT column for air monitoring applications and analyzing noble gases. Resolve argon and oxygen at subambient temperatures. Phase composition: 5A zeolite. Temperature Range: up to 350[degree]C. I.D.: 0.53mm. Length: 15m. Film Thickness: 25um.
Agilent 19095P-MS6 Agilent HP-PLOT Molecular Sieve 5A Capillary GC Column Thin-film PLOT column for air monitoring applications and analyzing noble gases. Resolve argon and oxygen at subambient temperatures. Phase composition: 5A zeolite. Temperature Range: up to 350[degree]C. I.D.: 0.53mm. Length: 30m. Film Thickness: 25um.
Agilent 19095P-MS9 Agilent HP-PLOT Molecular Sieve 5A Capillary GC Column Thick-film PLOT column for air monitoring applications and analyzing noble gases. Resolve argon and oxygen at ambient temperatures. Phase composition: 5A zeolite. Temperature Range: up to 350[degree]C. I.D.: 0.53mm. Length: 15m. Film Thickness: 50um.
Agilent 19095P-QO3 Agilent HP-PLOT Q GC column Inner Diam.: 0.53 mm. Length: 15 m. Film Thickness: 40 um. Based on a polystyrene-divinylbenzene (DVB) stationary phase the new HP-PLOT Q columns stand out through their capability of separating all C1 to C3 hydrocarbon isomers at 60[degree]C.
Agilent 19095P-QO3E Agilent HP-PLOT Q CP PoraPlot Q. Wound on 127mm cage. Bonded polystyrene-divinylbenzene based column. Separates ethane, ethlene, and ethyne (acetylene). 0.53mm ID. Length: 1500mm. Film: 40um. Temperature Range: -60 to 270/290[degree]C.
Agilent 19095P-QO4 Agilent HP-PLOT Q GC column Inner Diam.: 0.53 mm. Length: 30 m. Film Thickness: 40 um. Based on a polystyrene-divinylbenzene (DVB) stationary phase the new HP-PLOT Q columns stand out through their capability of separating all C1 to C3 hydrocarbon isomers at 60[degree]C.
Agilent 19095P-QO4E Agilent GC Column
Agilent 19095P-S21 Agilent HP-PLOT Al2O3 "S" Deactivation GC column Inner Diam.: 0.53 mm. Length: 15 m. Film Thickness: 15 um. The order of polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases:.
Agilent 19095P-S23 Agilent HP-PLOT Al2O3 "S" Deactivation GC column Inner Diam.: 0.53 mm. Length: 30 m. Film Thickness: 15 um. The order of polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases:.
Agilent 19095P-S25 Agilent HP-PLOT Al2O3 "S" Deactivation GC column Inner Diam.: 0.53 mm. Length: 50 m. Film Thickness: 15 um. The order of polarity is as follows: HP-INNOWax columns are more polar than HP-WAX columns, which in turn are more polar than, the HP-20M (Carbowax 20M) columns. Similar Phases:.
Agilent 19095P-S25E Agilent HP-PLOT AI2O3-S Wound on 127mm cage. Middle range of polarity for alumina phases. General purpose column for light hydrocarbon analysis. Best for resolving acetylene from butane and propylene from isobutane. 0.53mm ID. Length: 5000mm. Film: 15um. Temperature Range: -60 to 200[degree]C.
Agilent 19095P-UO3 Agilent HP-PLOT U CP PoraPlot U. Bonded divinylbenzene/ethylene glycol dimethacrylate. Column for C1 to C7 hydrocarbons, CO2, methane, air/CO, water, solvents, amines, alcohols, and more. 0.53mm ID. Length: 1500mm. Film: 20um. Temperature Range: -60 to 190[degree]C.
Agilent 19095P-UO4 Agilent HP-PLOT U CP PoraPlot U. Bonded divinylbenzene/ethylene glycol dimethacrylate. Column for C1 to C7 hydrocarbons, CO2, methane, air/CO, water, solvents, amines, alcohols, and more. 0.53mm ID. Length: 3000mm. Film: 20um. Temperature Range: -60 to 190[degree]C.
Agilent 19095P-UO4E Agilent HP-PLOT U CP PoraPlot U. Wound on 127mm cage. Bonded divinylbenzene/ethylene glycol dimethacrylate. Column for C1 to C7 hydrocarbons, CO2, methane, air/CO, water, solvents, amines, alcohols, and more. 0.53mm ID. Length: 3000mm. Film: 20um. Temperature Range: -60 to 190[degree]C.
Agilent 19095R-420 Agilent HP-VOC Environmental Capillary GC Column Intermediate polarity column for the analysis of volatile organics. Recommended for EPA Methods 502.2, 524.2, 601, 602, 8024, and 8260. Temperature Range: -60 to 280[degree]C. ID: 0.53mm. Length: 105m. Film Thickness: 3.0um.
Agilent 19095R-429 Agilent HP-VOC GC column Inner Diam.: 0.53 mm. Length: 90 m. Film Thickness: 3.0 um. Similar Phases. Rtx-502.2, DB-502.2, Rtx-Volatiles, Supelco VOCOL. Temperature Range. -60 to 280[degree]C. Developed to meet the challenges of EPA Method 502.
Agilent 19095S-100 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 300[degree]C. I.D.: 0.53mm. Length: 5m. Film Thickness: 2.65um.
Agilent 19095S-100E Agilent HP-1 Capillary GC Column Wound on 127mm cage. A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 300[degree]C. I.D.: 0.53mm. Length: 5m. Film Thickness: 2.65um.
Agilent 19095S-200 Agilent
Agilent 19095V-420E Agilent HP-Fast Residual Solvent Column Wound on 127mm cage. Bonded and cross-linked. 0.53mm ID. Length: 3000mm. Film: 1um. Temperature Range: -20 to 260[degree]C.
Agilent 19095W-121 Agilent HP-20M Non-Bonded PEG Capillary GC Column PEG column for the analysis of alcohols, glycols, essential oils, ethers, solvents, and free acids. Phase composition: non-bonded polyethylene glycol. Temperature Range: 60 to 220[degree]C. I.D.: 0.53m. Length: 10m. Film Thickness: 1.33um.
Agilent 19095W-123 Agilent HP-20M Non-Bonded PEG Capillary GC Column PEG column for the analysis of alcohols, glycols, essential oils, ethers, solvents, and free acids. Phase composition: non-bonded polyethylene glycol. Temperature Range: 60 to 220[degree]C. I.D.: 0.53m. Length: 30m. Film Thickness: 1.33um.
Agilent 19095Z-020 Agilent HP-1 GC column Inner Diam.: 0.53 mm. Length: 5 m. Film thickness: 0.88 um. These columns are coated with high temperature polyimide, allowing temperature programmed operation up to 400[degree]C. The lifetime of the column at 400[degree]C is about 50 hours. Similar Phases:.
Agilent 19095Z-021 Agilent HP-1 GC column Inner Diam.: 0.53 mm. Length: 10 m. Film thickness: 0.88 um. Similar Phases:. DB-1, Rtx-1, OV-1, SPB-1, SE-30, CP-Sil 5CB, RSL-150, MTX-1, BP-1, 007-1, MDN-1. Temperature Range isothermal/temperature programmed:. -60 to 325/350[degree]C. -60 to 300/320[degree]C for 0.53 mm i.d.
Agilent 19095Z-021E Agilent GC Column, HP-1 10m, 0.53mm, 0.88um, 5in cage
Agilent 19095Z-023 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 300[degree]C. I.D.: 0.53mm. Length: 30m. Film Thickness: 0.88um.
Agilent 19095Z-023E Agilent GC Column, HP-5 30m, 0.53mm, 5.0um, 5in cage
Agilent 19095Z-121 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 300[degree]C. I.D.: 0.53mm. Length: 10m. Film Thickness: 2.65um.
Agilent 19095Z-121E Agilent HP-1 Capillary GC Column Wound on 127mm cage. Nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 300[degree]C. I.D.: 0.53mm. Length: 10m. Film Thickness: 2.65um.
Agilent 19095Z-123 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 300[degree]C. I.D.: 0.53mm. Length: 30m. Film Thickness: 2.65um.
Agilent 19095Z-123E Agilent HP-1 Capillary GC Column Wound on 127mm cage. A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 300[degree]C. I.D.: 0.53mm. Length: 30m. Film Thickness: 2.65um.
Agilent 19095Z-220 Agilent HP-1 GC column Inner Diam.: 0.53 mm. Length: 5 m. Film thickness: 0.15 um. These columns are coated with high temperature polyimide, allowing temperature programmed operation up to 400[degree]C. The lifetime of the column at 400[degree]C is about 50 hours. Similar Phases:.
Agilent 19095Z-221 Agilent Extended SIMDIST Petroleum Analyses Capillary GC Column For extended simulated distillations of heavy petroleums and waxes. Temperature Range: up to 400[degree]C. I.D.: 0.53mm. Length: 15m. Film Thickness: 0.15um.
Agilent 19095Z-221E Agilent Extended SIMDIST Petroleum Analyses Capillary GC Column Wound on 127mm cage. For extended simulated distillations of heavy petroleums and waxes. Temperature Range: up to 400[degree]C. I.D.: 0.53mm. Length: 15m. Film Thickness: 0.15um.
Agilent 19095Z-321 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 300[degree]C. I.D.: 0.53mm. Length: 15m. Film Thickness: 1.5um.
Agilent 19095Z-321E Agilent GC Column, HP-5, 15m, 0.32mm, 0.25um, 5in cage
Agilent 19095Z-323 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 300[degree]C. I.D.: 0.53mm. Length: 30m. Film Thickness: 1.5um.
Agilent 19095Z-323E Agilent HP-1 Capillary GC Column Wound on 127mm cage. A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 300[degree]C. I.D.: 0.53mm. Length: 30m. Film Thickness: 1.5um.
Agilent 19095Z-421 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 300[degree]C. I.D.: 0.53mm. Length: 15m. Film Thickness: 3.0um.
Agilent 19095Z-421E Agilent HP-1 Capillary GC Column Wound on 127mm cage. A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 300[degree]C. I.D.: 0.53mm. Length: 15m. Film Thickness: 3.0um.
Agilent 19095Z-423 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 300[degree]C. I.D.: 0.53mm. Length: 30m. Film Thickness: 3.0um.
Agilent 19095Z-423E Agilent GC Column
Agilent 19095Z-621 Agilent HP-1 GC column Inner Diam.: 0.53 mm. Length: 15 m. Film thickness: 5.0 um. Similar Phases:. DB-1, Rtx-1, OV-1, SPB-1, SE-30, CP-Sil 5CB, RSL-150, MTX-1, BP-1, 007-1, MDN-1. Temperature Range isothermal/temperature programmed:. -60 to 325/350[degree]C. -60 to 300/320[degree]C for 0.53 mm i.d.
Agilent 19095Z-623 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 300[degree]C. I.D.: 0.53mm. Length: 30m. Film Thickness: 5.0um.
Agilent 19095Z-626 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 300[degree]C. I.D.: 0.53mm. Length: 60m. Film Thickness: 5.0um.
Agilent 19095Z-627 Agilent HP-1 Capillary GC Column A nonpolar column for the analysis of amines, hydrocarbons, PCBs, pesticides, phenols and sulfur compounds. Bonded 100% polydimethylsiloxane. Temperature Range: -60 to 300[degree]C. I.D.: 0.53mm. Length: 7.5m. Film Thickness: 5.0um.
Agilent 19095Z-627E Agilent GC Column, HP-1 7.5m, 0.53mm, 5.0um, 5in cage
Agilent 1909BD-113 Agilent Biodiesel EN14103 FAME Analysis 30m x 0.32mm x 0.25um
Agilent 19199M Agilent GC Instrument Supplies Installation Kit for HP 5890 without Gas Purifier System. Includes.
Agilent 19199N Agilent GC Instrument Supplies Installation Kit for HP 5890 with Gas Purifier System. 1/8 in. fittings. Glass indicating oxygen trap, preconditioned moisture trap, hydrocarbon trap, He/H2 combination gas purifier and items listed under kit HP 5890.
Agilent 19231-20910 Agilent HP 5890 Detector Supplies FID Supplies. Ignitor castle.
Agilent 19231-20940 Agilent HP 5890 Detector Supplies FID Supplies. Collector nut.
Agilent 19231-20950 Agilent HP 5890 Detector Supplies FID Supplies. Lower collector insulator.
Agilent 19231-20960 Agilent HP 5890 Detector Supplies FID Supplies. Collector body.
Agilent 19231-20970 Agilent HP 5890 Detector Supplies FID Supplies. Upper collector insulator.
Agilent 19231-21050 Agilent HP 5890 Detector Supplies FID Supplies. PTFE chimney (optional).
Agilent 19231-21060 Agilent HP 5890 Detector Supplies FID Supplies. Optional hastelloy castle.
Agilent 19231-21080 Agilent HP 5890 Detector Supplies FID Supplies. Optional hastelloy collector.
Agilent 19231-60680 Agilent HP 5890 Detector Supplies FID Supplies. Ignitor (glow plug) assembly.
Agilent 19231-60690 Agilent HP 5890 Detector Supplies FID Supplies. Collector assembly: (contains items 2-10).
Agilent 19231-60790 Agilent Chemical Filters/Traps Detector trap replacement kit.
Agilent 19231-80520 Agilent HP 5890 Detector Supplies FID and NPD Adapters. FID/NPD 1/8 in. packed column.
Agilent 19231-80530 Agilent HP 5890 Detector Supplies FID and NPD Adapters. FID/NPD 1/4 in. packed column.
Agilent 19231-80590 Agilent Chemical Filters/Traps Replacement detector stainless steel trap.
Agilent 19232-60676 Agilent HP 5890 Detector Supplies TCD replacement cartridge.
Agilent 19232-80550 Agilent HP 5890 Detector Supplies Makeup gas adapter, TCD.
Agilent 19233-20625 Agilent HP 5890 Detector Supplies Electron Capture Detector. ECD fused silica liner (new style).
Agilent 19233-20755 Agilent HP 5890 Detector Supplies Electron Capture Detector. Stainless steel cap for ECD makeup gas adapter (new style and micro ECD).
Agilent 19233-80565 Agilent HP 5890 Detector Supplies Electron Capture Detector. Makeup gas adapter, ECD, new style.
Agilent 19234-60540 Agilent HP 5890 Detector Supplies NPD Supplies. NPD collector (NPD bead).
Agilent 19234-60720 Agilent HP 5890 Detector Supplies FID Supplies. Detector nut warmer.
Agilent 19243-00070 Agilent HP 5890 Split/Splitless Multimode Inlet Split/Splitless Inlet Parts. Lower insulation cover.
Agilent 19243-60500 Agilent Headspace Septum Nut Universal packed column inlet (non-purged) supplies. Non EPC. For non-purged packed inlets.
Agilent 19243-60505 Agilent HP 5890 Packed Column Inlet Supplies Universal Packed Column Inlet (non-purged). Septum retainer nut.
Agilent 19243-60570 Agilent HP 5890 Packed Column Inlet Supplies Septum-Purged Packed Column Inlet. Nonpurging septum nut assembly for manual flow control only, not EPC.
Agilent 19243-80510 Agilent HP 5880 Inlet Supplies Liner/adapter for using other column types in the 1/4 in. port. 1/8 in. metal columns.
Agilent 19243-80520 Agilent HP 5890 Packed Column Inlet Supplies Septum-Purged Packed Column Inlet. Adapters without glass liners: 1/4 in. column adapter.
Agilent 19243-80530 Agilent HP 5890 Packed Column Inlet Supplies Septum-Purged Packed Column Inlet. Adapter with glass liners: 1/8 in. column adapter.
Agilent 19243-80540 Agilent HP 5890 Packed Column Inlet Supplies Septum-Purged Packed Column Inlet. Adapter with glass liners: 1/4 in. column adapter.
Agilent 19243-80550 Agilent Jumper, weldment Jumper, weldment.
Agilent 19243-80570 Agilent HP 5890 Packed Column Inlet Supplies Septum-Purged Packed Column Inlet. Top insert weldment.
Agilent 19244-80540 Agilent HP 5880 Inlet Supplies Series 530 um Adapter Kit. Injection port liner for 530 um column.
Agilent 19244-80560 Agilent HP 5890 Detector Supplies Jets. Capillary/Series 530 um Jet, adaptable capillary (0.29mm ID tip).
Agilent 19244-80610 Agilent HP 5890 Detector Supplies FID and NPD Adapters. FID/NPD capillary column.
Agilent 19244-80620 Agilent HP 5890 Detector Supplies Jets. High-temperature jet (for simulated distillation).
Agilent 19245-20510 Agilent HP 5890 Cool On-Column (COC) Inlets Manual Injection. Inserts for capillary columns: For 200 um columns (1 silver ring).
Agilent 19245-20515 Agilent VWR* Critical Cover* GenPro* Cover General purpose light weight round cover with elastic for product protection in critical environments. 91.4 x 91.4 cm.
Agilent 19245-20525 Agilent HP 5890 Cool On-Column (COC) Inlets Manual Injection. Inserts for capillary columns: For 320 um columns (5 silver rings).
Agilent 19245-20580 Agilent HP 5890 Cool On-Column (COC) Inlets Manual Injection. Inserts for capillary columns: For 530 um columns (no rings).
Agilent 19245-20670 Agilent HP 5890 Cool On-Column (COC) Inlets Automatic Injection. Needle guide (for HP 7673A only). First automatic direct cool on-column injection into 320 um and 250 um diameter columns.
Agilent 19245-20780 Agilent HP 5890 Cool On-Column (COC) Inlets Manual Injection. Inserts for capillary columns: For 530 um Al clad columns (4 rings).
Agilent 19245-40050 Agilent HP 5890 Cool On-Column (COC) Inlets Manual Injection. Duckbill.
Agilent 19245-60760 Agilent HP 5890 Cool On-Column (COC) Inlets Manual Injection. Spring: For HP 5890 Series II GC.
Agilent 19245-80520 Agilent HP 5890 Cool On-Column (COC) Inlets Automatic Injection. Septum nut (HP 5890 Series II GC). First automatic direct cool on-column injection into 320 um and 250 um diameter columns.
Agilent 19246-60526 Agilent Pressure Gauge For Agilent 6890/5890 Regulators, Mass Flow Controllers, and Restrictors. 0-15psig (0-100kPa).
Agilent 19246-60550 Agilent Pressure regulator 0-100 psi Pressure regulator 0-100 psi.
Agilent 19246-60560 Agilent Back pressure regulator, 0-15 psi Back pressure regulator, 0-15 psi.
Agilent 19246-60570 Agilent Back pressure regulator, 0-30 psi Back pressure regulator, 0-30 psi.
Agilent 19246-60580 Agilent Back pressure regulator, 0-60 psi Back pressure regulator, 0-60 psi.
Agilent 19246-60620 Agilent Back pressure regulator w/gauge, 0-15 psi Back pressure regulator w/gauge, 0-15 psi.
Agilent 19246-60630 Agilent Back pressure regulator w/gauge, 0-60 psi Back pressure regulator w/gauge, 0-60 psi.
Agilent 19246-60690 Agilent Back pressure regulator, 0-100 psi Back pressure regulator, 0-100 psi.
Agilent 19251-00100 Agilent Angled Wrench For split/splitless septum nut and weldment.
Agilent 19251-20620 Agilent HP 5890 Split/Splitless Multimode Inlet Split/Splitless Inlet Parts. Retaining nut.
Agilent 19251-60540 Agilent Split/Splitless Liner for Capillary Inlet Systems 4mm ID. Volume: 990uL. For labile sampling and wide boiling ranges. Borosilicate glass. 10gm silanized glass wool packing.
Agilent 19251-60575 Agilent HP 5890 Split/Splitless Multimode Inlet Split/Splitless Inlet Parts. Split/splitless insert weldment with tubing.
Agilent 19251-60700 Agilent Thermal upgrade kit Use to enhance the performace of pre 1991 5890s with split inlets.
Agilent 19251-80680 Agilent HP Deactivated Retention Gaps and Column Accessories Column ferrule installation tool. Using an HP proprietary deactivation process, we are manufacturing retention gaps that will not degrade the performance of your chromatographic column.
Agilent 19251C Agilent Split vent trap 5890 GC (internal).
Agilent 19256-60500 Agilent HP 5890 Detector Supplies FPD Supplies. Start-up kit.
Agilent 19256-60590 Agilent HP 5890 Detector Supplies FPD Supplies. Liner/ferrule kit.
Agilent 19256-80000 Agilent HP 5890 Detector Supplies FPD Supplies. Sulfur filter.
Agilent 19256-80010 Agilent HP 5890 Detector Supplies FPD Supplies. Phosphorus filter.
Agilent 19256-80030 Agilent HP 5890 Detector Supplies FPD Supplies. Window, heat shield, 1st.
Agilent 19256-80060 Agilent HP 5890 Detector Supplies FPD Supplies. Window, heat shield, 2nd.
Agilent 19256-80570 Agilent HP 5890 Detector Supplies FPD Supplies. Adapter weldment, capillary.
Agilent 19256-80590 Agilent HP 5890 Detector Supplies FPD Supplies. Adapter weldment, 1/8 in. columns.
Agilent 19258-20830 Agilent HP 7694 Headspace Analysis Supplies Transfer line nut.
Agilent 19258-20870 Agilent HP 7694 Headspace Analysis Supplies Transfer line ferrule.
Agilent 1925820920 Agilent
Agilent 19298-60500 Agilent MIDI System Calibration Standard Miscellaneous Qualitative Standards. Quantitative calibration standard for the Microbial ID System. Fatty acid methyl esters w/v%. 0.01% n-C9:0, 0.02% n-C10:0, 0.01% n-C11:0, 0.02% C12.0, 0.01% C13:0, 0.02% C14:0, 0.01% n-C15:0, 0.02% n-C16:0, 0.01% n-C17:0, 0.
Agilent 19301-00150 Agilent Special Instrument Tools Septum Nut Wrenches. FID retainer nut wrench (HP 5880, 5890, 6890).
Agilent 19301-20720 Agilent HP 6890 Detector Supplies FID Consumables. Detector cleaning wire.
Agilent 19301-60660 Agilent HP 5880 Detector Supplies Flame Ionization Detector (FID). FID flow measuring insert.
Agilent 19301-80530 Agilent HP 5890 Detector Supplies Electron Capture Detector. ECD column adapter, 1/4 to 1/8 in. metal.
Agilent 19302-80020 Agilent HP 5890 Detector Supplies TCD column adapter, 1/8 to 1/4 in. glass.
Agilent 19305-60580 Agilent HP 5880 Detector Supplies Flame Photometric Detector (FPD). Performance evaluation sample, FPD.
Agilent 19320-60656 Agilent Pressure gauge, 0-30psi Pressure gauge, 0-30psi.
Agilent 19320-80625 Agilent HP 5890 Cool On-Column (COC) Inlets Manual Injection. Cooling tower assembly.
Agilent 19325-60660 Agilent GC Valves and Loops Compatible with HP 5890/6890 Valve-Related Parts. Air actuator.
Agilent 19350-60540 Agilent HP 5880 Inlet Supplies General Supplies for the HP 5880A GC. Replacement thermal printhead for HP 5880A and HP 3388A terminals.
Agilent 19354-60510 Agilent Qualitative Standards Miscellaneous Qualitative Standards. Nickel Catalyst. Mixture of 10+/-5 ppm each of methane, carbon monoxide, and carbon dioxide in helium. One pressurized container (370 ml at 25 psig).
Agilent 19361-60566 Agilent Pressure gauge, 0-100psi Pressure gauge, 0-100psi.
Agilent 19361-80120 Agilent Jumper tube 360mm for TCD Jumper tube 360mm for TCD.
Agilent 19362-60510 Agilent MFC Restrictor 0-20 ml/min, old style Red color code, silver color dot.
Agilent 19362-60515 Agilent MFC Restrictor 0-20 ml/min Red and purple color dot code.
Agilent 19362-60520 Agilent MFC Restrictor 0-60 ml/min, old style Red color code.
Agilent 19362-60525 Agilent MFC Restrictor 0-60 ml/min Blue and purple color dot code.
Agilent 19362-60530 Agilent MFC Restrictor 0-110 ml/min, old style Green color code.
Agilent 19362-60535 Agilent MFC Restrictor 0-110 ml/min Green and purple color dot code.
Agilent 19362-60540 Agilent MFC Restrictor 0-400 ml/min, old style Black color code.
Agilent 19362-60545 Agilent MFC Restrictor 0-400 ml/min Black and purple color dot code.
Agilent 19362-60555 Agilent MFC Restrictor 0-750 ml/min Yellow and purple color dot code.
Agilent 19362-60565 Agilent Mass Flow Controller 0-20 ml/min For use with packed column inlets.
Agilent 19362-60575 Agilent Mass Flow Controller 0-400 cc/min For use with capillary inlets.
Agilent 19363-60506 Agilent Pressure gauge, 0-60psi Pressure gauge, 0-60psi.
Agilent 1970-0201 Agilent Photomultiplier, 1046A Photomultiplier, 1046A.
Agilent 1970-0216 Agilent General GC/MS Supplies and Electron Multipliers Galileo Electron Multiplier for use with 5970. Electron Multipliers and Replacement Horns.
Agilent 200-0070 Agilent Column Test Standards, DB-WAX For microbore. 0.05 & 0.10 mm I.D. Compare your column's performance to the test chromatogram shipped with your J&W column. The column test standard contains components that test the column for resolution characteristics columns efficiency, and inertness.
Agilent 200-0185 Agilent Column Test Standards, DB-5ms For capillary. 0.18 to 0.32 mm I.D. Compare your column's performance to the test chromatogram shipped with your J&W column. The column test standard contains components that test the column for resolution characteristics columns efficiency, and inertness.
Agilent 200-0310 Agilent QA/QC Capillary Column Test Standard
Agilent 210-2066-H Agilent Liners, HP5880 / 5890 / 6890 / 4890 Hot On-column, I.D.: 4.0 mm. Wool Packing: N. Dimensions 6.3 x 78.5.
Agilent 210-3003 Agilent Liners, HP5880 / 5890 / 6890 / 4890 Straight. I.D.: 4.0 mm. Wool Packing: N. Dimensions 6.3 x 78.5. Straight Liners provide the ultimate flexibility for injections. You can easily pack these liners with glass wool. Also, Straight Liners can be easily cleaned and regenerated.
Agilent 210-3003-5 Agilent Liners, HP5880 / 5890 / 6890 / 4890 Straight. I.D.: 4.0 mm. Wool Packing: N. Dimensions 6.3 x 78.5. Straight Liners provide the ultimate flexibility for injections. You can easily pack these liners with glass wool. Also, Straight Liners can be easily cleaned and regenerated.
Agilent 210-4004-5 Agilent Liners, HP5880 / 5890 / 6890 / 4890 FocusLiner. I.D.: 4.0 mm. Wool Packing: Y. Dimensions 6.3 x 78.5. Improve reproducibility, improve results. The FocusLiner traps a glass wool plug in the ideal position in the injection portliner.
Agilent 2140-0813 Agilent Deuterium Lamp 1100DAD/MWD longlife - A 58.
Agilent 220-1170 Agilent ADM1000 Flowmeter Portable. Microprocessor controlled. Digital. Measures flow rates from 0.1 to 1000ml/minute with accuracy of +-3%. Autoranging LCD display with continuous reading of split flow ratios. Measures all non-corrosive gases. Calibrated and traceable to NIST standards. 9V battery.
Agilent 220-1171-U Agilent ADM2000 Flowmeter Accurately measures flow rates from 0.1 to 1000ml/minute, accurate to +-3%. Digital display with continuous reading of split flow ratios. Measures all non-corrosive gases. RS 232 data port. Mass flow rate measurement (sccm). Calibrated and traceable to NIST standards. 9V or AC.
Agilent 220-1179 Agilent Tubing Extender Kit Flowmeter.
Agilent 2307230001 Agilent Union Zero dead volume, deactivated.
Agilent 2307232901 Agilent Union For use with the G1888A Headspace.
Agilent 2307601004 Agilent Tubing Assembly 6-port valve to solenoid valves, deactivated.
Agilent 2321700003 Agilent Sample loop Headspace deactivated 1mL.
Agilent 2321700004 Agilent Sample Loop Headspace deactivated 3mL.
Agilent 2322590004 Agilent Needle Headspace Transfer line 0.5mm OD.
Agilent 2322590005 Agilent Needle Headspace Transfer line 0.7mm OD.
Agilent 2322700011 Agilent Sample probe For G1888A, deactivated.
Agilent 232279012EHS Agilent Needle Assembly Vial Probe Needle assembly vial probe, deactivated
Agilent 250-030-DAN Agilent Silicone septa, pack of 100
Agilent 280959-001 Agilent Frit, 2um for 9.4mm id columns Frit, 2um for 9.4mm id columns.
Agilent 280959-006 Agilent Frit, 2um for 3.0mm id columns Frit, 2um for 3.0mm id columns.
Agilent 301-011-HSP Agilent HP 7694 Headspace Analysis Supplies Transfer line, 80 cm, nickel.
Agilent 301-017-HSP Agilent HP 7694 Headspace Analysis Supplies Oven adaptor for 10 ml vials.
Agilent 301-152-HSP Agilent HP 7694 Headspace Analysis Supplies Transfer line, 1 m, nickel.
Agilent 301-162-HSP Agilent Tube, pressure or flow tee, 7694 Tube, pressure or flow tee, 7694.
Agilent 301-163-HSP Agilent Valve For assy tube press kit.
Agilent 301-164-HSP Agilent Tube, T-six port valve Tube, T-six port valve.
Agilent 301-168-HSP Agilent Tube, T-six port valve Tube, T-six port valve.
Agilent 301-169-HSP Agilent HP 7694 Headspace Analysis Supplies Tube, needle, 6-port valve, nickel.
Agilent 301-170-HSP Agilent HP 7694 Headspace Analysis Supplies Tube, vent-valve stainless steel.
Agilent 301-171-HSP Agilent Tube, bulkhead-pressure regulator Tube, bulkhead-pressure regulator.
Agilent 301-212-HSP Agilent HP 7694 Headspace Analysis Supplies Tube, needle, 6-port valve, Silcosteel.
Agilent 303-0034 Agilent Screw 6-32 x 1/4, Pan, Phil, Int Sim.
Agilent 3150-0374 Agilent HP 5921/G2350A Atomic Emission Detector Supplies HP 5921/G2350A Common Parts. 1/4 in. filter-60 um water filter element (external water system only). Environmental laboratories are using the Atomic Emission Detector (AED) to make GC analysis of unknowns faster and more accurate.
Agilent 3150-0404 Agilent Filter, 7um Replacement for in-line filter 0101-0532, used with GC effluent splitters.
Agilent 3150-0417 Agilent HP 5921/G2350A Atomic Emission Detector Supplies HP 5921/G2350A Common Parts. Fly ash filter. Environmental laboratories are using the Atomic Emission Detector (AED) to make GC analysis of unknowns faster and more accurate.
Agilent 3150-0462 Agilent General Parts and Supplies for HP1090 Large air filter for HP 1090 mainframe.
Agilent 3150-0463 Agilent General Parts and Supplies for HP1090 Small dust filter for HP 1090 mainframe.
Agilent 3150-0509 Agilent Fluoropolymer resin filter membrane 47mm 10/pk Pore size 1-2 um -compatible with all solvents, acids and bases- contains no extractables which might compromise the filtrate- inherently hydrophobic, however, can be used for both organic and aqueous solvents
Agilent 3150-0559 Agilent HP 59980B Particle Beam Supplies Frits. LC/MS Supplies.
Agilent 3150-0617 Agilent HP 5921/G2350A Atomic Emission Detector Supplies HP 5921/G2350A Common Parts. 1/4 in. filter-5 um water filter element (internal water system only). Environmental laboratories are using the Atomic Emission Detector (AED) to make GC analysis of unknowns faster and more accurate.
Agilent 3150-0619 Agilent Air filter, 5 um Spare Parts. CE AND CE/MS.
Agilent 3150-0942 Agilent General Parts and Supplies for HP1090 Helium inlet.
Agilent 3150-0944 Agilent Glass Filter, Solvent Inlet For Agilent G1361A 1100 Series Preparative Pump. 40um pore size.
Agilent 3162-0083 Agilent HP 5985/87/88 Parts and Supplies Copper wool trap material for Leybold D8A rough pumps and Edwards rough pumps on HP 5985B with LC/MS. Vacuum System Supplies.
Agilent 3162-0110 Agilent O-ring kit O-ring kit.
Agilent 321-002-HSP Agilent HP 7694 Headspace Analysis Supplies Restrictor, stainless steel.
Agilent 321-055-HSP Agilent HP 7694 Headspace Analysis Supplies Sample loop, 1 cc, nickel.
Agilent 321-056-HSP Agilent HP 7694 Headspace Analysis Supplies Sample loop, 3 cc, nickel.
Agilent 321-057-HSP Agilent Sensor tube, 125mm PTFE Sensor tube, 125mm PTFE.
Agilent 325-0016 Agilent Fluoropolymer resin Insert 1.6mm.
Agilent 325-019-HSP Agilent Nylon washer 4.8 x 8.0 x 0.5m Nylon washer 4.8 x 8.0 x 0.5m.
Agilent 325-045-HSP Agilent HP 7694 Headspace Analysis Supplies Zero dead volume union.
Agilent 325-062-HSP Agilent Union FF 6 MB 5 piece set Union FF 6 MB 5 piece set.
Agilent 325-132-HSP Agilent Union Tee 6MB-5.
Agilent 325-185-HSP Agilent Union T 5 MA, SS Union T 5 MA, SS.
Agilent 325-455-HSP Agilent Nut Stainless Steel, 5mm.
Agilent 330-055-HSP Agilent HP 7694 Headspace Analysis Supplies Flow controller.
Agilent 35900-60570 Agilent Analog signal cable, 5880 to integrator Analog signal cable, 5880 to integrator.
Agilent 35900-60600 Agilent Cables from HP Integrators to HP 1090 Series, HP 1040 Diode-Array Detector Analog.
Agilent 35900-60620 Agilent Analog signal cable, 5710/30 to integrator Analog signal cable, 5710/30 to integrator.
Agilent 35900-60630 Agilent Cables from HP Integrators to General Purpose Analog.
Agilent 35900-60640 Agilent Analog signal cable for special purpose From integrator to square pins.
Agilent 35900-60670 Agilent Instrument Interface Cables Remote start cable for general use with lug.
Agilent 35900-60700 Agilent Remote cable to 5890 Remote cable to 5890.
Agilent 35900-60710 Agilent Remote cable to 1090 Remote cable to 1090.
Agilent 35900-60750 Agilent Cables from HP Integrators to HP 1050 Series Analog.
Agilent 35900-60900 Agilent Analog signal for general purpose, 5m Analog signal for general purpose, 5m.
Agilent 35900-60910 Agilent Analog signal for general purpose, 15m Analog signal for general purpose, 15m.
Agilent 35900-60920 Agilent Remote cable for general purpose, 5m Remote cable for general purpose, 5m.
Agilent 35900-60960 Agilent Y-Remote Adapter Cable Converts 25 pin to 29 pin cable.
Agilent 35900-60970 Agilent Remote Cable For 7673/5890/35900.
Agilent 35900-60980 Agilent Remote Y-Cable 5890/7673 to integrator.
Agilent 3980-0672 Agilent HP 1090 Pump and Flow Path Supplies Sapphire piston for HP 1090.
Agilent 410103101 Agilent Transferlien Deactivated Transferline deactivated
Agilent 410105007 Agilent Pressure Regulator Pressure regulator with knob
Agilent 410105010 Agilent Flow Controller Flow controller with knob
Agilent 410105017 Agilent Tubing Tubing, solenoids to 6-port, deactivated
Agilent 410205001 Agilent Link Repair Kit Tray chain link repair kit
Agilent 420-1000 Agilent Column Installation Kit, Diamond-Tipped Column Cutting Pencil Column Installation Kit, Diamond-Tipped Column Cutting Pencil.
Agilent 430-1020 Agilent Magnifier, 20X 20X replacement or accessory magnifier for use with chromatography systems.
Agilent 430-2000 Agilent J&W Scientific Column Installation Kit Contains diamond-tipped pencil, ferrule removal tool, 20X magnifier, septum removal tool, and a refillable 59.1mL (2oz.) bottle of Snoop* leak detecting solution.
Agilent 430-3000 Agilent Column Rinse Kit, Capillary Rinse Kit This kit makes solvent rinsing easy! Solvent rinsing removes many contaminants that accumulate in columns. The contaminates are removed by passing solvents through the column.
Agilent 440-1000 Agilent Ferrule Tool For working small, capillary sized graphite ferrules. The tapered spiral tip allows the tool to be easily inserted into capillary sized hole for ferrule handling or removal purposes. Lower half of the body ridged for a secure hand grip.
Agilent 446910-102 Agilent Agilent Prep-C18 21.2x50mm, 10um.
Agilent 450-1000 Agilent Septum Tool The surgical steel tip can get into small spaces to remove small pieces of septa and for removing pieces of graphite ferrule.
Agilent 460-1002 Agilent Snoop* Leak test most pressurized gas systems. Squeezable bottle includes "Snooper Tube" extendable up to 30cm. 3.8L
Agilent 480-0001 Agilent FID Cleaning Kit FID Cleaning Kit.
Agilent 480-0003 Agilent Injection Port Cleaning Kit If changing the liner and trimming the column does not remove contamination from your injection port, you probably need to clean and flush your injection port.
Agilent 500-1004 Agilent Vespel*/Graphite Ferrules One-piece Vespel*/Graphite (60%/40%) ferrules have upper temperature limits of 400[degree]C. Preferred for GC/MS systems. Compatible with Swagelok* fittings. 1.588mm (1/16") x 0.4mm I.D. Column I.D.: 0.05 - 0.25mm.
Agilent 500-1005 Agilent Vespel*/Graphite Ferrules One-piece Vespel*/Graphite (60%/40%) ferrules have upper temperature limits of 400[degree]C. Preferred for GC/MS systems. Compatible with Swagelok* fittings. 1.588mm (1/16") x 0.5mm I.D. Column I.D.: 0.32mm.
Agilent 500-1008 Agilent Vespel*/Graphite Ferrules One-piece Vespel*/Graphite (60%/40%) ferrules have upper temperature limits of 400[degree]C. Preferred for GC/MS systems. Compatible with Swagelok* fittings. 1.588mm (1/16") x 0.8mm I.D. Column I.D.: 0.53mm.
Agilent 500-1060 Agilent Graphite/Vespel Ferrule For J&W injection port conversion kits. 6mm.
Agilent 500-1200 Agilent Polyimide Sealing Resin Permanently connects fused silica columns to glass unions. Each connection is stable to 300[degree]C. 5g size.
Agilent 5001-3707 Agilent 79851A/52 Pump Module Parts and Supplies Outlet gold seal. HP 1050 Pump.
Agilent 5001-3708 Agilent HP 1050 TI Pump Pump Module Parts and Supplies. Inlet gold seal.
Agilent 5001-3730 Agilent Sipper Supplies Mounting cover for HP 8452A. UV/VIS. May be used as sample area dust cover; not compatible with HP 89075C multicell transport and HP 89090A temperature control accessory.
Agilent 5001-3738 Agilent Rod, stainless steel Use with column holder plate 5062-2469.
Agilent 5001-3739 Agilent
Agilent 5001-3743 Agilent Seal Keeper For pump seal wash.
Agilent 500-2004 Agilent Graphite Ferrules One-piece graphite ferrules have upper temperature limits of 450[degree]C. Compatible with Swagelok* fittings. 1.588mm (1/16") x 0.4mm I.D. Column I.D.: 0.05 - 0.25mm.
Agilent 500-2005 Agilent Graphite Ferrules One-piece graphite ferrules have upper temperature limits of 450[degree]C. Compatible with Swagelok* fittings. 1.588mm (1/16") x 0.5mm I.D. Column I.D.: 0.32mm.
Agilent 500-2008 Agilent Graphite Ferrules One-piece graphite ferrules have upper temperature limits of 450[degree]C. Compatible with Swagelok* fittings. 1.588mm (1/16") x 0.8mm I.D. Column I.D.: 0.53mm.
Agilent 500-2066 Agilent Liners Ferrules for J&W Conversion Kits Graphite Ferrule for 6 mm Mega/Split-Splitless Injection Port Liner, Double Taper (set of 10). J&W offers a wide variety of Megaboreliners.
Agilent 500-2114 Agilent Ferrules, HP, 0.4 mm I.D Graphite. 6880, 5890 (Short Nut), 4890. 0.4 mm I.D. Column size: 0.05-0.25 mm. Ferrules. J&W supplies graphite and graphite / vespel ferrules for your chromatographic needs. J&W packages ferrules in wide-mouthed glass vials for easy removal and high product purity.
Agilent 5020-8231 Agilent FID flow measuring adapter tubing Red rubber tubing to attach FID flow measuring adpater (19301-60660) to flow meter tubing.
Agilent 5020-8292 Agilent Ferrules and Nuts for Capillary Columns Finger-tight column nut for <=320 um columns. Fittings can be used with graphite ferrules only. These ferrules are recommended for use with GC inlets and FID, NPD and ECD.
Agilent 5020-8293 Agilent Ferrules and Nuts for Capillary Columns Finger-tight column nut for 530 um columns. Fittings can be used with graphite ferrules only. These ferrules are recommended for use with GC inlets and FID, NPD and ECD.
Agilent 5020-8294 Agilent Ferrules and Nuts for Capillary Columns Blanking plug, finger-tight style. These ferrules are recommended for use with GC inlets and FID, NPD and ECD. The 100% Vespel ferrule can be used for most applications and will emerge from the fitting in reusable condition time and again.
Agilent 5021-1816 Agilent Flexible Tubing (stainless steel), without fittings Length: 105 mm. Color code: green. ID: 0.17 mm.
Agilent 5021-1817 Agilent Flexible Tubing (stainless steel), without fittings Length: 150 mm. Color code: green. ID: 0.17 mm.
Agilent 5021-1818 Agilent Flexible Tubing (stainless steel), without fittings Length: 280 mm. Color code: green. ID: 0.17 mm.
Agilent 5021-1819 Agilent Flexible Tubing (stainless steel), without fittings Length: 400 mm. Color code: green. ID: 0.17 mm.
Agilent 5021-1820 Agilent Flexible Tubing (stainless steel), without fittings Length: 105 mm. Color code: red. ID: 0.12 mm.
Agilent 5021-1821 Agilent Flexible Tubing (stainless steel), without fittings Length: 150 mm. Color code: red. ID: 0.12 mm.
Agilent 5021-1822 Agilent Flexible Tubing (stainless steel), without fittings Length: 280 mm. Color code: red. ID: 0.12 mm.
Agilent 5021-1823 Agilent Flexible Tubing (stainless steel), without fittings Length: 400 mm. Color code: red. ID: 0.12 mm.
Agilent 5021-1831 Agilent OQ/PV Test Capillary 50cm. ID: 0.25mm.
Agilent 5021-1845 Agilent Cartridge Holder Easy to use cartridge holder accommodates 2, 3, 4, and 4.6mm diameter cartridges of varying lengths. Hardware kit for cartridge columns.
Agilent 5021-1846 Agilent Cartridge Mounting Tool Mounting tool for replacing filters in cartridge column systems.
Agilent 5021-1849 Agilent Agilent Cartridge split collets, 2/pk Agilent Cartridge split collets, 2/pk.
Agilent 5021-1854 Agilent Agilent Cartridge compression cones 2/pk Agilent Cartridge compression cones 2/pk.
Agilent 5021-1866 Agilent HP 1049 Electrochemical Detector Parts and Supplies Mounting clamp.
Agilent 5021-1867 Agilent HP 1049 Electrochemical Detector Parts and Supplies Inlet connection nut and ferrule.
Agilent 5021-1870 Agilent HP 89090A Peltier Temperature Controller Supplies Union, cell holder (Kel-F). UV/VIS.
Agilent 5021-1871 Agilent Autosampler Parts and Supplies Zero dead-volume union, Titanium. HP 1050 TI Autosampler.
Agilent 5021-7107 Agilent Copper tubing, 1/8in 12ft Copper tubing, 1/8in 12ft.
Agilent 5021-7117 Agilent Fluoropolymer resin tubing, 1/8in od, per ft. fluoropolymer resin tubing, 1/8in od, per ft.
Agilent 5021-7127 Agilent 79851A/52 Pump Module Parts and Supplies Polyethylene actuator air tubing, per meter. HP 1050 Pump.
Agilent 5021-7133 Agilent Capillary Column Connectors Accessories for Ferrules for Graphpak Connection Systems. Plug ferrule.
Agilent 5021-7134 Agilent Capillary Column Connectors Ferrules for Graphpak Connection Systems. Column ID: 0.53 mm. Column OD: 0.7 mm.
Agilent 5021-7136 Agilent Capillary Column Connectors Ferrules for Graphpak Connection Systems. Column ID: 0.2 mm. Column OD: 0.3 mm.
Agilent 5021-7137 Agilent Capillary Column Connectors Ferrules for Graphpak Connection Systems. Column ID: 0.32/0.25 mm. Column OD: 0.4 mm.
Agilent 5021-7146 Agilent Capillary Column Connectors Graphpak Divider for Simultaneous Sampling to Two Capillary Columns. Column ID: 0.53 mm. Column OD: 0.7 mm.
Agilent 5021-7148 Agilent Capillary Column Connectors Graphpak Divider for Simultaneous Sampling to Two Capillary Columns. Column ID: 0.32/0.25 mm. Column OD: 0.4 mm.
Agilent 5021-7164 Agilent Capillary Column Connectors Graphpak Connector for HP Capillary Detector Ports. Column ID: 0.53 mm. Column OD: 0.7 mm.
Agilent 5021-7166 Agilent Capillary Column Connectors Graphpak Connector for HP Capillary Detector Ports. Column ID: 0.32/0.25 mm. Column OD: 0.4 mm.
Agilent 5021-7168 Agilent Capillary Column Connectors Graphpak Connector for HP Capillary Injection Ports. Column ID: 0.53 mm. Column OD: 0.7 mm.
Agilent 5021-7169 Agilent Capillary Column Connectors Graphpak Connector for HP Capillary Injection Ports. Column ID: 0.2 mm. Column OD: 0.3 mm.
Agilent 5021-7170 Agilent Capillary Column Connectors Graphpak Connector for HP Capillary Injection Ports. Column ID: 0.32/0.25 mm. Column OD: 0.4 mm.
Agilent 5022-2126 Agilent Fused Silica To 1.6mm ttubing connector. For connecting CEC capillaries to LC pumps for the purpose of flushing with buffer using hydrolic pressure.
Agilent 5022-2145 Agilent True ZDV Union Top. Seal. For 500nL Flow Cell.
Agilent 5022-2146 Agilent Union Adjustment Tool For True ZDV Union.
Agilent 5022-2154 Agilent Tefzel Ferrule For use with spectrophotometer sipper pump. With 1.6mm stainless steel lock rings.
Agilent 5022-2156 Agilent Cell Fittings Kit For use with spectrophotometer flow cells. 4 short, 4 long.
Agilent 5022-2159 Agilent Capillary Stainless steel. Ferrule. ID: 0.12. 2m.
Agilent 5022-2192 Agilent Stainless Steel Filter Assembly With PEEK ring. For Agilent 1100 Series Preparative Pump. 2um pore size.
Agilent 5022-6531 Agilent Test tubes, 12x100 mm 250/pk.
Agilent 5022-6532 Agilent Test tubes 16x100 mm 250/pk.
Agilent 5022-6534 Agilent Test tubes 12x48 mm 100/pk.
Agilent 5041-2163 Agilent Tube Screw Use with Agilent 79851A/52 pump module. For bottle head assembly tube.
Agilent 5041-2166 Agilent Pump tubing, 2.06 mm id, 10.3 ml/min (60 Hz), 8.6 ml/min (50 Hz) UV/VIS. 12/pk.
Agilent 5041-2167 Agilent Peristaltic Pump Supplies Nylon cassette sipper (holds pump tubing). UV/VIS. With HP 89052B pump, flow rates are fixed. With the HP 89092A, pumping speed is variable.
Agilent 5041-2184 Agilent Pump tubing, Tygon* 1.3mm id 12/PK.
Agilent 5041-2185 Agilent Pump tubing, Tygon* 2.8mm id, 12/PK.
Agilent 5041-2199 Agilent Fittings for Flow Cells Cell ferrules. UV/VIS.
Agilent 5041-8339 Agilent 79851A/52 Pump Module Parts and Supplies Glass filter, 10-16 ul pore size, (for helium). HP 1050 Pump.
Agilent 5042-0922 Agilent Inner Sleeve For Agilent 7500 ICP-MS trace element measurement unit. For carrier/auxiliary/blend gas.
Agilent 5042-0923 Agilent Inner Sleeve For Agilent 7500 ICP-MS trace element measurement unit. For plasma gas line.
Agilent 5042-1336 Agilent Heat Exchanging Tube For Agilent 89090A Peltier Temperature Controller. Use for preheating of samples.
Agilent 5042-1356 Agilent Cassette For spectrophotometers. Variable pressure.
Agilent 5042-6443 Agilent Backpressure Regulator For Agilent part numbers G131B DAD and MWD. 100psi.
Agilent 5042-6500 Agilent Double winged 2 piece fitting 1/16inch 10pk PEEK fittings for standard 1/16inch od capillaries.
Agilent 5060-9055 Agilent HP 5880 Detector Supplies Thermal Conductivity Detector (TCD) Replacement filament cartridge kits. Pressure check plug.
Agilent 5060-9077 Agilent Moisture Trap not conditioned Moisture Trap not conditioned
Agilent 5060-9084 Agilent Moisture Trap, preconditioned Moisture trap: metal casing, s-shaped trap for carrier gas cleanup. It contains Molecular Sieve 5Angstroms, 45/60 mesh, 1/8 in. fittings. Can be reconditioned. These traps can be reconditioned by heating at a minimum of 350[degree]C, with flow for 6 hours.
Agilent 5060-9086 Agilent Petrochemical Qualitative Petrochemical Standards. Reference Gas Oil No. 1 Batch 2. Mulltiple component mixture of hydrocarbons from petroleum fractions. Used for performance verification of the Agilent Technologies simulated distillation analyzer, Option 840.
Agilent 5060-9096 Agilent Hydrocarbon Trap Activated charcoal trap: metal casing, s-shaped trap filled with 40/60 mesh activated charcoal, used for trapping organics from gases, 1/8 in. fittings.
Agilent 5061-3303 Agilent Stainless Steel Fittings Stainless Steel Fittings
Agilent 5061-3304 Agilent Flexible Capillary Start-Up Kit (stainless steel) Capillary Tubing Kits.
Agilent 5061-3315 Agilent Flexible Capillary Kit (stainless steel) Capillary Tubing Kits.
Agilent 5061-3325 Agilent HP 1050 Manual Injector Manual Injector Parts and Supplies. Fitting kit for sample loops. Includes: 2 stainless steel fittings, 2 ferrules.
Agilent 5061-3327 Agilent Parts and Supplies for HP 1037/40/46/47/49 Detectors Parts for HP 1046 Programmable Fluorescence Detector. Filter kit: five filters (389 nm, 408 nm, 450 nm, 500 nm, 550 nm).
Agilent 5061-3328 Agilent Parts and Supplies for HP 1037/40/46/47/49 Detectors Parts for HP 1046 Programmable Fluorescence Detector. Filter kit: five filters (380 nm, 399 nm, 418 nm, 470 nm, 520 nm).
Agilent 5061-3329 Agilent Parts and Supplies for HP 1037/40/46/47/49 Detectors Parts for HP 1046 Programmable Fluorescence Detector. Filter kit: five filters (280 nm, 295 nm, 305 nm, 335 nm, 345 nm).
Agilent 5061-3335 Agilent Reagents for Amino Acid Analysis for use with HP 1100. OPA reagent, 10 mg/ml each in 0.4 M borate buffer o-phthalaldehyde (OPA) and 3-mercaptopropionic acid, 6 ampoules. Buy limited quantities because of shelf-life considerations.
Agilent 5061-3337 Agilent Reagents for Amino Acid Analysis for use with HP 1100. 1 ml. FMOC reagent, 2.5 mg/ml in acetonitrile, 9-fluorenylmethylchloroformate. Buy limited quantities because of shelf-life considerations.
Agilent 5061-3339 Agilent Reagents for Amino Acid Analysis for use with HP 1100. 100 ml. Borate buffer. Buy limited quantities because of shelf-life considerations.
Agilent 5061-3361 Agilent Rigid Capillary Tubing (stainless steel), precut, without fittings Capillary Tubing Kits. 10/pk.
Agilent 5061-3362 Agilent Rigid Capillary Tubing (stainless steel), precut, without fittings Capillary Tubing Kits. 10/pk.
Agilent 5061-3377 Agilent Sipper Supplies Sipper/sampler cable for HP 8452A. UV/VIS.
Agilent 5061-3378 Agilent Remote Start/Stop Cables from HP 1050 Series to HP 1090 II Series, HP 1050 Series modules, 1 m Remote Start/Stop Cables from HP 1050 Series to HP 1090 II Series, HP 1050 Series modules, 1 m
Agilent 5061-3384 Agilent Macro Cells - with PTFE lid The macro cell which is defined by DIN 58963 as a rectangular cell with an inner width above 5 mm, has emerged as the standard for photometry. The most widely used macro cell is a rectangular cell with outer dimensions of 45 x 12.5 mm (height x width).
Agilent 5061-3385 Agilent Macro Cells, with PTFE Lid Path length: 2mm. Dimensions: 12.5Wx45Hx4.5Dmm. The macro cell (defined by DIN 58963 as a rectangular cell with an inner width above 5mm) has emerged as the standard for photometry.
Agilent 5061-3386 Agilent Macro Cells, with PTFE Lid Path length: 5mm. Dimensions: 12.5Wx45Hx7.5Dmm. The macro cell (defined by DIN 58963 as a rectangular cell with an inner width above 5mm) has emerged as the standard for photometry.
Agilent 5061-3387 Agilent Macro Cells, with PTFE Lid Path length: 10mm. Dimensions: 12.5Wx45Hx12.5Dmm. The macro cell (defined by DIN 58963 as a rectangular cell with an inner width above 5mm) has emerged as the standard for photometry.
Agilent 5061-3388 Agilent Cell Accessories Spacer for 1 mm cell. UV/VIS. Spacers permit accurate positioning of 1, 2, and 5 mm path length open-topped cells in standard 10 mm path length cell holders. They are not required for short path length flow cells because these have the same external dimensions as the 10 mm cell.
Agilent 5061-3389 Agilent Cell Accessories Spacer for 2 mm cell. UV/VIS. Spacers permit accurate positioning of 1, 2, and 5 mm path length open-topped cells in standard 10 mm path length cell holders. They are not required for short path length flow cells because these have the same external dimensions as the 10 mm cell.
Agilent 5061-3390 Agilent Cell Accessories Spacer for 5 mm cell. UV/VIS. Spacers permit accurate positioning of 1, 2, and 5 mm path length open-topped cells in standard 10 mm path length cell holders. They are not required for short path length flow cells because these have the same external dimensions as the 10 mm cell.
Agilent 5061-3391 Agilent Quartz Semi-micro Cell With PTFE Lid Path Length: 10mm. Exterior Dimensions: 46Hx12.5Wx12.5Dmm. Interior Dimensions: 41.8x2mm. Volume: 700uL.
Agilent 5061-3392 Agilent Cylindrical Cells - with PTFE stopper These cells are specifically designed for use in the ul (down to 50 ul) where, for technical reasons, flow-through cells cannot be used.
Agilent 5061-3396 Agilent Flow Cells - rectangular aperture with screw fittings Standard cells are rectangular cells with standardized exterior dimensions. These cells fit into all common analytical instruments such as calorimeters, photometers, and spectrophotometers.
Agilent 5061-3397 Agilent Flow Cells - rectangular aperture with screw fittings Standard cells are rectangular cells with standardized exterior dimensions. These cells fit into all common analytical instruments such as calorimeters, photometers, and spectrophotometers.
Agilent 5061-3398 Agilent Flow Cells - rectangular aperture with screw fittings Standard cells are rectangular cells with standardized exterior dimensions. These cells fit into all common analytical instruments such as calorimeters, photometers, and spectrophotometers.
Agilent 5061-5801 Agilent Capillary Column Connectors Metal Capillary Column Connectors. Connector, body and nut.
Agilent 5061-5804 Agilent Capillary Column Connectors Ferrules, for connecting: 0.2- to 0.53-mm id tubing.
Agilent 5061-5805 Agilent Capillary Column Connectors Ferrules, for connecting: 0.32- to 0.32-mm id tubing.
Agilent 5061-5806 Agilent Capillary Column Connectors Ferrules, for connecting: 0.32- to 0.53-mm id tubing.
Agilent 5061-5853 Agilent HP 5970 MSD Parts and Supplies Truarc clip, large.
Agilent 5061-5867 Agilent HP 5890 Detector Supplies FPD Supplies. O-ring.
Agilent 5061-5869 Agilent HP 5890 Split/Splitless Multimode Inlet Split/Splitless Inlet Parts. Washer.
Agilent 5061-5870 Agilent HP 5970 MSD Parts and Supplies Washer, flat.
Agilent 5061-5871 Agilent HP 5970 MSD Parts and Supplies Washer, curved spring.
Agilent 5061-5886 Agilent HP 5890 Detector Supplies FPD Supplies. Window O-ring, inner.
Agilent 5061-5889 Agilent HP 5890 Detector Supplies FPD Supplies. Viton O-ring, brown, 0.926 in. id.
Agilent 5061-5890 Agilent HP 5890 Detector Supplies FPD Supplies. Viton O-ring, brown, 1.239 in. id.
Agilent 5061-5891 Agilent HP 5890 Detector Supplies FPD Supplies. Window O-ring, outer.
Agilent 5061-5896 Agilent Abrasive Sheet Aluminum oxide green lapping paper for ion source cleaning, 600 mesh. 3um.
Agilent 5062-2418 Agilent Stainless Steel Fittings Fittings and ferrules, 1/16 in. 10/ea.
Agilent 5062-2419 Agilent PEEK Tubing and Fittings Safety tubing for PEEK tubing, fluoropolymer resin, 2 x 3 mm, 5 m.
Agilent 5062-2461 Agilent 79851A/52 Pump Module Parts and Supplies Helium tubing, 5 m, fluoropolymer resin,.057 in. id. HP 1050 Pump.
Agilent 5062-2462 Agilent Tubing fluoropolymer resin tubing. I.D.: 0.7mm. Length: 5m. 1050 module flow connector from detector to waste.
Agilent 5062-2463 Agilent HP 1100 Series LC Autosampler Supplies G1313A Autosampler Parts and Supplies. Waste tubing, 5 m, 6.5 mm id, corrugated tubing polypropylene.
Agilent 5062-2465 Agilent Support ring for 1050 seal wash option Support ring for 1050 seal wash option.
Agilent 5062-2469 Agilent Column holder assembly Must also order support rod 5001-3738.
Agilent 5062-2474 Agilent HP 1049 Electrochemical Detector Parts and Supplies Silicone tubing.
Agilent 5062-2476 Agilent Flow Cells - rectangular aperture with screw fittings Standard cells are rectangular cells with standardized exterior dimensions. These cells fit into all common analytical instruments such as calorimeters, photometers, and spectrophotometers.
Agilent 5062-2477 Agilent Macro Cells - with PTFE stopper The macro cell which is defined by DIN 58963 as a rectangular cell with an inner width above 5 mm, has emerged as the standard for photometry. The most widely used macro cell is a rectangular cell with outer dimensions of 45 x 12.5 mm (height x width).
Agilent 5062-2479 Agilent Reagents for Amino Acid Analysis for use with HP 1100. 5 g. DTDPA (Dithiodiproprionic) reagent for analysis or cysteine. Buy limited quantities because of shelf-life considerations.
Agilent 5062-2480 Agilent Anion chromatography kit Mobile phase additive. Includes: LC cartridge, cartridge holder, mobile phase additive, sodium hydroxide solutions, check out sample, handbook. Buy limited quantities because of shelf-life considerations.
Agilent 5062-2483 Agilent 79851A/52 Pump Module Parts and Supplies Solvent tubing, FEP, 5 m, 1.5 mm id, 3 mm od. HP 1050 Pump.
Agilent 5062-2484 Agilent 79851A/52 Pump Module Parts and Supplies Gasket, wash seal. HP 1050 Pump.
Agilent 5062-2485 Agilent 79851A/52 Pump Module Parts and Supplies Outlet caps. HP 1050 Pump.
Agilent 5062-2486 Agilent 79851A/52 Pump Module Parts and Supplies Velocity regulator. HP 1050 Pump.
Agilent 5062-2494 Agilent HP 1090 Pump and Flow Path Supplies Pump seal, Black Vespel.
Agilent 5062-2495 Agilent HP Automatic Liquid Sampler Supplies Crimping System. Holder without crimp head, to be mounted.
Agilent 5062-2496 Agilent Ultra-micro Cells - with PTFE stopper These cells are specifically designed for use in the ul (down to 50 ul) where, for technical reasons, flow-through cells cannot be used.
Agilent 5062-2497 Agilent Macro Cells - with PTFE stopper These cells are specifically designed for use in the ul (down to 50 ul) where, for technical reasons, flow-through cells cannot be used. These cells fit into any standard cell holder and have the advantage of requiring much smaller sample volumes than standard cells.
Agilent 5062-3506 Agilent Vespel*/Graphite Capillary Inlet Ferrules 0.5mm Preconditioned 15% Graphite, 85% Vespel ferrules have an upper temperature limit of 400[degree]C, and are recommended for use with GC/MS. Column ID: 0.32mm.
Agilent 5062-3507 Agilent Ferrules and Nuts for Capillary Columns Preconditioned 85% Vespel, 15% Graphite Ferrules. Ferrule ID: 0.3 mm. Column ID: 100 um. These ferrules are recommended for use with GC/MS.
Agilent 5062-3508 Agilent Vespel*/Graphite Capillary Inlet Ferrules 0.4mm Preconditioned 15% Graphite, 85% Vespel ferrules have an upper temperature limit of 400[degree]C, and are recommended for use with GC/MS. Column ID: 0.20-0.25mm.
Agilent 5062-3509 Agilent Capillary Column Connectors Glass Connector Trial Kit for Capillary Columns. Kit contains 3 ea of 530- to 530-um, 530- to 320-um, 530- to 200-um, 200- to 320-um, 200- to 200-um.
Agilent 5062-3511 Agilent Vespel* Capillary Inlet Ferrules 0.8mm 100% Vespel ferrules are made from high-temperature polyimide and have an upper temperature limit of 350[degree]C. Column ID: 0.53mm.
Agilent 5062-3512 Agilent Vespel*/Graphite Capillary Inlet Ferrules 0.8mm. 85% Vespel, 15% Graphite ferrules have an upper temperature limit of 400[degree]C. Column ID: 0.53mm.
Agilent 5062-3513 Agilent Ferrules and Nuts for Capillary Columns 100% Vespel High-Performance Ferrules. Ferrule ID: 0.47 mm. Column ID: 320 um. These ferrules are recommended for use with GC inlets and FID, NPD and ECD.
Agilent 5062-3514 Agilent Vespel*/Graphite Capillary Inlet Ferrules 0.5mm. 85% Vespel, 15% Graphite ferrules have an upper temperature limit of 400[degree]C. Column ID: 0.32mm.
Agilent 5062-3515 Agilent Ferrules and Nuts for Capillary Columns 100% Vespel High-Performance Ferrules. Ferrule ID: 0.37 mm. Column ID: 200 um. These ferrules are recommended for use with GC inlets and FID, NPD and ECD.
Agilent 5062-3516 Agilent Ferrules and Nuts for Capillary Columns 85% Vespel, 15% Graphite Ferrules. Ferrule ID: 0.37 mm. Column ID: 200 um. These ferrules are recommended for use with GC inlets and FID, NPD and ECD.
Agilent 5062-3518 Agilent Ferrules and Nuts for Capillary Columns 85% Vespel, 15% Graphite Ferrules. Ferrule ID: 0.27 mm. Column ID: 100 um. These ferrules are recommended for use with GC inlets and FID, NPD and ECD.
Agilent 5062-3525 Agilent Capillary Column Connectors Accessories for Ferrules for Graphpak Connection Systems. Replacement column nut.
Agilent 5062-3538 Agilent Vespel*/Graphite Capillary Inlet Ferrules 0.8mm. Preconditioned 15% Graphite, 85% Vespel ferrules have an upper temperature limit of 400[degree]C, and are recommended for use with GC/MS. Column ID: 0.53mm.
Agilent 5062-3550 Agilent Capillary Column Connectors Glass Press-Fit Connector for: 0.32- to 0.25-mm tubing.
Agilent 5062-3551 Agilent Capillary Column Connectors Glass Press-Fit Connector for: 0.53- to 0.25-mm tubing.
Agilent 5062-3552 Agilent Capillary Column Connectors Glass Press-Fit Connector for: 0.1- to 0.32-mm tubing.
Agilent 5062-3553 Agilent Capillary Column Connectors Glass Press-Fit Connector for: 0.1- to 0.25-mm tubing.
Agilent 5062-3554 Agilent Capillary Column Connectors Glass Press-Fit Connector for: 0.32- to 0.25-mm tubing.
Agilent 5062-3556 Agilent Glass Press-Fit connector 250-250um 10/pk (equivalent to J&W C2002-10 and C2002-5)
Agilent 5062-3561 Agilent Paper and Supplies for HP 3397A, HP 3396 Series III, and HP 3396A/B/95/94 Z-fold paper, sequentially numbered, 8.5 x 11 in. InkJet (5 pk/box) (2,500 sheets).
Agilent 5062-3580 Agilent Capillary Splitters Two-hole replacement ferrules. Tubing ID: 0.4 mm.
Agilent 5062-3581 Agilent Capillary Splitters Two-hole replacement ferrules. Tubing ID: 0.5 mm.
Agilent 5062-3587 Agilent Single Taper Liner for Capillary Inlet Systems 4mmIDx0.8IDmm taper. Volume: 900uL. For sensitive compounds. Borosilicate glass. 10gm silanized glass wool packing ensures mixing and traps septum particles, preventing them from reaching the column.
Agilent 5062-8514 Agilent Back ferrule 1/16" gold plated 10/PK Back ferrule 1/16" gold plated 10/PK.
Agilent 5062-8515 Agilent 79851A/52 Pump Module Parts and Supplies Connector for helium sparger. HP 1050 Pump.
Agilent 5062-8517 Agilent Filter Frit Adapter PTFE 3 mm. Spare Parts. CE AND CE/MS.
Agilent 5062-8518 Agilent G1303 Online Degasser Parts and Supplies Male nuts. HP 1050 Online Degasser.
Agilent 5062-8519 Agilent G1303 Online Degasser Parts and Supplies Ferrules. HP 1050 Online Degasser.
Agilent 5062-8522 Agilent 79853C Variable Wavelength Detector (VWD) Supplies PEEK inlet tubing assembly, 40 cm,.007 in. id, 1/16 in. od. HP 1050 TI Detector.
Agilent 5062-8524 Agilent CE AND CE/MS Anion Test Mixture (Cl, Br, SO4, NO3, NO2, F, PO4), also used for HPLC. Inorganic Anion Solutions Kit. Using an indirect-UV detection system optimized for small anions, analyses are sensitive and rapid and provide an alternative to traditional ion chromatography.
Agilent 5062-8529 Agilent Cell cleaning fluid, 1L
Agilent 5062-8530 Agilent Parts and Supplies for HP 1037/40/46/47/49 Detectors Parts for HP 1046 Programmable Fluorescence Detector. Cutoff filter, 295 nm.
Agilent 5062-8535 Agilent Outlet tubing
Agilent 5062-8541 Agilent PEEK Tubing and Fittings Finger-tight fittings, long, 1/16 in. 10/pk.
Agilent 5062-8544 Agilent Electrode O-ring, silicone Spare Parts. CE AND CE/MS.
Agilent 5062-8553 Agilent Washer 10pk
Agilent 5062-8562 Agilent Cartridge For active inlet valve (HPG1312-60010).
Agilent 5062-8574 Agilent 50 mM sodium tetraborate, 100 mM sodium dodecyl sulfate buffer, pH 9.3 Micellar Electrokinetic Chromatography (MEKC) Buffer for Neutral and Charged Analytes. CE AND CE/MS. 250 ml. Micellar Electrokinetic Chromatography (MEKC) Buffer for Neutral and Charged Analytes.
Agilent 5062-8587 Agilent Sapphire Piston For 900uL sampler option.
Agilent 5062-9508 Agilent GC Valves and Loops Compatible with HP 5890/6890 General-Purpose Valves, Gas sampling. 6 port replacement valve WE series, 400 psi, 225[degree]C.
Agilent 5062-9509 Agilent 6-Port Valve WE series. Hastelloy-C. Maximum temperature: 225[degree]C.
Agilent 5062-9510 Agilent GC Valves and Loops Compatible with HP 5890/6890 General-Purpose Valves. Gas sampling. 10 port replacement valve WE series, 400 psi, 225[degree]C.
Agilent 5062-9511 Agilent GC 10-Port Valve WE series. Hastelloy C. 400 psi. 225[degree]C.
Agilent 5063-6505 Agilent Stainless Steel Sieve Outlet Valve Replacement part for servicing an 1100 binary pump.
Agilent 5063-6506 Agilent Finger Cap For vial gripper.
Agilent 5063-6531 Agilent Bottle Cap with 3-Hole Insert For Agilent G1311/12/54A Standard Pumps.
Agilent 5063-6586 Agilent 79851A/52 Pump Module Parts and Supplies Sapphire piston (plunger). HP 1050 Pump.
Agilent 5063-6589 Agilent Piston seals for Agilent 1100/1050, Vespel, 2/pk Graphitized fluoropolymer resin.
Agilent 5063-6591 Agilent Finger-tight PEEK Long Fittings 1.6mm.
Agilent 5063-6592 Agilent Upchurch Liteouch Ferrules Lifetouch 100. Front and back.
Agilent 5063-6593 Agilent Nut For capillary LC. Stainless steel. 1.6mm. 4mm fittings.
Agilent 5063-6596 Agilent Preventive Maintenance Kit For HP1090.
Agilent 5063-6598 Agilent Tefzel Ferrule with Stainless Steel Lock Ring 3.2mm. Excellent chemical resistance to most solvents. 1200psi. Maximum Temperature: 23[degree]C.
Agilent 5063-6599 Agilent Polyphenylene Sulfide Nut For 3.2mm OD tubing. 1/4-28 thread. Excellent chemical resistance to most organic solvents at room temperature. 4100psi. Maximum Temperature: 50[degree]C.
Agilent 5064-8034 Agilent Tygon Peristalitic Pump Tubing For Agilent 7500 Pump. I.D.: 0.25mm. 3 stops.
Agilent 5064-8078 Agilent 4mm Union Fitting PFConcentric Nebulizer 7500 ICP-MS (inductively coupled plasma mass spectrometer ).
Agilent 5065-4422 Agilent Double Winged Nut With 0.79mm ferrule.
Agilent 5065-4423 Agilent Ferrule 0.79mm. For capillary LC. With stainless steel lock ring.
Agilent 5065-9915 Agilent Holder for 5 mm trap cartridges
Agilent 5065-9931 Agilent Flex capillary 0.17x200mm, no fittings, stainless steel.
Agilent 5065-9932 Agilent Flex capillary 0.17x700mm, no fittings, stainless steel.
Agilent 5065-9933 Agilent Flex capillary 0.17x600mm, no fittings, stainless steel.
Agilent 5065-9967 Agilent X-Long fittings and ferrules Stainless Steel, 10/PK, for 1/16inch od tubing, 10-32 thread. Front and back ferrules.
Agilent 5065-9978 Agilent Silicone Tubing 1mm ID, 3mm OD, 5m used with wash option.
Agilent 5067-0223 Agilent Precision Gas Flow Meter Flow range: 5 - 500 ml/min
Agilent 5067-1547 Agilent PEEK Ferrule PEEK ferrule for 1/16 inch od capillaries, max 600 bar pressure, 6/pk. Replacement ferrule for 5067-1540 ferrule plus fitting.
Agilent 5067-1551 Agilent In-line Filter High pressure (max 600 bar) in-line filter for RRLC applications. Comes with 3 x 2 mm, 0.2 um pores size frits and a 70 x 0.12 mm SS connecting capillary
Agilent 5067-1553 Agilent In-line Filter High pressure (max 600 bar) in-line filter for RRLC applications. Comes with 3 x 4.6 mm, 0.2 um pores size frits and a 90 x 0.17 mm SS connecting capillary